FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Anelto, Inc./
  3. 2AGPI-ANH0822

2AGPI-ANH0822LTE CAT M Handset

Anelto, Inc.
LTE CAT M Handset - FCC ID 2AGPI-ANH0822 - Anelto, Inc.
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Nov 07, 2022
Application Purpose
Original Equipment
Date of Application
Nov 07, 2022
Equipment Note
LTE CAT M Handset
Frequency Range
699.20000000 - 715.80000000
Company
Anelto, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—
β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Anelto – OnTheGo Mini User Guide Version 2.0 Confidential – Do not duplicate or distribute without written permission from Anelto, Inc Anelto Confidential 2 Contents Overview ........................................................................................................................ 3 Key Features .................................................................................................................. 3 Specifications ................................................................................................................ 3 Getting to Know Your OnTheGo Mini:......................................................................... 4 Charging Your Device: ................................................................................................. 4 Checking Device Registration Status: ......................................................................... 6 Placing an Emergency Call: ........................................................................................ 7 Turning your device OFF: .............................................................................................. 8 Turning your device ON again: ................................................................................... 8 Welcome Announcement: .......................................................................................... 8 Important Tips and Reminders: .................................................................................... 9 Warnings: ....................................................................................................................... 9 REVISION TABLE: ........................................................................................................... 14 Anelto Confidential 3 Overview The OnTheGo Mini from Anelto is the perfect companion for seniors and other at-risk individuals in need of a fall- detection and emergency-call solution. It can be worn around the wrist or neck and is available in multiple, stylish colors. If the device detects a fall or the middle button is pressed, it will automatically dial a pre-defined emergency number to connect the person with the appropriate call center. Audio from the operator comes through loudly and clearly while allowing the wearer to easily reply without pressing any other buttons. During this time, the OnTheGo Mini also sends the wearer’s location so emergency services can be dispatched. In addition to the above features, the OnTheGo Mini is capable of tracking activity of the wearer. This information is sent to the Anelto RemoteCare clinical dashboard where the clinician can view general trends in activity and intervene with a patient before a downward trend turns into a bigger problem. Key Features β€’ Very small and light β€’ Easy-to-use – 1 Call button β€’ LTE Cat M1 cellular β€’ Fall detection β€’ High-quality microphone and speaker β€’ Wireless charging β€’ Location tracking via GPS and Wi-Fi β€’ Wear while swimming or bathing β€’ Available in multiple colors and wearing styles Specifications Part Number Cellular LTE Cat M1 (B2/B4/B12) with an Embedded SIM Indoor Location Wi-Fi for location assistance Battery Life TBD Charge Time TBD Activity and Fall Detection IMU accelerometer and gyro Dimensions 2.0” x 1.6” x 0.6” (50mm x 42mm x 16mm) Waterproof Rating IP67 (submerged in 3m of water for 30 minutes) Anelto Confidential 4 Getting to Know Your OnTheGo Mini: 1) Lanyard Loop 2) Speaker 3) Signal LED 4) Power LED 5) HELP Button (Emergency Button) 6) Microphone 7) Lanyard (Not Shown) Charging Your Device: The OTG Mini uses any Qi-compatible inductive charging solution. Whenever you put the device on the charging pad, it should latch into place and the device will automatically power on. The LED will turn off and the device will announce, β€œYour device is now charging.” Note: If you have allowed the battery to completely drain, it may take a few minutes for the device to power on. When the device has adequate battery charge and is also connected to the cellular network, it will announce, β€œYour device is now ready.” This indicates that your device is ready to make an emergency call. However, you should leave your device on the charging pad until the LED is off, indicating that your device has completed charging. Anelto Confidential 5 A complete charge will take approximately 2-3 hours. When fully charged your device should work for at least two days before needing to be recharged. State Power LED/Signal LED Announcement What this means What you should do On Charger Solid Red / Blinking Green While Registering – Solid Green When Registered β€œYour device is now charging.” Device is connected to the charger Leave on charger until battery is charged and the Power LED is OFF On Charger Solid Red OR Off / Solid Green β€œYour device is now ready.” Your device is ready to make a call Press the button if you wish to make a call Off Charger Off / Blinking Green While Registering Your device has adequate charge and is looking for cellular connection Wait. If this continues move to another location with better cell coverage Off Charger Blinking Red / Blinking Green While Registering – Solid Green When Registered β€œYour device battery is low. For your protection, please place your device on the charger now.” Your battery is critically low Place device on charger as soon as possible Anelto Confidential 6 Checking Device Registration Status: HELP Button Action Announcement What this means What you should do To check the device registration status, press quickly (less than 1 second) The Signal LED will display the registration status for 30 seconds Signal LED Results Announcement What this means What you should do After the quick press (less than 1 second) The Signal LED will blink green while attempting to register and will be solid green when successfully registered Anelto Confidential 7 Placing an Emergency Call: HELP Button Action Announcement What this means What you should do To place a call, press and hold fo…

Text truncated - open the document above for the full version.

External Photos

External Photos

ID Label/Location Info

ADDRESS 6270 Morningstar Drive The Colony, TX 75056 PHONE 972-939-9200 EMAIL [email protected] WEB anelto.com October 31, 2022 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR FCC ID Label Exemption- FCC FCC ID: 2AGPI-ANH0822 The purpose of this letter is to clarify the reasons for FCC ID label exemption on 2AGPI- ANH0822. Considered one of the smallest LTE Cat M devices in the industry, placing a legible FCC ID on the ANH0822 is not practical and impossible. The only area for the FCC ID together with IC ID is limited to 10mm x 25mm as shown below. Placing an aluminum printed, non- removal label can also interfere with the wireless charging operation internal the device. ADDRESS 6270 Morningstar Drive The Colony, TX 75056 PHONE 972-939-9200 EMAIL info@anelto.,com WEB anelto.com To this end, we proposed the FCC ID: 2AGPI-ANH0822 be printed on the User Guide on page 10 with font size of 18 as shown.

Internal Photos

ADDRESS 6270 Morningstar Drive The Colony, TX 75056 PHONE 972-939-9200 EMAIL [email protected] WEB anelto.com This picture shows the top PCA for ANH0822 This picture shows the bottom PCA for ANH0822 ADDRESS 6270 Morningstar Drive The Colony, TX 75056 PHONE 972-939-9200 EMAIL [email protected] WEB anelto.com This picture shows the internal of ANH0822

RF Exposure Info

Β© 2022 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 802 N. Twin Oaks Valley Road, Suite 105 β€’ San Marcos, CA 92069 β€’ U.S.A. TEL (760) 471-2100 β€’ FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Anelto Inc. Dates of Test: September 29-October 3, 2020 6270 Morning Star Drive Test Report Number: SAR.20221001 The Colony, TX 75056 Lab Designation Number: US1195 This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in IEEE 1528- 2013 and IEC 62209-1528:2020 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Testing Cert. # 2387.01 FCC ID: 2AGPI-ANH0822 IC Certificate: 20951-ANH0822 HVIN/Model(s): 2AGPI-ANH0822 Contains: FCC ID: XMR201912BG77 IC: 10224A-201912BG77 Test Sample: Engineering Unit Same as Production Serial Number: Eng 1 Equipment Type: Wireless mPERS Classification: Portable Transmitter In Front of Face and Next to Body TX Frequency Range: 699 – 716 MHz, 777 – 787 MHz, 1710 – 1755 MHz, 1850 – 1910 MHz Frequency Tolerance: Β± 2.5 ppm Maximum RF Output: 750 MHz (LTE) – 22.0 dBm, 1750 MHz (LTE) – 22.0 dBm, 1900 MHz (LTE) – 22.0 dBm Conducted Signal Modulation: QPSK, 16QAM Antenna Type: Internal Antenna Application Type: Certification FCC Rule Parts: Part 2, 22, 24, 27 KDB Test Methodology: KDB 447498 D01 v06, KDB 941225 D01 v03r01 Industry Canada: RSS-102 Issue 5, Safety Code 6 Max. Stand Alone SAR Value: 0.85 W/kg Reported Separation Distance: 0 mm Report Number: SAR.20221001 Β© 2022 RF Exposure Lab, LLC Page 2 of 86 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ................................................................................................................................................ 4 SAR Definition [5] .......................................................................................................................................... 5 2. SAR Measurement Setup .......................................................................................................................... 6 Robotic System ............................................................................................................................................. 6 System Hardware .......................................................................................................................................... 6 System Electronics ........................................................................................................................................ 7 Probe Measurement System ......................................................................................................................... 7 3. Probe and Dipole Calibration ................................................................................................................... 14 4. Phantom & Simulating Tissue Specifications ........................................................................................... 15 Head & Body Simulating Mixture Characterization ....................................................................................... 15 5. ANSI/IEEE C95.1 – 1992 RF Exposure Limits [2] .................................................................................... 16 Uncontrolled Environment ............................................................................................................................ 16 Controlled Environment ............................................................................................................................... 16 6. Measurement Uncertainty ........................................................................................................................ 17 7. System Validation .................................................................................................................................... 18 Tissue Verification ....................................................................................................................................... 18 Test System Verification .............................................................................................................................. 18 8. LTE Document Checklist ......................................................................................................................... 19 9. SAR Test Data Summary ......................................................................................................................... 22 Procedures Used To Establish Test Signal .................................................................................................. 22 Device Test Condition .................................................................................................................................. 22 10. SAR Test Results ................................................................................................................................. 27 11. Test Equipment List ............................................................................................................................. 29 12. Conclusion .................................................…

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201912BG77 Product LTE Cat M1 & Cat NB2 Module Brand Quectel Marketing Quectel BG77 Model BG77 Report No. R1909A0576-R3 Issue Date March 17, 2020 TA Technology (Shanghai) Co., Ltd.tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2019)/ FCC CFR47 Part 27C (2019). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.:R1909A0576-R3 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 2 of 84 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1 Test Laboratory ............................................................................................................................ 4 1.1 Notes of the Test Report ......................................................................................................... 4 1.2. Test facility ............................................................................................................................ 4 1.3 Testing Location ...................................................................................................................... 4 2 General Description of Equipment under Test .......................................................................... 5 2.1 Applicant and ManufacturerInformation .................................................................................. 5 2.2 Generalinformation .................................................................................................................. 5 3 Applied Standards ........................................................................................................................ 7 4 Test Configuration ........................................................................................................................ 8 5 Test Case Results ....................................................................................................................... 10 5.1 RF Power Output and Effective Isotropic Radiated Power .................................................... 10 5.2 Occupied Bandwidth ............................................................................................................. 15 5.3 Band Edge Compliance ........................................................................................................ 36 5.4 Peak-to-Average Power Ratio (PAPR) .................................................................................. 54 5.5 Frequency Stability ................................................................................................................ 56 5.6 Spurious Emissions at Antenna Terminals ............................................................................ 64 5.7 Radiates Spurious Emission ................................................................................................. 72 6 Main Test Instruments ................................................................................................................ 84 RF Test Report Report No.:R1909A0576-R3 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 3 of 84 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of Measurement Results Number Test Case Clause in FCC rules Verdict 1 RF Power Output andEffective Isotropic RadiatedPower 2.1046 27.50(d)(4) /27.50(b)(10) /27.50(c)(10) PASS 2 Occupied Bandwidth 2.1049 PASS 3 Band Edge Compliance 27.53(h) /27.53(g) /27.53(f) /27.53(c) PASS 4 Peak-to-Average Power Ratio 27.50(d)/KDB971168 D01(5.7) PASS 5 Frequency Stability 2.1055 / 27.54 PASS 6 Spurious Emissions at Antenna Terminals 2.1051 /27.53(h) /27.53(g) /27.53(f) /27.53(c) PASS 7 Radiates Spurious Emission 2.1053 /27.53(h) /27.53(g) /27.53(m) /27.53(f) /27.53(c) PASS Date of Testing:November 28, 2019~ February 20, 2020 Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. RF Test Report Report No.:R1909A0576-R3 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 4 of 84 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. A2LA(Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. 1.3 Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China City: Shangh…

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201912BG77 Product LTE Cat M1 & Cat NB2 Module Brand Quectel Model BG77 Marketing Quectel BG77 Report No. R1909A0576-R7 Issue Date March 17, 2020 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2019)/ FCC CFR47 Part 27C (2019). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.: R1909A0576-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 2 of 98 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1 Test Laboratory ............................................................................................................................ 4 1.1 Notes of the Test Report ......................................................................................................... 4 1.2. Test facility ............................................................................................................................ 4 1.3 Testing Location ...................................................................................................................... 4 2 General Description of Equipment under Test .......................................................................... 5 2.1 Applicant and Manufacturer Information.................................................................................. 5 2.2 General information ................................................................................................................. 5 3 Applied Standards ........................................................................................................................ 7 4 Test Configuration ........................................................................................................................ 8 5 Test Case Results ....................................................................................................................... 10 5.1 RF Power Output and Effective Radiated Power .................................................................. 10 5.2 Occupied Bandwidth ............................................................................................................. 17 5.3 Band Edge Compliance ........................................................................................................ 27 5.4 Peak-to-Average Power Ratio (PAPR) .................................................................................. 58 5.5 Frequency Stability ................................................................................................................ 61 5.6 Spurious Emissions at Antenna Terminals ............................................................................ 65 5.7 Radiates Spurious Emission ................................................................................................. 87 6 Main Test Instruments ................................................................................................................ 98 RF Test Report Report No.: R1909A0576-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 3 of 98 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of Measurement Results Number Test Case Clause in FCC rules Verdict 1 RF power output and Effective Radiated Power 2.1046 27.50(d)(4)/27.50(b)(10)/27.50(c)(10) PASS 2 Occupied Bandwidth 2.1049 PASS 3 Band Edge Compliance 27.53(h)/27.53(g)/27.53(f) /27.53(c) PASS 4 Peak-to-Average Power Ratio 27.50(d)/KDB971168 D01(5.7) PASS 5 Frequency Stability 2.1055 / 27.54 PASS 6 Spurious Emissions at Antenna Terminals 2.1051 /27.53(h)/27.53(g) /27.53(f) /27.53(c) PASS 7 Radiates Spurious Emission 2.1053 /27.53(h) /27.53(g) /27.53(f) /27.53(c) PASS Date of Testing: December 13, 2019 ~January 14, 2020 Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. RF Test Report Report No.: R1909A0576-R7 TA Technology (Shanghai) Co., Ltd. TA-MB-05-003R Page 4 of 98 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement. 1.3 Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China City: Shanghai Post code:…

Text truncated - open the document above for the full version.

Test Report

RF TEST REPORT Applicant Quectel Wireless Solutions Co., Ltd FCC ID XMR201912BG77 Product LTE Cat M1 & Cat NB2 Module Brand Quectel Model BG77 Marketing Quectel BG77 Report No. R1909A0576-R6 Issue Date March 13, 2020 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 2 (2019)/ FCC CFR 47 Part 24E (2019). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Performed by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 RF Test Report Report No.: R1909A0576-R6 TA Technology (Shanghai) Co., Ltd. TA-MB-05-002R Page 2 of 61 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ...................................................................................................................................... 4 1.1. Notes of the test report .................................................................................................................. 4 1.2. Testing Location ............................................................................................................................ 4 2. General Description of Equipment under Test ....................................................................................... 5 2.1. Applicant and Manufacturer Information ....................................................................................... 5 2.2. General information ....................................................................................................................... 5 3. Applied Standards .................................................................................................................................. 6 4. Test Configuration .................................................................................................................................. 7 5. Test Case Results .................................................................................................................................. 8 5.1. RF Power Output and Effective Radiated Power .......................................................................... 8 5.2. Occupied Bandwidth ................................................................................................................... 13 5.3. Band Edge Compliance ............................................................................................................... 19 5.4. Peak-to-Average Power Ratio (PAPR) ....................................................................................... 36 5.5. Frequency Stability ...................................................................................................................... 38 5.6. Spurious Emissions at Antenna Terminals ................................................................................. 42 5.7. Radiates Spurious Emission ....................................................................................................... 55 6. Main Test Instruments ......................................................................................................................... 61 RF Test Report Report No.: R1909A0576-R6 TA Technology (Shanghai) Co., Ltd. TA-MB-05-002R Page 3 of 61 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of measurement results No. Test Case Clause in FCC rules Verdict 1 RF power output and Effective Radiated Power 2.1046 24.232(c) PASS 2 Occupied Bandwidth 2.1049 PASS 3 Band Edge Compliance 2.1051 /24.238(a) PASS 4 Peak-to-Average Power Ratio 24.232/KDB 971168 D01(5.7) PASS 5 Frequency Stability 2.1055 / 24.235 PASS 6 Spurious Emissions at Antenna Terminals 2.1051 / 24.238(a) PASS 7 Radiates Spurious Emission 2.1053 / 24.238(a) PASS Date of Testing: December 13, 2019 ~January 14, 2020 Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. RF Test Report Report No.: R1909A0576-R6 TA Technology (Shanghai) Co., Ltd. TA-MB-05-002R Page 4 of 61 This report shall not be reproduced except in full…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Scott Constien(Executive VP)
[email protected]972-939-9200Fax: 972-394-1000

Test Firm

Eurofins TA Technology (Shanghai) Co., Ltd.Mr. Zhihui Liu
[email protected]86-21-50791141

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1227699.2 MHz - 715.8 MHz143.00 mW184KG7D0.00953 ppm
Confidentiality
Long Term
Grant Notes
Output power is conducted. The highest SAR level is 0.85 W/kg.