Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
23415678 [email protected] www.soundpeatsaudio.com FCC ID:2AFTU-DD009 MADE IN CHINA
Declaration of difference Models :TrueCapsule2, SP1017A, SP1017B, SP1017C, SP1017D, SP1017E, SP1017F, SP1017H,SP1017G,SP1017I FCC ID: 2AFTU-DD009 We Shenzhen Soundsoul Information Technology Co.,Ltd declared that all models are electrically identical , Only the model no and colors are different . ps:The device have left and right earphones ,the left and right earphones are electrically identical. Signature: Company:ShenzhenSoundsoulInformation TechnologyCo.,Ltd
DATE2020/7/24 EquipmentAutorisationDivision FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 FCCID:2AFTU-DD009 ProductName:BluetoothHeadset RequestforConfidentiality PursuanttoSections0.457and0.459ofthecommissionsrules,weherebyrequestthat thefollowingdocumentsbeheldconfidential: (Listherethedocumentsforwhichyouareseekingconfidentiality–forexample...)  Schematics Blockdiagram Operationdescription Thesematerialscontaintradesecretsandproprietaryinformationandarenot customarilyreleasedtothepublic.Thepublicdisclosureofthisinformationmightbe harmfultothecompanyandprovideunjustifiedbenefitstoourcompetitors. <Signature> NameJasonYang TitleManager ApplicantCompanyShenzhenSoundsoulInformationTechnologyCo.,Ltd
DATE:2020/7/24 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 AuthoritytoActasAgent Onourbehalf,IappointQianhaiBlueAsiaofTechnicalServices(Shenzhen)Co.,Ltdand IOTTestCentreofBlueAsiaNo.448BulongRoad,BantianStreet,LonggangDistrict, Shenzhen(NameofAgentcompanynameandaddress)toactasouragentinthe preparationofthisapplicationforequipmentcertification.Icertifythatsubmitted documentsproperlydescribethedeviceorsystemforwhichequipmentcertificationis sought.Ialsocertifythateachunitmanufactured,importedormarketed,asdefinedinthe FederalCommunicationsCommission’sregulationswillhaveaffixedtoitalabelidentical tothatsubmittedforapprovalwiththisapplication. Forinstanceswhereourauthorizedagentsignstheapplicationforcertificationonour behalf,Iacknowledgethatallresponsibilityforcomplyingwiththetermsandconditions forcertification,stillresideswithShenzhenSoundsoulInformation TechnologyCo.,LtdandRoom1308-1309,BuildingB,Huihai Square,ChuangyeRoad,Longhua District,Shenzhen,Guangdong,China(ApplicantNameandaddress) <Signature> NameJasonYang Title Manager ApplicantCompanyShenzhenSoundsoulInformationTechnologyCo.,Ltd
Model No.: TrueCapsule2
15mm Product name : Bluetooth Headset 10 mm Trademark : SOUNDPEATS FCC ID : 2AFTU-DD009 Model: TrueCapsule2
Model No.: TrueCapsule2
Page 1 of3 TEST REPORT Product Name : Bluetooth Headset Brand Mark : SOUNDPEATS Model No. : TrueCapsule2 Extension Model : SP1017A,SP1017B,SP1017C,SP1017D, SP1017E,SP1017F,SP1017H,SP1017G, SP1017I FCC ID : 2AFTU-DD009 Report Number : BLA-EMC-202006-A39-03 Date of Sample Receipt : 2020/6/16 Date of Test : 2020/6/16 to 2020/7/9 Date of Issue : 2020/7/22 Test Standard : 47 CFR Part 1.1307, Part 2.1093, KDB 447498 Test Result : Pass Prepared for: Shenzhen Soundsoul Information Technology Co.,Ltd Room 1308-1309,Building B, HuihaiSquare, Chuangye Road, LonghuaDistrict, Shenzhen, Guangdong, China Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China TEL: +86-755-28682673 FAX: +86-755-28682673 Compiled by: Review by: Approved by: Date: 2020/7/22 Report No.: BLA-EMC-202006-A39-03 Page 2 of3 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 1.1 RF Exposure Compliance Requirement 1.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 1.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation 17  The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Report No.: BLA-EMC-202006-A39-03 Page 3 of3 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 1.1.3 EUT RF EXPOSURE EVALUATION Operational Mode: EDR (8-DPSK worst case) Channel Maximum Peak Conducted Output Power (dBm) Tune up tolerance (dB) Maximum tune-up Power(dBm) Maximum tune-up Power(mW) Calculated value Exclusion threshold 2402MHz 3.53 ±1 4.53 2.84 0.88 3 2441MHz 2.97 ±1 3.97 2.49 0.78 3 2480MHz 2.40 ±1 3.4 2.19 0.69 3 Conclusion: the calculated value ≤3.0, SAR is exempted. ----END OF REPORT---- The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of BlueAsia, this report can’t be reproduced except in full.
Page 1 of88 TEST REPORT Product Name : Bluetooth Headset Brand Mark : SOUNDPEATS Model No. : TrueCapsule2 Extension Model : SP1017A,SP1017B,SP1017C,SP1017D, SP1017E,SP1017F,SP1017H,SP1017G, SP1017I FCC ID : 2AFTU-DD009 Report Number : BLA-EMC-202006-A39-02 Date of Sample Receipt : 2020/6/16 Date of Test : 2020/6/16 to 2020/7/27 Date of Issue : 2020/7/27 Test Standard : 47 CFR Part 15, Subpart C 15.247 Test Result : Pass Prepared for: Shenzhen Soundsoul Information Technology Co.,Ltd Room 1308-1309,Building B,HuihaiSquare,Chuangye Road, LonghuaDistrict,Shenzhen,Guangdong,China Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China TEL: +86-755-28682673 FAX: +86-755-28682673 Compiled by: Review by: Approved by: Date: 2020/7/27 Report No.: BLA-EMC-202006-A39-02 Page 2 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] REPORT REVISE RECORD Version No. Date Description 00 2020/7/27 Original Report No.: BLA-EMC-202006-A39-02 Page 3 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................6 2 GENERAL INFORMATION .........................................................................................................................7 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................7 4 TEST ENVIRONMENT ................................................................................................................................8 5 TEST MODE ................................................................................................................................................8 6 MEASUREMENT UNCERTAINTY ..............................................................................................................8 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................9 8 LABORATORY LOCATION .........................................................................................................................9 9 TEST INSTRUMENTS LIST ..................................................................................................................... 10 1 ANTENNA REQUIREMENT ..................................................................................................................... 14 1.1 CONCLUSION ............................................................................................................................................................ 14 2 CONDUCTED SPURIOUS EMISSIONS .................................................................................................. 15 2.1 LIMITS ................................................................................................................................................................... 15 2.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 15 2.3 TEST DATA .............................................................................................................................................................. 16 3 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS................................................. 17 3.1 LIMITS ................................................................................................................................................................... 17 3.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 18 3.3 PROCEDURE .......................................................................................................................................................... 18 3.4 TEST DATA .............................................................................................................................................................. 20 4 CONDUCTED BAND EDGES MEASUREMENT ..................................................................................... 24 4.1 LIMITS ................................................................................................................................................................... 24 4.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 24 4.3 TEST DATA .............................................................................................................................................................. 25 5 DWELL TIME ............................................................................................................................................ 26 5.1 LIMITS ................................................................................................................................................................... 26 5.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 26 5.3 TEST DATA .............................................................................................................................................................. 26 6 HOPPING CHANNEL NUMBER .............................................................................................................…
Text truncated - open the document above for the full version.
Report No.: BLA-EMC-202006-A39-02 Page 34 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 10.4 TEST DATA [TestMode: TX]; [Line: Line] Power:AC120V/60Hz Test Result: Pass Report No.: BLA-EMC-202006-A39-02 Page 35 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] [TestMode: TX]; [Line: Nutral] Power:AC120V/60Hz Test Result: Pass Report No.: BLA-EMC-202006-A39-02 Page 36 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 11 RADIATED SPURIOUS EMISSIONS Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 6.4,6.5,6.6 Test Mode (Pre-Scan) TX Test Mode (Final Test) TX Tester Eason Temperature 26°C Humidity 54% 11.1 LIMITS Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.490 2400/F(kHz) 300 0.490-1.705 24000/F(kHz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Remark: The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. Report No.: BLA-EMC-202006-A39-02 Page 37 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 11.2 BLOCK DIAGRAM OF TEST SETUP 11.3 PROCEDURE a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. c. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. d. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. Report No.: BLA-EMC-202006-A39-02 Page 38 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] h. Test the EUT in the lowest channel, the middle channel, the Highest channel. i. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and found the X axis positioning which it is the worst case. j. Repeat above procedures until all frequencies measured was complete. Remark: 1) For emission below 1GHz, through pre-scan found the worst case is the lowest channel. Only the worst case is recorded in the report. 2) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic equation with a sample calculation is as follows: Final Test Level =Receiver Reading + Antenna Factor + Cable Factor ̈C Preamplifier Factor 3) Scan from 9kHz to 25GHz, the disturbance above 7GHz and below 30MHz was very low. The points marked on above plots are the highest emissions could be found when testing, so only above points had been displayed. The amplitude of spurious emissions from the radiator which are attenuated more than 20dB below the limit need not be reported. 4) For frequencies above 1GHz, the field strength limits are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For the emissions whose peak level is lower than the average limit, only the peak measurement is shown in the report. Report No.: BLA-EMC-202006-A39-02 Page 39 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 11.4 TEST DATA [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202006-A39-02 Page 40 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road,…
Text truncated - open the document above for the full version.
Report No.: BLA-EMC-202006-A39-02 Page 67 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Test Graphs DH1_Ant1_2402_0~Reference DH1_Ant1_2402_30~1000 DH1_Ant1_2402_1000~26500 DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 68 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] DH1_Ant1_2441_30~1000 DH1_Ant1_2441_1000~26500 DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 69 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] DH1_Ant1_2480_30~1000 DH1_Ant1_2480_1000~26500 2DH1_Ant1_2402_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 70 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2402_30~1000 2DH1_Ant1_2402_1000~26500 2DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 71 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2441_30~1000 2DH1_Ant1_2441_1000~26500 2DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 72 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2480_30~1000 2DH1_Ant1_2480_1000~26500 3DH1_Ant1_2402_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 73 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_2402_30~1000 3DH1_Ant1_2402_1000~26500 3DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 74 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_2441_30~1000 3DH1_Ant1_2441_1000~26500 3DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202006-A39-02 Page 75 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_2480_30~1000 3DH1_Ant1_2480_1000~26500 Report No.: BLA-EMC-202006-A39-02 Page 76 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] APPENDIX A: PHOTOGRAPHS OF TEST SETUP Radiated Spurious Emissions Report No.: BLA-EMC-202006-A39-02 Page 77 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Conducted Emissions at AC Power Line (150kHz-30MHz) Report No.: BLA-EMC-202006-A39-02 Page 78 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] APPENDIX B: PHOTOGRAPHS OF EUT Report No.: BLA-EMC-202006-A39-02 Page 79 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 80 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 81 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 82 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 83 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 84 of88 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Report No.: BLA-EMC-202006-A39-02 Page 85 of88 BlueAsia of Technical S…
Text truncated - open the document above for the full version.
Model No.: TrueCapsule2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.25 mW |

Wireless Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
bluetooth headset
Equipment Class
DTS - Digital Transmission System
Wireless Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter