Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SuperPod Aon Model: G2A/G2J/G2E/G2U Plume Instruction Manual Welcome to WorkPass by Plume! This short informative guide will familiarize you with the Plume Pod(s) setup. Additional help is available on Plume’s website at https://support.plume.com/ hc/en-us Getting Started Before you use the Pod, please download the WorkPass by Plume app to your smartphone and follow the in-app 2-minute setup guide. The WorkPass by Plume app can be downloaded on: •App Store - iOS •Google Play - Android Step 1 Once the WorkPass by Plume is downloaded and successfully installed. TAP “Set up WorkPass” from the landing page If you are having trouble, please contact us at: https://support.plume.com/hc/ en-us Step 2 Create your account: Enter your name and location name and tap “Next” Step 3 Enter your email and password and tap “Next” Step 4 Connect modem to the left ethernet port on the pod. Plug pod into power. Restart the modem Step 7 Setup secure Wi-Fi network name and password Step 8 Setup employee Wi-Fi network name and password Step 9 Setup guest Wi-Fi network name and password and simply tap “Next” to set three Plume networks Step 8 Once all three networks are created connect all rest of the pods Compliance LEGAL • Terms of use, privacy policy and terms of sale can be found at: www.plumewifi.com/ legal • Regulatory compliance information, including EU and FCC Declaration of Conformity can be found at: https://www.plume.com/legal/regulatory/ SAFETY • ALWAYS READ THE ONLINE USER MANUAL BEFORE SET UP OR USE. • IT IS YOUR RESPONSIBILITY TO FAMILIARIZE YOURSELF WITH THE ONLINE USER MANUAL AND WARNINGS, AND TO USE THE DEVICE PROPERLY. • To prevent fire or electric shock hazard, keep away from rain or moisture. Clean only with a clean, dry cloth. • Do not connect the plug into an extension cord, receptacle, or other outlet unless the plug can be fully inserted with no part of the blades exposed. • The socket-outlet shall be installed near the equipment and shall be easily accessible. • Do not cover the device or block the airflow to the device. Do not expose device to temperatures below freezing or above 95°F. • Device may contain small parts and be otherwise hazardous to children. Keep out of reach of children. • If the device malfunctions or fails to perform as expected, stop using it immediately. • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. • Double Insulation This symbol indicates that this product incorporates double insulation between hazardous mains voltage and user accessible parts. Earthing wire is therefore not necessary. • For indoor use only This equipment may only be operated indoors. Operation outdoors is in violation of 47 U.S.C. 301 and could subject the operator to serious legal penalties. Product Information FCC Regulations: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; 5GHz band (W52,W53): Indoor use only (Except for the transmission with High Power Data Communication System Base Station or Relay Station) 日文版: 5.2/5.3GHz 屋内使用限 定 (5.2GHz登録局との通信を除く) FCC RF Exposure Compliance This equipment complies with radio frequency (RF) exposure limits adopted by the Federal Communications Commission for an uncontrolled environment. This equipment should be installed and operated to ensure a minimum of 25 cm spacing to any person at all times. Your Plume Pod information is on file with FCC and can be found on FCC website http://www.fcc.gov/oet/ea/ by searching the FCC ID on the device, which can be found on the bottom of the Plume Pod. ISED Regulations: This device complies with ISED applicable license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux normes RSS pour les dispositifs exempts de licen…
Text truncated - open the document above for the full version.
