Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
O P E R A T I N G I N S T R U C T I O N S flexLock Safety locking device Review version 2021-04-30 Described product fle xL ock Manufacturer SIC K AG Er win-Sick-Str. 1 79183 Waldkirch Germany Legal information This w or k is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐ fication, abridgment or translation of this document is prohibited without the express written permission of SICK AG. The trademarks stated in this document are the property of their respective owner. © SICK AG. All rights reserved. Original document T his document is an or iginal document of SICK AG. 2 OPERATING INSTRUCTIONS | flexLock8020562/2021-04-30 | SICK Subject to change without notice Review version 2021-04-30 Contents 1 About this document........................................................................ 5 1.1 Scope......................................................................................................... 5 1.2 Target groups of these operating instructions........................................ 5 1.3 Additional information.............................................................................. 5 1.4 Symbols and document conventions...................................................... 5 2 Safety information............................................................................ 7 2.1 General safety notes................................................................................ 7 2.2 Intended use............................................................................................. 7 2.3 Improper use............................................................................................. 7 2.4 Requirements for the qualification of personnel.................................... 7 3 Product description........................................................................... 9 3.1 Design and function................................................................................. 9 3.2 Product characteristics............................................................................ 9 3.3 Manual unlocking..................................................................................... 11 4 Project planning................................................................................ 13 4.1 Manufacturer of the machine.................................................................. 13 4.2 Operator of the machine.......................................................................... 13 4.3 Design........................................................................................................ 13 4.4 Integration in the electrical control system............................................. 15 5 Mounting............................................................................................. 18 5.1 Safety......................................................................................................... 18 5.2 Orientation of the safety switch............................................................... 18 5.3 Mounting several safety switches............................................................ 18 5.4 Mounting the safety switch...................................................................... 19 5.5 Mounting the actuator.............................................................................. 19 6 Electrical installation........................................................................ 20 6.1 Safety......................................................................................................... 20 6.2 Notes on cULus......................................................................................... 21 6.3 Device connection.................................................................................... 21 6.4 Connection of a safe series connection.................................................. 22 7 Commissioning.................................................................................. 24 7.1 Teach-in..................................................................................................... 24 7.2 Testing....................................................................................................... 26 7.3 Regular thorough check........................................................................... 26 8 Operation............................................................................................ 28 8.1 Actuating the mechanical unlocking mechanism................................... 28 8.2 Preventing unintentional closing of the protective device..................... 28 CONTENTS 8020562/2021-04-30 | SICKOPERATING INSTRUCTIONS | flexLock 3 Subject to change without notice Review version 2021-04-30 9 Maintenance...................................................................................... 29 9.1 Cleaning..................................................................................................... 29 10 Troubleshooting................................................................................. 30 10.1 Safety......................................................................................................... 30 10.2 LED indicators........................................................................................... 30 11 Decommissioning............................................................................. 34 11.1 Disposal..................................................................................................... 34 12 Technical data.................................................................................... 35 12.1 Data sheet................................................................................................. 35 12.2 Connecting cables.................................................................................... 37 …
Text truncated - open the document above for the full version.
FCC TCB - Agency Authorization Letter_SICK_V1.docx/2021-05-20 1/1 19/05/2021 TÜV SÜD PSB Pte Ltd 15 International Business Park TÜV SÜD @ IBP Singapore 609937 To Whom It May Concern, Agency Authorization Letter The undersigned SICK AG, Erwin-Sick-Str. 1 79183 Waldkirch Germany, hereby authorize Mr. Peter Zhang, Mrs. Tan Swee Yin, Mrs. Jenny Teh and Mr. Raymond Chak, TÜV SÜD PSB Pte Ltd, 15 International Business Park, Singapore 609937 to act on our behalf in all matters relating to all processes required in FCC equipment authorization for FCC ID:2AHDRFXL1. Any and all acts carried out by TÜV SÜD PSB Pte Ltd, 15 International Business Park, Singapore 609937, on our behalf shall have the same effects as acts of our own, where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with SICK AG, Erwin-Sick-Str. 1 79183 Waldkirch Germany. We certify that we are not subject to denial of federal benefits that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Yours Sincerely, Name : Pavel Gerasimov Signature : Title/Position : Product Manager Email : [email protected]
FCC TCB - Confidential Request Letter_SICK_V1.docx/2021-05-20 1/1 19/05/2021 TÜV SÜD PSB Pte Ltd 15 International Business Park TÜV SÜD @ IBP Singapore 609937 To Whom It May Concern, Confidentiality Request for FCC ID: 2AHDRFXL1; FLEXLOCK SYSTEM, FXL1-SPLMSA00 (SENSOR) FXL1-AF1 (ACTUATOR) In accordance with the Sections 0.457 (d) (1) (ii) and 0.459 of the FCC Regulations, we request permanent confidentiality for the below indicated exhibits. (a) Schematic diagrams (b) Detailed block diagrams (c) Detailed operational descriptions (d) Bill of materials (e) Internal photos (f) Test set-up photos These documents contain detailed system descriptions and related information about the product which SICK AG considers proprietary, confidential and would otherwise not release to the general public. Disclosure of this information would benefit SICK AG’s competitors and provide unfair advantage in the market. We also hereby request [up to 180 days] short-term confidentiality for the following exhibits, (a) External photos Please contact me if there is any information you may need. Yours Sincerely, Name : Pavel Gerasimov Signature : Title/Position : Product Manager Email : [email protected]
Page 18 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 18 of25 EUT PHOTOGRAPHS Front View Rear View
DateCreatedDateReleas ed TEMPLATE F.LASER PRINTING 23/10/2020roslanu TEMPLATE F.LASER P RINTING Type: FXL1 Ident No: 9331168 ECNDateNameSingapore 757438Repl. for:Repl. by:Sh. 1 / 13 2 02 V e r v i e l f ä l t i g u n g d i e s e r U n t e r l a g e s o w i e V e r w e r t u n g u n d M i t t e i l u n g i h r e s I n h a l t e s ist unzulässig, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen sind strafbar und verpflichten zu Schadenersatz (LitUrhG, UWG, BGB). Alle Rechte fürden Fall der Patenterteilung oder GM-Eintragung vorbehalten. Template for Laser Printing for SENTRY SENTRY CORE (PTR), Sensor Left
LA-2007-0380-A LA-2007-0381-F LA-2007-0382-B LA-2007-0383-G LA-2007-0384-G LA-2007-0385-E LA-2007-0386-C LA-2010-0464-D LA-2018-0702-B LA-2018-0703-G LA-2020-0747-L The results reported herein have been performed in accordance with the terms of accreditation under the Singapore Accreditation Council. Inspections/Calibrations/Tests marked "Not SAC- SINGLAS Accredited" in this Report are not included in the SAC-SINGLAS Accreditation Schedule for our inspection body/laboratory. Laboratory: TÜV SÜDPSB Pte. Ltd. 15 International Business Park TÜV SÜD @ IBP Singapore 609937 Phone : +65-6778 7777 E-mail: [email protected] https://www.tuvsud.com/sg Co. Reg : 199002667R Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 15 International Business Park TÜV SÜD @ IBP Singapore 609937 Page 1 of25 TÜV SÜD PSB PTE LTD RESPONSIBLE FORNAMEDATESIGNATURE Project ManagementFoo Kai Maun09 Apr 2021 Authorised SignatoryQuek Keng Huat10 Mar 2021 Signatures in this approval box have checked this document in line with the requirements ofTÜV SÜD PSBdocument control rules. EXECUTIVE SUMMARY A sample of this product was tested and found to be compliant with the mentioned standard(s). Report on the Radio Testing of: FLEXLOCK SYSTEM Model(s): FXL1-SPLMSA00 (SENSOR) FXL1-AF1 (ACTUATOR) In accordance with 47 CFR FCC Part 15C Prepared for: SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany COMMERCIAL-IN-CONFIDENCE Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 2 of25 Contents 1Report Summary ..................................................................................................................... 3 1.1Report Modification Record ....................................................................................................... 3 1.2Introduction ............................................................................................................................... 4 1.3Brief Summary of Results .......................................................................................................... 6 1.4Product Information ................................................................................................................... 8 1.5Deviations from the Standard .................................................................................................... 9 1.6EUT Modification Record ........................................................................................................... 9 1.7Test Location(s) ........................................................................................................................ 9 1.8Test Facilities Registrations ..................................................................................................... 10 1.9Supporting Equipment ............................................................................................................. 11 2Test Details ............................................................................................................................ 12 2.1Radiated Emissions (Spurious Emissions Inclusive Restricted Bands Requirement) ................ 12 3Photographs .......................................................................................................................... 16 4Test Equipment ..................................................................................................................... 21 5Measurement Uncertainty ..................................................................................................... 22 6Annex A FCC Label and Position ...................................................................................... 23 End of the Test Report ......................................................................................................................... 25 Page 3 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 3 of25 1Report Summary 1.1Report Modification Record Alterations and additions to this report will be issued to the holders of each copy in the form of a complete document. IssueDescription of ChangeDate of Issue 1First Issue09 Apr 2021 Page 4 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 4 of25 1.2Introduction Applicant : SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany Manufacturer:Sick Product Center Asia Pte. Ltd. 8 Admiralty Street #04-11, Admirax Singapore 757438 Factory:SICK Sdn. Bhd. No. 16, Jalan Indah Gemilang 5 Taman Perindustrian Gemilang 81800, Ulu Tiram, Johor, Malaysia Model Number(s): Sensors 1. FXL1-SPLMSA00 (Tested) 2. FXL1-SPBUSA00 (Declared) 3. FXL1-SPBMSA00 (Declared) 4. FXL1-SPLUAA00 (Declared) 5. FXL1-SPLMAA00 (Declared) 6. FXL1-SPBUSA00 (Declared) Actuators 1. FXL1-AF1 (Tested) 2. FXL1-AR1 (Declared) Serial Number(s): 110323 Number of Samples Tested: 1 Test Sample(s) Condition:Good Quotation Reference:5373705 Test Specification/Issue/Date:FCC 47 CFR Part 15C Test Sample(s) Received Date:18 Feb 2021 Page 5 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 5 of25 Start of Test:18 Feb 2021 Finish of Test:22 Mar 2021 Page 6 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 6 of25 1.3Brief Summary of Results A brief summary of the tests carried out in accordance with specifications as shown below. Specification ClauseTest DescriptionResultComments/Base Standard 47 CFR FCC Part 15 15.107(a), 15.207Conducted EmissionsNot Applicable * See Note 3 ANSI C63.4: 2014 ANSI C63.10: 2013 15.109(a), 15.205, 15.209 Radiated Emissions (Spurious Emissions inclusive Restricted Bands Requirement) Pass ANSI C63.4: 2014 ANSI C63.10: 2013 15.215(c)Spectrum BandwidthNot Applicable * See …
Text truncated - open the document above for the full version.
Page 16 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 16 of25 3Photographs TEST SETUP (9kHz 30MHz) Radiated Emissions (Spurious Emissions Inclusive Restricted Bands Requirement) Test Setup (Front View) Radiated Emissions (Spurious Emissions Inclusive Restricted Bands Requirement) Test Setup (Rear View) Page 17 of 25 Document Number: 7191249437-EEC20/04 | Issue: 01 FCC ID: 2AHDRFXL1 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCEPage 17 of25 TEST SETUP (30MHz to 1GHz) Radiated Emissions (Spurious Emissions Inclusive Restricted Bands Requirement) Test Setup (Front View) Radiated Emissions (Spurious Emissions Inclusive Restricted Bands Requirement) Test Setup (Rear View)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |