Technical Specifications
| # | Rule Parts | Frequency Range | Power Output |
|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 72.00 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 68.00 mW |
| 3 | 15E | 5.50 GHz - 5.72 GHz | 75.00 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 71.00 mW |
Grant NotesRF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.23 W/kg and 1.35 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.46 W/kg and 1.80 W/kg respectively.