2AGCZ-BIOCONVBioCon-V Probe

Mcube Technology Co.,Ltd
BioCon-V Probe - FCC ID 2AGCZ-BIOCONV - Mcube Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
May 18, 2026
Application Purpose
Original Equipment
Equipment Note
BioCon-V Probe
Frequency Range
5745.00000000 - 5825.00000000
Company
Mcube Technology Co.,Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operator’s Manual This page is empty CUBEScan TM BioCon-V Operator’s Manual BioCon-V Bladder Volume Measurement System Operator’s Manual This product is a medical device. Please read the precautions and instructions carefully before use. Please note that the information in this manual is subject to change without prior notice. No part of this manual may be reproduced in any form or by any means, electronic or mechanical, without the permission of Mcube Technology Co., Ltd. This manual may not be reproduced or translated into other formats, including digital or printed media. The figures and examples in this document are not based on actual patient data. For the latest user information, please contact your sales representative or Mcube Technology Co., Ltd. The appearance, specifications, features, application screens, and image content of the product in this guide are subject to change without prior notice to improve the product’s performance. Mcube Technology Co., Ltd. 39 Magokjungang 12-ro, Gangseo-gu, Seoul 07789, Republic of Korea Tel: +82 02-3421-7780 Fax: +82 02-3421-7076 Email: [email protected] Website: www.mcubetech.co.kr Copyright ⓒ2026 by Mcube Technology Co., Ltd. All rights reserved. CUBEScan TM BioCon-V Operator’s Manual CONTENTS 1. GENERAL INFORMATION ........................................................................................ 1 1.1. PRODUCT DESCRIPTION .............................................................................................................. 1 1.2. INTENDED PURPOSE .................................................................................................................... 1 1.3. PATIENT/USER CHARACTERISTICS .............................................................................................. 1 1.4. UNDESIRABLE SIDE EFFECTS ....................................................................................................... 2 1.5. SERVICES ........................................................................................................................................ 2 1.6. INCIDENT REPORTING (VIGILANCE SYSTEM) ........................................................................... 2 2. SAFETY INFORMATION ............................................................................................ 3 2.1. NOTICE TO ALL USERS ................................................................................................................. 3 2.2. CONTRAINDICATIONS .................................................................................................................. 3 2.3. ELECTRICAL SAFETY ...................................................................................................................... 3 2.4. BATTERY SAFETY ........................................................................................................................... 6 2.5. DEVICE SAFETY.............................................................................................................................. 8 2.6. SAFE HANDLING PROCEDURES FOR TRANSPORT ................................................................... 9 3.1. PRODUCT FEATURES .................................................................................................................. 10 3.2. SYSTEM COMPONENTS.............................................................................................................. 10 3.3. OUTER APPEARANCE – PROBE ................................................................................................. 11 3.4. OUTER APPEARANCE – CHARGING CRADLE ........................................................................... 12 3.5. INFORMATION SCREEN DISPLAY .............................................................................................. 13 4. PREPARATION BEFORE USE ................................................................................... 14 4.1. CHARGING CRADLE INSTALLATION .......................................................................................... 14 4.2. BATTERY CHARGING .................................................................................................................. 14 5. HOW TO USE .......................................................................................................... 17 5.1. MEASUREMENT ACCURACY ...................................................................................................... 17 5.2. CHECK BEFORE USE .................................................................................................................... 17 5.3. TURN THE DEVICE ON/OFF ....................................................................................................... 18 5.4. BUTTON OPERATIONS GUIDE ................................................................................................... 18 5.5. INITIAL SETUP ............................................................................................................................. 19 5.6. HOME SCREEN ............................................................................................................................ 21 5.7. SCAN PREPARATION .................................................................................................................. 22 5.8. LOCATING THE BLADDER (PRE-SCAN) ..................................................................................... 23 5.9. CHECK SCAN RESULTS ............................................................................................................... 26 5.10. LAST SCAN RESULT .................................................................................................................... 27 5.11. PASSWORD RESET PROCEDURE ................................................................................................ 29 5.12. AUTO SLEEP MODE ..................................................................................................................... 32 CUBEScan TM BioCon-V Operator’s M…

Text truncated - open the document above for the full version.

Attestation Statements

Mcube Technology Co.,Ltd. 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea Tel: +82.2.3421.7780 Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 17, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID : 2AGCZ-BIOCONV [Mcube Technology Co.,Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Mcube Technology Co.,Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, ChangHyun Kim/QMR Mcube Technology Co.,Ltd. Mcube Technology Co.,Ltd. 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea Tel: +82.2.3421.7780 Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 17, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID : 2AGCZ-BIOCONV [Mcube Technology Co.,Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, ChangHyun Kim/QMR Mcube Technology Co.,Ltd.

Attestation Statements

Certification designating a U.S. Agent for service of process: As required by section 2.911(d)(7), the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. In either scenario, the designation of the U.S. agent for service of process should be provided as an attachment to the equipment authorization application. The applicant must provide a written certification, which must: i. Be signed by both the applicant and designated agent for service of process, if the agent is different from the applicant. ii. Acknowledge the applicant’s consent and the designated agent’s obligation to accept service of process. iii. Provide a physical U.S. address and email for the designated agent. iv. Acknowledge the applicant’s acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Unofficial information provided by FCC personnel on February 14, 2023, via the monthly call with the TCB Council: The Agent for Process of Service: • cannot be a TCB or affiliated with a TCB (e.g. could not be a person who works for a TCB or a company that owns or is owned by the TCB) • cannot be a [FCC recognised] Lab or affiliated with a test lab (e.g. could not be a person who works for a Lab or a company that owns or is owned by the Lab) • Agent can be Individual Entity or a Company Entity • Agent Entity must be located in US, US address/phone • Entity acting as Agent must have FRN (best practice, put FRN on Agent Letter) • Agent letter does not have to be FCC ID specific, can be general Agent for Grantee For devices being marketed or for which marketing has ceased for less than 1 year, if the Agent for Process of Service changes, then for every TC Number the TCB must request the FCC to put application into Audit Mode and Agent Letter needs to be updated (superseded). NOTE: The U.S. Agent for Service of Process should not be confused with the authorized agent used for signing the 731 form, other cover letters within the application, and/or the agent who may interface with the TCB. Mcube Technology Co., Ltd. 39, Magokjungang 12-ro, Ganseo-gu, Seoul, 07789, Republic of Korea U.S. Agent Designation for Service of Process ATTENTION: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA REGARDING: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Approve-IT, Inc. Contact Name: Nathan Grinager Street Address: 8011 34 th Ave South, Suite 342 City/Province/Zip: Bloomington, MN 55425 Telephone No: 651-247-1678 Email: [email protected] FRN #: 0027533835 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: April 15, 2026 Signed by (Printed Name/Title): Nathan Grinager / Co-President The Applicant confirms its explicit consent and acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Mcube Technology Co., Ltd. Grantee FRN: 0025009408 FCC ID: 2AGCZ-BIOCONV Contact Name: Chang Hyun, Kim Street Address: 39, Magokjungang 12-ro, Ganseo-gu, City/Province/Zip: Seoul, 07789, Republic of Korea Telephone No: +82.2.3421.7780 Email: [email protected] Applicant Signature: Date: 2026-04-13 Signed by (Printed Name/Title): Chang Hyun, Kim / Manager

Attestation Statements

R F Function Attestation Statement Company Name Mcube Technology Co., Ltd. Model Name BioCon-V FCC ID 2AGCZ-BIOCONV IC Number 20981-BIOCONV The R F module used in this device supports multiple transmitter functions. However, for this specific product configuration, only the UNII (WiFi) transmitter function is enabled and utilized. All other RF functions supported by the module, including but not limited to Bluetooth and 2.4GHz WLAN, are permanently disabled. These functions are not accessible to the end user under any condition. The disabling of unused RF functions is implemented via firmware configuration. These functions cannot be activated during normal operation, nor through any user-accessible interface. Additionally, no simultaneous transmission with other RF functions is possible. Furthermore, wireless transmission is disabled during the charging state. The device does not perform any RF transmission while being charged. Name ChangHyun Kim Title QMR Date / Signature 2026/04/30

Cover Letter(s)

Mcube Technology Co.,Ltd. 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea Tel: +82.2.3421.7780 Date: April 17, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Confidentiality Request regarding application for certification of FCC ID : 2AGCZ-BIOCONV Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules and IC regulation, we hereby request confidential treatment of information accompanying this application as outlined below: PERMANENT Exhibit Type File Name Part List Part List.pdf Schematics Diagram(s) Schematic.pdf Operation description Operation description.pdf Block diagram Block diagram.pdf And the above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, ChangHyun Kim/QMR Mcube Technology Co.,Ltd.

Cover Letter(s)

AD1608-A2455AAT/LF REV:6 PAGE: 1 / 15 S-R00-N881 ACX Advanced Ceramic X Features  Monolithic SMD with small, low-profile and light-weight type.  Wide bandwidth  RoHS compliant Applications Dual-band 2.4/5.5 GHz WLAN Specifications Part Number Frequency Range (MHz) Peak Gain (dBi typ.) Average Gain (dBi typ.) VSWR Impedance AD1608 -A2455AA_ 2400~2480 1.0(XZ-Total)-3.5(XZ-Total)6.5 max. 50  5150~5850 4.0(XZ-Total)-2.5(XZ-Total)4.5 max. 50  Q’ty/Reel (pcs) : 4,000 pcs Operating Temperature Range : -40 ~ +85 o C Storage Temperature Range : -40 ~ +85 o C Storage Period : 12 months max. Power Capacity : 3W max. Part Number  Type AD : Dual-band Antenna  Dimensions ( L × W ) 1.6× 0.8 mm  Material Code A  Frequency Range 2455=2400/5500 MHz  Specification Code AA  Packaging T: Tape & Reel B: Bulk  Soldering /LF=lead-free Terminal Configuration No. Scenario#1 Terminal Name No. Scenario#2 Terminal Name  GND  GND  Feed  NC  NC  NC  NC  Feed     AD1608 Series Multilayer Chip Antenna AD 1608 - A 2455 AA        AD1608-A2455AAT/LF REV:6 PAGE: 2 / 15 S-R00-N881 ACX Advanced Ceramic X Dimensions Typical Electrical Characteristics (T=25 o C) Test Board –Type A (Scenario#1) *Line width should be designed to match 50 characteristic impedance, depending on PCB material and thickness. Mark L W T a b c d e f g h Dimensions 1.6 0.1 0.8 0.1 0.4 max 0.086 0.1 0.208 min 0.2 0.03 0.085 +0.03 -0.075 0.215 0.07 0.25 0.05 -0.10 0.15 min 0.2 0.03 -0.05 Ground 65 5 120 50Feed Line 8 Matching circuit T e L f a W d c b g h Top View Bottom View Side View Unit: mm AD1608-A2455AAT/LF REV:6 PAGE: 3 / 15 S-R00-N881 ACX Advanced Ceramic X Antenna Footprint with matching _top view (Unit in mm) Antenna Footprint with matching _bottom view (Unit in mm) 0.25 1.0nH 5.8 3 0.65 4.1 0.14 5.66 2.2 0.25 0.65 4.1 Matchin g circuits 0.35 0.21 0.3 0.15 0.15 0.5 0.6 0.45 0.4 1.1 0.15 1.43 0.6 3.0 0.15 AD1608-A2455AAT/LF REV:6 PAGE: 4 / 15 S-R00-N881 ACX Advanced Ceramic X 2.53.03.54.04.55.05.52.06.0 -20 -15 -10 -5 -25 0 freq, GHz dB(S(1,1)) m129 m130 m131 m132 m133 m134 m129 freq= dB(S(1,1))=-14.010 2.442GHz m130 freq= dB(S(1,1))=-6.202 2.400GHz m131 freq= dB(S(1,1))=-9.880 2.484GHz m132 freq= dB(S(1,1))=-12.066 5.150GHz m133 freq= dB(S(1,1))=-24.657 5.500GHz m134 freq= dB(S(1,1))=-10.323 5.850GHz freq (2.000GHz to 6.000GHz) S(1,1) m128 m135 m128 freq= S(1,1)=0.199 / 110.889 impedance = 40.626 + j15.755 2.442GHz m135 freq= S(1,1)=0.059 / 59.150 impedance = 52.817 + j5.324 5.500GHz Return Loss (with matching) AD1608-A2455AAT/LF REV:6 PAGE: 5 / 15 S-R00-N881 ACX Advanced Ceramic X Radiation [email protected] (Antenna Efficiency 42%@ 2.4GHz ; 60%@2.44GHz ; 56%@2.48GHz) Y :Φ(Phi)=90 o X :Φ(Phi)=0 o Z : θ(Theta)=0 o XY-plane @2440MHz Total YZ-plane @2440MHz Total XZ-plane @2440MHz Total AD1608-A2455AAT/LF REV:6 PAGE: 6 / 15 S-R00-N881 ACX Advanced Ceramic X Radiation [email protected] (Antenna Efficiency 78%@ 5.15GHz ; 86%@5.5GHz ; 76%@5.85GHz) Y :Φ(Phi)=90 o X :Φ(Phi)=0 o Z : θ(Theta)=0 o XY-plane @5500MHz Total YZ-plane @5500MHz Total XZ-plane @5500MHz Total AD1608-A2455AAT/LF REV:6 PAGE: 7 / 15 S-R00-N881 ACX Advanced Ceramic X Test Board-Type B (Scenario#1) *Line width should be designed to match 50 characteristic impedance, depending on PCB material and thickness. Antenna Footprint with matching _ top view (Unit in mm) 70 Matching circuits 0.25 1.0nH 3 0.65 4.1 Ground 40 5 50Feed Line 8 Matching circuit 5.8 0.35 0.21 0.3 0.15 0.15 0.5 0.6 0.45 0.4 1.1 0.15 1.43 0.6 3.5 0.15 AD1608-A2455AAT/LF REV:6 PAGE: 8 / 15 S-R00-N881 ACX Advanced Ceramic X 2.53.03.54.04.55.05.52.06.0 -20 -15 -10 -5 -25 0 freq, GHz dB(S(1,1)) m129 m130 m131 m132 m133 m134 m129 freq= dB(S(1,1))=-18.254 2.442GHz m130 freq= dB(S(1,1))=-7.250 2.400GHz m131 freq= dB(S(1,1))=-8.854 2.484GHz m132 freq= dB(S(1,1))=-9.557 5.150GHz m133 freq= dB(S(1,1))=-20.673 5.500GHz m134 freq= dB(S(1,1))=-10.013 5.850GHz freq (2.000GHz to 6.000GHz) S(1,1) m128 m135 m128 freq= S(1,1)=0.122 / 95.014 impedance = 47.527 + j11.753 2.442GHz m135 freq= S(1,1)=0.093 / 81.368 impedance = 50.543 + j9.329 5.500GHz Antenna Footprint with matching _ bottom view (Unit in mm) Return Loss (with matching) 0.14 5.66 2.2 0.25 0.65 4.1 AD1608-A2455AAT/LF REV:6 PAGE: 9 / 15 S-R00-N881 ACX Advanced Ceramic X Radiation [email protected] (Antenna Efficiency 48%@ 2.4GHz ; 66%@2.44GHz ; 60%@2.48GHz) Y :Φ(Phi)=90 o X :Φ(Phi)=0 o Z : θ(Theta)=0 o XY-plane @2440MHz Total YZ-plane @2440MHz Total XZ-plane @2440MHz Total AD1608-A2455AAT/LF REV:6 PAGE: 10 / 15 S-R00-N881 ACX Advanced Ceramic X Radiation [email protected] (Antenna Efficiency 70%@ 5.15GHz ; 79%@5.5GHz ; 67%@5.85GHz) Y :Φ(Phi)=90 o X :Φ(Phi)=0 o Z : θ(Theta)=0 o XY-plane @5500MHz Total YZ-plane @5500MHz Total XZ-plane @5500MHz Total AD1608-A2455AAT/LF REV:6 PAGE: 11 / 15 S-R00-N881 ACX Advanced Ceramic X Application note of Scenario#2 Test Board –Type A (Scenario#2) *Line width should be designed to match 50 characteristic impedance, depending on PCB material and thickness. Antenna Footprint with matching _top view (Unit in mm) Ground 5 120 50Feed Line 8 0.25 0.65 4.1 3.0 65 0.35 0.21 0.3 0.15 0.15 0.5 0.6 0.45 0.15 0.6 3.0 0.15 0.4 1.1 1.43 AD1608-A2455AAT/LF REV:6 PAGE: 12 / 15 S-R00-N881 ACX Advanced Ceramic X Taping Specifications Tape Dimensions (Unit: mm) & Quantity Reel Dimensions (Unit: mm) Leader and Trailer Tape Type A A’ B C D E F T Quantity/reelTape material 1608 4.0± 0.1 4.0± 0.1 0.95± 0.1 1.80± 0.1 2.0± 0.1 3.5± 0.1 8.0± 0.1 0.60± 0.03 4,000pcs Paper Type A B 1608 2.3±0.5 9.0±0.3 A’ D F E 1.75 ± 0.1 AB T PA P E R TA P E C 60±1 178± 1 13.5±0.5 A Label Label: Customer’s Name, ACX P/N, Q’ty, Date, ACX Corp. 1.4 ± 0.2 B Trailer End Trailer (160 mm min.) Empty Compartments with Cover Tape (500 mm min.) AD1608-A2455AAT/LF REV:6 PAGE: 13 / 15 S-R00-N881 ACX Advanced Ceramic X Peel-off Force Peel-off force should be in the range of 0.1 – 0.6 N at a peel-off speed of 300±10 mm/min . Storage Condit…

Text truncated - open the document above for the full version.

Cover Letter(s)

Mcube Technology Co.,Ltd. 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea Tel: +82.2.3421.7780 Date: April 17, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 FCC ID: 2AGCZ-BIOCONV To whom it may concern: I, the undersigned, hereby authorize Young-Jin, Lee of KES Co., Ltd. and hereafter referred to as KES Co., Ltd., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Young-Jin, Lee of KES Co., Ltd. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing KES Co., Ltd. as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; Mcube Technology Co.,Ltd. 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea Tel: +82.2.3421.7780 h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, ChangHyun Kim/QMR Mcube Technology Co.,Ltd. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database.

External Photos

FCC ID : 2AGCZ-BIOCONV Page : 1 of 4 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsandan 1- ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 External photos of eut T op view of eut Bo ttom view of eut FCC ID : 2AGCZ-BIOCONV Page : 2 of 4 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsandan 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 Front view of eut Rear view of eut FCC ID : 2AGCZ-BIOCONV Page : 3 of 4 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsandan 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 Left side of eut Right side of eut FCC ID : 2AGCZ-BIOCONV Page : 4 of 4 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsandan 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 Product Configuration

ID Label/Location Info

1) BioCon-V (PROBE) Label Sample Label Location (Back) The label attachment using permanent adhesive. The label will neither peel off nor fade during the expected lifespan Screw

Internal Photos

FCC ID : 2AGCZ-BIOCONV Page : 1 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 1.INTERNAL PHOTOS 1) INTERNAL PHOTOS_1 2) INTERNAL PHOTOS_2 FCC ID : 2AGCZ-BIOCONV Page : 2 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 3) COIL FRONT 4) COIL REAR FCC ID : 2AGCZ-BIOCONV Page : 3 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 5) SUB BOARD FRONT_1 6) SUB BOARD REAR_1 FCC ID : 2AGCZ-BIOCONV Page : 4 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 7) BATTERY FRONT 8) BATTERY REAR FCC ID : 2AGCZ-BIOCONV Page : 5 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 9) INTERNAL PHOTOS_3 10) DISPLAY_1 FCC ID : 2AGCZ-BIOCONV Page : 6 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 11) DISPLAY_2 12) DISPLAY_3 FCC ID : 2AGCZ-BIOCONV Page : 7 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 13) DISPLAY_4 14) DISPLAY_5 FCC ID : 2AGCZ-BIOCONV Page : 8 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 15) MAINBOARD FRONT_1 16) MAINBOARD FRONT_2 FCC ID : 2AGCZ-BIOCONV Page : 9 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 17) MAINBOARD REAR FCC ID : 2AGCZ-BIOCONV Page : 10 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 18) RF MODULE_1 19) RF MODULE_2 FCC ID : 2AGCZ-BIOCONV Page : 11 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 20) ANTENNA FCC ID : 2AGCZ-BIOCONV Page : 12 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 21) SUB BOARD FRONT_2 22) SUB BOARD REAR_2 FCC ID : 2AGCZ-BIOCONV Page : 13 of 13 IC : 20981-BIOCONV UL Korea, Ltd. Uiwang Laboratory 42 Obongsanda 1-ro, Uiwang-si, Gyeonggi-do Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 23) INTERNAL PHOTOS_4 24) INTERNAL PHOTOS_5

RF Exposure Info

TEST REPORT Report No. : KES-SR250214-R1 Page 1 / 65 KES Co., Ltd. #3002, #3503, #3701, 40, Simin-daero365beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Republic of Korea Tel : +82-31-425-6200, Fax : +82-31-341-3838 KES-QP16-F01(00-23-01-01) KES Co., Ltd. You can check the authenticity of this test report on the authenticity verification page on our website (www.kes.co.kr). 1. Client ○ Name : Mcube Technology Co.,Ltd. ○ Address : 39, Magokjungang 12-ro, Gangseo-gu, Seoul, 07789, Republic of Korea 2. Sample Description ○ Product item : Bladder Volume Measurement System ○ FCC ID : 2AGCZ-BIOCONV ○ Model name : BioCon-V Probe ○ Multiple Model Name : N/A ○ Manufacturer etc. : Mcube Technology Co.,Ltd. 3. Date of test : 2026.03.04 4. Location of Test :  Permanent Testing Lab  On Site Testing ○ Address : #3002, #3503, #3701, 40, Simin-daero365beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14057, Republic of Korea 5. Test method used : CFR §2.1093 6. Test result : PASS The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced and copied without permission without the written consent of KES Co., Ltd. This laboratory is not accredited for the test results marked *. This test report is not related to KOLAS accreditation. Affirmation Tested by Technical Manager Name : Min-sup, Kim (Signature) Name : Du-Hee, Lee (Signature) 2026 . 05. 08. KES Co., Ltd. Report No. : KES-SR250214-R1 Page 2 / 65 KES-QP16-F01(00-23-01-01) KES Co., Ltd. You can check the authenticity of this test report on the authenticity verification page on our website (www.kes.co.kr). REPORT REVISION HISTORY Date Test Report No. Revision History 2026.04.28 KES-SR250214 Initial 2026.05.08 KES-SR250214-R1 Modification of the model name This report shall not be reproduced except in full, without the written approval of KES Co., Ltd. This document may be altered or revised by KES Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by KES Co., Ltd. will constitute fraud and shall nullify the document. Report No. : KES-SR250214-R1 Page 3 / 65 KES-QP16-F01(00-23-01-01) KES Co., Ltd. You can check the authenticity of this test report on the authenticity verification page on our website (www.kes.co.kr). TABLE OF CONTENTS 1. General Information ........................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Changhyun Kim(QMR)
[email protected]Fax: +82-(0)2-3421-7076

Technical Contact

Approve-IT, Inc.Nathan Grinager
[email protected]

8011 34th Ave South · Bloomington, Minnesota, 55425 · United States

Test Firm

UL Korea, Ltd.Junwhan Lee
[email protected]Fax: +82-31-213-5433

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.75 GHz - 5.83 GHz6.92 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum combined conducted output power. The highest reported SAR for body-worn is 0.33 W/kg. This device supports 20, 40 and 80 MHz bandwidth modes.