FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Empatica Srl/
  3. 2AGGH-MINI

2AGGH-MINIEmbraceMini

Empatica Srl
EmbraceMini - FCC ID 2AGGH-MINI - Empatica Srl
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 21, 2026
Application Purpose
Original Equipment
Equipment Note
EmbraceMini
Frequency Range
2402.00000000 - 2480.00000000
Company
Empatica Srl
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM--0003108 | REV 1.0, JULY 2025 EmbraceMini EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 1 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 1 What is EmbraceMini? EmbraceMini is a medical device designed to track and transmit key health data to a companion app/system, enabling continuous analysis and extraction of precise Digital Biomarkers. EmbraceMini can seamlessly capture important physiological parameters from its powerful sensors, including accelerometer, gyroscope, magnetometer, and ambient light sensor. From these sensors, the following health metrics can be collected: physical activity, sleep patterns, and light exposure. For a complete list of monitored parameters, please contact your study administrator. Your study may require you to use one or more EmbraceMini devices in different positions, either alone or in combination with other devices. If you have any questions, please reach out to your study administrator. EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 2 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 2 1.Device Serial Number 2.LED Indicator Light 3.Mechanical Button 4.Stainless Steel Housing EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 3 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 3 Get started with your EmbraceMini EmbraceMini works with a companion app/system. Please be sure to have the app/system and related instructions in hand to start. WAKE UP AND PAIR EMBRACEMINI WAKE UP THE DEVICE Turn on EmbraceMini by pressing the button. The white LED will turn on softly, and after 5 seconds, the blinking blue LED will signal that EmbraceMini is ready to be paired. If EmbraceMini does not immediately wake up, we recommend placing it in the charger in case the battery is drained PAIR VIA BLUETOOTH To complete the pairing process, you'll need to press the button on your EmbraceMini to send a pairing request. The blue LED will start blinking faster. Then follow the instructions in the app. Only confirm pairing with devices you recognize. EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 4 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 4 How to wear your EmbraceMini To properly wear EmbraceMini, please follow the instructions in the Help Center in the Care App or in the app used in your study. Contact your study team for detailed instructions. Make sure to wear EmbraceMini correctly. Wearing EmbraceMini incorrectly will affect the quality of the data collected. Please always follow the wearing instructions given by the study team. EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 5 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 5 Standard Band at the Wrist 1. Wear it on your non-dominant hand, at 1-finger distance from your wrist bone (unless otherwise instructed) 2. Fasten the band and secure EmbraceMini until you feel some pressure EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 6 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 6 EmbraceMini Daily Use and Error Statuses EmbraceMini is designed to collect physiological data while seamlessly integrating into the participant's daily life. It connects via Bluetooth to the companion application/system to transfer data. Data will not be lost if disconnected from the smartphone for a few hours (depending on the sensor mode). EmbraceMini may be attached to the wrist, clothing, or other designated body areas, depending on the form factor it comes with. The device may be worn with a standard band or belt clip, allowing flexibility based on user preference and study requirements. Ensuring a secure and comfortable fit is essential for accurate data collection, as improper positioning may impact data collection. Users should follow study guidelines and the information in the Care App to determine the appropriate attachment method and placement for their specific setup. EmbraceMini User Manual _ Regulatory Document Number: UM--0003108 Document Version: 0.4 Document State: Draft CONFIDENTIAL Draft Page 7 of 39 Downloaded by Alberto Poli on 05 Sep, 2025 11:02:51 valid until 20 Oct, 2025 UNIVERSAL PATIENT INSTRUCTIONS FOR USE ENGLISH | UM-0003108 | REV 1.0, July 2025 7 CHARGING EMBRACEMINI To charge EmbraceMini, plug the USB-C cable into a standard 5V power source and place the device on the charger as shown. Be sure the pins click into place with the charging contacts on EmbraceMini. Status LEDDescriptionActions Charging in progress When the EmbraceMini is correctly placed on the charger, the LED turns white and starts blinking; this means that charging is in progress. Charging completeWhen fully charged, the LED turns off. Press the front button while on the charger; a white light means it's ready. Once removed, the LED turns on to show the current device status. EmbraceMini User Manual _ Regula…

Text truncated - open the document above for the full version.

Attestation Statements

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 Attestation Statements Not Covered Entity Applicant Date: 13 November 2025 Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2AGGH-MINI Empatica S.r.l. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Alberto Poli Title: Director, Quality & Regulatory Compliance Address: Empatica S.r.l. - Via Enrico Stendhal, 36 - 20144 Milan, Italy Tel.: +39 3356316498 Email: [email protected]

Attestation Statements

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 Attestation Statements Not Covered Equipment Date: 13 November 2025 Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2AGGH-MINI Empatica S.r.l. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Alberto Poli Title: Director, Quality & Regulatory Compliance Address: Empatica S.r.l. - Via Enrico Stendhal, 36 - 20144 Milan, Italy Tel.: +39 3356316498 Email: [email protected]

Attestation Statements

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 Certification Designating a US Agent for Service of Process Date: 02 December 2025 Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2AGGH-MINI Empatica S.r.l. (“the applicant”) certifies that as of the date of the filing of the application, Empatica Inc., (“the agent”) is our designated U.S. agent. We acknowledge the applicant’s consent and the designated agent for service of process’s obligation to accept service. The applicant accepts to maintain an agent for service of process for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. APPLICANT THE AGENT Company Name: Empatica S.r.l. Company Name: Empatica Inc. Contact Person: Alberto Poli Contact Person: Matteo Lai Address: Via Enrico Stendhal, 36 - 20144 Milan, Italy Address: 1 Broadway, 14 th Floor, Cambridge, 02142 (MA), USA Tel.: +393356316498 Tel.: (866) 739-2049 Email: [email protected] Email: [email protected] FCC FRN: 0025038498 FCC FRN (optional) Yours Sincerely, The Applicant The Agent Company Name Empatica S.r.l. Empatica Inc. Contact Person Alberto Poli Matteo Lai Signature

Cover Letter(s)

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 Date: 2025-11-13 Subject: Confidentiality Request for FCC ID: 2AGGH-MINI Pursuant to FCC 47 CRF 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Part List / Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual Empatica S.r.l. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: ____________________ Alberto Poli, Director, Quality & Regulatory Compliance Company: Empatica S.r.l.

Cover Letter(s)

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 Authority to Act as Agent Date: 02 December 2025 TÜV Rheinland of North America, Inc. 1279 Quarry Ln., Ste. A Pleasanton, CA 94566 To whom it may concern: I appoint TÜV Rheinland Italia S.r.l. and Mr. Riccardo Pfeiffer to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TÜV Rheinland Group, still resides with Empatica S.r.l. - Via Enrico Stendhal, 36 - 20144 Milan, Italy. If you have any questions regarding this, please don’t hesitate to contact us. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Agency Agreement Expiration Date: 6 months Yours Sincerely, Name: Alberto Poli Title: Director, Quality & Regulatory Compliance Company: Empatica S.r.l. - Via Enrico Stendhal, 36 - 20144 Milan, Italy

External Photos

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 EmbraceMini External Pictures

ID Label/Location Info

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 EmbraceMini FCC ID Placement Date: 20 January 2026 FCC ID: 2AGGH-MINI To whom it may concern: The present declaration is prepared to support the positioning of the FCC ID of our product EmbraceMini. Given the limited dimensions of the device, it is impractical to label it with the required FCC ID with a font of at least four points. As such, we report the required FCC ID on the device box, which is always provided to the user. Yours Sincerely, Name: Alberto Poli Title: Director, Quality & Regulatory Compliance Company: Empatica S.r.l. - Via Enrico Stendhal, 36 - 20144 Milan, Italy EmbraceMini - Information Supplied by the Manufacturer - Device Labeling, including translations, device labels, single unit packaging, sales packaging, and transport packaging EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 1 of 8 1. Introduction This document contains evidence and information related to Embracemini and box labeling and packaging. 2. EmbraceMini The device has specific labeling information directly printed (or engraved) and is packed within a box that is used to ship the product to Empatica’s customers. 2.1.Device Labeling On the back of the device, the following information is displayed: ● Product Name: EmbraceMini ● Manufacturer Name Empatica ● Device Serial Number: S/N 3YM1T141JT (provided as an example only) ● Precaution Symbol, Applied Parts type BF Symbol ● CE Mark ● Lot Number ● Manufacturing Date ● QR Code containing the FCC ID: 2AGGH-MINI Figure 1 - Drawing representing the front view of device with band detached 2.2.EmbraceMini Single-Unit Package Labeling EmbraceMini is packed within its shipping box at the end of the manufacturing process and after end-of-line tests are positively executed. This box contains the device and its charger. The front of the box contains the clear identification of the product name EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 2 of 8 On the back of the box, the required regulatory information is present. In particular: Figure 3 - Device box printed regulatory information EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 3 of 8 DescriptionSymbol/Image Marketing LOGO Images of the products contained in the box Consult Instruction for Use symbol, eIFU symbol and web- address Consult Instruction for Use symbol Storage Conditions Non-ionizing radiation symbol WEEE Symbol Applied Parts type BF symbol Caution Symbol CE Mark Symbol Medical Device Symbol IP Classification FCC Symbol and FCC ID Rx Only Symbol MR Unsafe EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 4 of 8 DescriptionSymbol/Image Manufacturer by symbol and manufacturer information Manufacturer website www.empatica.com Manufacturer email [email protected] Identification of country of manufacture PAP information (recycling information) Box and layout identification and revision An additional label is attached at the end of the manufacturing process on the side of the box. This label identifies each single device and contains the following information: DescriptionSymbol/Image SKU barcode identifies the product type variant and the quantity contained in the package Catalogue Number Lot number Date of manufacture Serial number EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 5 of 8 DescriptionSymbol/Image Unique Device Identifier (Human-Readable and Data Matrix) – identifies each single device An identification label is attached close to the USB end of the Cable Charger. This label contains the following information DescriptionSymbol/Image Catalogue Number Lot number Consult Instruction for Use symbol Manufacturer by symbol and manufacturer information Document History VersionDateReason for change 1.08 July 2025First issue of the document 2.024 July 2025Added IP classification symbol 3.08 August 2025Added cable charger label 4.09 October 2025Revised to reflect the revision of PKG-0002370 5.015 October 2025Update sleeve and device laser marking 6.022 October 2025 Specified embraceMINI as marketing LOGO Updated picture of the EmbraceMini POD 7.023 Oct 2025Updated to reflect the new version of the sleeve EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 6 of 8 EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 7 of 8 This is a representation of an electronic record that was signed electronically and this page is the manifestation of the electronic signatures. Signatory Table Action NameUser NameTitleSignature Date ApproveLaura TerminelliSr Design Quality Engineer23-Oct-2025 11:38 * Dates are displayed according to the system time zone: (GMT+02:00) Central European Summer Time (Europe/Rome) EmbraceMini - Labeling Information Document Number: APX-0003107 Document Version: 7.0 Effective Date: 23-Oct-2025 Document State: Effective (Simple) CONFIDENTIAL Page 8 of 8

