FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RetailNext Inc./
  3. 2AFSV-AURORA-V2-2

2AFSV-AURORA-V2-2Retail IoT Sensor

RetailNext Inc.
Retail IoT Sensor - FCC ID 2AFSV-AURORA-V2-2 - RetailNext Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 06, 2024
Application Purpose
Original Equipment
Date of Application
Jan 01, 2024
Equipment Note
Retail IoT Sensor
Frequency Range
2402.00000000 - 2480.00000000
Company
RetailNext Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 RetailNext Aurora V2.2 Setup and Installation Manual Overview I. This section describes the test setup procedure for RetailNext Aurora V2.2 Aurora is a plug-and-play device, so simply powering on the device is sufficient to make it operational. No configuration is necessary. By default, Aurora does not intentionally transmit any WiFi or BLE signals. Aurora is powered via a standard Power over Ethernet (PoE) injector or switch. If you do not have a standard PoE injector or switch available, please advise RetailNext so we can ship an RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 injector along with the unit. Note that the PoE injector is a standard 3 rd party device that is certified separately by the 3 rd part vendor, and is not to be included as part of the Aurora certification. Plug a standard Cat5e or Cat6 ethernet cable into the open ethernet port on the underside of the Aurora (Figure 1). This is the port that is closest to the bottom plate of the Aurora. You can move the white plastic latch and “flip up” the port to make it easier to access. Figure 1 Now plug the other end of the ethernet cable into the “Data/Power out” port of the PoE injector (Figure 2). Lastly, plug the PoE injector into a power outlet. Figure 2 RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 The LED on the side of the Aurora will illuminate green for a few seconds to indicate that it is powering up. The power-on process takes a couple of minutes. Once the process is complete, the LED will flash green and blue. II. This section describes the Installation procedure for RetailNext Aurora V2.2 Position Aurora 3’ – 4’ away from the entrance and centered. Call RetailNext prior to mounting. Do not drill any holes until you get RetailNext approval. If supplied, mount the Secondary Unit 25’ from Aurora use the same methods (Secondary Unit mount plate is similar to the Aurora). Disclaimer: This document assumes you have installation tools, cable termination experience, and installation skills. Do not plug in any POE injector into the Secondary Unit Port or Secondary Unit. Doing so will cause damage to the unit and it may become unresponsive. Hardware Requirements: • Aurora Sensor ( Do Not Plug POE into Secondary Unit Port ). • Secondary Unit ( Do Not Plug POE into Secondary Unit ). • CAT5e or better cable. • RJ45s. • POE switch. RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 Drop Pole Instructions (Both Aurora Sensor and Secondary Unit): 1. Insert screw into the U-bracket. 2. Place 1x washer on other side of U-bracket. 3. Secure sensor mounting plate to U-bracket (same for the Aurora Sensor). 4. Ensure the cabling has been run through drop pole prior to attaching the U-bracket. 5. Locate bolt and nut that came with the U-bracket. 6. Place U-bracket into position and insert bolt and secure with lock nut. Hard Ceiling Instructions: 1. Place Aurora mounting plate into position, and mark mounting point on ceiling. 2. Use Hard Ceiling screws provided 3. Use proper anchor to mount mounting plate to ceiling. Do not use outer holes for mounting. Drop Ceiling Instructions: 1. Pull cable through ceiling. 2. Use Drop Ceiling screws provided 3. Place Aurora mounting plate into position, and mark mounting point on ceiling. RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 Aurora LED Blink Pattern: Aurora Status Indicator Light Aurora has a status indicator LED on the side of the device. This LED will blink in specific patterns to indicate the current operational status of the device. Common LED patterns The table below describes the common LED blink patterns, what each pattern indicates, and what troubleshooting steps to take when you see a pattern that indicates a problem. LED blink pattern Meaning of pattern Troubleshooting step Green, once every 30 seconds (G, ......, G, ......) Operating normally. Aurora is collecting data and successfully communicating with the RetailNext Cloud. Blue, then Green (B, G, ..., B, G, ...) Aurora failed to acquire an IP address or the DNS server address. Check store DHCP and DNS servers. Also verify that there are no wiring problems, like a faulty cable or RJ- 45 termination. Blue, then Green twice (B, G, G, ..., B, G, G ,...) Aurora has an invalid security certificate. This is an irrecoverable error. Please RMA the Aurora. Blue, then Green thrice (B, G, G, G, ..., B, G, G, G, ...) Aurora failed to connect to the RetailNext Cloud. Check store internet connection and firewall. RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 Other LED patterns An operational Aurora will usually display one of the LED patterns from the table above. Occasionally, you may see other LED patterns while an Aurora is booting up, upgrading its firmware, etc. These patterns are documented below. LED blink pattern Meaning of pattern Green, single long blink Aurora is powered on. The LED will blink Green once when Aurora first receives PoE power. Green, once a second (G, ..., G, ...) Aurora is booting up. This pattern is displayed when Aurora is attempting to acquire an IP address and connect to the RetailNext Cloud. If either of these steps fails, a failure pattern will be displayed as documented in the table above. Blue, once a second (B, ..., B, ...) Aurora is upgrading its firmware. This pattern is displayed when Aurora is attempting to upgrade its firmware. Blue, single long blink Aurora failed firmware upgrade. This pattern is displayed when Aurora attempted but failed to upgrade its firmware. It will automatically revert to the previous good firmware. Solid Green (not blinking) Aurora has encountered an irrecoverable error. Please RMA the device. RetailNext, Inc. | 60 South Market Street, Suite 310, San Jose, CA 95113 FCC Statement: Note: This equipment has been tested and found to comply with the limits for a Class B digital de…

Text truncated - open the document above for the full version.

Attestation Statements

Date: Oct 11, 2023 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2AFSV-AURORA-V2-2 Dear Sir or Madam, Retailnext Inc. (“the applicant”) cer(fies that the equipment for which authoriza(on is sought is not “covered” equipment prohibited from receiving an equipment authoriza(on pursuant to sec(on 2.903 of the FCC rules. We also certify that, Retailnext Inc. (“the applicant”) cer(fies that, as of the date of the filing of the applica(on, the applicant is not iden(fied on the Covered List ( as a specifically named en(ty or any of its subsidiaries or affiliates) as an en(ty producing “covered” equipment . If you have any questions, please contact us. Sincerely, Contact name: Mark Jamtgaard Company name: Retailnext Inc. Address: 60 S. Markiet St, 3 rd Floor, Suite 310, San Jose, California 95113, United States E-mail: [email protected] Tel: 1 408 884 2162 RetailNext, Inc. | 60 S Market Street, Suite 310, San Jose, CA 95113

Attestation Statements

To: Federal Communica1ons Commission Authoriza1on and Evalua1on Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Oct 11, 2023 Ref: AKesta1on Statements Part 2.911(d)(7) Filing FCC ID: 2AFSV-AURORA-V2-2 Retailnext Inc cer1fies that, as of the date of the filing of the applica1on, Retailnext Inc is our designated U.S. agent for service of process for the above referenced FCC ID. Retailnext Inc. accepts to maintain an agent for no less than one year aWer the grantee has terminated all marke1ng and importa1on or the conclusion of any Commission-related proceeding involving the equipment. Retailnext Inc accepts, as of the date of the filing of the applica1on, the obliga1on of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Informa1on: Name: Retailnext Inc FRN: 0024863870 Address: 60 S. Market St, 3 rd Floor, Suite 310, San Jose, California 95113 , United States Contact Person: Mark Jamtgaard Tel.: 1-408-884-2162 Email: [email protected] Signature: Rev 1/26/2023 RetailNext, Inc. | 60 S Market Street, Suite 310, San Jose, CA 95113

Cover Letter(s)

Date Oct 11, 2023 TUV SUD BABT UNLIMITED Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, PO15 5RL United Kingdom Dear Sir or Madam, We, Retailnext Inc. hereby authorize Eric Li, TUV SUD Hong Kong Limited, Unit 301-309, West Wing, Lakeside 2, 10 Science Park West Avenue, Science Park, New Territories Hong Kong, (852) 2776 1323 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 31 st March, 2024. Sincerely, Company Officer: Mark Jamtgaard Telephone Number: 1 408 884 2162 Email: [email protected] RetailNext, Inc. | 60 S Market Street, Suite 310, San Jose, CA 95113

