Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 | Remote Programming Manual 1, 5 & 15 Channel Remote Programming Manual Savant_Remote_ProgrammingManual_GL_v1.0_APR-2026 Remote Overview Key Symbol CH-P2CH+UPDOWNSTOP BackFront (Remote with LED) Front (Remote with LCD) Setting button (P2) Setting button (P2) 5 Channel Remote15 Channel Remote1 Channel Remote 2 | Remote Programming Manual WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. It is important for the safety of people to follow the enclosed instructions. Save these instructions for future reference. • Do not expose to water, moisture, humid and damp environments or extreme temperatures. • Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, should not be allowed to use this product. • Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Follow installation instructions. • For use with motorized shading devices. • Frequently inspect for improper operation. • Do not use if repair or adjustment is necessary. • Keep clear of the blind when in operation. • Replace battery with correctly specified type. • Non-rechargeable batteries are not to be recharged. • Do not force discharge, recharge, disassemble, heat above (manufacturer’s specified temperature rating) or incinerate. Doing so may result in injury due to venting, leakage or explosion resulting in chemical burns. • Ensure the batteries are installed correctly according to polarity (+ and -). • Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of time according to local regulations. Safety Instructions Compliance Statement Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. For US Market Add if mention radio frequency on eng drw Obsolete This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. 3 | Remote Programming Manual Press CH+ and CH- and hold on Press and hold CH+ and CH- at the same time for about 3S + + “ ” in screen “ ” in screen Battery: 3VDC (AAA battery×2) Battery life: >2 years Radio frequency: 433.92MHz Working temperature: -10°C~50°C Transmitting power: 10 mW Radio range: Outdoor > 150 meters, Indoor > 40 meters Note: 1. Either P2 button on back of Remote can be used. 2. The system will exit the settings and return to normal operation after 10 seconds of no activity. 3. Combo-Key is in unlocking status by factory default. Repeat same operations to switch unlock/lock status. 4. In locked status, the combo-keys don't work; In unlocked status,the combo-key will work normally. 5. If combo-key is locked, the only influence is that the Remote cannot send signals. Note: 1. Either P2 button on back of Remote can be used. 2. The factory default mode is Bi-directional mode, repeat the same operation to switch the mode circulary. Note: 1. In the setting status, press UP or DOWN button to exit quickly. 2. Repeat the same process if you want to adjust the number of channels. Remote without battery Hold P2 button and install the battery LED flashes once LED flashes twice Uni-directional mode Bi-directional mode Press STOP button more than 15S LED stay on P2×1 Slow flashing for 3S Quick flashing for 3S Locked status, combo-key is invalid Unlocked status, combo-key is available Technical specification Warning 1. Remote couldn't expose to moisture or be striked heavily, or else the Remote life will be affected. 2. During use, if you notice a significant decrease in the remote control distance, reduced sensitivity, or the low battery icon illuminating on the screen, please check whether the battery needs to be replaced. 3. When the voltage of DD3002H(HF) are lower than 2.65V, the battery icon will display, indicating low voltage. 4. In uni-directional mode, if you press any button more than 20S, or in bi-directional mode, you press any button for 5S, the Remote will stop sending radio sign…
Text truncated - open the document above for the full version.
092723-17 rev 10 Certification Application Attestation Statements Date: May 31, 2026 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) ______Rollease Acmeda Inc_____ certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) _____ Rollease Acmeda Inc certifies that, as of the date of the filing of this application, the applicant ☐ - is / ☒ - is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates – see KDB 986446 Question 5) as an entity producing “covered” equipment. The applicant also certifies that the device does not have cybersecurity and/or anti-virus software produced by Kaspersky Lab, Inc or any of its successors and assignees identified on the covered list installed on the device, nor will it be installed by the applicant at any time after certification. Thank you, By: __________________________ ______ Jonny Matuichuk _________ (Signature) (Print name) Title: ___ Product Manager ________________ Company: __ Rollease Acmeda Inc.___ Telephone: ___ +1 (203) 490-6191________
092723-17Rev9 U.S.AgentDesignationforServiceofProcess (ApplicantisBothGranteeandU.S.Agent) TO:AmericanCertificationBody,Inc. 313ParkAvenue Suite300 FallsChurch,VA22046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information This letter is to confirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information changes. Applicant Company name: Rollease Acmeda Inc FRN #: 0025043381 FCC ID: 2AGGZ003B9ACA66 Contact Name: JonnyMatuichuk Street Address: 750 East Main Street, 7th Floor City/Province/Zip: Stamford CT 06902 United States Telephone No: +1 (203) 490-6191 Email: [email protected] Applicant Signature 1 : Date:May 30,2026 Signed by (Printed Name/Title): Jonny Matuichuk
Authority to Act as Agent Date: May 12, 2026 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Intertek Testing Services (Shanghai FTZ) Co., Ltd is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: Dec 31, 2026 By: _______________ Jonny Matuichuk (Signature) (Print name) Title: Product Manager On behalf of: Rollease Acmeda Inc (Company Name) Telephone: +1 (203) 490-6191
Request for Confidentiality Date: May 31, 2026 Subject: Confidentiality Request for: __FCC ID: 2AGGZ003B9ACA66 Pursuant to FCC 47 CFR 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent Block Diagrams ☐ Short Term External Photos ☐ Short Term ☐ Permanent Internal Photos ☐ Short Term ☒ Permanent Operation Description/Theory of Operation ☐ Short Term ☐ Permanent Parts List & Placement/BOM ☐ Short Term ☐ Permanent Tune-Up Procedure ☐ Short Term ☒ Permanent Schematics ☐ Short Term Test Setup Photos ☐ Short Term ☐ Permanent User’s Manual ______ Rollease Acmeda Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___ ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: Jonny Matuichuk (Signature/Title) (Print name)
Declaration Letter Related FCC ID: 2AGGZ003B9ACA66, IC: 21769-003B9ACA66 Justification statement stating that all measurements for RF part were performed by radiated method and therefore additional antenna gain documentation is not required for RF part. See “internal photo” for the details of the antenna. By: ______________ ____Teddy Yin ______ (Signature) (Print name) Title: ____Supervisor________ Company: ____Intertek Testing Services (Shanghai FTZ) Co., Ltd.________
FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 1 of 3 External Picture FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 2 of 3 FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 3 of 3
Product Label Location SCALE 1:2 C PROPRIETARY & CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE ACMEDA. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ROLLEASE ACMEDA IS PROHIBITED. COPYRIGHT 2026 DIMENSIONS IN MILLIMETERS DRAWN BY: DRAWN DATE: APPROVED BY: DRAWING NUMBER: PART NUMBER: TITLE: DO NOT SCALEDWG 1 OF 1 SCALE 1:1 REV. SIZE: A4 PRODUCT MANAGERPROJECT LEADCOMPLIANCE ENGINEER ITEM NO.DESCRIPTION 1PRODUCT LABEL 2PACKAGING LABEL REVDESCRIPTIONDRAWN BYPROJECTDATE 1.0New label created (pre-compliance)D.RNPD-2601415 APR 2026 min. 7mm height 25.00 75.00 C Label Location 25.00 75.00 PROPRIETARY & CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE ACMEDA. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ROLLEASE ACMEDA IS PROHIBITED. A4 - SIZE: REV. SCALE:1:2 DIMENSIONS IN "MM" ROLLEASE ACMEDA 14 Apr 2026 DRAWN: www.rolleaseacmeda.com NOT SPECIFIEDITEM DESCRIPTION: LABEL LOCATION SHEET ITEM CODE: Scale 1:2 MT02-0101-067031_PLAB MT02-0101-067031_PLAB SAVANT | 15 CHANNEL REMOTE | WHITE 1.0 NOTES FOR PRINTING: 1 TRANSPARENT LABEL 35mm 20mm PRODUCT LABEL ing WEEE LOGO For US Market min. 7mm height SAVANT | 15 Channel Remote | White MT02-0101-067031 FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 AAA | 1.5V x 2 9.5W X 7.5H D. RAJPUT15 APR 2026 WEEE LOGO For US Market min. 7mm height SAVANT | 15 Channel Remote | White MT02-0101-067031 FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 AAA | 1.5V x 2 9.5W X 7.5H
FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 1 of 2 Internal Picture antenna FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 2 of 2
Rollease Acmeda Inc SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: MT02-0101-067031 REPORT NUMBER: 2605B0469SHA-002 ISSUE DATE: Jun 2, 2026 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V1 © 2018 Intertek Intertek Testing Services (Shanghai FTZ) Co., Ltd. Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCSAR-01_V1© 2018 Intertek Page 2 of 8 Report no.: 2605B0469SHA-002 Applicant: Rollease Acmeda Inc 750 East Main Street, 7th Floor, Stamford CT 06902 United States Manufacturer: Rollease Acmeda Inc 750 East Main Street, 7th Floor, Stamford CT 06902 United States FCC ID: 2AGGZ003B9ACA66 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Teddy Yin Reviewer Wakeyou Wang Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 3 of 8 Revision History Report No. Version Description Issued Date 2605B0469SHA-002 Rev. 01 Initial issue of report Jun 2, 2026 Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 4 of 8 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Remote Type/Model/PMN/HVIN: MT02-0101-067031 Description of EUT: The EUT can transmit 433.92MHz signal. Rating: DC 3V Category of EUT: Class B EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample Identification No.: A260508-27-005 Sample received date: May 11, 2026 Date of test: May 11~19, 2026 1.2 Technical Specification Operation Frequency: 433.92MHz Type of Modulation: FSK Product Type: Mobile Portable Fix Location Channel Number: 1 Antenna Information: PCB antenna(declared by the manufacturer) Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 5 of 8 1.3 Description of Test Facility Name: Intertek Testing Services (Shanghai FTZ) Co., Ltd. Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L21189 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 6 of 8 2 SAR Assessment Test result: Pass 2.1 SAR Test Exclusion Limit 100 MHz – 6 GHz and ≤ 50 mm Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 7 of 8 100 MHz – 6 GHz and > 50 mm < 100 MHz and < 200 mm Report No.: 2605B0469SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 8 of 8 2.2 Assessment Results Seen from the test report 2605B0469SHA-001: Field Strength Antenna Gain EIRP dBuV/m dBi mW 80.30 / 0.032 Note: EIRP= E-95.3 where: E=electric field strength in dBuV/m, EIRP= equivalent isotropic radiated power The highest EIRP adjusted with tune-up tolerance is 0.032< 22mW (Test Exclusion Thresholds of 450MHz at 5mm). Therefore, the SAR requirement is deemed to be satisfied without test. ******************************************* END ************************************
Rollease Acmeda Inc RF TEST REPORT Report Type: FCC Part 15.231 & ISED RSS-210 RF report Model: MT02-0101-067031 REPORT NUMBER: 2605B0469SHA-001 ISSUE DATE: Jun 2, 2026 DOCUMENT CONTROL NUMBER: TTRF15.231_V1 © 2018 Intertek Intertek Testing Services (Shanghai FTZ) Co., Ltd. Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.231_V1 © 2018 Intertek Page 2 of 26 Report no.: 2605B0469SHA-001 Applicant: Rollease Acmeda Inc 750 East Main Street, 7th Floor, Stamford CT 06902 United States Manufacturer: Rollease Acmeda Inc 750 East Main Street, 7th Floor, Stamford CT 06902 United States FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2024): Radio Frequency Devices (Subpart C) ANSI C63.10 (2020)+Cor.1(2023)+C63.10a(2024)+Errata to C63.10a(2024): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-210 Issue 11 (June 2024): Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment RSS-Gen Issue 5 (April 2018)+A1(March 2019)+A2(February 2021): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Teddy Yin Reviewer Wakeyou Wang Report No.: 2605B0469SHA-001 TEST REPORT TTRF15.231_V1 © 2018 Intertek Page 3 of 26 Content REVISION HISTORY................................................................................................................................................ 4 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 5 1 GENERAL INFORMATION ............................................................................................................................. 6 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 6 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 7 2 TEST SPECIFICATIONS ................................................................................................................................... 8 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 8 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 8 2.3 TEST SOFTWARE LIST ............................................................................................................................................ 8 2.4 TEST PERIPHERALS LIST ......................................................................................................................................... 8 2.5 TEST ENVIRONMENT CONDITION: ............................................................................................................................ 8 2.6 INSTRUMENT LIST ................................................................................................................................................ 9 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 10 3 FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ...................................... 11 3.1 LIMIT .............................................................................................................................................................. 11 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 12 3.3 TEST CONFIGURATION ........................................................................................................................................ 13 3.4 TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 15 4 POWER LINE CONDUCTED EMISSION ......................................................................................................... 19 4.1 LIMIT .............................................................................................................................................................. 19 4.2 TEST CONFIGURATION ........................................................................................................................................ 19 4.3 MEASUREMENT PROCEDURE ............................................................................................................................... 20 4.4 TEST RESULTS O…
Text truncated - open the document above for the full version.
FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 1 of 2 Test Setup FCC ID: 2AGGZ003B9ACA66 IC: 21769-003B9ACA66 Page 2 of 2 1. Radiated Emission Above 1GHz Below 1GHz
750 East Main Street, 7th Floor · Stamford, Connecticut, 06902 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |