Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
第 1 页共 3 页 UserManual SmartCardReader Model:D8 FCCID:2ASFMD8 D8isaICcardreader/writerwhichsupportscardslotwith4SIM card.Thenon-driverUSBbenefitsuser'sinstallationandoperation.It facilitatescommunicationwithPCandrelateddevicesthroughUSB interface.Plus,itdesignedforthosefiledwhichneedmoresecurity requirementslikecardissues.Withvariousofplatform'sdriver kits,supplementarydemonstrateprogramcandoallRFIC functions.Moreover,it'sequippedwithauto-testingcardoperation. D8readerisanecessaryfront-enddeviceforICcarddevelopmentand systemintegration.Withits'richandperfectinterfacefunctions,D8is availableforusinginsmartcardmanagementandapplicationssystemsof charging,storingvalueandquery:industryand commerce,telecommunications,postal.taxation,bank,insurance,medical,met ingattendance,Internetcafemanagementandcarparks... Specifications 第 2 页共 3 页 NameSmartCardReader Processor32bitCPU IndicatorLight4LEDindicatelight,indicatepowersupplyorcommunication status. PressKeyAccessexternalpasswordkeyboard VoiceSupportvoicebroadcast(canbecustomized) BuzzerSupport Communication Interface USB/RS232 ContactCardSupportoneISO/IEC7816ICcard Contact-less Card SupportISO14443TypeA/BinductiveICcard; SupportTypeA/B; SAMCardSlot4 PowerSupplyDC5V,withover-voltageprotection Real-timeClockSupportbuilt-inclock Operating systems SupportWindows98、Me、2K、XP、2003、Unix、Linux Encryption Mode EncryptionmodeHardware/SoftwareEncryption EncryptionalgorithmDES、3DES、RSA Working Environment Temperature:-20°C~60°C Humidity:5c/o~95c/o(non-condensing) Storage Environment Temperature:-20°C~60°C Humidity:5c/o~95c/o(non-condensing) OthersProvidefunctionlibraryofuniversalinterface; Supportvariousofoperatingsystemandlanguagedevelopment platform; Onlineupgradingisavailable. 第 3 页共 3 页 NameSmartCardReader FCCWarning: Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfora ClassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimits aredesignedtoprovidereasonableprotectionagainstharmfulinterference inaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance withtheinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrect theinterferencebyoneormoreofthefollowingmeasures: —Reorientorrelocatethereceivingantenna. —Increasetheseparationbetweentheequipmentandreceiver. —Connecttheequipmentintoanoutletonacircuitdifferentfromthat towhichthereceiverisconnected. —Consultthedealeroranexperiencedradio/TVtechnicianforhelp. MODIFICATION:Anychangesormodificationsnotexpresslyapprovedbythe granteeofthisdevicecouldvoidtheuser’sauthoritytooperatethe device.
Transmitter Antenna
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation for D8 1. Introduction D8 is SmartCard Reader, which contain RFID function inside. 2. Limit and Guidelines on Exposure to Electromagnetic Fields According to§15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 Mobile Portable RF Exposure v05r01, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 3. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Conducted Power + tune up tolerance = 0.0026mW Distance = 5 mm f = 0.01356 GHz [0.0026/5] * SQRT(0.01356) =0.000006 0.000006 ≤ 3.0 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: Phoebe Hu/ EMC Project Manager Felix Li/EMC Project Engineer Date: 2015-09-16 Date: 2015-09-16
Report Number: 68.950.15.188.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 19 FCC - TEST REPORT Report Number : 68.950.15.188.01 Date of Issue: Sep 01, 2015 Model : D8 Product Type : SmartCard Reader Applicant : SHENZHEN DECARD SMARTCARD TECH CO.,LTD. Address : F4 Bldg 17 Wenguang Industrial Zone Chaguang Rd Nanshan District, 518055 Shenzhen, China Production Facility : SHENZHEN DECARD SMARTCARD TECH CO.,LTD. Address : F4 Bldg 17 Wenguang Industrial Zone Chaguang Rd Nanshan District, 518055 Shenzhen, China Test Result : Positive Negative Total pages including Appendices : 19 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval Report Number: 68.950.15.188.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 19 1 Table of Contents 1 Table of Contents .............................................................................................................................. 2 2 Details about the Test Laboratory ..................................................................................................... 3 3 Description of the Equipment Under Test .......................................................................................... 4 4 Summary of Test Standards .............................................................................................................. 5 5 Summary of Test Results .................................................................................................................. 6 6 General Remarks .............................................................................................................................. 7 7 Test Setups ....................................................................................................................................... 8 8 Test Methodology ............................................................................................................................. 9 8.1 Conducted Emission on AC power port ...................................................................................... 9 8.2 Radiated Unwanted Emission .................................................................................................. 12 8.3 Field strength of fundamental emissions & outside the allocated band emissions .................... 13 8.4 Frequency tolerance ................................................................................................................ 15 8.5 20dB Bandwidth ....................................................................................................................... 16 9 Systems test configuration .............................................................................................................. 17 10 Test Equipment List ........................................................................................................................ 18 11 System Measurement Uncertainty .................................................................................................. 19 Report Number: 68.950.15.188.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 19 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 502708 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.950.15.188.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 19 3 Description of the Equipment Under Test Product: SmartCard Reader Model no.: D8 FCC ID: 2AFSMD8 Brand Name: D&C Options and accessories: NIL Rating: 5VDC RF Transmission Frequency: 13.56MHz Modulation: RFID Antenna Type: PCB Antenna Antenna Gain: 0dBi Description of the EUT: The Equipment Under Test (EUT) is a SmartCard Reader with R…
Text truncated - open the document above for the full version.
Conducted emission Radiated emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |