INSTRUCTIONS v1.0 Welcome The SLEEPINGACE is an advanced portable and wireless-control sleep helping device. SLEEPINGACE is designed to be used by healthy adults who do not suffer from epilepsy, brain or mental health conditions or using the implanted devices such as cochlea-implant, bone-conductor-implant, cardiac pacemakers, insulin pumps, deep-brain-stimulation. Warning For safety reason, it does NOT recommend the following group of people using SLEEPINGACE until they have had the advice from the medical professional. (i) pregnant women; (ii) children under age 7; (iii) people with high blood pressure; (iv) people using the implanted devices such as cochlea-implant, bone-conductor-implant, cardiac pacemakers, insulin pumps, deep-brain-stimulation; (v) epileptic patients; (vi) people with high risk of stroke. If you experience short term negative effects with SLEEPINGACE you should immediately stop using it. This is not a toy and is not intended to be used by anyone under the age of 18 years old. SLEEPINGACE is neither a medicine nor a medical device. SLEEPINGACE could improve the sleeping status and quality but it is not a medical treatment for insomnia. What you need to understand before using SLEEPINGACE SLEEPINGACE is designed to improve the sleeping status and quality. Possible side effects include tingling sensations under the electrodes or on the scalp, visual artifacts, nausea, headaches or fatigue. If you experience any of these you should stop using SLEEPINGACE. Repeated use may lead to skin irritation. You may feel a tingling sensation, or a hot or cold sensation. If this is uncomfortable or painful then you should stop session and remove the electrodes. Redness may appear under electrodes after use which will disappear after a short time. Foc.us should not be used during any activities other than preparing to sleep. If you see white flashes or phosphenes, that is normal reaction during the stimulation. If the white flashes or phosphenes make you uncomfortable, you should stop using SLEEPINGACE. What is in the box 1. SLEEPINGACE headset 2. SLEEPINGACE remote controller 3. Micro-USB power supply 4. Reusable water bottle 5. Sponges * 8 6. Plastic nail * 8 7. Sponges dock 8. This instruction booklet When do I use SLEEPINGACE It is recommended to use SLEEPINGACE within four hours before you go to sleep. Before Starting 1. Turn on the headset by pressing down the power key for 3 seconds, you will see the power key display blue light. 2. Turn on the remote controller by pressing down the right key for 3 seconds; you will see the welcome screen and all keys display blue light. 3. Check the headset and remote controller have more than 30% power in the remote screen, otherwise the stimulation may be stopped by out of power. Preparing sponges Add a tiny small amount (3~5g) of salt in the included reusable bottle and fill with water to create a saline solution. Put two included sponges into the included sponges dock, wet the sponges using the water bottle until they are saturated but not dripping. Install the two wet sponges into the electrode cups with Plastic nails. Positioning headset Position the SLEEPINGACE headset on your head as the follow figure as a guide. Getting started Turn on the headset and remote controller, and check the headset connection status. Remote will show welcome page for 5 seconds. Headset connection status is normal. Headset connection status is failure. Program selection Click the left key of the remote controller, the remote will show the built-in programs. Program information Use the up or down arrow key of the remote to select the program, click the OK key enter the program. Mild program is low energy level stimulation. Moderate program is medium energy level stimulation. Severe program is high energy level stimulation. Setting is function to reset the date and time configuration of remote controller. Program started Press the OK key to start the program, or press the right key to return. Program start to do the impedance test, the number in the center will count down to 0. The test is to check the sponges having a good contact to the head. Impedance test process All thing are right, the test will be passed. If sponges do not have a good contact to the head, the test will be failed. You should take off the headset, add more water to sponges and do the test again. Program running When the impedance test is passed, you press OK key to activate the stimulation program. Program stop During the stimulation, you can press OK key to stop. You can press OK key to resume the stimulation, also you can press right key to go back program selection screen. Setting When you select setting option in the program screen, and press OK key then entering the setting screen. You can reset the Date & Time in this screen. Use the arrow key to move and adjust the value, when you finish the reset then press the right key to go back to the program selection screen. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. This device complie…
Text truncated - open the document above for the full version.
Advance Electronic & Medical Industries Co., Ltd. Letter of Authorization Company: Advance Electronic & Medical Industries Co., Ltd. Address: Room 519, 5/F, Yick Tai Industrial Building, 650 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong SAR. Product Name: SLEEPINGACE Model Number: SLEEPINGACE V1 FCC Identifier: 2AG48-001 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Steven Date: 05 January 2015 Title: Manager Signature of applicant:
Advance Electronic & Medical Industries Co., Ltd. 1/5/2016 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Request for Confidentiality Company name: <Advance Electronic & Medical Industries Co., Ltd.> FCC ID: 2AG48-001 FCC Part 15 Certification Gentlemen, Pursuant to 47 CFR 0.457(d)(1)(ii) and 0.459 < Advance Electronic & Medical Industries Co., Ltd.> hereby requests permanent confidentiality of the following documents for the subject application: Exhibit Type File Name Description Block Diagram Block Diagram Block Diagram Operational Description Operational Description Operational Description Schematics Schematics Schematics Parts / BOM Parts / BOM List Parts / BOM List Note: Any exhibit NOT granted Confidential status is viewable on the FCC website as soon as the Grant is issued. Reason why the material should be withheld from public inspection: These documents contain detailed system, equipment description and related information about the product which < Advance Electronic & Medical Industries Co., Ltd.> considers proprietary, confidential, and a custom design not otherwise available to the general public. State why the information is a “trade secret;” Since the design is a basis from which future products will evolve, < Advance Electronic & Medical Industries Co., Ltd.> considers that this information would be of significant benefit to its competitors and that disclosure would give competitors an unfair advantage in the marketplace. Trade secret” information is information which is not generally known or reasonably ascertainable, by which a business can obtain an economic advantage over competitors. The information is not normally released to any party or person outside the company. Sincerely, Signature: Name: Steven Company: Advance Electronic & Medical Industries Co., Ltd. Title: Manager Date: 05 January 2015
FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 1 of 3 1.External Photos of the EUT External view-1 External view-2 External view-3 FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 2 of 3 External view-4 External view-5 External view-6 FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 3 of 3 External view-7 Adapter Label
FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 1 of 1 LABEL PHOTOGRAPHS Label Location 5MM 15MM
FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 1 of 5 1. Internal Photos of the EUT PCB 1 side 1 view PCB 1 side 2 view FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 2 of 5 PCB 2 side 1 view PCB 2 side 2 view FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 3 of 5 Module side 1 view Module side 2 view FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 4 of 5 Oscillator 1 view Oscillator 2 view FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 5 of 5 Battery view
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3151021-01188-EF CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 1 of 27 TEST REPORT For FCC ID 47 CFR PART 15 OCT, 2014 Report Reference No. .................... CGZ3151021-01188-EF Date of issue..................................... 06 November 2015 Testing Laboratory Name .............. CENTRE OF TESTING SERVICE CO., LTD. Address............................................. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Testing location/ procedure .............. Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s name ............................ Advance Electronic & Medical Industries Co., Ltd. Address............................................. Room 519, 5/F, Yick Tai Industrial Building, 650 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong SAR. Test specification ........................... Standard ........................................... 47 CFR PART 15 OCT, 2014 Test Report Form No. ....................CTSEMC-1.0 TRF Originator.................................. CENTRE OF TESTING SERVICE CO., LTD. Master TRF .......................................Dated 2009-01 CENTRE OF TESTING SERVICE CO., LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the CENTRE OF TESTING SERVICE CO., LTD is acknowledged as copyright owner and source of the material. CENTRE OF TESTING SERVICE CO., LTD takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description.....................:SLEEPINGACE Trade Mark....................................... SLEEPINGACE Manufacturer.................................... Advance Electronic & Medical Industries Co., Ltd. Model/Type reference...................... SLEEPINGACE V1 Ratings............................................. Battery 3.7V, DC 5V for Charging by adapter; Adapter Input:AC 100~240V, 50/60Hz; Output:DC 5V Operating Frequency ........................ 2402.0MHz ~2480.0MHz Result ............................................... Positive Compiled by: Supervised by: Approved by: Kate zhang / Fileadministrators Duke yang / Technique principal Vincent yao / Manager FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 2 of 27 FCC ID -- T E S T R E P O R T Test Report No. : CGZ3151021-01188-EF 06 November 2015 Date of issue Type / Model............................ SLEEPINGACE V1 EUT.......................................... SLEEPINGACE Applicant........................... Advance Electronic & Medical Industries Co., Ltd. Address.................................... Room 519, 5/F, Yick Tai Industrial Building, 650 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong SAR. Telephone................................ / Fax........................................... / Contact..................................... Steven Manufacturer...................... Advance Electronic & Medical Industries Co., Ltd. Address.................................... Room 519, 5/F, Yick Tai Industrial Building, 650 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong SAR. Telephone................................ / Fax........................................... / Contact..................................... Steven Test report holder................ Advance Electronic & Medical Industries Co., Ltd. Address.................................... Room 519, 5/F, Yick Tai Industrial Building, 650 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong SAR. Telephone................................ / Fax........................................... / Contact..................................... Steven Test Result according to the standards on page 1:PASSED The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 3 of 27 TABLE OF CONTENTS Description Page 1.TEST STANDARDS........................................................................................................................................5 2.SUMMARY......................................................................................................................................................5 2.1 GENERAL REMARKS .......................................................................................................................................5 2…
Text truncated - open the document above for the full version.
FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 1 of 2 TEST PHOTOGRAPHS 1. Photos of TX Radiated Emission Test (In Anechoic Chamber) 9KHz~30MHz 30MHz-1GHz Above 1GHz FCC ID:2AG48-001 Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3151021-01188-EF Page 2 of 2 2. Band Edge Compliance Test 3. Photos of Conduction Emission Test
A101, No 65 Zhiji Highway, Tianhe District · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |