
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2.Double click TF/wireless mode conversion;button .Default is full brightness ; .Tap“M”button once dim light one level; .Tap“M”button second time and lights dims more than level one dim; .Tap“M”Third time and lights turns off; 6. Wireless status prompt blue LED. Wireless speaker+candle light manual FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna. ·Increase the separation between the equipment and receiver. ·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ·Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Page 1 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 1 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L3.5cm x 3.5cm) Label Location Candle light Bluetooth Speaker Model: Chillex FCC ID: 2AGSC-CHILLEX This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation.
Page 1 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna Page 4 of 4 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 3 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2AGSC-CHILLEX Product name : Candle light Bluetooth Speaker Test Model : Chillex Power Supply : Input: DC 5V, 1A DC 3.7V by Rechargeable Li-ion Battery, 200mAh Hardware Version : 1.0 Software Version : / Frequency Range : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : PCB Antenna Antenna Gain : -0.58dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Page 2 of 3 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.85 19 2440 1.3 39 2480 1.32 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 1.0 1.0 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f (GHz) Antenna Distance (mm) RF out…
Text truncated - open the document above for the full version.
Page 1 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT LE (Conducted Measurement) Product Name: Candle light Bluetooth Speaker Test Model: Chillex Environmental Conditions Temperature: 23.5 C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.699 0.5 Pass NVNT BLE 1M 2440 Ant1 0.706 0.5 Pass NVNT BLE 1M 2480 Ant1 0.705 0.5 Pass Page 3 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.85 30 Pass NVNT BLE 1M 2440 Ant1 1.3 30 Pass NVNT BLE 1M 2480 Ant1 1.32 30 Pass Page 6 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 8 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -14.28 8 Pass NVNT BLE 1M 2440 Ant1 -13.87 8 Pass NVNT BLE 1M 2480 Ant1 -13.6 8 Pass Page 9 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 10 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 1M 2480MHz Ant1 Page 11 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 1M 2402 Ant1 -57.19 -20 Pass NVNT BLE 1M 2480 Ant1 -58.18 -20 Pass Page 12 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 1M 2402MHz Ant1 Ref Band Edge NVNT BLE 1M 2402MHz Ant1 Emission Page 13 of 23 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Sh…
Text truncated - open the document above for the full version.
Page 1 of 34 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For SHENZHEN MGITEC CO.,LTD. Candle light Bluetooth Speaker Test Model: Chillex Additional Model No.: Please Refer to Page 6 Prepared for : SHENZHEN MGITEC CO.,LTD. Address : Room 305, building C, lingguo suo hengmingzhu industrial park, taoyuan community, xixiangstreet, baoan district, shenzhen Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 13, 2022 Number of tested samples : 2 Sample No. : A051122122-1, A051122122-2 Serial number : Prototype Date of Test : May 13, 2022 ~ May 17, 2022 Date of Report : May 18, 2022 Page 2 of 34 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA051122122EA Date of Issue .................................. : May 18, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : SHENZHEN MGITEC CO.,LTD. Address .......................................... : Room 305, building C, lingguo suo hengmingzhu industrial park, taoyuan community, xixiangstreet, baoan district, shenzhen Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Candle light Bluetooth Speaker Trade Mark ..................................... : N/A Test Model ...................................... : Chillex Ratings ........................................... : Input: DC 5V, 1A DC 3.7V by Rechargeable Li-ion Battery, 200mAh Result ............................................ : Positive Compiled by: Supervised by: Approved by: Vera Deng/ Administrator Jin Wang/ Technique principal Gavin Liang/ Manager Page 3 of 34 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : Chillex EUT......................................... : Candle light Bluetooth Speaker Applicant............................... : SHENZHEN MGITEC CO.,LTD. Address.................................. : Room 305, building C, lingguo suo hengmingzhu industrial park, taoyuan community, xixiangstreet, baoan district, shenzhen Telephone............................... : / Fax.......................................... : / Manufacturer........................ : SHENZHEN MGITEC CO.,LTD. Address................................... : Room 305, building C, lingguo suo hengmingzhu industrial park, taoyuan community, xixiangstreet, baoan district, shenzhen Telephone............................... : / Fax.......................................... : / Factory................................... : SHENZHEN MGITEC CO.,LTD. Address................................... : Room 305, building C, lingguo suo hengmingzhu industrial park, taoyuan community, xixiangstreet, baoan district, shenzhen Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA051122122EA May 18, 2022 Date of issue Page 4 of 34 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 18, 2022 Initial Issue -- Page 5 of 34 FCC ID: 2AGSC-CHILLEX Report No.: LCSA051122122EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2AGSC-CHILLEX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photo(s) of Conducted Emissions Measurement Fig. 4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.40 mW |

MAGLEV SPEAKER
Equipment Class
DTS - Digital Transmission System