2AHHJ-ZP-OXTAG1RTLS mobile

ZIGPOS GmbH
RTLS mobile - FCC ID 2AHHJ-ZP-OXTAG1 - ZIGPOS GmbH
Click to zoom

Application Details

Equipment Class
UWB - Ultra Wideband Transmitter
Date of Grant
Jul 11, 2024
Application Purpose
Original Equipment
Date of Application
Jun 25, 2024
Equipment Note
RTLS mobile
Frequency Range
7703.00000000 - 8254.00000000
Company
ZIGPOS GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CorivaTag Plus User Manual English CORIVA Real Time Locating System CorivaTag Plus User Manual 6/3/2024 CORIVA REAL TIME LOCATING SYSTEM User Manual  ZIGPOS GmbH Räcknitzhöhe 35A 01217 Dresden / Germany Phone +49 351 64750085 Version Status Date Author Modifications 2023.2 Draft 02.05.2023 Paul Balzer Initial 2023.2 Version 2023.2 Release 31.05.2023 Silvio Reuß Add power spectral density 2023.3 Release 21.08.2023 Paul Balzer Add Wireless Charging Pad & Helpdesk 2023.4 Release 05.02.2024 Paul Balzer, Silvio Reuß Add movement based ranging, updated System Overview, Change Documentation URL 2024.1 Release 17.04.2024 Silvio Reuß Update Compliance Information (RF Exposure Notice), Label, Technical data and Conformity Table of Contents LEGAL NOTICE 2 COPYRIGHT 2 PROPRIETARY STATEMENT / USE 2 PRODUCT IMPROVEMENTS 2 LIABILITY DISCLAIMER 2 LIMITATION OF LIABILITY 2 SAFETY AND COMPLIANCE INFORMATION 3 OVERHEATING 3 MECHANICAL IMPACTS 3 BATTERY DEEP DISCHARGE 3 EXPLOSIVE ENVIRONMENT 3 RADIO INTERFERENCE 3 COMPLIANCE INFORMATION 4 RF EXPOSURE NOTICE 5 SYSTEM OVERVIEW 6 SCOPE OF DELIVERY 7 PACKAGE LIST 7 INSTALLATION 8 PROJECT PLANNING 8 ATTACHMENT AND MOUNTING CLIP 8 OPERATION 9 OPTICAL STATUS 9 BUTTON 9 POWER SUPPLY / CHARGING 10 VIBRATION ACTUATOR 11 SOUND ACTUATOR 11 ACCELERATION SENSOR 11 NAMEPLATE 11 TECHNICAL DATA 13 RADIO SYSTEMS AND ENVIRONMENT 14 RADIATION PATTERN 14 DIMENSIONS 15 CLEANING 16 DISPOSAL 16 CONFORMITY 16 ASK FOR SUPPORT 16 C O R I V A T A G P L U S U S E R M A N U A L 1 CorivaTag Plus Welcome to the technical data sheet for our Ultra-Wideband (UWB) Tag, the mobile device of our Coriva Real-Time Location System (RTLS). The CorivaTag Plus is designed to send UWB signals to CorivaSats or other 3 rd party “omlox air 8”-certified RTLS Satellites. CorivaTag Plus is a cutting-edge Ultra-Wideband (UWB) device that is designed for highly accurate and reliable asset tracking. Equipped with advanced Ultra-Wideband technology, this compact and versatile device is capable of providing real-time location data with a high update rate of up to 4Hz, ensuring that you always have access to the most up-to-date position information about your assets. omlox is the world's first open locating standard which aims to implement flexible real-time locating solutions with elements from various manufacturers. For more information about omlox, please visit omlox.com. One of the most innovative features of the CorivaTag Plus is its wireless rechargeability, which eliminates the need for cumbersome cables and connectors and the utilization of an acceleration sensor to detect movement. The CorivaTag Plus is specifically designed for industrial use, and as such, it is built to be robust, shock-resistant, and waterproof with an IP67 rating. This means that it can withstand harsh environmental conditions, making it a reliable asset tracking solution for use in challenging settings. Figure 1 – CorivaTag Plus C O R I V A T A G P L U S U S E R M A N U A L 2 Legal Notice Copyright The copyrights in this user guide and the system described therein are owned by the company ZIGPOS GmbH (hereafter also referred as "ZIGPOS"). ZIGPOS and ZIGPOS logo are registered trademarks. All other brand names, product names, or trademarks belong to their respective holders. ZIGPOS GmbH, Räcknitzhöhe 35a, 01217 Dresden. Contact information: see back cover. Proprietary Statement / Use This document contains proprietary information of ZIGPOS which may not be used, reproduced, or disclosed to any other parties for any other purpose without the express, written permission of ZIGPOS. This document has been made available as part of the license that has been granted to an authorized user of ZIGPOS software. It is intended solely for the information and use of parties operating and maintaining the equipment described herein. Use of this documentation is subject to the terms and limitations of that license agreement. This document describes all the functionality that can be licensed for this product. Not all functionality described in this document may be available to you depending on your license agreement. If you are not aware of the relevant terms of your license agreement, please contact Sales at ZIGPOS. Product Improvements The continuous improvement of products is a policy of ZIGPOS. All specifications and designs are subject to change without notice. Liability Disclaimer ZIGPOS takes steps to ensure that its published documentation is correct; however, errors do occur. We reserve the right to correct any such errors and dis claims any liability resulting from them. Limitation of Liability In no event shall ZIGPOS, any of its licensors or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any of the following (collectively referred to as "injuries"): injuries (including death) or damages to persons or to property, or damages of any other kind, direct, indirect, special, exemplary, incidental or consequential, including, but not limited to, loss of use, lost profits, lost revenues, loss of data, business interruption, replacement costs, debt service or rental payments, or damages owing by you to others, whether arising out of contract, tort, strict liability or otherwise, arising from or relating to the design, use (or inability to use) or operation of these materials, the software, documentation, hardware, or from any services provided by ZIGPOS (whether or not ZIGPOS or its licensors knew or should have known of the possibility of any such injuries) even if a remedy set forth herein is found to have failed to fulfill its essential purpose. Some jurisdictions do not allow C O R I V A T A G P L U S U S E R M A N U A L 3 the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Safety and Compliance Information Overheating Excessive ambient temperatures and heat accumulation can caus…

Text truncated - open the document above for the full version.

Attestation Statements

ZIGPOS GmbH | Raecknitzhoehe 35a | 01217 Dresden | Germany ZIGPOS GmbH Raecknitzhoehe 35a 01217 Dresden Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA March 15, 2024 Attestation Statement according to 2.911(d)(7) FCC ID: 2AHHJ-ZP-OXTAG1 TO WHOM IT MAY CONCERN: We, ZIGPOS GmbH with FCC Registration Number (FRN) 0025317652 designate FCC US Agent, LLC, to act as U.S. agent for service of process. FCC US Agent, LLC, with FCC Registration Number (FRN) 0033402884 hereby acknowledges the obligation of the U.S. agent for service of process. Further ZIGPOS GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely _______________ (signature & company stamp) Company Name: ZIGPOS GmbH Address: Raecknitzhoehe 35a, 01217 Dresden, Germany Contact Person: Erik Mademann Phone: +49 351 6475-0084 Email: [email protected] _______________ (signature & company stamp) Company Name: FCC US Agent, LLC Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 2024-04-11 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b) (4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID: 2AHHJ-ZP-OXTAG1 Model name: CorivaTag Plus For the product stated above, we request that the following information be held confidential: Exhibits Long-Term Confidentiality Short-Term Confidentiality External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Description The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device, which is planned for 180 days. If you have any questions, please feel free to contact me at the address shown below. Sincerely, ______________________________ Name / Title: Erik Mademann, CEO Company: ZIGPOS GmbH Address: Raecknitzhoehe 35a 01217 Dresden Germany Phone: +49 351 6475-0084 Fax: +49 351 6475-0086 E-Mail: [email protected]

External Photos

frontside backside left side view right side view top view bottom view

External Photos

The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by cetecom advanced GmbH Annex 3: External photographs 22-1-0057101T027a-A3-C01 Number of pages: 5 Date of Report: 2024-Jun-13 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: ZIGPOS GmbH Product: RTLS mobile Model: CorivaTag Plus FCC ID: 2AHHJ-ZP-OXTAG1 IC: IC: 32087-ZPOXTAG1 Testing has been carried out in accordance with: FCC Regulations Title 47 CFR, Chapter I Subpart C Intentional Radiators § 15.247 Operation within the bands 2400-2483.5 MHz ISED-Regulations Radio Standards Specification RSS-Gen, Issue 5 General Requirements for Compliance of Radio Apparatus RSS-247, Issue 3 Digital Transmission Systems (DTSs) 22-1-0057101T027a-A3-C01 TR22-1-0057101T027a-A3-C01 2 / 5 External photographs (EUT/DUT) Fig. Ext.: 1 : Ext. - Front RTLS mobile Fig. Ext.: 2 : Ext. - Rear RTLS mobile 22-1-0057101T027a-A3-C01 TR22-1-0057101T027a-A3-C01 3 / 5 Fig. Ext.: 3 : Ext. - Front RTLS mobile Fig. Ext.: 4 : Ext. - Rear RTLS mobile 22-1-0057101T027a-A3-C01 TR22-1-0057101T027a-A3-C01 4 / 5 Fig. Ext.: 5 : Ext. - Front RTLS mobile Fig. Ext.: 6 : Ext. - Rear RTLS mobile 22-1-0057101T027a-A3-C01 TR22-1-0057101T027a-A3-C01 5 / 5 Fig. Ext.: 7 : Ext. - Front Laptop End Of Annex 3

ID Label/Location Info

Label Position CorivaTag Plus Frontside of Device Label Information CorivaTag Plus Back Label Front Label Full MAC address in QR code, last 4 digits written below

Internal Photos

inside front view inside back view with vibration motor inside back view without vibration motor inside back view with LiPo off charging coil behind black protective film

RF Exposure Info

© cetecom advanced GmbH Page 1 of 13 TEST REPORT Test report no.: 22-1-0057101T30_TR1-R01 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 ZIGPOS GmbH Räcknitzhöhe 35a 01217 Dresden GERMANY E-Mail: [email protected] Phone:+49 351 64750084 Manufacturer Kathrein Sachsen GmbH Lindenstraße 3 09241 Mühlau GERMANY Test Item Kind of test item: RTLS Tag Model name: CorivaTag Plus FCC ID: 2AHHJ-ZP-OXTAG1 IC ID: 32087-ZPOXTAG1 Frequency: 2.4 GHz, 7.7-8.3 GHz Technology tested: WPAN, UWB This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Martin Nunier Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 22-1-0057101T30_TR1-R01 © cetecom advanced GmbH Page 2 of 13 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 2.3 Structure of this Document ................................................................................................................... 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 1 mW Test Exemption ........................................................................................................................... 5 3.2 MPE-Based Test Exemption ................................................................................................................. 5 3.3 SAR-Based Test Exemption .................................................................................................................. 5 3.4 Simultaneous Transmission ............................................................................................................... 6 4 1 mW Test Exemption ...................................................................................................................................... 7 4.1 Detailed Description .............................................................................................................................. 7 4.2 Results ................................................................................................................................................... 7 5 MPE-Based Test Exemption ............................................................................................................................ 8 5.1 Detailed Description .............................................................................................................................. 8 5.2 Results ................................................................................................................................................... 9 6 SAR-Based Test Exemption ........................................................................................................................... 10 6.1 Detailed Description ............................................................................................................................ 10 6.2 Results ................................................................................................................................................. 11 7 Simultaneous Transmission .......................................................................................................................... 12 7.1 Detailed Description ............................................................................................................................ 12 7.2 Result................................................................................................................................................... 13 8 Conclusion ...................................................................................................................................................... 13 Test report no.: 22-1-0057101T30_TR1-R01 © cetecom advanced GmbH Page 3 of 13 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or incomplete product information pro…

Text truncated - open the document above for the full version.

Test Report

ZIGPOS GmbH CEOs Commerzbank AG Amtsgericht Dresden Räcknitzhöhe 35a Erik Mademann IBAN DE33850400000113351100 HRB 30129 01217 Dresden, Germany Christoph Götze BIC COBADEFF850 VAT-Id:. DE815285488 Antenna Report – CorivaTag Plus Date: 27/03/2024 Antenna development and original report by IRK – Dresden Contact: IRK - Dresden Nossener Str. 30 01723 Mohorn Germany Phone: +49 35209 29996 20 Fax: +49 35209 29996 17 Mail: [email protected] Web: https://www.irk-dresden.de/ ZIGPOS GmbH Räcknitzhöhe 35a 01217 Dresden, Germany P +49 351 6475-0084 F +49 351 6475-0086 [email protected] www.zigpos.com Antenna Report – CorivaTag Plus ZIGPOS GmbH 2 Content List of figures ........................................................................................................................................... 2 Preliminary clarification .......................................................................................................................... 3 Used software and devices...................................................................................................................... 3 1. Simulation model of the housing .................................................................................................... 3 2. UWB antenna .................................................................................................................................. 5 3. ISM / OOB antenna .......................................................................................................................... 6 4. Antenna integration ........................................................................................................................ 7 5. Design of prototype ......................................................................................................................... 7 6. Measurement of the matching ....................................................................................................... 8 7. Measurement of the emission ........................................................................................................ 9 List of figures figure 1 - initial model ............................................................................................................................. 3 figure 2 - simulation model ..................................................................................................................... 4 figure 3 - UWB antenna simulation model .............................................................................................. 5 figure 4 - UWB antenna: computed matching ........................................................................................ 5 figure 5 - UWB antenna: computed emission for UWB channel 9 in dBi ................................................ 5 figure 6 - OOB antenna simulation model ............................................................................................... 6 figure 7 - OOB antenna: computed matching ......................................................................................... 6 figure 8 - OOB antenna: computed emission @2.45Ghz in dBi .............................................................. 6 figure 9 - simulation layout of the interconnection as a mesh representation ...................................... 7 figure 10 - parts of prototype .................................................................................................................. 7 figure 11 - assembly ................................................................................................................................ 7 figure 12 - measured matching UWB antenna ........................................................................................ 8 figure 13 - measured matching OOB antenna ......................................................................................... 8 figure 14 - orientation of the diagrams and polarizations ...................................................................... 9 figure 15 - horizontal section UWB antenna ch9 @7.9872GHz .............................................................. 9 figure 16 - vertical section UWB antenna ch9 @7.9872GHz ................................................................. 10 figure 17 - horizontal section OOB antenna @2.45GHz ........................................................................ 10 figure 18 - vertical section OOB antenna @2.45GHz ............................................................................ 11 Antenna Report – CorivaTag Plus ZIGPOS GmbH 3 Preliminary clarification This antenna report uses parts of the original antenna report from IRK - Dresden. It is a translation of the original German version, with some irrelevant information omitted. Editor of original report: Dr. R. Klukas Publication date: 26/06/2022 Used software and devices Simulation software: Wipl-D CDA constrcution: VariCAD Network analyzator: Anritsu Wiltron 37347C 1. Simulation model of the housing figure 1 - initial model Antenna Report – CorivaTag Plus ZIGPOS GmbH 4 figure 2 - simulation model The housing data was supplied in .stp format. The data was processed and simplified in WIPL-CAD. Details not required for the calculations, such as lettering, small corners or edges, were removed. The individual parts were assembled in WIPL-D, material properties were assigned and the actual antenna structures were programmed parametrically. The housing (yellow) was assumed to be a PC material. The blue parts are rubber seals made of TPU material. The parts of the FR4 circuit board material are shown in magenta. Green parts are ideal electrically conductive surfaces. The screws, a vibration motor and the electronics board were included in the model. Antenna Report – CorivaTag Plus ZIGPOS GmbH 5 2. UWB antenna The UWB antenna was designed as a ring antenna over a base plate. The structure can be printed on the top and bottom of a printed circuit board and plated through at the edges.…

Text truncated - open the document above for the full version.

Test Report

Test Report 22-1-0057101T028a Number of pages: 29 Date of Report: 2024-Apr-04 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: ZIGPOS GmbH Product: RTLS mobile Model: CorivaTag Plus FCC ID: 2AHHJ-ZP-OXTAG1 IC: 32087-ZPOXTAG1 Testing has been carried out in accordance with: FCC Regulations Title 47 CFR, Chapter I, Subchapter A, Part 15 Subpart C Intentional Radiators § 15.207 Conducted limits Subpart F Ultra-Wideband Operation § 15.519 Technical requirements for hand held UWB systems § 15.521 Technical requirements applicable to all UWB devices ISED-Regulations Radio Standards Specifications RSS-Gen, Issue 5 General Requirements for Compliance of Radio Apparatus RSS-220, Issue 1 + Amendment 1 (July 2018) Devices Using Ultra-Wideband (UWB) Technology Tested Technology: UWB Test Results: ☒ The EUT complies with the requirements in respect of all parameters subject to the test. The test results relate only to devices specified in this document Signatures: B.Eng. Martin Nunier Dipl.-Ing. Christian Lorenz Supervisor Radio Services Lab Manager Authorization of test report Responsible of test report Test Report 22-1-0057101T028a TR22-1-0057101T028a 2 / 29 Table of Contents Table of Annex .................................................................................................................................................................................. 3 1 General information ................................................................................................................................................................ 4 1.1 Disclaimer and Notes ......................................................................................................................................................... 4 1.2 Attestation ......................................................................................................................................................................... 4 1.3 Summary of Test Results ................................................................................................................................................... 5 1.4 Summary of Test Methods ................................................................................................................................................ 5 2 Administrative Data ................................................................................................................................................................. 6 2.1 Identification of the Testing Laboratory ............................................................................................................................ 6 2.2 General limits for environmental conditions ..................................................................................................................... 6 2.3 Test Laboratories sub-contracted ...................................................................................................................................... 6 2.4 Organizational Items ......................................................................................................................................................... 6 2.5 Applicant’s details ............................................................................................................................................................. 6 2.6 Manufacturer’s details ...................................................................................................................................................... 6 2.7 Equipment under Test (EUT) ............................................................................................................................................. 7 2.8 Untested Variant (VAR) ..................................................................................................................................................... 7 2.9 Auxiliary Equipment (AE) ................................................................................................................................................... 7 2.10 Connected cables (CAB)..................................................................................................................................................... 7 2.11 Software (SW).................................................................................................................................................................... 8 2.12 EUT set-ups ........................................................................................................................................................................ 8 2.13 EUT operation modes ........................................................................................................................................................ 8 3 Equipment under test (EUT) .................................................................................................................................................... 9 3.1 General Data of Main EUT as Declared by Applicant ......................................................................................................... 9 3.2 Detailed Technical data of Main EUT as Declared by Applicant ........................................................................................ 9 3.3 Modifications on Test sample ........................................................................................................................................... 9 4 Measurements....................................................................................................................................................................... 10 4.1 Transmission time measurement .................................................................................................................................... 10 4.2 10 dB bandwidth measurement ........................................................................................…

Text truncated - open the document above for the full version.

Test Report

The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright: All rights reserved by cetecom advanced GmbH Annex 1: Measurement diagrams 22-1-0057101T028a-A1 Number of pages: 33 Date of Report: 2024-Apr-04 Testing company: cetecom advanced GmbH Untertuerkheimer Str. 6-10 66117 Saarbruecken GERMANY Applicant: ZIGPOS GmbH Product: RTLS mobile Model: CorivaTag Plus FCC ID: 2AHHJ-ZP-OXTAG1 IC: 32087-ZPOXTAG1 Testing has been carried out in accordance with: FCC Regulations Title 47 CFR, Chapter I, Subchapter A, Part 15 Subpart C Intentional Radiators § 15.207 Conducted limits Subpart F Ultra-Wideband Operation § 15.519 Technical requirements for hand held UWB systems § 15.521 Technical requirements applicable to all UWB devices ISED-Regulations Radio Standards Specifications RSS-Gen, Issue 5 General Requirements for Compliance of Radio Apparatus RSS-220, Issue 1 + Amendment 1 (July 2018) Devices Using Ultra-Wideband (UWB) Technology Test Report 22-1-0057101T028a-A1 TR22-1-0057101T028a_A1 2 / 33 1Measurement diagrams........................................................................................................................................................... 3 1.1Magnetic field strength ..................................................................................................................................................... 3 1.2Electric…

Text truncated - open the document above for the full version.

Contact Information

Applicant

EriK Mademann(Managing Director)
[email protected]00493516475Fax: 004935164750086

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]+49 681 598 0Fax: +49 681 598 8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115F7.70 GHz - 8.25 GHz-
Confidentiality
Long Term
Grant Notes
UWB tag device for a real-time locating system. Operation onboard an aircraft, a ship or a satellite is prohibited. The use of devices mounted on outdoor structures, e. g. Static Units mounted on the outside of a building or any fixed outdoor infrastructure is prohibited.