FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HANGZHOU HILAND TECHNOLOGY CO.,LTD/
  3. 2AGCVR51XX2015

2AGCVR51XX2015Receiver

HANGZHOU HILAND TECHNOLOGY CO.,LTD

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Nov 11, 2015
Application Purpose
Original Equipment
Date of Application
Nov 11, 2015
Equipment Note
Receiver
Frequency Range
433.92000000 - 433.92000000
Company
HANGZHOU HILAND TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—
โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Caution. ยง 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ยง 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ยง 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.

External Photos

Test Report No. 15021064-FCC-E Page 17 of 28 Annex B. EUT And Test Setup Photographs Annex B.i. Photograph EUT External Photo Top View of EUT Bottom View of EUT Test Report No. 15021064-FCC-E Page 18 of 28 Top View of EUT Bottom View of EUT Test Report No. 15021064-FCC-E Page 19 of 28 Left View of EUT Right View of EUT

ID Label/Location Info

Label Location

Internal Photos

Test Report No. 15021064-FCC-E Page 20 of 28 Annex B.ii. Photograph EUT Internal Photo Uncover- Front View EUT PCBA โ€“ Front View Test Report No. 15021064-FCC-E Page 21 of 28 EUT PCBA โ€“ Rear View Antenna

Test Report

EMC TEST REPORT Report No.: 15021064-FCC-E Supersede Report No.: N/A Applicant HANGZHOU HILAND TECHNOLOGY CO.,LTD Product Name Receiver Main Model R5113 Serial Model R51XX (XX=00-99) Test Standard FCC Part 15 Subpart B:2015, ANSI C63.4:2014 Test Date November 03, 2015 Issue Date November 05, 2015 Test Result Pass Fail Equipment complied with the specification Equipment did not comply with the specification Deon Dai Test Engineer Herve Idoko Checked By This test report may be reproduced in full only Test result presented in this test report is applicable to the tested sample only Issued by: SIEMIC (Nanjing-China) Laboratories 2-1 Longcang Avenue Yuhua Economic and Technology Development Park, Nanjing, China Tel:+86(25)86730138 Fax:+86(25)86730127 Email: [email protected] Test Report No. 15021064-FCC-E Page 2 of 28 Laboratories Introduction SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications. In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the fastest, most cost effective way to attain regulatory compliance for the global markets. Accreditations for Conformity Assessment Country/Region Scope USA EMC, RF/Wireless, SAR, Telecom Canada EMC, RF/Wireless, SAR, Telecom Taiwan EMC, RF, Telecom, SAR, Safety Hong Kong RF/Wireless, SAR, Telecom Australia EMC, RF, Telecom, SAR, Safety Korea EMI, EMS, RF, SAR, Telecom, Safety Japan EMI, RF/Wireless, SAR, Telecom Singapore EMC, RF, SAR, Telecom Europe EMC, RF, SAR, Telecom, Safety Test Report No. 15021064-FCC-E Page 3 of 28 This page has been left blank intentionally. Test Report No. 15021064-FCC-E Page 4 of 28 CONTENTS 1. REPORT REVISION HISTORY ....................................................................................................................................... 5 2. CUSTOMER INFORMATION ......................................................................................................................................... 5 3. TEST SITE INFORMATION ............................................................................................................................................ 5 4. EQUIPMENT UNDER TEST (EUT) INFORMATION ......................................................................................................... 6 5. TEST SUMMARY .......................................................................................................................................................... 7 6. MEASUREMENTS, EXAMINATION AND DERIVED RESULTS ........................................................................................ 8 6.1 AC POWER LINE CONDUCTED EMISSIONS ..................................................................................................................... 8 6.2 RADIATED EMISSIONS .................................................................................................................................................. 12 ANNEX A. TEST INSTRUMENT ............................................................................................................................................ 16 ANNEX B. EUT AND TEST SETUP PHOTOGRAPHS ........................................................................................................... 17 ANNEX C. TEST SETUP AND SUPPORTING EQUIPMENT ................................................................................................... 24 ANNEX D. USER MANUAL / BLOCK DIAGRAM / SCHEMATICS / PARTLIST ........................................................................ 27 ANNEX E. DECLARATION OF SIMILARITY ......................................................................................................................... 28 Test Report No. 15021064-FCC-E Page 5 of 28 1. Report Revision History Report No. Report Version Description Issue Date 15021064-FCC-E NONE Original November 05, 2015 2. Customer information Applicant Name HANGZHOU HILAND TECHNOLOGY CO.,LTD Applicant Add 4 TH BUILDING,2XIYUANWU ROAD,WESTLAKE TECHNOLOGY GARDEN,HANGZHOU,CHINA Manufacturer HANGZHOU HILAND TECHNOLOGY CO.,LTD Manufacturer Add 4 TH BUILDING,2XIYUANWU ROAD,WESTLAKE TECHNOLOGY GARDEN,HANGZHOU,CHINA 3. Test site information Lab performing tests SIEMIC (Nanjing-China) Laboratories Lab Add 2-1 Longcang Avenue Yuhua Economic and Technology Development Park, Nanjing, China FCC Test Site No. 986914 IC Test Site No. 4842B-1 Test Software Labview of SIEMIC version 1.0 Test Report No. 15021064-FCC-E Page 6 of 28 4. Equipment under Test (EUT) Information Description of EUT: Receiver Main Model: R5113 Serial Model: R51XX (XX=00-99) Date EUT received: October 28, 2015 Test Date(s): November 03, 2015 Operating Frequency : 433.92MHz(Rx) Antenna Gain 0 dBi Type of Modulation: ASK Number of Channels: 1 CH Input Power 12-24VAC/DC Trade Name : HILAND FCC ID: 2AGCVR51XX2015 Test Report No. 15021064-FCC-E Page 7 of 28 5. Test Summary The product was tested in accordance with the following specifications. All testing has been performed according to below product classification: FCC Rules Description of Test Result ยง15.207; ANSI C63.4: 2014 AC Power Line Conducted Emissions Compliance ยง15.209; ANSI C63.4: 2014 Radiated Emissions Compliance Measurement Uncertainty Emissions Test Item Description Uncertainty Radiated Emissions Confidence level of approximately 95% (in the case where distributions are normal), with a coverage factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m) 3.952dB Test Report No. 15021064-FCC-E Page 8 of 28 6. Measurements, Examination And Derived Results 6.1 AC Power Line Conducted Emissions Temperature 24 o C Relative Humidity 50% Atmospheric Pressure 1019mbaโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test Report No. 15021064-FCC-E Page 22 of 28 Annex B.iii. Photograph Test Setup Photo Conducted Emissions Setup Front View Conducted Emissions Setup Side View Test Report No. 15021064-FCC-E Page 23 of 28 Radiated Emissions Setup Below 1GHz Front View

Contact Information

Applicant

bosheng Yin(General manager)
[email protected]0571-81958387Fax: 0571-81958133

Test Firm

SIEMIC (Nanjing-China) LaboratoriesLeslie Bai
[email protected]86-25-86730128Fax: 86-25-86730127

Technical Specifications

#Rule PartsFrequency RangePower Output
115B433.92 MHz - 433.92 MHz-