Rev1/26/2023 AutelRoboticsCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025-11-12 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID: 2AGNTDF25 AutelRoboticsCo.,Ltd. (“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtis not“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules. AutelRoboticsCo.,Ltd.(“theapplicant”)certifiesthattheequipmentforwhichauthorizationissought doesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.orany ofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, XiangxiPan Rev1/26/2023 AutelRoboticsCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025-11-12 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AGNTDF25 AutelRoboticsCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered”equipment. Sincerely, XiangxiPan
UNITEDSTATESDESIGNATEDAGENTLETTER Date:November3,2025 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 ApplicantU.S.designatedagent CompanyName:AutelRoboticsCo.,Ltd.CompanyName: AutelRoboticsUSALLC ContactName:XiangxiPanContactName: MrJimmyGuo Address:601,701,801,901,BlockB1, NanshaniPark,No. 1001XueyuanAvenue,Nanshan District Address: 2252229THDRSE101 Bothell, City/Province/Zip:Shenzhen,Guangdong,518055, China City/Province/Zip: WA98021UnitedStates Telephone:86-13975522238Telephone: (866)692-8835 Email:[email protected]: [email protected] FRN:0025070863FRN: 0033458068 Applicable Equipment: FCC ID: 2AGNTDF25 ATTN: Director of Certification: We, <Autel Robotics Co., Ltd. > and <Autel Robotics USA LLC> understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, < Autel Robotics Co., Ltd. > and <Autel Robotics USA LLC> acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. ApplicantU.S.designatedagent Name(Printed):XiangxiPanName(Printed):JimmyGuo Title:PresidentTitle:Manager Signature:Signature:
AutelRoboticsCo.,Ltd. 601,701,801,901,BlockB1,NanshaniPark,No.1001XueyuanAvenue,Nanshan District,Shenzhen,Guangdong,518055,China Date:2025-11-12 SUBJECT:FCCID:2AGNTDF25 ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, AutelRoboticsCo.,Ltd. ------------------------------- XiangxiPan
Rev11/20/07 AutelRoboticsCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2AGNTDF25 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName* BlockDiagram,SCH,Operation Description , BOM , Layout , BlockDiagram.pdf, SCH.rar BOM.pdf OperationDescription.pdf SoftwareSecurityOperationalDescriptionSoftwareSecurityOperational Description(2).pdf Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. Werequestthefollowingattachmentstobekeptconfidentialforashortperiodoftimewithin 180daysfromthedateofsubmittingtheFCCID. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName* TestSetupPhotosTestSetupPhotos.pdf usermanualsusermanuals.pdf ExternalPhotos , InternalPhotos ExternalPhotos.pdf InternalPhotos.pdf Sincerely, Rev11/20/07 XiangxiPan
FCC ID:2AGNTDF25 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation.
DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] RFExposureEvaluationReport ApplicationNo.: DNT2509290857R11082-13718 Applicant: AutelRoboticsCo.,Ltd. AddressofApplicant: 601,701,801,901,BlockB1,NanshaniPark,No.1001Xueyuan Avenue,NanshanDistrict,Shenzhen,Guangdong,518055,China EUTDescription: Dragonfish-25 ModelNo.: DF-25 AdditionalModel(s): / FCCID: 2AGNTDF25 Powersupply Li-ionBattery43.2V,28500mAh,1231.2Wh*2 TradeMark: AUTELROBOTICS Standards: 47CFRPart2.1091 FCCKDB447498D01v06 DateofReceipt: 2025/9/29 DateofTest: 2025/9/30to2025/11/10 DateofIssue: 2025/11/11 TestResult: PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:Ifthereisanyobjectiontotheresultsinthisreport,pleasesubmitawritteninquirytothecompanywithin15daysfromthedateof receivingthereport.Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,andisissuedbythecompanyinaccordance withtherequirementsofthe"ConditionsofIssuanceofTestReports"printedintheattachedpage.Unlessotherwisestated,theresults presentedinthisreportonlyapplytothesamplestestedthistime.Partialreproductionofthisreportisnotallowedunlessapprovedbythe companyinwriting. ReportNo.:DNT2509290857R11082-13719Date:November11,2025Page: 2 / 10 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Nov.11,2025ValidOriginalReport ReportNo.:DNT2509290857R11082-13719Date:November11,2025Page: 3 / 10 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Contents 1GENERALINFORMATION.......................................................................................................................4 1.1TESTLOCATION..................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT.........................................................................................................4 2RFEXPOSUREEVALUATION.................................................................................................................5 2.1RFEXPOSURECOMPLIANCEREQUIREMENT........................................................................................5 2.1.1Limits.............................................................................................................................................5 2.1.2TestProcedure.............................................................................................................................6 2.1.3EUTRFExposureEvaluation.......................................................................................................6 ReportNo.:DNT2509290857R11082-13719Date:November11,2025Page: 4 / 10 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1GeneralInformation 1.1TestLocation Company:DongguanDNTestingCo.,Ltd Address: No.1,WestFourthStreet,SouthXinfaRoad,WushaLiwu,Chang'anTown, DongguanCity,GuangdongP.R.China Testengineer:WayneLin 1.2GeneralDescriptionofEUT Manufacturer:AutelRoboticsCo.,Ltd. AddressofManufacturer: 601,701,801,901,BlockB1,NanshaniPark,No.1001Xueyuan Avenue,NanshanDistrict,Shenzhen,Guangdong,518055,China Factory:AutelRoboticsCo.,Ltd.GuangmingBranch Addressoffactory: Electronicplanteastside701,West701Building3,Yanxiang TechnologyIndustrialPark,GaoxinRoad,DongzhouCommunity,Guangming Street,GuangmingDistrict,ShenzhenCity,Guangdong Province,P.R.China EUTDescription:Dragonfish-25 TestModelNo.:DF-25 AdditionalModel(s): / PowerSupply:Li-ionBattery43.2V,28500mAh,1231.2Wh*2 TradeMark:AUTELROBOTICS HardwareVersion: V1.0 SoftwareVersion: V1.0 SampleType:PortableDevice,Module,MobileDevice AntennaType:ExternalAntenna AntennaPorts: Ant1,Ant2,Ant3 AntennaGain: Providedbyapplicant Fortransferimage: Ant1:5.1dBi(900MHz),3.1dBi(2.4GHz);0.5dBi(5GHz) Ant2:5dBi(900MHz),2.1dBi(2.4GHz);2dBi(5GHz) For5.8Gdatatransmission Ant1:2.2dBi Note: *Sincetheabovedataand/orinformationisprovidedbytheclientrelevantresultsorconclusionsofthis reportareonlymadeforthesedataand/orinformation,DNTisnotresponsiblefortheauthenticity,integrity andresultsofthedataandinformationand/orthevalidityoftheconclusion. *Allmodelsarejustcolordifferences,motherboard,PCBcircuitboard,chip,electroniccomponents,app earanceisallthesame. ReportNo.:DNT2509290857R11082-13719Date:November11,2025Page: 5 / 10 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 2RFExposureEvaluation 2.1RFExposureComplianceRequirement 2.1.1Limits Frequencyrange (MHz) Electricfieldstrength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm2) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3-3.06141.63*(100)6 3.0-301842/f4.89/f*(900/f2)6 30-30061.40.1631.06 300-1500//f/3006 1500-100,000//56 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*(100)30 1.34-30824/f2.19/f*(180/f2)30 30-30027.50.0730.230 300-1500//f/150030 1500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity RFexposurecompliancewillneedtobedeterminedwithrespectto1.1307(c)and(d)oftheFCCrules.The emissionsshouldbewithinthelimitsat300kHzinTable1of1.1310(usethe300kHzlimitsfor 150kHz:614V/m,1.63A/m). FriisFormula Friistransmissionformula:Pd=(Pout*G)/(4*Pi*R2) Where Pd=powerdensityinmW/cm2 Pout=outputpowertoantennainmW G=gainofantennainlinearscale Pi=3.1416 R=distanceb…
Text truncated - open the document above for the full version.
规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2024/11/28 编号 File No 24112807 版本 Revision 1.0 客户 CUSTOMER: 道通 客户料号 CUSTOMER NO: 品名 PARTNAME: RF Antenna 供方料号 SUPPLIERNO: YJI01.005.100.307A 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 SUPPLIERNO: YJI01.005.100.307A 送样日期Date: 送样数量Q'TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 2 承认书项目表( Spec Item ) 12 3 工程成品图( Drawing) 13 4 天线规格( Antenna Specification) 14 5 S参数测试(S Parameter ) 15 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 5 S参数测试(S Parameter ) 15 6 无源测试(Passive Test ) 66 ~ 11 7 方向图(Radiation Pattern ) 612 ~ 17 8 天线装配图(Antenna Profile) 218 ~ 19 9 材质证明(Material Certificate ) 3320 ~ 52 10 RoHS报告(RoHSTest Report ) **** 11N/AN/AN/A 12--- 13--- 天线规格 Antenna Specification Electrical Properties Frequency 830-930MHz 1090-1440MHz 2.4-2.5GHz 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R 3.0 Max@830-930MHz 4.5 Max@1090-1440MHz 2.0 [email protected] 2.5 [email protected] 5.1 dBi@830-930MHz 3.5 dBi@1090-1440MHz 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Gain 3.5 dBi@1090-1440MHz 3.1 [email protected] 0.5 [email protected] RadiationOmni-directional PolarizationLinear Physical Properties ConnectorSSMA Male Cable TypeRG 178 Cable Length623mm Cable ColorBrown Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Agilent E5071C S Antenna Performance Test 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 S Parameter Test // R Antenna Antenna Passive Test Z Y X Z Y X 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Y X Z Y X Z Passive Test For Antenna-R Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 82041.1-3.92.3 83056.4-2.52.7 84064.1-1.92.8 85063.1-2.02.7 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 86069.1-1.62.8 87075.5-1.22.8 88079.2-1.03.5 89080.8-0.94.5 90081.9-0.95.1 91068.6-1.64.1 92069.9-1.63.6 93065.5-1.82.8 94062.0-2.12.4 95060.4-2.22.0 96060.0-2.22.1 Passive Test For Antenna-R Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 105020.7-6.8-2.9 105818.2-7.4-3.5 106611.4-9.4-4.8 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 10749.8-10.1-5.7 108220.7-6.8-2.2 109033.9-4.7-0.3 109837.9-4.20.0 110637.2-4.3-0.2 111435.3-4.5-0.6 112233.1-4.8-1.4 113032.5-4.9-1.2 Passive Test For Antenna-R Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 143081.0-0.93.5 143882.5-0.83.4 144683.9-0.83.3 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 145482.6-0.83.2 146281.5-0.93.2 147077.7-1.13.1 147872.4-1.42.9 148667.7-1.72.7 149464.8-1.92.6 150263.3-2.02.5 151061.2-2.12.2 Passive Test For Antenna-R Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 240056.8-2.52.9 241057.8-2.43.0 242057.9-2.43.0 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 243056.5-2.52.9 244056.2-2.52.8 245060.5-2.23.1 246061.9-2.13.0 