FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Infobionic, Inc./
  3. 2AHLC01858

2AHLC01858Charger Base

Infobionic, Inc.
Charger Base - FCC ID 2AHLC01858 - Infobionic, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 28, 2023
Application Purpose
Original Equipment
Date of Application
Nov 28, 2023
Equipment Note
Charger Base
Frequency Range
2402.00000000 - 2480.00000000
Company
Infobionic, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MoMe ® ARC Physician’s Guide #30815 rB InfoBionic, Inc. - 2 - MoMe ® Arc Physician’s Guide 30815 rB June 20, 2023 - 3 - Copyright, Technical Support, Trademark, and Contact Information Contact Information: InfoBionic, Inc. 312 Billerica Rd. Office Link #5 Chelmsford, MA 01824 USA Email: [email protected] Technical Support: 1 (844) 401-9725 8:00 a.m. – 8.00 p.m. EST Monday - Saturday 9:00 a.m. – 6:00 p.m. EST Sunday Email: [email protected] InfoBionic’s MoMe ® ARC System may be covered under one or more United States and International Patents. Please see the website: www.infobionic.com to satisfy the virtual patent marketing provisions including the America Invents Act and 35 U.S.C. § 287(a). Additional patents may be issued or pending in the US and elsewhere. © 2023 InfoBionic, Inc. and the MoMe ® ARC logo are registered trademarks of InfoBionic, Inc.  InfoBionic, Inc. - 4 - Table of Contents Chapter 1. Welcome to MoMe ® ARC ...................................................................................... 6 1.1 Features & Benefits ....................................................................................................... 6 1.2 MoMe® Arc Components .............................................................................................. 7 1.3 Indications ..................................................................................................................... 7 1.4 Contraindications ........................................................................................................... 7 1.5 Symbols......................................................................................................................... 8 1.6 Essential Performance .................................................................................................. 8 1.7 Cellular Coverage Considerations ................................................................................. 9 1.7.1 Device Indicators ........................................................................................................... 9 1.7.2 MoMe® Software Platform Indicators ............................................................................ 9 Chapter 2. Safety .................................................................................................................. 10 2.1 Warnings ..................................................................................................................... 10 2.2 Cautions ...................................................................................................................... 12 Chapter 3. Specifications and Components .......................................................................... 13 3.1 Specifications .............................................................................................................. 13 3.2 Components ................................................................................................................ 14 3.3 Service Life.................................................................................................................. 14 Chapter 4. Device Configuration, Patient Setup and Monitoring ........................................... 15 4.1 Device Configuration ................................................................................................... 15 4.2 Initial Patient Setup ..................................................................................................... 15 Step 1: Locate the kit components and ensure contents includes: ..................................... 15 Step 2: Prepare the Skin ..................................................................................................... 16 Step 3: Apply Gel Pads to Patient’s Chest and Connect Electrode Wires .......................... 16 Step 4: MoMe ® Arc System Activation and Baseline Recording ......................................... 16 4.3 Patient Monitoring ....................................................................................................... 17 4.4 Patient Reminders ....................................................................................................... 17 Chapter 5. Device Controls and User Interface..................................................................... 18 5.1 Event Record Button - Reporting Cardiac Symptoms ................................................. 18 5.2 Low Battery Alert ......................................................................................................... 19 5.3 Leads Off Alert ............................................................................................................ 20 5.4 Sensor Disconnected Alert .......................................................................................... 20 5.5 System Error ............................................................................................................... 21 5.6 Sensor Vibration .......................................................................................................... 21 5.7 LED Indicators ............................................................................................................. 21 5.8 Charging the MoMe® Arc Gateway and Sensor ......................................................... 22 Chapter 6. Service, Cleaning, and Disposal.......................................................................... 24 6.1 Service ........................................................................................................................ 24 6.2 Cleaning ...................................................................................................................... 24 6.3 Disposal of Waste ....................................................................................................... 24 6.4 Software Updates ........................................................................................................ 24 Chapter 7. Electromagnetic Emissions Compliance and…

Text truncated - open the document above for the full version.

Attestation Statements

321 Billerica Road OfficeLink #5 Chelmsford, MA 01824 www.infobionic.com Date: 6/19/2023 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: 2AHKC01856,2AHLC01857,2AHKC01858 1. InfoBionic Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. InfoBionic Inc(“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List . Sincerely yours, Name: David MacCutcheon Job Title: COO Company Name: InfoBionic. Inc.

Attestation Statements

321 Billerica Road OfficeLink #5 Chelmsford, MA 01824 www.infobionic.com Date: 6/19/2023 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation FCC ID: 2AHKC01856,2AHLC01857,2AHKC01858 To whom it may concern: InfoBionic, Inc (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. Dave MacCutcheon InfoBionic FCC FRN: 0025354739 321 Billerica Road OfficeLink #5 Chelmsford, MA 01824 [email protected] Sincerely yours, Dave MacCutcheon InfoBionic 321 Billerica Road OfficeLink #5 Chelmsford, MA 01824 [email protected]

Cover Letter(s)

321 Billerica Road Office Link #5 Chelmsford, MA 01824 www.infobionic.com Date: 4/3/2023 UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL LLC as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, David MacCutcheon, COO InfoBionic Inc.

Cover Letter(s)

321 Billerica Road OfficeLink #5 Chelmsford, MA 01824 www.infobionic.com Date: 11/21/2023 Attn: FCC Office of Engineering and Technology / UL Verification Services TCB Subject: Request for Confidentiality FCC ID: 2AHLC01856,2AHLC01857,2AHLC01858 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely.  Schematic Diagram  Operational Description and Block Diagram Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until November 30, 2023  External Photos  Internal Photos  Test Setup Photos  User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Dave MacCutcheon COO InfoBionic Inc

ID Label/Location Info

SCALE 1:1 MANUFACTURE NOTES: 3. ‘C’ DENOTES CHECKSUM TO BE CALCULATED PER ABOVE STANDARD. 2. SERIAL NUMBER STRING: *+B690MK20/$$+7CIA#####C* TO BE ENCODED IN 2D AZTEC BARCODE PER ANSI/HIBC 2.6 ‐ 2016 THE HEALTH INDUSTRY SUPPLIER LABELING STANDARD FOR PATIENT SAFETY & UNIQUE DEVICE IDENTIFICATION (UDI) . REVISIONS DCO#REV.DESCRIPTIONDATEAPPROVED TBD1INITIAL RELEASE 10/06/2021 D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 TITLE B REVPART NUMBERSIZESCALE 306RL-CHARGER REGULATORY LABEL DRAWING FILE NAME MODEL FILE NAME DO NOT SCALE DRAWING DIMENSIONS ARE IN MILLIMETERS TOLERANCES UNLESS OTHERWISE SPECIFIED: X.X 0.2 X.XX 0.13 ANGULAR: 1 6306RL-ART 1:1 SHEET 1 OF 1 INFOBIONIC CHARGER REGULATORY LABEL PROPRIETARY NOTICE: THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION OF INFOBIONIC. IT MUST NOT BE REPRODUCED, DISCLOSED, OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF ANY ITEM OTHER THAN THAT FOR WHICH IT WAS PROVIDED WITHOUT PRIOR WRITTEN PERMISSION OF INFOBIONIC. ALL RIGHTS RESERVED BY INFOBIONIC, COPYRIGHT (C) 306RL-CHARGER REGULATORY LABEL THIRD ANGLE PROJECTION 200 Fifth Avenue Suite 4030 Waltham, MA 02451 TBD2UPDATE COLORS10/20/2021 TBD3UPDATED READ MANUAL ICON 11/03/2022 TBD4UPDATED MFG ICON, PLACEHOLDER SERIAL NUMBER01/17/2023 TBD5UPDATED MFG LOCATION, REMOVED TYPE BF ICON03/14/2023 TBD6UPDATED FCC ID10/09/2023 4. MAGENTA LINE INDICATES PARTS OUTLINE ONLY - DO NOT PRINT. WhitePantone Cool Gray 9 C 1. SERIALIZATION REQUIRED IN TWO PLACES, ‘03127’ AND BARCODE SHOWN AS PLACEHOLDER RAL 5005 Signal Blue 5V, 2.4A, 12W Use only with supplied power adapter InfoBionic Chelmsford, MA, USA IP22 Read Manual First FCC ID: 2AHLC01858 *+B690MK20/$ $+7CIA03127C* CIA03127

RF Exposure Info

FCC Part 1 Subpart I FCC Part 2 Subpart J RF EXPOSURE REPORT FOR AMBULATORY ELECTROCARDIOGRAM CHARGING BASE MODEL NUMBER: MoMe ARC Charger FCC ID: 2AHLC01858 REPORT NUMBER: R14275554-E8 ISSUE DATE: 2023-10-03 Prepared for INFOBIONIC, INC 400 TOTTEN POND RD STE 315 WALTHAM, MA 02451, U.S.A. Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R14275554-E8 DATE: 2023-10-03 FCC ID: 2AHLC01858 Page 2 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REVISION HISTORY Rev. Issue Date Revisions Revised By V1 2023-10-03 Initial Issue Brian Kiewra REPORT NO: R14275554-E8 DATE: 2023-10-03 FCC ID: 2AHLC01858 Page 3 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REVISION HISTORY ..................................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................4 2. TEST METHODOLOGY ......................................................................................................5 3. REFERENCES ....................................................................................................................5 4. FACILITIES AND ACCREDITATION ..................................................................................5 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ...............................................6 5.1. METROLOGICAL TRACEABILITY ...............................................................................6 5.2. DECISION RULES ........................................................................................................6 5.3. MEASUREMENT UNCERTAINTY ................................................................................6 6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) ................................7 6.1. FCC RULES .................................................................................................................7 6.2. EQUATIONS .................................................................................................................8 7. RF EXPOSURE RESULTS ................................................................................................10 END OF TEST REPORT ..........................................................................................................10 REPORT NO: R14275554-E8 DATE: 2023-10-03 FCC ID: 2AHLC01858 Page 4 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: InfoBionic, Inc 400 Totten Pond Rd STE 315 Waltham, MA 02451, USA EUT DESCRIPTION: Ambulatory Electrocardiogram Charging Base MODEL: Kardia 3 Charger SERIAL NUMBER: MIB1033 SAMPLE RECEIPT DATE: 2022-08-15 DATE TESTED: 2022-08-30 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Complies UL LLC. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. All samples tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. This document may not be altered or revised in any way unless done so by UL LLC. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by a2La, NIST, or any agency of the U.S. government. Approved & Released For UL LLC By: Prepared By: Michael Antola Brian Kiewra Staff Engineer Project Engineer Consumer, Medical and IT Segment Consumer, Medical and IT Segment UL LLC UL LLC REPORT NO: R14275554-E8 DATE: 2023-10-03 FCC ID: 2AHLC01858 Page 5 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY All calculations were made in accordance with FCC Parts 1.1310, 2.1091, 2.1093, KDB 447498 D01 v06, KDB 447498 D03 V01, IEEE Std C95.1-2005, IEEE Std C95.3-2002. 3. REFERENCES Output power and antenna gain data is excerpted from product documentation provided by the applicant. 4. FACILITIES AND ACCREDITATION UL LLC is accredited by A2LA, certification # 0751.06, for all testing performed within the scope of this report. Testing was performed at the locations noted below. Address ISED CABID ISED Company Number FCC Registration ☐ Building: 12 Laboratory Dr RTP, NC 27709, U.S.A US0067 2180C 825374 ☒ Building: 2800 Perimeter Park Dr. Suite B Morrisville, NC 27560, U.S.A 27265 REPORT NO: R14275554-E8 DATE: 2023-10-03 FCC ID: 2AHLC01858 Page 6 of 10 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 5. DECISION RULES AND MEASUREMENT UNCERTAINTY 5.1. …

Text truncated - open the document above for the full version.

Test Report

LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 FeaturesApplications Electrical Specifications •2450MHz, Bandwidth ≥90MHz •Suitable for RoHS compliant reflow •Gain 0.5dBi (Peak) / -1dBi (Average) •VSWR <2:1 •Small size – 3.2 x 1.6 x 1.2mm (0.125 x 0.62 x 0.047 inch) •Non Ground Mounting type. •Power Handling 3W Max •Matched to 50 Ohm. •Wireless application - Bluetooth / WiFi (2.445GHz) •High density applications •Bluetooth headsets or ear pieces •Computer mouse and keyboards •PROFINET – Industrial automation •Video Game systems •Alternative to larger PCB solution ParameterMin.Typ.Max.UnitsNote Frequency2450MHz Bandwidth100MHz Peak Gain0.5dBi Average Gain-1dBi VSWR2 Impedance50Ω Power Capability3W Environmental Characteristics ParametersSpecification Environmental friendlyPb-free MSL1 Operating Temperature-40 ºC to + 85 ºC Storage Temperature-10 ºC to +40 ºC Relative Humidity70% LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Product Dimensions and PCB Land Drawing (Unit: mm) This is the feed-line to the Antenna and should be matched to 50 Ohms based upon the PCB dielectric parameters. SeriesABCDEFGH AMCA313.2±0.21.6±0.21.2±0.20.5±0.21.6±0.20.8±0.20.8±0.22.6±0.2 No.Terminal NameNo.Terminal Name Pad 1Feed PointPad 2NC Terminal Configurations LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Application Test Circuit & PCB layouts – Default Layouts Figure shows the PCB layout highlighting the Ground and No Ground areas and trace feed line to the chip antenna. Matching Circuit and Reference Values ComponentDescriptionValue AntennaAMCA31-2R450G-S1F-T3---- Capacitor *Series C0.5 ~ 10 pF *Shunt C33pF, 100 pF Inductor Series L1.0 ~ 6nH Shunt L1.0 ~ 6nH *Series: Connected between antenna and feeding line in series. *Shunt: Connected between antenna and feeding line in parallel Note: Recommendation is to pre-place the π-type circuit layout circuit which will offer full flexibility to match the antenna to 50 Ohm in the final product layout with one of the match configurations below. Depending on matching, NC will apply to certain components. Network Analyzer LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Matching Circuit on Evaluation Board • Line width should be designed to match 50 Ω characteristic impedance, depending on PCB material and thickness. • The component values given above will be vary based on the PCB layout Return Loss, VSWR and Impedance Characteristics Before Matching LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Return Loss, VSWR and Impedance Characteristics Cont. After Matching Radiation Pattern and Gain Test Setup LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain XY Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain XZ Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain YZ Plane LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450G-S1F-T3 Radiation Pattern and Gain 3D – Pattern | (2400 MHz, 2450 MHz, 2500 MHz) Frequency (MHz)Gain (dBi) 2400-4.125434820 2410-4.180958401 2420-3.877599807 2430-3.930632294 2440-3.676540694 2450-3.582882743 2460-3.534294730 2470-3.598055402 2480-3.690017588 2490-3.876259790 2500-3.918544199 Gain LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 03-21-19 Surface Mount WLAN / Bluetooth Chip Antenna (2450MHz) Pb 3.2 x 1.6 x 1.2mm RoHS/RoHS II Compliant MSL = 1 AMCA31-2R450…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Report Number. : R14275554-E1 Applicant : InfoBionic, Inc 400 Totten Pond Rd STE 315 Waltham, MA 02451, U.S.A. Model : MoMe ARC Charger FCC ID : 2AHLC01858 EUT Description : Charger Base Test Standard(s) : FCC 47 CFR PART 15 SUBPART C: 2022 ISED RSS-247 ISSUE 2: 2017 ISED RSS-GEN ISSUE 5 + A2: 2021 Date Of Issue: 2022-10-10 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R14275554-E1 DATE: 2022-10-10 FCC ID: 2AHLC01858 Page 2 of 56 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC REPORT REVISION HISTORY Rev. Issue Date Revisions Revised By V1 2022-10-10 Initial Issue Charles Moody REPORT NO: R14275554-E1 DATE: 2022-10-10 FCC ID: 2AHLC01858 Page 3 of 56 UL LLC 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS REPORT REVISION HISTORY ..................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................5 2. TEST RESULTS SUMMARY ...............................................................................................6 3. TEST METHODOLOGY ......................................................................................................6 4. FACILITIES AND ACCREDITATION ..................................................................................6 5. DECISION RULES AND MEASUREMENT UNCERTAINTY ...............................................7 5.1. METROLOGICAL TRACEABILITY ...............................................................................7 5.2. DECISION RULES ........................................................................................................7 5.3. MEASUREMENT UNCERTAINTY ................................................................................7 5.4. SAMPLE CALCULATION .............................................................................................7 6. EQUIPMENT UNDER TEST ................................................................................................8 6.1. EUT DESCRIPTION .....................................................................................................8 6.2. MAXIMUM OUTPUT POWER .......................................................................................8 6.3. DESCRIPTION OF AVAILABLE ANTENNAS ...............................................................8 6.4. SOFTWARE AND FIRMWARE .....................................................................................8 6.5. WORST-CASE CONFIGURATION AND MODE ...........................................................8 6.6. DESCRIPTION OF TEST SETUP .................................................................................9 7. MEASUREMENT METHOD...............................................................................................10 8. TEST AND MEASUREMENT EQUIPMEN…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David Wayne MacCutcheon(Chief Operating Officer)
[email protected]617-755-6602Fax: 617-531-7777

Technical Contact

UL LLCLariah Sanders
[email protected]919-549-0945

2800 Perimeter Park Dr · Morrisville, North Carolina · United States

Test Firm

UL LLCSteven Thompson
[email protected]919 549 1430

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.28 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Infobionic, Inc.

Gateway - FCC ID 2AHLC01856 - Infobionic, Inc.
2AHLC01856

Gateway

Jan 08, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz