PowerLogicSeries PD100PartialDischargeTag UserManual PowerLogic offerspower quality,uptime andefficiency. GEX5968601-00 08/2022 www.se.com LegalInformation The SchneiderElectric brandand anytrademarks ofSchneider ElectricSE andits subsidiaries referredto inthis guideare theproperty ofSchneider ElectricSE orits subsidiaries. All other brandsmay betrademarks oftheir respectiveowners. This guideand itscontent areprotected underapplicable copyrightlaws and furnished forinformational useonly. Nopart ofthis guidemay bereproduced or transmitted inany formor byany means(electronic, mechanical,photocopying, recording, orotherwise), forany purpose,without theprior writtenpermission of Schneider Electric. Schneider Electricdoes notgrant anyright orlicense forcommercial useof theguide or itscontent, exceptfor anon-exclusive andpersonal licenseto consultit onan "as is" basis.Schneider Electricproducts and equipmentshould beinstalled, operated, serviced, andmaintained onlyby qualifiedpersonnel. As standards,specifications, anddesigns changefrom timeto time,information contained inthis guidemay besubject tochange withoutnotice. To theextent permittedby applicablelaw, noresponsibility orliability isassumed by Schneider Electricand itssubsidiaries forany errorsor omissionsin theinformational content ofthis materialor consequencesarising outof orresulting fromthe useof the information containedherein. As partof agroup ofresponsible, inclusivecompanies, weare updatingour communications thatcontain non-inclusiveterminology. Untilwe completethis process, however,our contentmay stillcontain standardizedindustry termsthat may be deemedinappropriate by ourcustomers. PD100 Partial DischargeTag TableofContents Safety Information......................................................................................5 About theBook...........................................................................................7 Safety Precautions...................................................................................... 8 Presentation................................................................................................ 10 PowerLogic MasterRange....................................................................... 10 PD100 Description.................................................................................... 10 PD100 Dimensions.................................................................................. 11 PD100 FrontFace Description................................................................... 11 PD100 MountingClips ............................................................................. 14 PD100 SerialNumber.............................................................................. 14 Technical Characteristics.......................................................................... 15 Installation................................................................................................. 17 Safety Instructions.................................................................................... 17 Installation Instructions ............................................................................. 17 Wiring....................................................................................................... 19 Operation.................................................................................................... 23 Cybersecurity.......................................................................................... 23 Commissioning ........................................................................................ 23 Unpairing thePD100................................................................................ 24 Diagnostic Mode...................................................................................... 24 Maintenance............................................................................................. 25 Troubleshooting......................................................................................... 26 Radio FrequencyCompliance................................................................ 27 Schneider ElectricGreen Premium™Ecolabel.................................. 29 GEX5968601-003 Safety InformationPD100 Partial DischargeTag SafetyInformation Important Information Read theseinstructions carefullyand lookat theequipment tobecome familiar withthe devicebefore tryingto install,operate, service,or maintain it. Thefollowing specialmessages mayappear throughoutthis documentation oron theequipment towarn ofpotential hazardsor tocall attention toinformation thatclarifies orsimplifies aprocedure. The additionof thissymbol toa “Danger”or “Warning”safety message indicatesthat anelectrical hazardexists whichwill resultin death orserious injuryif theinstructions arenot followed. This isthe safetyalert symbol.It isused toalert youto potential personal injuryhazards. Obeyall safetymessages withthis symbol to avoidpossible injuryor death. DANGER DANGER indicatesa hazardoussituation which,if notavoided, willresult in death orserious injury. Failure tofollow theseinstructions willresult indeath orserious injury. WARNING WARNING indicatesa hazardoussituation which,if notavoided, couldresult in deathor seriousinjury. Failure tofollow theseinstructions canresult indeath, seriousinjury, or equipment damage. CAUTION CAUTION indicatesa hazardoussituation which,if notavoided, couldresult in minor ormoderate injury. Failure tofollow theseinstructions canresult ininjury orequipment damage. NOTICE NOTICE isused toaddress practicesnot relatedto physicalinjury. Failure tofollow theseinstructions canresult inequipment damage. GEX5968601-005 PD100 Partial DischargeTagSafety Information Please Note Electrical equipmentshould be installed,operated, serviced,and maintainedonly by qualifiedpersonnel. Noresponsibility isassumed bySchneider Electric forany consequences arisingout ofthe useof thismaterial. A qualifiedperson isone whohas skillsand knowledgerel…
Text truncated - open the document above for the full version.
CONFIDENTIALITY REQUEST To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: Timco Engineering, Inc. 849 NW State Road 45 Newberry, Florida 32669 - United States August 18, 2022 Subject: Confidentiality request FCC ID: 2AHP8-PD100X001 Schneider Electric requests, pursuant to 47CFR 0.457 and 0.459, post grant confidentiality for portions of the material contained in this application. The following document regarding this submission for FCC ID: 2AHP8-PD100X001 shall be kept confidential: LONG-TERM CONFIDENTIALITY: 1. Block Diagram description of the equipment (file: Block Diagram - 2AHP8-PD100X001.pdf) 2. Operational description of the equipment (file: Operational Description -2AHP8-PD100X001.pdf) 3. Schematic Diagram of the equipment (file: Schematic -2AHP8-PD100X001.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Responsible party: Bertrand Huin Title: Standardization and connected products manager Signature:
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/7 EXTERNAL PHOTOS OF EQUIPMENT FCCID: 2AHP8-PD100X001 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/7 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/7 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 4/7 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 5/7 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 6/7 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 7/7
24/48VDC PowerLogic PD100 IEC 62271-213: SN: PPYYwwDIIInnnnnXXXX Made in : Canada ZIGBEE MAC-ADDRESS: A-F-0123456789XX L2 L3 VDIS L1 L2 L3 COUPLING ELEMENT Consumption: 6.0W Capacitive Coupling Element: 15pF - 40pF VDIS Output: Only connect SE VDIS Arial Rounded size: 5pt Arial Rounded/ Arial Rounded Bold size: 9pt Arial Rounded Bold size: 7 pt Arial Rounded size: 7.5pt Arial Rounded size: 8pt Arial Rounded size: 7pt Arial size: 5pt 24/48VDC PowerLogic PD100 IEC 62271-213: SN: PPYYwwDIIInnnnnXXXX Made in : Canada ZIGBEE MAC-ADDRESS: A-F-0123456789XX L2 L3 VDIS L1 L2 L3 COUPLING ELEMENT ZIGBEE INSTALL CODE: A-F-0123456789XXXXXXXXXXXXXXXXXXXXXX Consumption: 6.0W Capacitive Coupling Element: 15pF - 40pF VDIS Output: Only connect SE VDIS L1 24/48VDC PowerLogic PD100 IEC 62271-213: SN: PPYYwwDIIInnnnnXXXX Made in : Canada ZIGBEE MAC-ADDRESS: A-F-0123456789XX L2 L3 VDIS L1 L2 L3 COUPLING ELEMENT ZIGBEE INSTALL CODE: A-F-0123456789XXXXXXXXXXXXXXXXXXXXXX Consumption: 6.0W Capacitive Coupling Element: 15pF - 40pF VDIS Output: Only connect SE VDIS Arial Rounded size: 6pt Arial Rounded size: 5pt Arial Rounded size: 8pt Normative logotype Step 2 Step 3 VIVALDI MARKING - Technical Label Pantone white SE-GREY6 same color as cover or transparent Cut Typography definition Top view ZIGBEE INSTALL CODE: 83FE D340 7A93 9723 A5C6 39B2 6916 XXXX XXXX 69.95 59.96 74.00 0.15mm R1mm IC: 21245-PD100X001 FCC ID: 2AHP8-PD100X001 IC: 21245-PD100X001 FCC ID: 2AHP8-PD100X001 L1 L1 24/48VDC PowerLogic PD100 IEC 62271-213: SN: PPYYwwDIIInnnnnXXXX Made in : Canada ZIGBEE MAC-ADDRESS: A-F-0123456789XX L2 L3 VDIS L1 L2 L3 COUPLING ELEMENT ZIGBEE INSTALL CODE: A-F-0123456789XXXXXXXXXXXXXXXXXXXXXX Consumption: 6.0W Capacitive Coupling Element: 15pF - 40pF VDIS Output: Only connect SE VDIS IC:XXXXXXX-YYYYYYYYYYY FCC ID xxxxxx L1
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/12 INTERNAL PHOTOS OF EQUIPMENT FCCID: 2AHP8-PD100X001 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/12 RF antenna LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 4/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 5/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 6/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 7/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 8/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 9/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 10/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 11/12 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 12/12
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE FCCID: 2AHP8-PD100X001 Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Prediction Frequency MHz Conducted Output Power dBm Max Antenna Gain dBi Distance cm Power Density mW/cm2 Limit mW/cm2 2405-2.064.7200.00041.00 2440-2.204.7200.00041.00 2480-2.624.7200.00031.00 Conclusion: Therefore our device complies with FCC’s RF radiation exposure limits for general population without SAR evaluation with at least 20cm separation from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Internal PD100 PCB Antenna 29/06/2021 Internal Page 2 Inputs Internal Page 3 Antenna dimensions 50Ohm line Internal Page 4 Reflection coefficient S11 better than -10dB in 2,4GHz ISM band Internal Page 5 Radiation pattern Internal Page 6 Internal Page 7 Internal Page 8
ZIGBEE Template: Release October 22 nd , 2022 This document shall not be reproduced, except in full, without the written approval of the LCIE. This document contains results related only to the items tested. It does not imply the conformity of the whole production to the items tested. . Unless otherwise specified or rule defined by the test method, the decision of conformity doesn’t take into account the uncertainty of measures.This document doesn’t anticipate any certification decision. The COFRAC accreditation attests the technical capability of the testing laboratory for the only tests covered by the accreditation. If some tests mentioned in this report are carried out outside the framework of COFRAC accreditation, they are indicated by the symbol. Accreditation N°1-1633 Scope available on www.cofrac.fr TEST REPORT N°: 15266217-779404-A(FILE#4222448) Version : 02 Subject Radio spectrum matters tests according to standards: 47 CFR Part 15.247 & RSS-247 Issue 2 & RSS-Gen Issue 5 Issued to Schneider Electric 28 Rue Henri Tarze 38000 - Grenoble France Apparatus under test Product PowerLogic PD100 Trade mark Schneider Electric Manufacturer Schneider Electric Model under test PD100 Serial number MP2219400162399 FCC ID 2AHP8-PD100X001 IC 21245-PD100X001 Conclusion See Test Program chapter Test date July 20, 2022 to August 24, 2022 Test location Moirans FCC Test site FR0008 - 197516 ISED Test site FR0008 - 6500A Sample receipt date July 20, 2022 Composition of document 52 pages Document issued on August 25, 2022 Written by : Approved by : Majid MOURZAGH Anthony MERLIN Tests operator Technical manager TEST REPORT N° 15266217-779404-A Version : 02 Page 2/52 PUBLICATION HISTORY Version Date Author Modification 01 August 11, 2022 Majid MOURZAGH Creation of the document 02 August 25, 2022 Majid MOURZAGH Change test for conducted method §3, §4, §5, §6 and §7 Each new edition of this test report replaces and cancels the previous edition. The control of the old editions of report is under responsibility of client. TEST REPORT N° 15266217-779404-A Version : 02 Page 3/52 SUMMARY 1. TEST PROGRAM ............................................................................................................................... 4 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) ................................ 5 3. OCCUPIED BANDWIDTH ................................................................................................................. 11 4. 6DB EMISSION BANDWIDTH .......................................................................................................... 14 5. MAXIMUM CONDUCTED OUTPUT POWER ................................................................................... 17 6. POWER SPECTRAL DENSITY ........................................................................................................ 21 7. UNWANTED EMISSIONS INTO NON-RESTRICTED FREQUENCY BANDS AT THE BAND EDGE 24 8. UNWANTED EMISSIONS INTO NON-RESTRICTED FREQUENCY BANDS ................................... 27 9. AC POWER LINE CONDUCTED EMISSIONS.................................................................................. 30 10. UNWANTED EMISSIONS IN RESTRICTED FREQUENCY BANDS ................................................ 38 11. UNCERTAINTIES CHART ................................................................................................................ 52 TEST REPORT N° 15266217-779404-A Version : 02 Page 4/52 1. TEST PROGRAM References ➢ 47 CFR Part 15.247 ➢ RSS 247 Issue 2 ➢ RSS Gen Issue 5 ➢ KDB 558074 D01 DTS Meas Guidance v05r02 ➢ ANSI C63.10-2013 Radio requirement: Clause (47CFR Part 15.247 & RSS-247 Issue 2 & RSS-Gen Issue 5) Test Description Test result - Comments Occupied Bandwidth PASS FAIL NA NP(1) 6dB Bandwidth PASS FAIL NA() NP(1) Duty Cycle PASS FAIL NA NP(1) Maximum Conducted Output Power PASS FAIL NA NP(1) Power Spectral Density PASS FAIL NA NP(1) Conducted Spurious Emission at the Band Edge PASS FAIL NA() NP(1) Unwanted Emissions into Non-Restricted Frequency Bands PASS FAIL NA() NP(1) AC Power Line Conducted Emission PASS FAIL NA(2) NP(1) Unwanted Emissions into Restricted Frequency Bands PASS FAIL NA NP(1) Receiver Radiated emissions PASS FAIL NA NP(1) This table is a summary of test report, see conclusion of each clause of this test report for detail. (1): Limited program (2): EUT not directly or indirectly connected to the AC Power Public Network PASS: EUT complies with standard’s requirement FAIL: EUT does not comply with standard’s requirement NA: Not Applicable NP: Test Not Performed TEST REPORT N° 15266217-779404-A Version : 02 Page 5/52 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) 2.1. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES): Equipment under test (EUT): Schneider Electric PD100 Serial Number: MP2219400162399 Equipment Under Test Power supply: During all the tests, EUT is supplied by V nom : 24VDC For measurement with different voltage, it will be presented in test method. Name Type Rating Reference / Sn Comments Supply1 AC DC Battery 24V/48VDC Voltage table used (for Power Line Conducted Emissions): Type Measurement performed: AC 120VAC/60Hz 240VAC/50Hz DC +24VDC -+24VDC TEST REPORT N° 15266217-779404-A Version : 02 Page 6/52 Inputs/outputs - Cable: Access Type Length used (m) Declared <3m Shielded Under test Comments Supply1 2wires 1.1 Coupling Element cablet 4 wires 1.1 VDIS_cable 4 wires 1.1 Auxiliary equipment used during test: Type Reference Sn Comments Laptop LENOVO ThinkBook / / BT interface board / / / Power supply DC METRIX AX503 / LCIE: A7042308 Equipment information: Type: ZIGBEE RF4CE Frequency band: [2400 – 2483.5] MHz Number of Channel: 16 Spacing channel: 5MHz Channel bandwidth: 2MHz Antenna Type: Integral External Dedicated Antenna connector: Yes No Temporary for test Transmit cha…
Text truncated - open the document above for the full version.
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/5 CONDUCTED AND RADIATED MEASUREMENT PHOTO FCCID: 2AHP8-PD100X001 1.1 Conducted emission LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 2/5 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 3/5 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 4/5 1.2 Radiated emissions Photograph for Unwanted Emission in restricted frequency bands on FAR LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 5/5
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 622.00 µW |