FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Huafurui Technology Co., Ltd./
  3. 2AHZ5MPAD

2AHZ5MPADTablet

Shenzhen Huafurui Technology Co., Ltd.
Tablet - FCC ID 2AHZ5MPAD - Shenzhen Huafurui Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 13, 2026
Application Purpose
Original Equipment
Equipment Note
Tablet
Frequency Range
5180.00000000 - 5240.00000000
Company
Shenzhen Huafurui Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 17 FCCCaution: Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance couldvoidtheuser'sauthoritytooperatetheequipment. NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto correcttheinterferencebyoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferent fromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeused inportableexposureconditionwithoutrestriction. SpecificAbsorptionRate(SAR)information: Thisdevicemeetsthegovernment'srequirementsforexposuretoradiowaves.Theguidelines arebasedonstandardsthatweredevelopedbyindependentscientificorganizationsthrough periodicandthoroughevaluationofscientificstudies.Thestandardsincludeasubstantialsafety margindesignedtoassurethesafetyofallpersonsregardlessofageorhealth.FCCRFExposure InformationandStatementtheSARlimitofUSA(FCC)is1.6W/kgaveragedoveronegramof tissue.Devicetypes:ThisdevicehasalsobeentestedagainstthisSARlimit. Thisdevicewastestedfortypicalbody-wornoperationswiththebackoftheThisdevicekept 0mmfromthebody.TomaintaincompliancewithFCCRFexposurerequirements,useaccessories thatmaintainan0mmseparationdistancebetweentheuser'sbodyandthebackofThisdevice. Theuseofbeltclips,holstersandsimilaraccessoriesshouldnotcontainmetalliccomponentsin itsassembly.Theuseofaccessoriesthatdonotsatisfytheserequirementsmaynotcomplywith FCCRFexposurerequirements,andshouldbeavoided.

RF Exposure Info

Page 101 of 173 Report No.: AiTSZ-260609078FW1 E. Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 1.191 0.531 0.166 0.117 0.111 0.090 0.073 F. 3D Image 3D screen shot Hot spot position Page 102 of 173 Report No.: AiTSZ-260609078FW1 #13 Date of measurement: 9/6/2026 A. Experimental conditions. Probe 0523-EPGO-403 ConvF 2.08 Area Scan dx=15mm dy=15mm, Complete Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5.0mm,Complete Phantom ELLI Device Position Body Band LTE band 12 Channel Center [EARFCN] / Channel Center [MHz] Middle (23095)/ frequency 707.50 Mhz B. Permitivity Middle TX Frequency (MHz) 707.50 Relative permitivity (real part) 42.127 Relative permitivity (imaginary part) 23.264 Conductivity (S/m) 0.914 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-26.00, Y=-120.00 ; SAR Peak: 0.23 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.108 SAR 1g (W/Kg) 0.169 Variation (%) 2.770 Horizontal validation criteria: minimum distance (mm) 11.313708 Vertical validation criteria: SAR ratio M2/M1 (%) 65.882353 Page 103 of 173 Report No.: AiTSZ-260609078FW1 E. Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.238 0.170 0.112 0.109 0.062 0.058 0.040 F. 3D Image 3D screen shot Hot spot position Page 104 of 173 Report No.: AiTSZ-260609078FW1 #14 Date of measurement: 9/6/2026 A. Experimental conditions. Probe 0523-EPGO-403 ConvF 2.08 Area Scan dx=15mm dy=15mm, Complete Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5.0mm,Complete Phantom ELLI Device Position Body Band LTE band 17 Channel Center [EARFCN] / Channel Center [MHz] Middle (23790)/ frequency 710.00 Mhz B. Permitivity Middle TX Frequency (MHz) 710.00 Relative permitivity (real part) 42.113 Relative permitivity (imaginary part) 23.152 Conductivity (S/m) 0.913 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-26.00, Y=-119.00 ; SAR Peak: 0.39 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.068 SAR 1g (W/Kg) 0.122 Variation (%) 4.500 Horizontal validation criteria: minimum distance (mm) 8.000000 Vertical validation criteria: SAR ratio M2/M1 (%) 30.851064 Page 105 of 173 Report No.: AiTSZ-260609078FW1 E. Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.425 0.188 0.058 0.055 0.036 0.043 0.025 F. 3D Image 3D screen shot Hot spot position Page 106 of 173 Report No.: AiTSZ-260609078FW1 Appendix D. Calibration Certificate Table of contents E Field Probe - 0523-EPGO-403 750 MHz Dipole - SN 2614 DIP0G750-325 900 MHz Dipole - SN 1811-DIP0G900-151 1800 MHz Dipole - 1811-DIP1G800-152 1900 MHz Dipole - 1811-DIP1G900-153 2450 MHz Dipole - SN 1811-DIP2G450-155 2600 MHz Dipole - SN 2614-DIP2G600-326 5200-5800 MHz Dipole - SN 2923-DIP5G000-730 Page 107 of 173 Report No.: AiTSZ-260609078FW1 Page 108 of 173 Report No.: AiTSZ-260609078FW1 Page 109 of 173 Report No.: AiTSZ-260609078FW1 Page 110 of 173 Report No.: AiTSZ-260609078FW1 Page 111 of 173 Report No.: AiTSZ-260609078FW1 Page 112 of 173 Report No.: AiTSZ-260609078FW1 Page 113 of 173 Report No.: AiTSZ-260609078FW1 Page 114 of 173 Report No.: AiTSZ-260609078FW1 Page 115 of 173 Report No.: AiTSZ-260609078FW1 Page 116 of 173 Report No.: AiTSZ-260609078FW1 Page 117 of 173 Report No.: AiTSZ-260609078FW1 Page 118 of 173 Report No.: AiTSZ-260609078FW1 Page 119 of 173 Report No.: AiTSZ-260609078FW1 Page 120 of 173 Report No.: AiTSZ-260609078FW1 Page 121 of 173 Report No.: AiTSZ-260609078FW1 Page 122 of 173 Report No.: AiTSZ-260609078FW1 Page 123 of 173 Report No.: AiTSZ-260609078FW1 Page 124 of 173 Report No.: AiTSZ-260609078FW1 Page 125 of 173 Report No.: AiTSZ-260609078FW1 Page 126 of 173 Report No.: AiTSZ-260609078FW1 Page 127 of 173 Report No.: AiTSZ-260609078FW1 Page 128 of 173 Report No.: AiTSZ-260609078FW1 Page 129 of 173 Report No.: AiTSZ-260609078FW1 Page 130 of 173 Report No.: AiTSZ-260609078FW1 Page 131 of 173 Report No.: AiTSZ-260609078FW1 Page 132 of 173 Report No.: AiTSZ-260609078FW1 Page 133 of 173 Report No.: AiTSZ-260609078FW1 Page 134 of 173 Report No.: AiTSZ-260609078FW1 Page 135 of 173 Report No.: AiTSZ-260609078FW1 Page 136 of 173 Report No.: AiTSZ-260609078FW1 Page 137 of 173 Report No.: AiTSZ-260609078FW1 Page 138 of 173 Report No.: AiTSZ-260609078FW1 Page 139 of 173 Report No.: AiTSZ-260609078FW1 Page 140 of 173 Report No.: AiTSZ-260609078FW1 Page 141 of 173 Report No.: AiTSZ-260609078FW1 Page 142 of 173 Report No.: AiTSZ-260609078FW1 Page 143 of 173 Report No.: AiTSZ-260609078FW1 Page 144 of 173 Report No.: AiTSZ-260609078FW1 Page 145 of 173 Report No.: AiTSZ-260609078FW1 Page 146 of 173 Report No.: AiTSZ-260609078FW1 Page 147 of 173 Report No.: AiTSZ-260609078FW1 Page 148 of 173 Report No.: AiTSZ-260609078FW1 Page 149 of 173 Report No.: AiTSZ-260609078FW1 Page 150 of 173 Report No.: AiTSZ-260609078FW1

Test Setup Photos

FCC ID: 2AHZ5MPAD Test Positions Front Side (Separation distance of 0mm) Back Side (Separation distance of 0mm) Left Side (Separation distance of 0mm) Right Side (Separation distance of 0mm) Top Side (Separation distance of 0mm) Bottom Side (Separation distance of 0mm)

Test Setup Photos

Page1of2FCCID:2AHZ5MPAD GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2AHZ5MPAD GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3 TestSetupPhoto(s)ofRFConducted Fig.4

Test Report

Page1of41FCCID:2AHZ5MPADReportNo.:LCSC05276013EE GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For ShenzhenHuafuruiTechnologyCo.,Ltd. Tablet TestModel:MegaPad AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ShenzhenHuafuruiTechnologyCo.,Ltd. Address: Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding,No. 993JiaxianRoad,XiangjiaotangCommunity,BantianStreet,Longgang District,Shenzhen,P.R.China Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:May27,2026 Numberoftestedsamples:2 SampleNo.:C260527005-1,C260527005-2 Serialnumber:Prototype DateofTest:May27,2026~July06,2026 DateofReport:July07,2026 Page2of41FCCID:2AHZ5MPADReportNo.:LCSC05276013EE GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15E(15.407) ReportReferenceNo......................:LCSC05276013EE DateofIssue.......................................:July07,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–¡ Otherstandardtestingmethodâ–¡ Applicant’sName.............................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address................................................: Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China TestSpecification Standard..............................................:FCCCFR47PART15E(15.407) TestReportFormNo......................:TRF-4-E-118A/0 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:Tablet TradeMark..........................................:CUBOT TestModel...........................................:MegaPad Ratings.................................................:PleaseRefertoPage6 Result...................................................:Pass Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of41FCCID:2AHZ5MPADReportNo.:LCSC05276013EE GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT TestResult:Pass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC05276013EE July07,2026 Dateofissue EUT.........................................:Tablet TestModel...............................:MegaPad Applicant...............................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address..................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address...................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Factory...................................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address...................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Page4of41FCCID:2AHZ5MPADReportNo.:LCSC05276013EE GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July07,2026InitialIssue--- Page5of41FCCID:2AHZ5MPADReportNo.:LCSC05276013EE GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS 1.GENERALINFORMATION......................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT) ......................................................................................................................... 6 1.2.SUPPORTEQUIPMENTLIST..................................................................................................................................8 1.3EXTERNALI/OCABLE..................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page1of42FCCID:2AHZ5MPADReportNo.:LCSC05276013ED GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For ShenzhenHuafuruiTechnologyCo.,Ltd. Tablet TestModel:MegaPad AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ShenzhenHuafuruiTechnologyCo.,Ltd. Address: Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding,No. 993JiaxianRoad,XiangjiaotangCommunity,BantianStreet,Longgang District,Shenzhen,P.R.China Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:May27,2026 Numberoftestedsamples:2 SampleNo.:C260527005-1,C260527005-2 Serialnumber:Prototype DateofTest:May27,2026~July06,2026 DateofReport:July07,2026 Page2of42FCCID:2AHZ5MPADReportNo.:LCSC05276013ED GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15E(15.407) ReportReferenceNo......................:LCSC05276013ED DateofIssue.......................................:July07,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–¡ Otherstandardtestingmethodâ–¡ Applicant’sName.............................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address................................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China TestSpecification Standard..............................................:FCCCFR47PART15E(15.407) TestReportFormNo......................:TRF-4-E-146A/0 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:Tablet TradeMark..........................................:CUBOT TestModel...........................................:MegaPad Ratings.................................................:PleaseRefertoPage6 Result...................................................:Pass Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of42FCCID:2AHZ5MPADReportNo.:LCSC05276013ED GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT TestResult:Pass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC05276013ED July07,2026 Dateofissue EUT.........................................:Tablet TestModel...............................:MegaPad Applicant...............................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address..................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address...................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Factory...................................:ShenzhenHuafuruiTechnologyCo.,Ltd. Address...................................:Unit601-03,6/F,BlockA,Building1,GanfengTechnologyBuilding, No.993JiaxianRoad,XiangjiaotangCommunity,BantianStreet, LonggangDistrict,Shenzhen,P.R.China Telephone...............................:/ Fax..........................................:/ Page4of42FCCID:2AHZ5MPADReportNo.:LCSC05276013ED GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July07,2026InitialIssue--- Page5of42FCCID:2AHZ5MPADReportNo.:LCSC05276013ED GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT).........................................................................................................................6 1.2.SUPPORTEQUIPMENTLIST .................................................................................................................................. 8 1.3EXTERNALI/OCABLE..................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Appendix E RF Test Data for 5.8GWIFI (Conducted Measurement) Product Name: Tablet Test Model: MegaPad Environmental Conditions Temperature: 24.1ï‚°C Relative Humidity: 53.2% ATM Pressure: 100.0 kPa Test Engineer: Zhang hai Supervised by: Fengliu Tang Page 2 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com E.1 Min emission bandwidth Test Result B4 TestMode Antenna Freq (MHz) 6db EBW [MHz] FL[MHz] FH[MHz] Limit [MHz] Verdict 11A Ant1 5745 14.560 5737.720 5752.280 0.5 PASS 5785 13.840 5778.680 5792.520 0.5 PASS 5825 12.960 5818.360 5831.320 0.5 PASS 11N20SISO Ant1 5745 15.040 5737.480 5752.520 0.5 PASS 5785 15.040 5777.520 5792.560 0.5 PASS 5825 15.480 5817.080 5832.560 0.5 PASS 11N40SISO Ant1 5755 34.960 5737.560 5772.520 0.5 PASS 5795 33.760 5777.480 5811.240 0.5 PASS 11AC20SISO Ant1 5745 12.720 5738.720 5751.440 0.5 PASS 5785 16.240 5776.640 5792.880 0.5 PASS 5825 15.040 5817.520 5832.560 0.5 PASS 11AC40SISO Ant1 5755 35.040 5737.480 5772.520 0.5 PASS 5795 35.040 5777.480 5812.520 0.5 PASS 11AC80SISO Ant1 5775 73.920 5738.680 5812.600 0.5 PASS Page 3 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Test Graphs B4 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 Page 4 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 Page 5 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 Page 6 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 Page 7 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 Page 8 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 Page 9 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC80SISO_Ant1_5775 Page 10 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com E.2 Maximum conducted output power Test Result Channel Power Test Mode Antenna Freq (MHz) TPC Mode Measured Power [dBm] DC Factor [dB] Result [dBm] Limit [dBm] Verdict 11A Ant1 5745 NA 18.21 0.15 18.36 ≤30.00 PASS 5785 NA 18.19 0.12 18.31 ≤30.00 PASS 5825 NA 17.01 0.12 17.13 ≤30.00 PASS 11N20SISO Ant1 5745 NA 17.32 0.16 17.48 ≤30.00 PASS 5785 NA 17.04 0.13 17.17 ≤30.00 PASS 5825 NA 16.81 0.16 16.97 ≤30.00 PASS 11N40SISO Ant1 5755 NA 17.58 0.26 17.84 ≤30.00 PASS 5795 NA 17.40 0.26 17.66 ≤30.00 PASS 11AC20SISO Ant1 5745 NA 17.42 0.13 17.55 ≤30.00 PASS 5785 NA 18.02 0.13 18.15 ≤30.00 PASS 5825 NA 17.19 0.16 17.35 ≤30.00 PASS 11AC40SISO Ant1 5755 NA 16.98 0.26 17.24 ≤30.00 PASS 5795 NA 17.09 0.26 17.35 ≤30.00 PASS 11AC80SISO Ant1 5775 NA 16.70 0.50 17.20 ≤30.00 PASS Page 11 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com E.3 Maximum power spectral density Test Result TestMode Antenna Freq (MHz) Raw Data [dBm/MHz] DC Factor RBW Factor Result [dBm/MHz] Limit [dBm/MHz] Verdict 11A Ant1 5745 2.42 0.15 2.22 4.79 ≤30.00 PASS 5785 1.2 0.12 2.22 3.54 ≤30.00 PASS 5825 0.7 0.12 2.22 3.04 ≤30.00 PASS 11N20SISO Ant1 5745 0.13 0.16 2.22 2.51 ≤30.00 PASS 5785 0.31 0.13 2.22 2.66 ≤30.00 PASS 5825 0.29 0.16 2.22 2.67 ≤30.00 PASS 11N40SISO Ant1 5755 -2.35 0.26 2.22 0.13 ≤30.00 PASS 5795 -2.47 0.26 2.22 0.01 ≤30.00 PASS 11AC20SISO Ant1 5745 0.35 0.13 2.22 2.70 ≤30.00 PASS 5785 0.28 0.13 2.22 2.63 ≤30.00 PASS 5825 0.67 0.16 2.22 3.05 ≤30.00 PASS 11AC40SISO Ant1 5755 -2.69 0.26 2.22 -0.21 ≤30.00 PASS 5795 -2.53 0.26 2.22 -0.05 ≤30.00 PASS 11AC80SISO Ant1 5775 -6.49 0.50 2.22 -3.77 ≤30.00 PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.725−5.85 GHz. Page 12 of 39 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013EE Guangzhou LCS Compliance…

Text truncated - open the document above for the full version.