247063.7-2.03.1 248063.2-2.02.9 249061.9-2.12.5 250060.3-2.22.1 Passive Test For Antenna-R Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 515014.6-8.4-2.5 520025.4-6.00.0 525024.8-6.1-0.2 530023.0-6.4-0.5 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 535027.9-5.60.5 540027.9-5.60.4 545023.8-6.2-0.7 550027.5-5.6-0.3 555029.5-5.3-0.4 560021.2-6.7-1.5 565025.4-6.0-1.6 570028.5-5.5-0.8 575017.9-7.5-1.7 580011.3-9.5-3.2 585013.1-8.8-2.1 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-R 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Device 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 R Antenna 化学品安全技术说明书MSDS 第一部分、化学品物品及企业标识Part1IdentificationsofchemicalsandManufacturer 化学品物品名称Chemicalname: 液态感光阻焊油墨YSR-900 Liquidphotosensitivesoldermask YSR-900 生效日期Effectivedate:2022.7.1 企业名称Manufacturername: 肇庆超阳电子科技有限公司 ZhaoqingchaoyangElectronictechnologyCo.,Ltd 地址Address: 肇庆市高要区蚬岗镇工业区 Xian’gangIndustrialZone,Gaoyaodistrict,Zhaoqingcity 电话Tel:0758-8384062 传真Fax:0758-8384063 [email protected] 应急咨询电话Emergencycall:0758-8384062 推荐用途Recommendationsonusage:用于PCB制作PCBManufactoring 限制用途Restrictionsonusage:仅限工业用ndustrialuseonly 第二部分、危险性概述Part2Summaryofdanger GHS危险性类别Riskclassification: 急性毒性-经口类别5Acutetoxicity-Oraltype5 呼吸或皮肤过敏类别1Respiratoryorskinirritationtype1 对水环境的急性危害类别3Acutehazardtothewaterenvironmenttype3 对水环境的慢性危害类别3Chronicharmtothewaterenvironmenttype3 GHS标签要素: 信号词:警告Signal:Warning 危险说明:Hazardstatement: 最重要的危害效应 Mostdangeroushazard 刺激性(皮肤、粘膜),麻醉作用、肾脏障害,经皮肤侵入人体 Irritation(skin,mucousmembrane),anesthesia,kidneydamage, invadingthebodythroughtheskin 环境影响Environmental有机溶剂蒸发Organicsolventevaporation 物理性及化学性危害Physical& Chemical 其蒸气比空气轻,易传播至远处。Itsvaporislighterthanairand easilyspreadtodistantplaces. 特殊危害 SpecialHazard 吸入性伤害及口、鼻、黏膜等接触性伤害Inhalationinjuryandcontact injurysuchasmouth,noseandmucousmembrane 主要症状 Mainsymptoms 口、鼻、粘膜等发生刺激感、吸入过量导致晕眩感Irritationinthemouth, nose,mucousmembranes,etc. 第三部分、成分/组成信息Part3Informationofingredients 物料主要成分明细:Detailsofmaincomponentsofmaterials: 主要成分名称MainingredientnameCASNO.主要成分百分含量Percentage 环氧树脂Epoxyresin25068-38-635-40 二丙二醇甲醚DPM34590-94-810-26 硫酸钡Bariumsulfate7727-43-720-30 二氧化硅Silica7631-86-93-5 双季戊四醇六丙烯酸酯DPHA1499-10-16-8 第四部分、急救措施Part4Emergencymeasures 不同暴露途径之急救方法:(主要为溶剂性伤害,应于第一时间主动告知医师)Firstaidmethodsfordifferent exposureroutes:(mainlyforsolventinjuries,youshouldtaketheinitiativetoinformthephysician immediately) 吸入:1、若有头痛、头晕,应把患者立即移至新鲜空气处Breathein:1、Ifyouhaveheadacheordizziness, movethepatienttofreshairimmediately 2、并接受医师诊治Seeyourdoctor. 皮肤接触:1、用纱布擦拭,再用中性肥皂彻底冲洗。如果发炎,则应立即就医Skintouch:1Wipewithgauzeand rinsethoroughlywithneutralsoap.Ifirritationoccurs,seekmedicalattentionimmediately 眼睛接触:立即以大量流水冲洗15分钟以上,再接受专科医师的诊治Eyestou…
Text truncated - open the document above for the full version.
规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2024/11/28 编号 File No 24112808 版本 Revision 1.0 客户 CUSTOMER: 道通 客户料号 CUSTOMER NO: 品名 PARTNAME: RF Antenna 供方料号 SUPPLIERNO: YJI01.005.100.308A 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 SUPPLIERNO: YJI01.005.100.308A 送样日期Date: 送样数量Q'TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 2 承认书项目表( Spec Item ) 12 3 工程成品图( Drawing) 13 4 天线规格( Antenna Specification) 44 5 S参数测试(S Parameter ) 45 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 5 S参数测试(S Parameter ) 45 6 无源测试(Passive Test ) 66 ~ 11 7 方向图(Radiation Pattern ) 612 ~ 17 8 天线装配图(Antenna Profile) 218 ~ 19 9 材质证明(Material Certificate ) 3320 ~ 52 10 RoHS报告(RoHSTest Report ) **** 11N/AN/AN/A 12--- 13--- 天线规格 Antenna Specification Electrical Properties Frequency 830-930MHz 1090-1440MHz 2.4-2.5GHz 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R 2.5 Max@830-930MHz 4.5 Max@1090-1440MHz 2.0 [email protected] 2.0 [email protected] 5.0 dBi@830-930MHz 3.9 dBi@1090-1440MHz 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Gain 3.9 dBi@1090-1440MHz 2.1 [email protected] 2.0 [email protected] RadiationOmni-directional PolarizationLinear Physical Properties ConnectorSSMA Male Cable TypeRG 178 Cable Length573mm Cable ColorBrown Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Agilent E5071C S Antenna Performance Test 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 S Parameter Test // L Antenna Antenna Passive Test Z Y X Z Y X 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Y X Z Y X Z Passive Test For Antenna-L Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 82040.3-4.00.2 83054.0-2.71.3 84060.2-2.21.4 85057.9-2.41.0 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 86057.7-2.41.0 87066.3-1.81.2 88071.0-1.51.5 89072.0-1.42.1 90078.8-1.05.0 91065.5-1.83.3 92067.1-1.72.9 93063.9-1.92.3 94062.2-2.12.2 95060.8-2.22.3 96060.7-2.22.2 Passive Test For Antenna-L Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 105016.4-7.9-4.4 105814.8-8.3-4.4 106612.9-8.9-4.2 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 107414.4-8.4-4.0 108224.5-6.1-1.8 109036.1-4.4-0.6 109841.2-3.9-0.4 110641.6-3.8-0.8 111440.0-4.0-0.2 112237.1-4.3-0.3 113035.9-4.5-0.3 Passive Test For Antenna-L Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 143071.3-1.53.6 143872.2-1.43.8 144673.3-1.43.9 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 145472.5-1.43.7 146271.6-1.53.4 147068.9-1.63.1 147865.0-1.92.6 148661.2-2.12.2 149459.3-2.31.9 150258.4-2.31.8 151056.7-2.51.5 Passive Test For Antenna-L Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 240050.2-3.01.9 241049.8-3.01.8 242049.7-3.01.8 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 243048.9-3.11.7 244049.0-3.11.6 245053.0-2.82.1 246053.8-2.72.1 247055.6-2.62.1 248055.6-2.61.9 249055.5-2.61.6 250055.7-2.51.3 Passive Test For Antenna-L Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 515015.1-8.2-2.4 520022.7-6.4-1.9 525028.1-5.5-1.1 530026.2-5.8-1.3 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 535025.7-5.9-0.6 540028.6-5.4-0.4 545029.3-5.30.0 550028.2-5.5-0.6 555029.3-5.30.4 560031.8-5.01.1 565038.3-4.21.2 570035.4-4.51.2 575034.7-4.62.0 580029.8-5.31.5 585028.5-5.51.3 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For Antenna-L 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 Device 东莞市长安镇沙头社区木鱼路59号Tel:0769-82586086 Fax:0769-82586086 L Antenna 化学品安全技术说明书MSDS 第一部分、化学品物品及企业标识Part1IdentificationsofchemicalsandManufacturer 化学品物品名称Chemicalname: 液态感光阻焊油墨YSR-900 Liquidphotosensitivesoldermask YSR-900 生效日期Effectivedate:2022.7.1 企业名称Manufacturername: 肇庆超阳电子科技有限公司 ZhaoqingchaoyangElectronictechnologyCo.,Ltd 地址Address: 肇庆市高要区蚬岗镇工业区 Xian’gangIndustrialZone,Gaoyaodistrict,Zhaoqingcity 电话Tel:0758-8384062 传真Fax:0758-8384063 [email protected] 应急咨询电话Emergencycall:0758-8384062 推荐用途Recommendationsonusage:用于PCB制作PCBManufactoring 限制用途Restrictionsonusage:仅限工业用ndustrialuseonly 第二部分、危险性概述Part2Summaryofdanger GHS危险性类别Riskclassification: 急性毒性-经口类别5Acutetoxicity-Oraltype5 呼吸或皮肤过敏类别1Respiratoryorskinirritationtype1 对水环境的急性危害类别3Acutehazardtothewaterenvironmenttype3 对水环境的慢性危害类别3Chronicharmtothewaterenvironmenttype3 GHS标签要素: 信号词:警告Signal:Warning 危险说明:Hazardstatement: 最重要的危害效应 Mostdangeroushazard 刺激性(皮肤、粘膜),麻醉作用、肾脏障害,经皮肤侵入人体 Irritation(skin,mucousmembrane),anesthesia,kidneydamage, invadingthebodythroughtheskin 环境影响Environmental有机溶剂蒸发Organicsolventevaporation 物理性及化学性危害Physical& Chemical 其蒸气比空气轻,易传播至远处。Itsvaporislighterthanairand easilyspreadtodistantplaces. 特殊危害 SpecialHazard 吸入性伤害及口、鼻、黏膜等接触性伤害Inhalationinjuryandcontact injurysuchasmouth,noseandmucousmembrane 主要症状 Mainsymptoms 口、鼻、粘膜等发生刺激感、吸入过量导致晕眩感Irritationinthemouth, nose,mucousmembranes,etc. 第三部分、成分/组成信息Part3Informationofingredients 物料主要成分明细:Detailsofmaincomponentsofmaterials: 主要成分名称MainingredientnameCASNO.主要成分百分含量Percentage 环氧树脂Epoxyresin25068-38-635-40 二丙二醇甲醚DPM34590-94-810-26 硫酸钡Bariumsulfate7727-43-720-30 二氧化硅Silica7631-86-93-5 双季戊四醇六丙烯酸酯DPHA1499-10-16-8 第四部分、急救措施Part4Emergencymeasures 不同暴露途径之急救方法:(主要为溶剂性伤害,应于第一时间主动告知医师)Firstaidmethodsfordifferent exposureroutes:(mainlyforsolventinjuries,youshouldtaketheinitiativetoinformthephysician immediately) 吸入:1、若有头痛、头晕,应把患者立即移至新鲜空气处Breathein:1、Ifyouhaveheadacheordizziness, movethepatienttofreshairimmediately 2、并接受医师诊治Seeyourdoctor. 皮肤接触:1、用纱布擦拭,再用中性肥皂彻底冲洗。如果发炎,则应立即就医Skintouch:1Wipewithgauzeand rinsethoroughlywithneutralsoap.Ifirritationoccurs,seekmedicalattentionimmediately 眼睛接触:立即以大量流水冲洗15分钟以上,再接受专科医师的诊治Eyestouch:I…
Text truncated - open the document above for the full version.
Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] FCC Test Report Application No.: DNT2509290857R11082-13719 Applicant: Autel Robotics Co., Ltd. Address of Applicant: 601,701,801,901, Block B1, Nanshan iPark, No. 1001 Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, 518055, China EUT Description: Dragonfish-25 Model No.: DF-25 FCC ID: 2AGNTDF25 Power Supply Li-ion Battery 43.2V, 28500mAh, 1231.2Wh*2 Trade Mark: AUTEL ROBOTICS Standards: 47 CFR FCC Part 2, Subpart J 47 CFR Part 15, Subpart C ANSI C63.10: 2020 Date of Receipt: 2025/9/29 Date of Test: 2025/9/30 to 2025/10/29 Date of Issue: 2025/10/29 Test Result: PASS Prepared By: (Testing Engineer) Reviewed By: (Project Engineer) Approved By: (Manager) Note: If there is any objection to the results in this report, please submit a written inquiry to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp, and is issued by the company in accordance with the requirements of the "Conditions of Issuance of Test Reports" printed in the attached page. Unless otherwise stated, the results presented in this report only apply to the samples tested this time. Partial reproduction of this report is not allowed unless approved by the company in writing. Report No.: DNT2509290857R11082-13719 Date:October 29, 2025 Page:2 / 214 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Oct.29, 2025 Valid Original Report Report No.: DNT2509290857R11082-13719 Date:October 29, 2025 Page:3 / 214 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] 1 Test Summary Test Item Test Requirement Test Method Test Result Result Antenna Requirement 15.203/247(b) -- Clause 3.1 PASS AC Power Line Conducted Emission 15.207 ANSI C63.10: 2020 Clause 3.2 N/A Duty Cycle -- -- Clause 3.3 PASS DTS (6 dB) Bandwidth 15.247 (a)(2) ANSI C63.10: 2020 Clause 3.4 PASS Conducted Output Power 15.247 (b)(3) ANSI C63.10: 2020 Clause 3.5 PASS Power Spectral Density 15.247 (e) ANSI C63.10: 2020 Clause 3.6 PASS Band-edge for RF Conducted Emissions 15.247(d) ANSI C63.10: 2020 Clause 3.7 PASS RF Conducted Spurious Emissions 15.247(d) ANSI C63.10: 2020 Clause 3.8 PASS Radiated Spurious Emissions 15.247(d);15.205/15.209 ANSI C63.10: 2020 Clause 3.9 PASS Restricted bands around fundamental frequency (Radiated Emission) 15.247(d);15.205/15.209 ANSI C63.10: 2020 Clause 3.10 PASS Note: 1. “N/A” denotes test is not applicable in this test report. Report No.: DNT2509290857R11082-13719 Date:October 29, 2025 Page:4 / 214 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Contents 1 Test Summary .................................................................................................................................................................. 3 2 General Information ......................................................................................................................................................... 5 2.1 Test Location ......................................................................................................................................................... 5 2.2 General Description of EUT ................................................................................................................................... 6 2.3 Channel List ........................................................................................................................................................... 7 2.4 Test Environment and Mode ................................................................................................................................. 8 2.5 Power Setting of Test Software ............................................................................................................................. 8 2.6 Description of Support Units .................................................................................................................................. 9 2.7 Test Facility ............................................................................................................................................................ 9 2.8 Measurement Uncertainty (95% confidence levels, k=2) ...................................................................................... 9 2.9 Equipment List ..................................................................................................................................................... 10 2.10 Assistant equipment used for test ..................................................................................................................... 11 3 Test results and Measurement Data .............................................................................................................................. 12 3.1 Antenna Requirement ......................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 904 MHz - 926 MHz | 219.00 mW |
| 2 | 15C | 909 MHz - 921 MHz | 150.00 mW |
| 3 | 15C | 914 MHz - 916 MHz | 147.00 mW |
| 4 | 15C | 2.40 GHz - 2.48 GHz | 210.00 mW |
| 5 | 15C | 2.41 GHz - 2.47 GHz | 218.00 mW |
| 6 | 15C | 2.41 GHz - 2.46 GHz | 220.00 mW |