Cover Letter(s)

Date: Oct 11, 2023 TUV SUD BABT UNLIMITED Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, PO15 5RL United Kingdom Confidentiality Request FCC ID: 2AFSV-AURORA-V2-2 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Retailnext Inc. hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation Retailnext Inc. also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Mark Jamtgaard (signed by FCC listed Grantee contact) Telephone Number: 1 408 884 2162 Email: [email protected] RetailNext, Inc. | 60 S Market Street, Suite 310, San Jose, CA 95113

Cover Letter(s)

Date: Oct 11, 2023 To: Federal Communica9ons Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2AFSV-AURORA-V2-2 To Whom It May Concern: This leFer is to ascertain that Retailnext Inc. Product name: Retail IoT Sensor, Model: AURORA V2.2 has been the units used for conduc9ng FCC compliance tes9ng, the SDoC part will be tested by FCC recognized test lab. If you have any ques9on or concerns, please contact us. Sincerely, Contact name: Mark Jamtgaard Company name: Retailnext Inc. Address: 60 S. Markiet St, 3 rd Floor, Suite 310, San Jose, California 95113, United States E-mail: [email protected] Tel: 1 408 884 2162 RetailNext, Inc. | 60 S Market Street, Suite 310, San Jose, CA 95113

External Photos

Model: AURORA V2.2 Page 1 of 3 EUTExternalPhotos Model: AURORA V2.2 Page 2 of 3 EUT External Photos Model: AURORA V2.2 Page 3 of 3 EUT External Photos

ID Label/Location Info

Label Location Label Location

Internal Photos

Model: AURORA V2.2 Page 1 of 14 EUT Internal Photos Model: AURORA V2.2 Page 2 of 14 EUT Internal Photos Model: AURORA V2.2 Page 3 of 14 EUT Internal Photos Model: AURORA V2.2 Page 4 of 14 EUT Internal Photos Model: AURORA V2.2 Page 5 of 14 EUT Internal Photos Model: AURORA V2.2 Page 6 of 14 EUT Internal Photos Model: AURORA V2.2 Page 7 of 14 EUT Internal Photos Model: AURORA V2.2 Page 8 of 14 EUT Internal Photos Model: AURORA V2.2 Page 9 of 14 EUT Internal Photos Model: AURORA V2.2 Page 10 of 14 Antenna EUT Internal Photos Model: AURORA V2.2 Page 11 of 14 EUT Internal Photos Model: AURORA V2.2 Page 12 of 14 EUT Internal Photos Model: AURORA V2.2 Page 13 of 14 EUT Internal Photos Model: AURORA V2.2 Page 14 of 14 EUT Internal Photos

RF Exposure Info

Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 9 FCC Maximum Permissible Exposure (MPE) Estimation Report Report Number:60.790.23.023.01S01Date of Issue:September 12, 2023 Model / HVIN:AURORA V2.2 Product Type:Retail IoT Sensor Applicant:RetailNext Inc. Address:60 S Market St, 3 rd Floor, Suite 310, San Jose, California 95113, United States Manufacturer:Altek Coroporation Address:No.12, Lixing Road, East District, Hsinchu City, Taiwan Test Result:nPositiveoNegative Total pages including Appendices: 9 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 9 1 Table of Contents 1Table of Contents ............................................................................................................................................ 2 2Details about the Test Laboratory .................................................................................................................... 3 3Description of the Equipment Under Test ......................................................................................................... 4 4Test Specifications .......................................................................................................................................... 5 5General Information ......................................................................................................................................... 6 6RF Exposure Requirements............................................................................................................................. 7 7FCC MPE Limits .............................................................................................................................................. 8 8RF Exposure Evaluation (FCC)........................................................................................................................ 9 8.1.1Calculation of Power Density for Single Chain Transmitters ............................................................. 9 8.1.2Calculation of Simultaneous Transmission ....................................................................................... 9 8.1.3Conclusion ...................................................................................................................................... 9 Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 9 2 Details about the Test Laboratory Details about the TestLaboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052 P.R. China Telephone:86 755 8828 6998 Fax:86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CA5009 IC Registration No.: 10320A Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 9 3 Description of the Equipment Under Test Product:Retail IoT Sensor Model no.:AURORA V2.2 Brand name: Hardware Version Identification No. (HVIN) AURORA V2.2 FCC ID:2AFSV-AURORA-V2-2 Options and accessories:N/A Rating:36 – 57 VDC, 15.4W (POE802.3af) RF Transmission Frequency:2402MHz-2480MHz (BLE) 2412MHz-2462MHz for 802.11b/g/n20 (WiFi) 2422MHz-2452MHz for 802.11n40 (WiFi) 5.180GHz~5.240GHz 5.260GHz~5.320GHz 5.500GHz~5.700GHz 5.745GHz~5.825GHz Antenna Type:FPC PIFA AntennaGain: 4.06 dBi max (2.4GHz) Gain: 5.53 dBi max (5GHz) Description of the EUT:The Equipment Under Test (EUT) is a Retail IoT Sensor which support Bluetooth function and Wi-Fi operated at 5GHz and 2.4GHz. NOTE 1: The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. NOTE 2: This report contains a FPC PIFA antenna, and the testing only performed at the antenna support higher gain. Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 9 4 Test Specifications Test Standards ANSI Std C95.1-1992 Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz – 300 GHz.(IEEE Std C95.1-1991) KDB 447498 D01General RF Exposure Guidance v06 Report Number: 60.790.23.023.01S01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, S…

Text truncated - open the document above for the full version.

Test Report

Report Number: 60.790.23.023.01R01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 49 FCC / ISED – TEST REPORT Report Number:60.790.23.023.01R01Date of Issue:September 12, 2023 Model/HVIN:AURORA V2.2 Product Type:Retail IoT Sensor Applicant:RetailNext Inc. Address:60 S Market St, 3 rd Floor, Suite 310, San Jose, California 95113, United States Manufacturer:Altek Coroporation Address:No.12, Lixing Road, East District, Hsinchu City, Taiwan Test Result:nPositiveo Negative Total pages including Appendices: 49 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 60.790.23.023.01R01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 49 1 Table of Contents 1Table of Contents ........................................................................................................................................... 2 2Details about the Test Laboratory ................................................................................................................... 3 3Description of the Equipment Under Test ........................................................................................................ 4 4Summary of Test Standards ........................................................................................................................... 5 5Summary of Test Results ................................................................................................................................ 6 6General Remarks ........................................................................................................................................... 7 7Test Setups .................................................................................................................................................... 8 8Systems Test Configuration .......................................................................................................................... 10 9Technical Requirement ................................................................................................................................. 11 9.1Conducted Emission ............................................................................................................................. 11 9.2Conducted Peak Output Power & EIRP ................................................................................................. 14 9.3Power Spectral Density ......................................................................................................................... 18 9.46 dB Bandwidth ..................................................................................................................................... 21 9.599% bandwidth ..................................................................................................................................... 24 9.6Spurious RF Conducted Emissions ....................................................................................................... 27 9.7Band Edge ............................................................................................................................................ 35 9.8Spurious Radiated Emissions for Transmitter ........................................................................................ 38 10Test Equipment List .................................................................................................................................. 48 11System Measurement Uncertainty............................................................................................................. 49 Report Number: 60.790.23.023.01R01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 49 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name:TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District Shenzhen 518052 P.R. China Telephone:86 755 8828 6998 Fax:86 755 8828 5299 FCCRegistrationNo.:514049 FCC Deignation No.:CN5009 IC Registration No.:10320A ISED CAB Identifier:CN0077 Report Number: 60.790.23.023.01R01 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 49 3 Description of the Equipment Under Test Product:Retail IoT Sensor Model no.:AURORA V2.2 Hardware Version Identification No. (HVIN) AURORA V2.2 Product Marketing Name (PMN)AURORA V2.2 Brand name: FCC ID:2AFSV-AURORA-V2-2 IC:30959-AURORAV22 Rating:36 – 57 VDC, 15.4W (POE802.3af) RF Transmission Frequency:2402MHz-2480MHz No. of Operated Channel:40 Modulation:GFSK Antenna Type:FPC PIFA AntennaGain: 4.06 dBi max (2.4GHz) Description of the EUT:The Equipment Under Test (EUT) is a Retail IoT Sensor which support Bluetooth function and Wi-Fi operat…