Internal Photos

Property of Empatica. CONFIDENTIAL. Unauthorized distribution or copying prohibited. Page 1 of 1 EmbraceMini Internal Pictures Antenna

RF Exposure Info

TEST REPORT N. IT258LS3 001 Page 1 of 16 Issue Date: 01/12/2025 TEST REPORT 47 CFR § 2.1093 Radiofrequency radiation exposure evaluation: portable devices. Applicant: Empatica S.r.l. Via Stendhal 36 - 20144 Milano (MI – ITALY Test item: Wearable Actigraphy Identification / Type No.: EMBRACEMINI Order content: Radiofrequency radiation exposure evaluation according to the following standard(s): Test specification: 47 CFR § 2.1093 Date of receipt: 03/09/2025 Internal storage No.: A004083685-001 (sampled by the customer) Testing period: 02/10/2025 Place of testing: TÜV Rheinland Italia S.r.l. Via E. Mattei, 3 20005 Pogliano Milanese (MI) - IT Testing laboratory: TÜV Rheinland Italia S.r.l. Via E. Mattei,3 20005 Pogliano Milanese (MI) - IT Test result: Pass Tested by: Zaccaria Piazza Authorized by: Riccardo Pfeiffer Date: 01/12/2025 (Laboratory technician) Date: 01/12/2025 (Reviewer) Position Sachverständige(r)/Expert Position Sachverständige(r)/Expert Other: --- Condition of the test item at delivery: The test results reported in this test report shall refer only to the samples tested as received. TÜV Rheinland Italia is not responsible for the sampling phase. This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory TÜV Rheinland refuses any responsibility about information supplied by the customer contained in this test report (#) Test sample(s), as well sample information, description, product details and intended usage was provided by customer. TEST REPORT N. IT258LS3 001 Page 2 of 16 Issue Date: 01/12/2025 1 The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Unless otherwise agreed with the customer, a conformity assessment is always carried out based on the applied standards. At the customer's request, the statement on the conformity of the product tested in this test report is carried out according to the criteria/requirements of the applied standards. Evaluation conditions deviating from these are documented separately in the respective chapters. TEST REPORT N. IT258LS3 001 Page 3 of 16 Issue Date: 01/12/2025 0. Table of Contents 0. Table of Contents ...................................................................................................................................... 3 1. General description of test item(s) ............................................................................................................ 4 2. Reference documents ............................................................................................................................... 5 3. Equipment used during test....................................................................................................................... 6 4. Radio type identification ............................................................................................................................ 7 5. Operating modes ....................................................................................................................................... 8 6. EUT configuration ...................................................................................................................................... 8 7. Change history .......................................................................................................................................... 9 8. FCC SAR LIMITS ....................................................................................................................................... 10 9. SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm..................................................... 12 10. SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and > 50 mm ................................................ 13 11. SAR Test Exclusion Thresholds for < 100 MHz and < 200 mm ......................................................... 14 12. SAR Test Exclusion ............................................................................................................................ 15 TEST REPORT N. IT258LS3 001 Page 4 of 16 Issue Date: 01/12/2025 1. General description of test item(s) Identification / Type No.: EMBRACEMINI Serial number 3YMC4YY143 Manufacturer Empatica S.r.l. Trade Mark Rated voltage / frequency Battery equipment 5Vdc Rated current / power Battery equipment 3A max Equipment type Intentional radiator installed in a host equipment Number of phases N/A Hardware version Not provided by the customer Software version Not provided by the customer Dimensions 43 x 14 x 22 mm Weight 15 g Other --- Test sample obtaining: ☒ Sampling by customer ☐ Sampling by TÜV Rheinland Group ☐ others: TEST REPORT N. IT258LS3 001 Page 5 of 16 Issue Date: 01/12/2025 2. Reference documents 47 CFR § 1.1310 Radiofrequency radiation exposure limits 47 …

Text truncated - open the document above for the full version.

Test Report

The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2025. All rights reserved EmbraceMini – Antenna Information The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2025. All rights reserved Page 2 1. Scope The document contains the information related to the antenna included in the EmbraceMini device. 2. Antenna Type and Design Antenna Type: Sheet Metal Monopole Antenna The Embrace Mini antenna has been designed internally by Empatica. Figure 1 - Technical Drawing of the antenna The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2025. All rights reserved Page 3 Figure 2 - Antenna drawing with dimensions Figure 3 - Image of EmbraceMini antennas The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2025. All rights reserved Page 4 3. Antenna Characterization Antenna characterization has been performed. Below images related to its characterization. The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2025. All rights reserved Page 5 Antenna Maximum Gain: Frequency (MHz) 2402 2440 2480 Gain (dBi) -13.34 -12.35 -13.87

Test Report

00321 TEST REPORT N. IT25BAIT 001 Page 1 of 73 Issue Date: 21/10/2025 TEST REPORT FCC Part 15, Subpart C Par. 15.247 Radio frequency devices – Intentional Radiators Applicant: Empatica S.r.l. Via Stendhal 36 - 20144 Milano (MI – ITALY Test item: Wearable Actigraphy Identification / Type No.: EMBRACEMINI FCC ID: 2AGGH-MINI Order content: Full testing according to the following standard(s): Test specification: FCC Part 15, Subpart C (par. 15.247) Date of receipt: 03/09/2025 Internal storage No.: A004083685-001 (sampled by the customer) Testing period: 02/10/2025 Place of testing: TÜV Rheinland Italia S.r.l. Via E. Mattei, 3 20005 Pogliano Milanese (MI) - IT Testing laboratory: TÜV Rheinland Italia S.r.l. Via E. Mattei,3 20005 Pogliano Milanese (MI) - IT Test result: Pass Tested by: Zaccaria Piazza Authorized by: Riccardo Pfeiffer Date: 20/10/2025 (Laboratory technician) Date: 20/10/2025 (Reviewer) Position Sachverständige(r)/Expert Position Sachverständige(r)/Expert Other: --- The test results reported in this test report shall refer only to the samples tested as received. TÜV Rheinland Italia is not responsible for the sampling phase. This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory TÜV Rheinland refuses any responsibility about information supplied by the customer contained in this test report (#) Test sample(s), as well sample information, description, product details and intended usage was provided by customer. 00321 TEST REPORT N. IT25BAIT 001 Page 2 of 73 Issue Date: 21/10/2025 1 The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Unless otherwise agreed with the customer, a conformity assessment is always carried out based on the applied standards. At the customer's request, the statement on the conformity of the product tested in this test report is carried out according to the criteria/requirements of the applied standards. Evaluation conditions deviating from these are documented separately in the respective chapters. 00321 TEST REPORT N. IT25BAIT 001 Page 3 of 73 Issue Date: 21/10/2025 0. Table of Contents 0. Table of Contents .........................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alberto Poli
[email protected]Fax: 00390236553382

Technical Contact

Empatica Inc.Matteo Lai
[email protected]

1 Broadway · Cambridge, Massachusetts, 02142 · United States

Test Firm

TUV Rheinland Italia SRLGiovanni Molteni
[email protected]Fax: +39.02.939.687.23

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz40.00 µW
Confidentiality
Long Term