Plume Design, Inc.! 325 Lytton Ave., Palo Alto, CA 94301 Date: 2023/03/21 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i)-(ii) (KDB 986446 D01 Covered Equipment) Plume Design, Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Plume Design, Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List maintained pursuant to 47 C.F.R. § 1.50002 as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: FCC ID: 2AG7G-G2A If you have any questions, please feel free to contact me. Applicant’s Authorized Signature: ___________________________ Name: Nora Huen Ching, Yan Title: Director of HW Engineering, TW Date of Signature: 2023/03/21 Company Name: Plume Design, Inc. Tel: 1(408)8387537 E-Mail: [email protected]
Plume Design, Inc. 325 Lytton Ave., Palo Alto, CA 94301 Date: 2023/04/27 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Certification Designating a U.S. Agent for Service of Process Ref: Section 2.911(d)(7) filing FCC ID: 2AG7G-G2A Plume Design, Inc. as required by 47 C.F.R. § 2.911(d)(7), has designated itself as the agent for service of process for matters related to the applicable equipment for the above referenced FCC ID. Plume Design, Inc. acknowledges and accepts the obligation to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Plume Design, Inc. further acknowledges its responsibility to inform the FCC whenever the agent information changes. Applicant/Designated U.S. Agent: Plume Design, Inc. Contact Person: Shari Pire Company Address: 325 Lytton Ave., Palo Alto, CA 94301, United States Email: [email protected] Telephone: 1(408)838-7537 FCC Registration Number: 0025181934 Applicant/Designated U.S. Agent Authorized Signature: Name: Shari Pire Date: 2023/04/27 DocuSign Envelope ID: C1F3D72C-9C8F-4CE3-9E4A-564AC99C8761
Plume Design, Inc .! 325 Lytton Ave., Palo Alto, CA 94301 Date: March 21, 2023 Power of Attorney To whom it may concern, Please be notified that we, Plume Design, Inc., have assigned William Chung in Eurofins E&E Wireless Taiwan Co., Ltd. as our agent with respect to the FCC certification of the product listed below. and to sign the form 731 and other documentation. Any and all acts carried out by William Chung in Eurofins E&E Wireless Taiwan Co., Ltd. for FCC approval of the product listed below, and any communication needed with the national au- thority, shall have the same legal authority as acts performed by us directly. We further certify that neither the applicant nor any party to this application, as defined in 47 CFR Ch. 1.2002 (b), is subject to a denial to Federal benefits, that include FCC benefits, pursu- ant to section 5301 of the Anti-Drug Abuse Act of 1998, 21 U.S.C. 862. This authorization is limited to the following product: FCC ID: 2AG7G-G2A We confirm our acknowledgement by signing below. For any inquiries, please contact Eurofins E&E Wireless Taiwan Co., Ltd. directly by email to William Chung at Williamchung@eu- rofins.com. Sincerely yours, ________________________ Contact Person: Nora Huen Ching Yan Applicant: Plume Design, Inc. Tel: 1(408)8387537 E-Mail: [email protected]
Plume Design, Inc. 325 Lytton Ave., Palo Alto, CA 94301 March 21, 2023 FCC Laboratory 7435 Oakland Mills Rd Columbia MD 21046 Request for Confidentiality FCC ID: 2AG7G-G2A To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of the Federal Communications Commission (the “Commission”) rules (47CFR§§0.457, 0.459), Plume Design, Inc. (“Plume”) respectfully requests that the Commission withhold the following documents from public disclosure indefinitely. ● Schematic Diagram ● Block Diagram ● Operational Description ● Software Security UNII Declaration The above-mentioned documents contain detailed system and equipment descriptions and constitute proprietary information related to the operation of the equipment. The public disclosure of the above documents could be harmful to Plume and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, Plume respectfully requests that the Commission withhold the following documents for 180 days after the grant of equipment authorization is issued: ● External Photos ● Internal Photos ● Test Setup Photos ● User Manual It is our understanding that all measurement test reports in FCC ID label format cannot be granted confidential treatment and, therefore, we understand that such information will be available for public review once the grant of equipment authorization is issued. Respectfully Submitted, ______________ Nora Huen Ching Yan [email protected]
22-1906_EUT External Photos Page 1 of 9 External Photos Model Number: G2A 22-1906_EUT External Photos Page 2 of 9 EUT Photo (1) EUT Photo (2) 22-1906_EUT External Photos Page 3 of 9 EUT Photo (3) EUT Photo (4) 22-1906_EUT External Photos Page 4 of 9 EUT Photo (5) EUT Photo (6) 22-1906_EUT External Photos Page 5 of 9 EUT Photo (7) EUT Photo (8) 22-1906_EUT External Photos Page 6 of 9 EUT Photo (9) EUT Photo (10) 22-1906_EUT External Photos Page 7 of 9 EUT Photo (11) EUT Photo (12) 22-1906_EUT External Photos Page 8 of 9 EUT Photo (13) EUT Photo (14) 22-1906_EUT External Photos Page 9 of 9 EUT Photo (15)
22-1906_EUT Internal Photos Page 1 of 19 Internal Photos Model Number: G2A 22-1906_EUT Internal Photos Page 2 of 19 EUT Photo (1) EUT Photo (2) 22-1906_EUT Internal Photos Page 3 of 19 EUT Photo (3) EUT Photo (4) 22-1906_EUT Internal Photos Page 4 of 19 EUT Photo (5) EUT Photo (6) 22-1906_EUT Internal Photos Page 5 of 19 EUT Photo (7) EUT Photo (8) 2G1/5GH1 ANT. BLE/5GL4 ANT. 5GL3 ANT. 5GL2 ANT. 5GL1 ANT. 2G2/5GH2 ANT. 22-1906_EUT Internal Photos Page 6 of 19 EUT Photo (9) EUT Photo (10) 22-1906_EUT Internal Photos Page 7 of 19 EUT Photo (11) EUT Photo (12) Matter ANT. 22-1906_EUT Internal Photos Page 8 of 19 EUT Photo (13) EUT Photo (14) 22-1906_EUT Internal Photos Page 9 of 19 EUT Photo (15) EUT Photo (16) 22-1906_EUT Internal Photos Page 10 of 19 EUT Photo (17) EUT Photo (18) 22-1906_EUT Internal Photos Page 11 of 19 EUT Photo (19) EUT Photo (20) 22-1906_EUT Internal Photos Page 12 of 19 EUT Photo (21) EUT Photo (22) 22-1906_EUT Internal Photos Page 13 of 19 EUT Photo (23) EUT Photo (24) 22-1906_EUT Internal Photos Page 14 of 19 EUT Photo (25) EUT Photo (26) 22-1906_EUT Internal Photos Page 15 of 19 EUT Photo (27) EUT Photo (28) 22-1906_EUT Internal Photos Page 16 of 19 EUT Photo (29) EUT Photo (30) 22-1906_EUT Internal Photos Page 17 of 19 EUT Photo (31) EUT Photo (32) 22-1906_EUT Internal Photos Page 18 of 19 EUT Photo (33) EUT Photo (34) 22-1906_EUT Internal Photos Page 19 of 19 EUT Photo (35) EUT Photo (36)
Page 1 of 11 Report Number: 2303FS15 Version: 00 MPE Report Applicant : Plume Design, Inc. Product Name : SuperPod Aon Trade Name : Plume Design, Inc. Model Number : G2A Applicable Standard : 47 CFR § 2.1091 Received Date : Nov. 23, 2022 Issue Date : Apr. 21, 2023 Issued by Approved By : Eurofins E&E Wireless Taiwan Co., Ltd. No. 140-1, Changan Street, Bade District, Taoyuan City 334025, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Note: 1.The test results are valid only for samples provided by customers and under the test conditions described in this report. 2.This report shall not be reproduced except in full, without the written approval of Eurofins E&E Wireless Taiwan Co., Ltd. 3.The relevant information is provided by customers in this test report. According to the correctness, appropriateness or completeness of the information provided by the customer, if there is any doubt or error in the information which affects the validity of the test results, the laboratory does not take the responsibility. Page 2 of 11 Report Number: 2303FS15 Version: 00 Revision History Rev. Issued Date Revisions Revised By 00 Apr. 21, 2023 Initial Issue Abby Hsu Page 3 of 11 Report Number: 2303FS15 Version: 00 Contents 1. General Information .................................................................................................................... 4 2. Description of Equipment under Test (EUT) ............................................................................ 5 3. RF Exposure Limit ...................................................................................................................... 7 4. RF Exposure Assessment .......................................................................................................... 8 5. Maximum Tune-up Power ......................................................................................................... 10 6. Result ......................................................................................................................................... 10 7. Conclusion ................................................................................................................................. 11 Page 4 of 11 Report Number: 2303FS15 Version: 00 1. General Information 1.1 Reference Applicable Standard Standard Description Version IEEE C95.1 American National Standard safety levels with respect to human exposure to radio frequency electromagnetic fields, 300 KHz to 100 GHz, New York. 1992 47 CFR § 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. - 47 CFR § 1.1310 Radiofrequency radiation exposure limits. - KDB 447498 D04 RF exposure procedures and equipment authorization policies for mobile and portable devices v01 1.2 Testing Location Site Name: Site Name: Eurofins E&E Wireless Taiwan Co., Ltd. Site Address: ▓ No. 140-1, Changan Street, Bade District, Taoyuan City 334025, Taiwan (R.O.C.) Site Address: □ No. 2, Wuquan 5th Rd. Wugu Dist., New Taipei City, Taiwan (R.O.C.) Page 5 of 11 Report Number: 2303FS15 Version: 00 2. Description of Equipment under Test (EUT) Applicant Plume Design, Inc. 325 Lytton Ave., Palo Alto, CA 94301 Product Name SuperPod Aon Trade Name Plume Design, Inc. Model Number G2A FCC ID 2AG7G-G2A Transmitter Modulation Frequency Range (MHz) Number of Channels WLAN 2.4G IEEE 802.11b IEEE 802.11g IEEE 802.11n 20 MHz (64QAM) IEEE 802.11n 20 MHz (256QAM) IEEE 802.11ax 20 MHz 2412 - 2462 11 IEEE 802.11n 40 MHz (64QAM) IEEE 802.11n 40 MHz (256QAM) IEEE 802.11ax 40 MHz 2422 - 2452 9 (WLAN 5G) IEEE 802.11a IEEE 802.11n 5 GHz 20 MHz / IEEE 802.11ac 20 MHz / IEEE 802.11ax 20 MHz U-NII Band I 5180 – 5240 4 U-NII Band II-A 5260 – 5320 4 U-NII Band II-C 5500 – 5720 12 U-NII Band III 5745 – 5825 5 IEEE 802.11n 5 GHz 40 MHz / IEEE 802.11ac 40 MHz / IEEE 802.11ax 40 MHz / U-NII Band I 5190 – 5230 2 U-NII Band II-A 5270 – 5310 2 U-NII Band II-C 5510 – 5710 6 U-NII Band III 5755 – 5795 2 IEEE 802.11ac 80 MHz / IEEE 802.11ax 80 MHz / U-NII Band I 5210 1 U-NII Band II-A 5290 1 U-NII Band II-C 5530 – 5690 3 U-NII Band III 5775 1 IEEE 802.11ac 160 MHz / IEEE 802.11ax 160 MHz / U-NII Band I & II-A 5250 1 U-NII Band II-C 5570 1 Bluetooth Low Energy 2402 - 2480 40 SRD Matter 2.4G 2405 – 2480 16 Use Distance 25cm Note: The above information of DUT was declared by manufacturer. Please refer to the specifications or user's manual for more detailed description. Page 6 of 11 Report Number: 2303FS15 Version: 00 2.1 Antenna System Description Ant. Ant. Type Gain (dBi) 2.4GHz 5GHz 6GHz Band I Band II-A Band II-C Band III 1 IFA Antenna 3.50 --- --- 5.90 5.90 --- 2 IFA Antenna 2.70 --- --- 3.80 3.70 --- 3 IFA Antenna --- 4.00 3.30 --- --- --- 4 IFA Antenna --- 2.50 2.40 --- --- --- 5 IFA Antenna --- 3.80 3.80 --- --- --- 6 IFA Antenna --- 3.00 2.40 --- --- --- Specification Ant. 1 Ant. 2 Ant. 3 Ant. 4 Ant. 5 Ant. 6 Remark 2.4G IEEE 802.11 b/g/n/ac/ax V 1X1 IEEE 802.11 b/g/n/ac/ax V V 2x2 5G IEEE 802.11 a/n/ac/ax V 1x1 IEEE 802.11 a/n/ac/ax V V 2x2 IEEE 802.11 a/n/ac/ax V 1x1 IEEE 802.11 a/n/ac/ax V V V V 4x4 Note 1: The above information is provided by customers. Page 7 of 11 Report Number: 2303FS15 Version: 00 3. RF Exposure Limit For devices that operate at larger distances from persons, where there are minimal RF coupling interactions between a device and the user or nearby persons, RF exposure compliance using maximum permissible exposure (MPE) limits is applied. The limits for MPE is listed as below: Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm²) Averaging Time|E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824 / f 2.19 / f (180 / f 2 )* 30 30-300 27.5 0.073 0.2 30 300-1500 - - F / 1,500 30 1,500-100,000 - - 1.0 30 Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Ma…
Text truncated - open the document above for the full version.
Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 1 of 9 Applicant Plume Design, Inc. Product Type SuperPod Aon Model Number G2X, X=A, E, U, R, J. Antenna Report 1. Measurement information - Measurement: Plume HW lab - Equipment: MVG SG24-C chamber , ANRITSU MS46522B VNA * Test Equipment list Description Manufacturer Model S/N Cal Date Network Analyzer ANRITSU MS46522B 1745103/M1:7295 0015 2021-12-10 Probe Array 1.5 meters internal diameter MVG SG24C ATL1602S 2022-02-25 Azimuth Positioner MVG GONI-009/010 0018 N.C.R 1 Note 1: N.C.R. = No Calibration Request. * Test Engineer: Arthur Tung 2. Measurement Standards -Reference: IEEE Std. 149-2021 section 8.4.1 3. Measurement Method 4. EUT set on multi-axis positioner and adjust EUT’s physical center to measurement reference center. Measurement antenna set at phi polarization and 1.5 meters height. Port 1 of Network analyzer connect to antenna 1 of EUT. Record G value every 15 degree from 0 to 345 degree on Phi angle and 0 to 180 on theta of multi-axis positioner. Then set measurement antenna to theta polarization and repeat process. Repeat process to each antenna of EUT. Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 2 of 9 5. Measurement Environment To use anechoic chamber with full 3D far field measurement capability. The detail refers to the Information below. 5.1. Radiation Pattern Test Antennas tested for Gain and Efficiency must be assembled into the enclosure and tested in the fully assembled and operating G2X. The antenna is tested in free space in the full 3D anechoic chamber in the H, E1 and, E2 planes. The radiation patterns are measured at the center of transmit and receive bands. 5.2. Rectangular Fully Anechoic Chamber Shield Dimensions (L x W x H): 3.5 m x 3.5 m x 2.7 m 5.3. Open Boundary 23 Probe Antenna Stargate System Open Boundary 23 Probe Antenna Stargate System is based on positioning 23 waveguide probe antennas positioned 15 degrees apart from each other from 0 degrees to 345 degrees to measure all possible angles of a radiating electric field 5.4. Dual polarized probes The probe aims to measure at a given location in space the value of the electromagnetic field radiated by an antenna under test. Inside SATIMO measurement systems, the probes used are wideband dual polarized passive antennas. Each probe consists in two elementary antennas mounted in cross to collect the electromagnetic field according to two orthogonal polarizations. These probes are entirely reciprocal and can be used both in reception and transmission way. 5.5. Data Acquisition and Analysis Software Satimo WaveStudio and SatEnv Antenna Measurement Software supports data acquisition in either the great circle-cut or conical-cut test sequence to perform full spherical antenna measurements. Post-processing calculations include derivation of antenna half-power beam-width, directivity, gain, radiation efficiency, total radiated power, and total optional isotropic sensitivity. Advanced graphic capabilities allow acquired data to be displayed in a variety of 2D and 3D formats. 5.6. Instrumentation The system is configured to perform generic antenna measurement by using a multi- channel Vector Network Analyzer (VNA). Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 3 of 9 6. Equipment Configuration 6.1. EUT supports bands. Operate Frequency (WLAN 2.4G) Frequency Band Frequency Range (MHz) Number of Channels IEEE 802.11b IEEE 802.11g IEEE 802.11n 20 MHz (64QAM) IEEE 802.11ac 20 MHz (256QAM) IEEE 802.11ax 20 MHz 2412 - 2462 11 IEEE 802.11n 40 MHz (64QAM) IEEE 802.11ac 40 MHz (256QAM) IEEE 802.11ax 40 MHz 2422 - 2452 9 IEEE 802.11a U-NII Band I 5180 – 5240 4 U-NII Band II-A 5260 – 5320 4 IEEE 802.11n 5 GHz 20 MHz / IEEE 802.11ac 20 MHz / U-NII Band II-C 5500 – 5720 12 IEEE 802.11ax 20 MHz U-NII Band III 5745 – 5825 5 Operate Frequency IEEE 802.11n 5 GHz 40 MHz / U-NII Band I 5190 – 5230 2 U-NII Band II-A 5270 – 5310 2 (WLAN 5G) IEEE 802.11ac 40 MHz / U-NII Band II-C 5510 – 5710 6 IEEE 802.11ax 40 MHz / U-NII Band III 5755 – 5795 2 U-NII Band I 5210 1 IEEE 802.11ac 80 MHz / U-NII Band II-A 5290 1 IEEE 802.11ax 80 MHz / U-NII Band II-C 5530 – 5690 3 U-NII Band III 5775 1 IEEE 802.11ac 160MHz / IEEE 802.11ax 160MHz U-NII Band I 5250 1 U-NII Band II-A U-NII Band II-C 5570 1 Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 4 of 9 6.2. EUT Antenna Configuration 6.3. EUT Antenna System Description: Ant. Ant. Type 2G1/5GH1 IFA Antenna 2G2/5GH2 IFA Antenna 5GL1 IFA Antenna 5GL2 IFA Antenna 5GL3 IFA Antenna BLE/5GL4 IFA Antenna Matter IFA Antenna Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 5 of 9 7. Result Summary and Pattern Plots 2.4G 2G Antenna 1(dBi) 2G Antenna 2(dBi) 2420 MHz 3.2 1.5 2450 MHz 3.5 2.2 2480 MHz 2.5 2.7 Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 6 of 9 5GLB 5GL Antenna 1 (dBi) 5GL Antenna 2 (dBi) 5GL Antenna 3 (dBi) 5GL Antenna 4 (dBi) 5100 MHz 4 2.5 3.2 2.9 5200 MHz 3.8 2.2 3.7 3 5250 MHz (Added Point) 3.3 2.2 3.8 2.3 5300 MHz 3.3 2.4 3.7 2.3 Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 7 of 9 5GHB 5GH Antenna 1(dBi) 5GH Antenna 2 (dBi) 5400 MHz 3.3 3.8 5500 MHz 3.6 3.7 5600 MHz 3.8 3.8 5700 MHz 5.5 3.7 5800 MHz 5.7 3.4 5900 MHz 5.9 3.2 Plume Design, Inc 325 Lytton Ave., Palo Alto, CA 94301 Page 8 of 9 Matter Matter (dBi) 2400MHz 0.08 2450MHz 2.62 2500MHz 2.19 BLE BLE (dBi) 2400MHz 0.8 2450MHz 1.7 2500MHz 2.4
Appendix A. Test Data BLE 1M24022.1922.50487.5400.5780.456 Duty Cycle Band Frequency (MHz) On time (ms) On+off time (ms) Duty cycle (%) Duty Factor (dB) 1/T Minimun VBW (kHz) Page 1 of 3 Report Number: 2302FR11 Version: 00 Power Limit Peak Gain EIRP Power Limit dBmWdBmdBidBmWW BLE 1M240218.610.072630.002.4021.010.12624.00200.00 BLE 1M244018.320.067930.002.4020.720.11804.00200.00 BLE 1M248017.970.062730.002.4020.370.10894.00200.00 Note: The relevant measured result has the offset with cable loss already. Average Power EIRP Power Maximum Conducted Output Power Measurement Test Mode Frequency (MHz) Test Software Version RF Power setting in Test Software ADB CMD Page 2 of 3 Report Number: 2302FR11 Version: 00 Frequency99 % Occupied Bandwidth6 dB Bandwidth 6 dB Limit (MHz)(MHz)(kHz)(kHz) BLE 1M24021.031645.8000≧ 500 BLE 1M24401.034644.8000≧ 500 BLE 1M24801.036644.3000≧ 500 FrequencyLimit (MHz)(dBm/3 kHz) BLE 1M2402≦ 8 BLE 1M2440≦ 8 BLE 1M2480≦ 8 3.660 6 dB Bandwidth and 99 % Occupied Bandwidth Test mode Maximum Power Density Measurement Reading (dBm/3 kHz) 4.150 3.740 Test mode Page 3 of 3 Report Number: 2302FR11 Version: 00
Appendix B. Test Plots Duty cycle BLE 1M On+off time Page 1 of 7 Report Number: 2302FR11 Version: 00 Out of Band Conducted Spurious Emission BLE 1M Low ch Mid ch High ch Page 2 of 7 Report Number: 2302FR11 Version: 00 Reference level BLE 1M Low ch Mid ch High ch Page 3 of 7 Report Number: 2302FR11 Version: 00 Conducted Band Edge BLE 1M Low ch High ch Page 4 of 7 Report Number: 2302FR11 Version: 00 6 dB Bandwidth BLE 1M Low ch Mid ch High ch Page 5 of 7 Report Number: 2302FR11 Version: 00 99 % Occupied Bandwidth BLE 1M Low ch Mid ch High ch Page 6 of 7 Report Number: 2302FR11 Version: 00 Power Density BLE 1M Low ch Mid ch High ch Page 7 of 7 Report Number: 2302FR11 Version: 00
Page 1 of 42 Report Number: 2302FR11 Version: 00 RF Test Report Applicant : Plume Design, Inc. Product Name : SuperPod Aon Trade Name : Plume Design, Inc. Model Number : G2A Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Received Date : Nov. 23, 2022 Test Period : Dec. 14, 2022 ~ Jan. 09, 2023 Issued Date : Apr. 21, 2023 Issued by Eurofins E&E Wireless Taiwan Co., Ltd. No. 140-1, Changan Street, Bade District, Taoyuan City 334025, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Frequency Range: 9 kHz to 325 GHz (Bade test site) Frequency Range: 9 kHz to 40 GHz (Wugu test site) Test Firm MRA designation number: TW0010 Note: 1.The test results are valid only for samples provided by customers and under the test conditions described in this report. 2.This report shall not be reproduced except in full, without the written approval of Eurofins E&E Wireless Taiwan Co., Ltd. 3.The relevant information is provided by customers in this test report. According to the correctness, appropriateness or completeness of the information provided by the customer, if there is any doubt or error in the information which affects the validity of the test results, the laboratory does not take the responsibility. Page 2 of 42 Report Number: 2302FR11 Version: 00 Revision History Version Issued Date Revisions Revised By 00 Apr. 21, 2023 Initial Issue Rowan Hsieh Page 3 of 42 Report Number: 2302FR11 Version: 00 Ve r i f i c a t i o n o f C o m p l i a n c e Applicant : Plume Design, Inc. Product Name : SuperPod Aon Trade Name : Plume Design, Inc. Model Number : G2A FCC ID : 2AG7G-G2A Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Test Result : Complied Performing Lab. : Eurofins E&E Wireless Taiwan Co., Ltd. No. 140-1, Changan Street, Bade District, Taoyuan City 334025, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Eurofins E&E Wireless Taiwan Co., Ltd. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by Eurofins E&E Wireless Taiwan Co., Ltd. based on interpretations and/or observations of test results. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Approved By : Page 4 of 42 Report Number: 2302FR11 Version: 00 TABLE OF CONTENTS 1 General Information ......................................................................................................... 5 1.1. Summary of Test Result ............................................................................................. 5 1.2. Testing Location ......................................................................................................... 6 1.3. Measurement Uncertainty .......................................................................................... 6 2 EUT Description................................................................................................................ 7 3 Test Methodology ............................................................................................................. 8 3.1. Mode of Operation ..............…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15C | 2.41 GHz - 2.46 GHz | 831.00 mW |
SuperPod with Wifi, Matter and Bluetooth
Equipment Class
NII - Unlicensed National Information Infrastructure TX
SuperPod with WiFi 6E
Equipment Class
DTS - Digital Transmission System
Plume Adaptive WiFi
Equipment Class
DTS - Digital Transmission System
Plume Adaptive WiFi
Equipment Class
NII - Unlicensed National Information Infrastructure TX