FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Baicells Technologies Co., Ltd./
  3. 2AG32EG7010CM11

2AG32EG7010CM11LTE Outdoor CPE

Baicells Technologies Co., Ltd.
LTE Outdoor CPE - FCC ID 2AG32EG7010CM11 - Baicells Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
CBD - Citizens Band Category A and B Devices
Date of Grant
Jan 12, 2020
Application Purpose
Original Equipment
Date of Application
Nov 04, 2019
Equipment Note
LTE Outdoor CPE
Frequency Range
3560.00000000 - 3690.00000000
Company
Baicells Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

01 All rights reserved © Baicells Technologies Co., Ltd. ATOM OD06 - EG7010C-M11 USER Manual 2 1. Shipping List Make sure you have got the following parts: EG7010C Quick Guide PoE Adapter Power Cord Standard Mounting Kits Optional Mounting Kits 2. Hardware Introduction 2.1 Indicators Identity Description Color Status Description MIU - Yellow OFF Reserved. Steady On Reserved. Blanking Reserved. LTE Network state Indicator Blue OFF LTE disconnected. Steady On LTE connected. SIM SIM card status indicator Yellow Steady On The SIM card is normal. Blanking The SIM card is abnormal or not inserted. LAN 100Mbps Eth Indication Yellow OFF Ethernet connection does not established. Steady On Ethernet connection is normal. Blanking Data is transmitting. PWR Power Indicator Yellow OFF No Power Supply Steady On Power On LTE Signal 5 LTEs, Indicate Green All OFF Signal is too weak to attach. Steady On According to signal strength in turn light Identity Description Color Status Description connection state and signal strength up Blanking Scanning the LTE network The CPE is authenticating. CPE is getting IP address from the LTE network. 2.2 Interface and Buttons Interface & Button Description PoE Connected to the PoE Power Adapter TF Support SD card SIM Support 1.8V/3.0V USIM 2FF RESET Long press over 10 seconds to restore the factory settings GND Connected to Earth by conductor 3. Installation Guide 3.1 Support Materials Before installation, prepare the following support materials accordingly, as given below: Item Description Ethernet cable Outdoor Shield CAT5E Shorter than 330 feet Ground wire 16mm² yellow-green wire 3.2 Install USIM Card and Cables (1) Screw the screw on the waterproof cover, and open the waterproof cover (2) Insert the USIM card to the USIM slot. Note following the directions (3) Connect the Ethernet cable to the PoE port (4) connect the ground cable to the ground screw (5) Close the waterproof cover and fasten the screw on the cover. (6) Connected Ethernet cable to the power adapter. Pay attention to the power adapter interface directions. (7) Power on, the LED indicator will light up. 4. Configuration Guide 4.1 4.1 Login The CPE manages, configures, and maintains the device by web management page. The steps to log in are as follows: 1. In the address column of browser, type in http://192.168.150.1, then press “Enter”: 2. Enter the user name and password, click "LOGIN". After password authentication, you can log on to the web management page. The default user name and password is admin. For security, it is recommended that you open the firewall, and keep your login password, WLAN FTP passwords and password well. 4.2 View Status In the overview area, you can view the device information and LTE status,such as Product name, Software version, PLMN, IMSI, RSRP, RSRQ, CINR, SINR, Tx Power, Cell ID, PCI, and so on, as shown below: 5. Specifications Basic Specifications Item Description UE-Category 3GPP R10, CAT 6/7 USIM Slot 1.8V/3.0V USIM 2FF Ethernet Port 1 RJ45, LAN, 10/100/1000 auto-sensing, auto-MDX, PoE Power Supply Input: Universal range 100V~240V AC Output: PoE (24V DC, 0.5A) Reset Button Tactile button. Long press over 10s to restore the factory settings LED Indicators MIU/LTE/SIM/LAN/PWR/LTE Signal Dimensions 241mm (H) x 154mm (W) x 50mm (D) Weight About 900 g LTE Specifications Item Description LTE Mode LTE-TDD LTE Bands Band 48 TXRX 2T4R Channel Bandwidth 5MHz, 10MHz, 15MHz, 20MHz Modulation QPSK, 16QAM Receive Sensitivity -94dBm @ QPSK,20MHz, 25°C MAX Output Power 26dBm Antenna Type Internal directional-antenna Antenna Gain [email protected], 2 Ports Polarization ±45° Antenna Efficiency >70% Isolation ≤-25dB VSWR ≤2 Horizontal Beam Width (3dB) 60±3°@3.xGHz, 2 Ports Vertical Beam Width (3dB) 25±5°@3.xGHz, 2 Ports SW Specifications Item Description Language Support English/Chinese Network Mode NAT/Bridge/Tunnel IP Protocol IPv4/IPv6 SIM Management PIN Management, SIM Lock Network Connection Management Auto/Manual LTE Scan Mode Full band scan, Frequency Lock WLAN WPS MSSID Isolation VLAN VPN  L2TP  GRE NAT  Port forwarding  DMZ  ALG  Port Trigger Firewall  IP/MAC/URL Filter  Access Control  Block Port Scanner / SYN Flood  SPI Filter Network Management  TR069  SNMP Diagnostics  TCPDump  Ping  Trace route Statistics  LTE Status/Connection Time/System Up Time  Device Status  DHCP Client List  WiFi Station List  LTE Status  Firewall Status Maintenance  Date & Time setting  Reboot  Restore factory settings  Restore / Back up configuration file  Firmware upgrade locally/OTA (over the air) System Log  Operating Log  Run-time Log  Filter/Select/Display/Export Log Environmental Specifications Item Description Operating Temperature -40°C to 55°C Storage Temperature -40°C to 70°C Item Description Operating Humidity 5% to 95% Ingress Protection Rating IP65 1 6. Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the…

Text truncated - open the document above for the full version.

Cover Letter(s)

Baicells Technologies Co., Ltd. Date: Oct. 30, 2019 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AG32EG7010CM11 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description Schematics.pdf Block Diagram.pdf Operational Description.pdf Part List Tune-up Procedure Part List.pdf Tune-up Procedure.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Baicells Technologies Co., Ltd. Signature Back Huang/ Manager Typed name and Title

Cover Letter(s)

Baicells Technologies Co., Ltd. Date: 10/30/2019 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD To Whom It May Concern: We, Baicells Technologies Co., Ltd., state that our device, FCC ID: 2AG32EG7010CM11, has a non-removable rear cover. The label will be placed on the rear cover. And the label will be visible to the end users when they purchase the product. The back cover can not be moved away, so the FCC ID label has to be placed on the surface of product. Sincerely, Signature [Back Huang (Name)] [Manager(Title)] [Baicells Technologies Co., Ltd. (Company name)]

Cover Letter(s)

Baicells Technologies Co., Ltd. FCC ID: 2AG32EG7010CM11 POWER OF ATTORNEY Date: Oct. 30, 2019 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Oct. 29, 2020. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Baicells Technologies Co., Ltd. are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Baicells Technologies Co., Ltd. Signature Back Huang / Manager Typed name and Title

Cover Letter(s)

Waltek Services (Shenzhen) Co., Ltd. PAG Permission Letter FCC ID: 2AG32EG7010CM11 Date: 2019/10/30 To whom it may concern: We, the undersigned, hereby authorize Timco Engineering, Inc. to act on our behalf, as our agent, in the following matters related to submit a PAG Filing as Part 96 required. Any act carried out by Timco Engineering, Inc. within the scope of this authorization shall have the same effects as our own. This authorization shall expire 8 months from original date. Sincerely, Name/Title: Philo Zhong/Manager Company name: Waltek Services (Shenzhen) Co., Ltd.

External Photos

Appendix-EG7010C-M11_Photo Page 3 of 11 EUT – External View Model EG7010C-M11 FCC ID: 2AG32EG7010CM11 Appendix-EG7010C-M11_Photo Page 4 of 11 Appendix-EG7010C-M11_Photo Page 5 of 11 Appendix-EG7010C-M11_Photo Page 6 of 11 Appendix-EG7010C-M11_Photo Page 7 of 11

ID Label/Location Info

EG7010C-M11 _Label Sample and Label Location

Internal Photos

Appendix-EG7010C-M11_Photo Page 8 of 11 EUT – Internal View Model EG7010C-M11 FCC ID: 2AG32EG7010CM11 ANT Appendix-EG7010C-M11_Photo Page 9 of 11 Appendix-EG7010C-M11_Photo Page 10 of 11 Appendix-EG7010C-M11_Photo Page 11 of 11 ======End======

RF Exposure Info

Reference No.: WTS19S10068893W002 V1 Page 1 of 7 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn TEST REPORT Reference No. .................... : WTS19S10068893W002 V1 FCC ID ................................ : 2AG32EG7010CM11 Applicant ............................ : Baicells Technologies Co., Ltd. Address .............................. : 3F, Hui Yuan Development Building, No.1 Shangdi Information Industr y Base, Haidian Dist., Beijing, China Manufacturer .................... : Baicells Technologies Co., Ltd. Address .............................. : 3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist., Beijing, China Product ............................... : LTE Outdoor CPE Model(s). ............................ : EG7010C-M11 Brand Name ....................... : BaiCells Standards........................... : FCC 1.1307 Date of Receipt sample .... : 2019-10-08 Date of Test ....................... : 2019-10-09 to 2019-10-21 Date of Issue ...................... : 2020-01-06 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Ford Wang / Project Engineer Philo Zhong / Manager Reference No.: WTS19S10068893W002 V1 Page 2 of 7 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................................ 2 3 REVISION HISTORY ............................................................................................................................................ 3 4 GENERAL INFORMATION .................................................................................................................................. 4 4.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................ 4 4.2 DETAILS OF E.U.T. ......................................................................................................................................... 4 4.3 TEST FACILITY ................................................................................................................................................. 4 5 TEST SUMMARY .................................................................................................................................................. 5 6 RF EXPOSURE ...................................................................................................................................................... 6 6.1 REQUIREMENTS ............................................................................................................................................... 6 6.2 THE PROCEDURES / LIMIT ................................................................................................................................ 6 6.3 MPE CALCULATION METHOD ......................................................................................................................... 7 Reference No.: WTS19S10068893W002 V1 Page 3 of 7 3 Revision History Test report No. Date of Receipt sample Date of Test Date of Issue Purpose Comment Approved WTS19S10068 893W002 V1 2019-10-08 2019-10-09 to 2019-10-21 2020-01-06 original - Valid Reference No.: WTS19S10068893W002 V1 Page 4 of 7 4 General Information 4.1 General Description of E.U.T. Product: LTE Outdoor CPE Model(s): EG7010C-M11 Model Description: NA Storage Location: Internal Storage 4.2 Details of E.U.T. Operation Frequency: LTE Band 48:3550MHz-3700MHz Type of Modulation: LTE: QPSK, 16QAM Antenna installation: LTE: Internal antenna Antenna Gain: 11dbi Ratings: DC 24V 0.5A 4.3 Test Facility The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Services(Shenzhen) Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Services(Shenzhen) Co., Ltd. EMC Laboratory `has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration number 523476, September 10, 2019. Reference No.: WTS19S10068893W002 V1 Page 5 of 7 5 Test Summary Test Items Test Requirement Result Maximum Permissible Exposure (Exposure of Humans to RF Fields) 1.1307(b)(1) PASS Reference No.: WTS19S10068893W002 V1 Page 6 of 7 6 RF Exposure Test Requirement: FCC Part 1.1307 Test Mode: The EUT work in test mode(Tx). 6.1 Requirements Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2m normally can be maintained between the user and the device. 6.2 The procedures / limit FCC Part 1.1307: (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Avera…

Text truncated - open the document above for the full version.

Test Report

DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 2515bRCB.002 09-12-2019 Test report No: NIE: 2515bRCB.002 Test report Citizen Broadband Radio Service Test report Identification of item tested Citizens Based Category A and B Devices Trademark Baicells Model and /or type reference EG7010C-M11 Other identification of the product FCC ID: 2AG32EG7010CM11 Features ---- Manufacturer Baicells Technologies Co., Ltd. 3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist., Beijing, PR China, 100085. Final HW version A Final SW version CPE: BaiCE_BG_1.2.1 Domain Proxy: BaiOMC Rev-18822 Summary IN COMPLIANCE Approved by (name / position & signature) Domingo Gálvez Dueñas (Lab Manager) Date of issue 09-12-2019 Report template No FDT08_22 DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 2515bRCB.002 Page 2 of 14 09-12-2019 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Uncertainty ................................................................................................................................. 4 Data provided by the client .......................................................................................................... 4 Usage of samples ....................................................................................................................... 4 Identification of the client............................................................................................................. 4 Testing period and place ............................................................................................................. 4 Document history ........................................................................................................................ 4 Remarks and comments ............................................................................................................. 4 Testing verdicts ........................................................................................................................... 5 Summary .................................................................................................................................... 5 Appendix A: Test Results ............................................................................................................ 6 Appendix B: Test Systems .......................................................................................................... 9 Appendix C: DUT Photographs ................................................................................................. 10 Appendix D: CBSD/ DP Supported Features ............................................................................ 11 Appendix E: Reference Standards and Procedures .................................................................. 12 Appendix F: Test case descriptions, parameters and test steps ................................................ 14 DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 2515bRCB.002 Page 3 of 14 09-12-2019 Competences and guarantees DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory Accreditation), to perform the tests indicated in the Certificate 2764.01. DEKRA Certification, Inc. is a CBRS Alliance authorized test laboratory. DEKRA Certification, Inc. is a WInnForum Approved CBSD test laboratory. In order to assure the traceability to other national and international laboratories, DEKRA Certification, Inc. has a calibration and maintenance program for its measurement equipment. DEKRA Certification, Inc. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Certification, Inc. at the time of performance of the test. DEKRA Certification, Inc. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Certification, Inc. General conditions 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Certification, Inc. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Certification, Inc and the Accreditation Bodies. DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 2515bRCB.002 Page 4 of 14 09-12-2019 Uncertainty Uncertainty (factor k=2) was calculated according to the DEKRA Certification, Inc internal document PODT000. Data provided by the client DEKRA declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Usage of samples Samples undergoing test have been selected by: Baicells Technologies, Inc. Sample M/02 is composed of the following elements: Control Nº Descripti on Model Serial Nº…

Text truncated - open the document above for the full version.

Test Report

DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 02515BRCB.004 2019-Dec-26 Test report No: NIE: 02515BRCB.004 Test report Test and Certification for Citizens Broadband Radio Service ( CBRS): 940660 D02 CPE-CBSD Handshake Procedures Identification of item tested CBRS CPE-CBSD Trademark Baicells Model and /or type reference EG7010C-M11 Other identification of the product FCC ID: 2AG32EG7010CM11 Features CPE-CBSD with Domain Proxy Final HW Version: A Final SW Version: Domain Proxy:BaiOMC Rev-18822 CPE-CBSD: BaiCE_BG_1.2.1 Manufacturer Baicells Technologies Co., Ltd. 3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist., Beijing, PR China, 100085. Test method requested, standard 940660 D02 CPE-CBSD Handshake Procedures Approved by (name / position & signature) Gonzalo Casado (Lab Manager) Date of issue 2019-Dec-26 Report template No FDT08_22 DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 02515BRCB.004 Page 2 of 31 2019-Dec-26 Index Competences and guarantees ............................................................................................................ 3 General conditions ........................................................................................................................... 3 Abbreviations .................................................................................................................................. 4 Data provided by the client ............................................................................................................... 4 Usage of samples ............................................................................................................................. 4 Identification of the client ................................................................................................................. 4 Testing period and place ................................................................................................................... 4 Document history ............................................................................................................................ 4 Remarks and comments ................................................................................................................... 5 List of equipment used during the test ............................................................................................... 6 Test Setup Diagram ......................................................................................................................... 7 Testing verdicts ............................................................................................................................... 7 Test Results Summary ..................................................................................................................... 7 Appendix A: Test results .................................................................................................................. 8 Appendix C: Test Cases Details ........................................................................................................ 9 Appendix D: Spectrum Analyzer Screenshots .................................................................................. 11 DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 02515BRCB.004 Page 3 of 31 2019-Dec-26 Competences and guarantees DEKRA Certification Inc. is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA Certification has a calibration and maintenance program for its measurement equipment. DEKRA Certification guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Certification at the time of performance of the test. DEKRA Certification is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Certification. General conditions 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Certification. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Certification and the Accreditation Bodies. DEKRA Certification, Inc 405 Glenn Drive, Suite 12 Sterling · VA 20164 · United States of America Report No: (NIE) 02515BRCB.004 Page 4 of 31 2019-Dec-26 Abbreviations Abbreviation Meaning CBRS Citizens Broadband Radio Services CBSD Citizens Broadband Radio Service Device DP Domain Proxy DUT Device Under Test SAS Spectrum Access System UUT Unit Under Test CPI Certified Professional Installer N/A Not Applicable SA Spectrum Analyzer Data provided by the client DEKRA declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Information provided by the client: HW and SW versions of the equipment under test. Usage of samples Samples undergoing test have been selected by: the client Sample M/01 i…

Text truncated - open the document above for the full version.

Test Report

Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Page 1 of 78 TEST REPORT Reference No. .................... : WTS19S10068893W001 V1 FCC ID ................................ : 2AG32EG7010CM11 Applicant ............................ : Baicells Technologies Co., Ltd. Address .............................. : 3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist., Beijing, China Manufacturer .................... : Baicells Technologies Co., Ltd. Address .............................. : 3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist., Beijing, China Product ............................... : LTE Outdoor CPE Model(s). ............................ : EG7010C-M11 Brand Name ....................... : BaiCells Standards........................... : FCC CFR Title 47 Part 2 FCC CFR Title 47 Part 96 Date of Receipt sample .... : 2019-10-08 Date of Test ....................... : 2019-10-09 to 2019-10-21 Date of Issue ...................... : 2020-01-06 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Ford Wang / Project Engineer Philo Zhong / Manager Reference No.: WTS19S10068893W001 V1 Page 2 of 78 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ...................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................................ 2 3 REVISION HISTORY .............…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Back Huang
[email protected]+86-010-62607100Fax: +86-010-62607100

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]0769-22676998

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
8963.56 GHz - 3.69 GHz3.598 W17M9W7D0.0145 ppm
Confidentiality
Long Term
Grant Notes
Output Power is EIRP. This transmitter operates as a Category B CBSD and is limited to professional installation and outdoor operations. This device must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports LTE of 5, 10, 15 and 20 MHz bandwidth modes for TDD LTE Band 48. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance.

Other Applications from Baicells Technologies Co., Ltd.

NeutrinoE224 - FCC ID 2AG32PBS42020 - Baicells Technologies Co., Ltd.
2AG32PBS42020

NeutrinoE224

Nov 28, 2024

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
5G Indoor CPE - FCC ID 2AG32EG3661MNR6 - Baicells Technologies Co., Ltd.
2AG32EG3661MNR6

5G Indoor CPE

Sep 17, 2024

Equipment Class

6ID - 15E 6 GHz Low Power Indoor Access Point
2AG32BSC7261A249D

Aurora6449m

Apr 15, 2024

Equipment Class

5GB - Part 30 Fixed Transmitter
LTE Indoor CPE - FCC ID 2AG323015MM30HPEUD - Baicells Technologies Co., Ltd.
2AG323015MM30HPEUD

LTE Indoor CPE

Nov 23, 2022

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
LTE Outdoor CPE - FCC ID 2AG328015GM11HPEUD - Baicells Technologies Co., Ltd.
2AG328015GM11HPEUD

LTE Outdoor CPE

Jul 02, 2022

Equipment Class

CBE - Citizens Band End User Devices