Test Report

Page 26 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N40SISO_Ant1_High_5230_Peak 11AC20SISO_Ant1_Low_5180_AV Page 27 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC20SISO_Ant1_Low_5180_Peak 11AC20SISO_Ant1_High_5240_AV Page 28 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC20SISO_Ant1_High_5240_Peak 11AC40SISO_Ant1_Low_5190_AV Page 29 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC40SISO_Ant1_Low_5190_Peak 11AC40SISO_Ant1_High_5230_AV Page 30 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC40SISO_Ant1_High_5230_Peak 11AC80SISO_Ant1_Low_5210_AV Page 31 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC80SISO_Ant1_Low_5210_Peak 11AC80SISO_Ant1_High_5210_AV Page 32 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11AC80SISO_Ant1_High_5210_Peak Page 33 of 45 FCC ID: 2AHZ5MPAD Report No.: LCSC05276013ED Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com D.5 Frequency Stability Test Result Voltage TestMode Antenna Freq (MHz) Voltage [Vdc] Temperature (°C) Deviation (Hz) Deviation (ppm) Limit (ppm) Verdict 11A Ant1 5180 NV NT 0.00 0.000000 20 PASS LV NT -20000.00 -3.861004 20 PASS HV NT -20000.00 -3.861004 20 PASS 5200 NV NT -20000.00 -3.846154 20 PASS LV NT -20000.00 -3.846154 20 PASS HV NT -20000.00 -3.846154 20 PASS 5240 NV NT 0.00 0.000000 20 PASS LV NT -20000.00 -3.816794 20 PASS HV NT -20000.00 -3.816794 20 PASS 11N20SISO Ant1 5180 NV NT -20000.00 -3.861004 20 PASS LV NT -20000.00 -3.861004 20 PASS HV NT 0.00 0.000000 20 PASS 5200 NV NT -20000.00 -3.846154 20 PASS LV NT 0.00 0.000000 20 PASS HV NT 0.00 0.000000 20 PASS 5240 NV NT 0.00 0.000000 20 PASS LV NT -20000.00 -3.816794 20 PASS HV NT -20000.00 -3.816794 20 PASS 11N40SISO Ant1 5190 NV NT -40000.00 -7.707129 20 PASS LV NT 0.00 0.000000 20 PASS HV NT 0.00 0.000000 20 PASS 5230 NV NT -40000.00 -7.648184 20 PASS LV NT 0.00 0.000000 20 PASS HV NT -40000.00 -7.648184 20 PASS 11AC20SISO Ant1 5180 NV NT -20000.00 -3.861004 20 PASS LV NT 0.00 0.000000 20 PASS HV NT 0.00 0.000000 20 PASS 5200 NV NT -20000.00 -3.846154 20 PASS LV NT -20000.00 -3.846154 20 PASS HV NT -20000.00 -3.846154 20 PASS 5240 NV NT 20000.00 3.816794 20 PASS LV NT -40000.00 -7.633588 20 PASS HV NT 0.00 0.000000 20 PASS 11AC40SISO Ant1 5190 NV NT 0.00 0.000000 20 PASS Pa…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Paul Liu
[email protected]Fax: 0755-23612065

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place Fullerton, · California, 92835 · United States

Test Firm

Guangzhou LCS Compliance Testing Laboratory LtdGavin Liang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz46.80 mW
215E5.75 GHz - 5.83 GHz68.50 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum average conducted output power. The device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes as described in this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission exposure conditions are 0.56 W/kg and 1.11 W/kg respectively. Device is a client only containing a 802.11a/n/ac configuration, enabled for 5 GHz band operations as described in this filing. The device also contains Bluetooth, BLE, 2.4GHz WLAN and GSM/WCDMA/LTE transmitters.