FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Smart Meter Corporation/
  3. 2AHYZGM291CAT-M1

2AHYZGM291CAT-M1Blood Glucose measurement device with 4G-CAT-M1 connectivity

Smart Meter Corporation
Blood Glucose measurement device with 4G-CAT-M1 connectivity - FCC ID 2AHYZGM291CAT-M1 - Smart Meter Corporation
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Feb 06, 2020
Application Purpose
Original Equipment
Date of Application
Jan 26, 2020
Equipment Note
Blood Glucose measurement device with 4G-CAT-M1 connectivity
Frequency Range
699.00000000 - 716.00000000
Company
Smart Meter Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

Attestation Statements

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21048 Date: 1/27/2020 Subject: Request for Short Term Confidentiality FCC-ID: 2AHYZGM291CAT-M1 To Whom It May Concern: In accordance with §0.457(d) and §0.459 of CFR 47, Smart Meter, LLC hereby requests short term confidentiality for documents filed under the following exhibit types: 1. External Photographs 2. Internal Photographs 3. User / Instruction Manual 4. Test Set-up Photographs until the product will be publicly announced. Short term confidentiality release date / period: 180 days from grant issue date (max 180 days from grant issue date These items contain detailed system and equipment description and related information about the product which Smart Meter, LLC considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Smart Meter, LLC also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. We are informed and aware of our obligation that we have to inform the involved TCB in written and in due time if we intend to market the product prior to the above specified confidentiality release date so that the short term confidentiality classification can be reset prior to product launch. We are aware that exhibit types cover letters, attestations, label document, test reports, RF exposure information (SAR and MPE reports), cannot be requested to be classified confidential and are thus subject to publication, as will be documents of all other exhibits types for which we have not requested a confidentiality classification. Best Regards, ____________________________________ Signature Name: Dick Kane Title: Director of Operations Company Name: Smart Meter, LLC Address: 201 E. Kennedy Blvd. Suite 880, Tampa, FL 33602

Attestation Statements

Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21048 Date: 1/27/2020 Subject: Request for Permanent Confidentiality FCC ID: 2AHYZGM291CAT-M1 To Whom It May Concern: In accordance with §0.457(d) and §0.459 of CFR 47, and KDB 726920, Smart Meter, LLC hereby requests permanent confidentiality for documents filed under the following exhibit types: 1. Block Diagram 2. Schematic Diagram 3. Part List 4. Operational Description These items contain detailed system and equipment description and related information about the product which Smart Meter, LLC considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Smart Meter, LLC also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. We are aware that exhibit types cover letters, attestations, label document, test reports, RF exposure information (SAR and MPE reports), cannot be requested to be classified confidential and are thus subject to publication, as will be documents of all other exhibits types for which we have not requested a confidentiality classification. Best Regards, _______________________________ Signature Name: Dick Kane Title: Director of Operations Company Name: Smart Meter, LLC Address: 201 E. Kennedy Blvd., Suite 880, Tampa, FL 33602

Attestation Statements

Smart Meter, LLC 201 E. Kennedy Blvd., Suite 880 Tampa, FL 33602 Jan uary 20 th , 2020 Subject: Validity of Test Results from Testing / Certification of the Integrated Module To Whom It May Concern: We, Smart Meter Corporation, 201 E. Kennedy Blvd., Suite 880, Tampa, FL, 33602, hereby declare that that the test results from conducted tests applied to the radio module: Manufacturer: u- Blox AG Model: SARA 410M FCC ID: XPY2AGQN4NNN w hich is incorporated in our host equipment: Manufacturer: Smart Meter Corporation Model: GM291-v2 FCC ID: 2AHYZGM291CAT-M1 and as reported in module test report(s): Report Number: SD72128174-0517B by TUV SUD, Issue Date: May 2017 Report Number: SD72128174-0517A by TUV SUD, Issue Date: May 2017 ac curately represent the test results under the new conditions when the identified radio module is integrated in the identified host equipment. By integration of the said radio module into the identified host equipment no changes were made to it or by external adaptation circuitry that impacts the validity of the results of the original module’s test reports; hence conducted signal measurements in the above listed reports also apply to GM291-v2: Sincerely, Dick Kane Director of Operations 201 E. Kennedy Blvd., Suite 880 Tampa, FL 33602 813 773 4080 (Office) x103 [email protected] www.smartmetercorporation.com www.iglucose.com

Attestation Statements

To Whom it may concern, Smart Meter, LLC 201 E. Kennedy Blvd., Suite 880 Tampa, FL 33602 January 8, 2020 The iGlucose GM291-v2 is battery operated and is handheld during measurement operation. The product is designed in such a way that data is only transmitted after a successful measurement of blood sugar content using the analysis function of the device. As the device is minimally invasive and does not require strict privacy for use, data transmissions are possible when the device is carried next to the body of the patient and in the same vicinity as persons of general public. The device is turned On/Off manually with the On/Off button. In any normal use case, each use of the device will be separately by time of from one (1) to 24 hours. In an unusual use case of more frequent measurements, due to the time required for the device to complete a measurement and the preparation time needed on behalf of the patient, such an unusual measurement event will happen no more than 3 times within 6 minutes. This number was found conservative by our internal QM functional testing. Whether the device is used in private or by medical professionals does not affect the above as the device is designed to be used by individuals after initial training through healthcare professional. The steps performed during a single measurement are outlined in detail in our owner’s manual starting page 27. Each measurement event is associated with a maximum 70 Byte data packet that is transmitted through the CAT M1 radio module as soon as a network connection can be established. Max application data in 2 minutes (1 blood sugar measurement) = 70 Bytes. Adding 20 Bytes TCP overhead and 20 Bytes IP4 overhead resulting packet size for 1 blood sugar measurement = 110 Bytes. Worst case LTE settings are for TBS Index = 0 (maximum channel coding) and for 1 RB (maximum spread of transmissions over time) resulting in Transport Block size of 16kbps based on 3GPP TS 36.213. To transmit 110 Bytes = 880 Bits on 16 kbps takes = 880 / (16 x 1024) s = 0.054 seconds. With the 120 sec each measurement takes this results in a maximum duty cycle of 0.00045. To then apply a safety factor of 81 as detailed below this results in a maximum duty cycle of 0.036 We are applying a safety factor of 81 to this with the following rationale: - The LTE HARQ mechanism will retransmit if transport block not acknowledged (x3) - The LTE Mac layer will retransmit if frames are not acknowledged (x3) - The TCB layer will retry transmissions up to 3 times (x3) - Measurements may be queued after a user enters back into network coverage (e.g. after a long camping trip). Our device is designed to transmit these stored readings after a successful measurement of blood sugar measurement where the device is back in coverage. There is no additional protocol overhead for the transmission of stored readings, thus this data is transmitted very quickly and efficiently. The resulting maximum duty cycle originating from our device is DC = 0.036 Regards, Dick Kane here Type text

ID Label/Location Info

Label Draft FCC ID: 2AHYZGM291CAT-M1 Size 1:1 Note that the font is Calibri with font size 6. As long as no scaling is applied in the printing process this will meet the 4pt requirement ... even if another random font is picked with a font size > 4 points. iGlucose GM291-v2 Cellular Blood Glucose Meter Smart Meter LLC 201E. Kennedy blvd., Suite 880 Tampa, Fl 33602 www.iglucose.com FCC ID: 2AHYZGM291CAT-M1

Internal Photos

Internal Pictures: Smart Meter – iGlucose – FCC ID: 2AHYZGM291CAT-M1

Internal Photos

Internal Pictures: Smart Meter – iGlucose – FCC ID: 2AHYZGM291CAT-M1

Internal Photos

Internal Pictures: Smart Meter – iGlucose – FCC ID: 2AHYZGM291CAT-M1

RF Exposure Info

A2LA Accredited IC recognized # 3462B-1 CETECOM Inc. 411 Dixon Landing Road  Milpitas, CA 95035  U.S.A. Phone: + 1 (408) 586 6200  Fax: + 1 (408) 586 6299  E-mail: [email protected]  http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2905571 © Copyright by CETECOM Radio Frequency Exposure Evaluation Report FOR: KORE Wireless Inc. Model Name: iGlucose GM291-v2 Product Description: Cellular Blood Glucose Meter FCC ID: 2AHYZGM291CAT-M1 Applied Rules and Standards: CFR 47 Part 2.1093 FCC KDB 447498 D01 General RF Exposure Guidance v06 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 DATE: 2020-02-07 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 2 of 8 Contents 1. Assessment ................................................................................................................................... 3 2. Administrative Data ..................................................................................................................... 4 2.1. Identification of the Testing Laboratory Issuing the Test Report ......................................... 4 2.2. Identification of the Client / Manufacturer ............................................................................ 4 3. Equipment under Assessment ...................................................................................................... 5 4. FCC Exemption Limits for Routine Evaluation ........................................................................... 6 4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06 6 5. Stand-Alone SAR Evaluation Exclusion ...................................................................................... 7 5.1. Justification for using the 5 mm Distance ............................................................................. 7 5.2. SAR Exclusion Calculation Table ......................................................................................... 7 6. Revision History ........................................................................................................................... 8 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 3 of 8 1. Assessment The following device meets the limits of general population uncontrolled exposure specified in CFR 47 Part 2.1093 according to SAR evaluation exclusion requirements specified in FCC regulation as listed in KDB 447498, as it has been evaluated against the standards mentioned above under this section. Responsible for the Report: 2020-02-07 Compliance Kris Lazarov (Sr. EMC Engineer) Date Section Name Signature The test results of this test report relate exclusively to the test item specified in Section3. CETECOM Inc. USA does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of CETECOM Inc. USA. Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 4 of 8 2. Administrative Data 2.1. Identification of the Testing Laboratory Issuing the Test Report Company Name: CETECOM Inc. Department: Compliance Street Address: 411 Dixon Landing Road City/Zip Code Milpitas, CA 95035 Country USA Telephone: +1 (408) 586 6200 Fax: +1 (408) 586 6299 Compliance Manager: Cindy Li Responsible Project Manager: Rami Saman 2.2. Identification of the Client / Manufacturer Client’s Name: KORE Wireless Inc. Street Address: 161 Protage Avenue, Suite 300 City/Zip Code Winnipeg, MB / R3B 2L6 Country Canada Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 5 of 8 3. Equipment under Assessment Model No: iGlucose GM291-v2 HW Version : 17006-1-REV-C1 SW Version : V1.5.0 FCC-ID: FCC ID: 2AHYZGM291CAT-M1 Minimum distance of antenna or radiating parts to user 5mm Operating Temperature Range: 10°C ~ 40°C Modes of Operation: LTE Cat-M Radios included in the device:  LTE  Module name: u-blox, SARA-R410-02B on OTA measurement) M Antenna: <6dBi(based-CAT EUT Dimensions [mm]:  104 × 49.8 × 16.5 Co-located Transmitters/ Antennas: Yes  No Exposure Category:  Occupational/ Controlled  General Population/ Uncontrolled Device Category: Fixed Installation Mobile  Portable  Mixed Mobile and Portable EUT Diameter:  < 60 cm  Other __________ Sample Revision Prototype Unit; Production Unit; Pre-Production Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 6 of 8 4. FCC Exemption Limits for Routine Evaluation 4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06 KDB 447498 Section: 4.3.1. Standalone SAR test exclusion considerations a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Rep…

Text truncated - open the document above for the full version.