Text truncated - open the document above for the full version.

Test Report

Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 88 FCC / ISED – TEST REPORT Report Number:60.790.23.023.01R02Date of Issue:September 12, 2023 Model/HVIN:AURORA V2.2 Product Type:Retail IoT Sensor Applicant:RetailNext Inc. Address:60 S Market St, 3 rd Floor, Suite 310, San Jose, California 95113, United States Manufacturer:Altek Coroporation Address:No.12, Lixing Road, East District, Hsinchu City, Taiwan Test Result:nPositiveo Negative Total pages including Appendices: 88 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 88 1 Table of Contents 1 Table of Contents .............................................................................................................................. 2 2 Details about the Test Laboratory ..................................................................................................... 3 3 Description of the Equipment Under Test .......................................................................................... 4 4 Summary of Test Standards.............................................................................................................. 5 5 Summary of Test Results .................................................................................................................. 6 6 General Remarks .............................................................................................................................. 7 7 Test Setups ....................................................................................................................................... 8 8 Systems Test Configuration ............................................................................................................ 10 9 Technical Requirement ................................................................................................................... 11 9.1 Conducted Output Power & EIRP ............................................................................................ 11 9.2 6dB Bandwidth and 99% Occupied Bandwidth......................................................................... 13 9.3 Power Spectral Density ............................................................................................................ 25 9.4 Spurious RF Conducted Emissions .......................................................................................... 31 9.5 Band Edge Testing .................................................................................................................. 45 9.6 Spurious Radiated Emissions for Transmitter........................................................................... 50 9.7 Conducted Emission ................................................................................................................ 84 10 Test Equipment List ..................................................................................................................... 87 11 System Measurement Uncertainty ............................................................................................... 88 Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 88 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name:TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone:86 755 8828 6998 Fax:86 755 8828 5299 FCC Registration No.: 514049 FCC Deignation No.:CN5009 IC Registration No.:10320A ISED CAB Identifier:CN0077 Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 88 3 Description of the Equipment Under Test Product:Retail IoT Sensor Model no.:AURORA V2.2 Hardware Version Identification No. (HVIN) AURORA V2.2 Product Marketing Name (PMN)AURORA V2.2 Brand name: FCC ID:2AFSV-AURORA-V2-2 IC:30959-AURORAV22 Rating:36 – 57 VDC, 15.4W (POE802.3af) RF Transmission Frequency:2412MHz-2462MHz for 802.11b/g/n20 (WiFi) 2422MHz-2452MHz for 802.11n40 (WiFi) No. of Operated Channel:11 for 802.11b/g/n20 (Wi-Fi) 7 for 802.11n40 (Wi-Fi) Modulation:DSSS, OFDM Antenna Type:FPC PIFA AntennaGain: 4.06 dBi max (2.4GHz) Description of the EUT:The Equipment Under Test (EUT) is a Retail IoT Sensor which support Bluetooth function and Wi-Fi operated at 5GHz and 2.4GHz. Only 2.4GWiFi included in this report. NOTE: 1. The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certificat…

Text truncated - open the document above for the full version.

Test Report

Report Number: 60.790.23.023.01R02 EMC_SZ_FR_23.03 FCC Release 2017-06-20 TÜV SÜD Certification and Te…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mark Jamtgaard
[email protected]8886095877Fax: 8886095877

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]86 755 3332 3281

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.40 GHz - 2.48 GHz2.59 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons to satisfy the requirements of 2.1091. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device operates in 20 MHz and 40MHz bandwidth modes.