RF Exposure Info

A2LA Accredited IC recognized # 3462B-1 CETECOM Inc. 411 Dixon Landing Road  Milpitas, CA 95035  U.S.A. Phone: + 1 (408) 586 6200  Fax: + 1 (408) 586 6299  E-mail: [email protected]  http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2905571 © Copyright by CETECOM Radio Frequency Exposure Evaluation Report FOR: KORE Wireless Inc. Model Name: iGlucose GM291-v2 Product Description: Cellular Blood Glucose Meter FCC ID: 2AHYZGM291CAT-M1 Applied Rules and Standards: CFR 47 Part 2.1093 FCC KDB 447498 D01 General RF Exposure Guidance v06 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 DATE: 2020-02-07 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 2 of 8 Contents 1. Assessment ................................................................................................................................... 3 2. Administrative Data ..................................................................................................................... 4 2.1. Identification of the Testing Laboratory Issuing the Test Report ......................................... 4 2.2. Identification of the Client / Manufacturer ............................................................................ 4 3. Equipment under Assessment ...................................................................................................... 5 4. FCC Exemption Limits for Routine Evaluation ........................................................................... 6 4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06 6 5. Stand-Alone SAR Evaluation Exclusion ...................................................................................... 7 5.1. Justification for using the 5 mm Distance ............................................................................. 7 5.2. SAR Exclusion Calculation Table ......................................................................................... 7 6. Revision History ........................................................................................................................... 8 Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 3 of 8 1. Assessment The following device meets the limits of general population uncontrolled exposure specified in CFR 47 Part 2.1093 according to SAR evaluation exclusion requirements specified in FCC regulation as listed in KDB 447498, as it has been evaluated against the standards mentioned above under this section. Responsible for the Report: 2020-02-07 Compliance Kris Lazarov (Sr. EMC Engineer) Date Section Name Signature The test results of this test report relate exclusively to the test item specified in Section3. CETECOM Inc. USA does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of CETECOM Inc. USA. Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 4 of 8 2. Administrative Data 2.1. Identification of the Testing Laboratory Issuing the Test Report Company Name: CETECOM Inc. Department: Compliance Street Address: 411 Dixon Landing Road City/Zip Code Milpitas, CA 95035 Country USA Telephone: +1 (408) 586 6200 Fax: +1 (408) 586 6299 Compliance Manager: Cindy Li Responsible Project Manager: Rami Saman 2.2. Identification of the Client / Manufacturer Client’s Name: KORE Wireless Inc. Street Address: 161 Protage Avenue, Suite 300 City/Zip Code Winnipeg, MB / R3B 2L6 Country Canada Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 5 of 8 3. Equipment under Assessment Model No: iGlucose GM291-v2 HW Version : 17006-1-REV-C1 SW Version : V1.5.0 FCC-ID: FCC ID: 2AHYZGM291CAT-M1 Minimum distance of antenna or radiating parts to user 5mm Operating Temperature Range: 10°C ~ 40°C Modes of Operation: LTE Cat-M Radios included in the device:  LTE  Module name: u-blox, SARA-R410-02B on OTA measurement) M Antenna: <6dBi(based-CAT EUT Dimensions [mm]:  104 × 49.8 × 16.5 Co-located Transmitters/ Antennas: Yes  No Exposure Category:  Occupational/ Controlled  General Population/ Uncontrolled Device Category: Fixed Installation Mobile  Portable  Mixed Mobile and Portable EUT Diameter:  < 60 cm  Other __________ Sample Revision Prototype Unit; Production Unit; Pre-Production Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Report: 2020-02-07 Page 6 of 8 4. FCC Exemption Limits for Routine Evaluation 4.1. FCC SAR test exclusions are set by KDB 447498 D01 General RF Exposure Guidance v06 KDB 447498 Section: 4.3.1. Standalone SAR test exclusion considerations a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. Test Report #: EMC_KORET-019-19001_FCC_SAR_EX_Rev2 FCC ID: 2AHYZGM291CAT-M1 Date of Rep…

Text truncated - open the document above for the full version.

Test Report

Report No. SD72128174-0517B May 2017 America Report On Application for Grant of Equipment Authorization of the u-blox AG SARA-R410M LTE Cat-M1 Module FCC CFR 47 Part 2, Part 22 and 24 ISED RSS-Gen and RSS-132 and RSS-133 FCC ID XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517B Page 2 of 74 REPORT ON TEST REPORT NUMBER PREPARED FOR Radio Testing of the u-blox AG LTE Cat-M1 Module SD72128174-0517B u-blox AG Zuercherstrasse 68 8800 Thalwil, Switzerland CONTACT PERSON Jake Bascon Sr. Certification Engineer (858) 847-9611 x616 [email protected] PREPARED BY Ferdinand S. Custodio Name Authorized Signatory Title: EMC/Senior Wireless Test Engineer APPROVED BY Juan Manuel Gonzalez Name Authorized Signatory Title: EMC SL Manager West Region DATED June 20, 2017 FCC ID XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517B Page 3 of 74 Revision History SD72128174-0517B u-blox AG SARA-R410M LTE Cat-M1 Module DATE OLD REVISION NEW REVISION REASON PAGES AFFECTED APPROVED BY 06/20/17 Initial Release Juan M Gonzalez FCC ID XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517B Page 4 of 74 CONTENTS Section Page No 1 REPORT SUMMARY ............................................................................................................................... 5 1.1 Introduction ................................................................................................................................................ 6 1.2 Brief Summary Of Results ........................................................................................................................... 8 1.1 Product Information ................................................................................................................................... 9 1.2 EUT Test Configuration ............................................................................................................................. 12 1.3 Deviations From The Standard ................................................................................................................. 14 1.4 Modification Record ................................................................................................................................. 14 1.5 Test Methodology ..................................................................................................................................... 14 1.8 Sample Calculations .................................................................................................................................. 16 2 TEST DETAILS ...................................................................................................................................... 17 2.1 Transmitter Conducted Output Power ..................................................................................................... 18 2.2 Effective Radiated Power .......................................................................................................................... 21 2.3 Equivalent Isotropic Radiated Power ........................................................................................................ 23 2.4 Occupied Bandwidth ................................................................................................................................. 25 2.5 Peak-Average Ratio ................................................................................................................................... 31 2.6 Band Edge/Conducted Spurious Emissions ............................................................................................... 34 2.7 Field Strength Of Spurious Radiation ........................................................................................................ 46 2.8 Frequency Stability ................................................................................................................................... 52 2.9 Receiver Spurious Emissions ..................................................................................................................... 58 2.10 Power Line Conducted Emissions ............................................................................................................. 59 3 TEST EQUIPMENT USED ...................................................................................................................... 63 3.1 Test Equipment Used ................................................................................................................................ 64 3.2 Measurement Uncertainty ....................................................................................................................... 65 4 DIAGRAM OF TEST SETUP ................................................................................................................... 67 4.1 Test Setup Diagram ................................................................................................................................... 68 5 ACCREDITATION, DISCLAIMERS AND COPYRIGHT ............................................................................... 73 FCC ID XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517B Page 5 of 74 SECTION 1 REPORT SUMMARY Radio Testing of the u-blox AG SARA-R410M LTE Cat-M1 Module FCC ID XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517B Page 6 of 74 1.1 INTRODUCTION The information contained in this report is intended to show verification of the u-blox AG LTE Cat-M1 Module to the requirements of the following:  FCC CFR 47 Part 2, Part 22 and 24  ISED RSS-Gen and RSS-132 and RSS-133. Objective To perform Radio Testing to determine the Equipment Under Test's (EUT’s) compliance with the Test Specification, for the series of tests carried out. Manufacturer u-blox AG Product Marketing Name SARA-R410M Model Number(s) SARA-R410M FCC ID Number XPY2AGQN4NNN IC Number 8595A-2AGQN4NNN Serial Number(s) 357591080023101 and 357591080022319 Number of Samples Tested 2 Test Specification/Issue/Date  FCC CFR 47 Part…

Text truncated - open the document above for the full version.

Test Report

Report No. SD72128174-0517A May 2017 America Report On Application for Grant of Equipment Authorization of the u-blox AG SARA-R410M LTE Cat-M1 Module FCC CFR 47 Part 2 and 27 ISED RSS-Gen, RSS-130 and RSS-139 FCC ID: XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517A Page 2 of 73 REPORT ON TEST REPORT NUMBER PREPARED FOR Radio Testing of the u-blox AG LTE Cat-M1 Module SD72128174-0517A u-blox AG Zuercherstrasse 68 8800 Thalwil, Switzerland CONTACT PERSON Jake Bascon Sr. Certification Engineer (858) 847-9611 x616 [email protected] PREPARED BY Ferdinand S. Custodio Name Authorized Signatory Title: EMC/Senior Wireless Test Engineer APPROVED BY Juan Manuel Gonzalez Name Authorized Signatory Title: EMC SL Manager West Region DATED June 20, 2017 FCC ID: XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517A Page 3 of 73 Revision History SD72128174-0517A u-blox AG M/N SARA-R410M SARA-R410M LTE Cat-M1 Module DATE OLD REVISION NEW REVISION REASON PAGES AFFECTED APPROVED BY 06/20/2017 Initial Release Juan M Gonzalez FCC ID: XPY2AGQN4NNN IC: 8595A-2AGQN4NNN Report No. SD72128174-0517A Page 4 of 73 CONTENTS Section Page No 1 REPORT SUMMARY ............................................................................................................................... 5 1.1 Introduction ................................................................................................................................................ 6 1.2 Brief Summary Of Results ........................................................................................................................... 7 1.3 Product Information ................................................................................................................................... 8 1.4 EUT Test Configuration ............................................................................................................................. 11 1.5 Deviations From The Standard ................................................................................................................. 13 1.6 Modification Record ................................................................................................................................. 13 1.7 Test Methodology ..................................................................................................................................... 13 1.8 Test Facility Location ................................................................................................................................. 13 1.9 Test Facility Registration ........................................................................................................................... 14 1.10 Sample Calculations .................................................................................................................................. 15 2 TEST DETAILS ...................................................................................................................................... 16 2.1 Transmitter Conducted Output Power ..................................................................................................... 17 2.2 Radiated Power ......................................................................................................................................... 20 2.3 Occupied Bandwidth ................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Erez Pick(VP perations)
[email protected]813-773-4080Fax: 908-347-9846

Test Firm

CETECOM Inc.Meinolf Glunz
[email protected]408-586-6301

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
627699 MHz - 716 MHz150.00 mW134KF7W1 ppm
Confidentiality
Long Term
Grant Notes
Powers listed are ERP below- and EIRP above 1 GHz

Other Applications from Smart Meter Corporation

2AHYZGM291R5C-M1

Blood Glucose Monitoring System

Nov 15, 2022

Equipment Class

PCB - PCS Licensed Transmitter