2AHZT-HORK02RUI Replacement Transmitter for HONDA

Remotes Unlimited Inc.
RUI Replacement Transmitter for HONDA - FCC ID 2AHZT-HORK02 - Remotes Unlimited Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 04, 2023
Application Purpose
Original Equipment
Date of Application
Jul 04, 2023
Equipment Note
RUI Replacement Transmitter for HONDA
Frequency Range
313.83100000 - 313.83100000
Company
Remotes Unlimited Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

The car is locked after you press“LOCK” button. The car is unlocked after you press“UNLOCK” button. The car begin to enter the panic state after you press“PANIC” button. USER MANUAL Three button The car is locked after you press“LOCK” button. The car is unlocked after you press“UNLOCK” button. The car begin to enter the panic state after you press“PANIC” button. The trunk is opened after you press“TRUNK” button. USER MANUAL Four button FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.

Attestation Statements

Remotes Unlimited Inc. 12999 Murphy Road Suite A Stafford Texas United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-7-5 U.S. Agent Designation Remotes Unlimited Inc. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2AHZT-HORK02): Name and company of U.S. agent: Remotes Unlimited Inc. Physical U.S. address of agent: 12999 Murphy Road Suite A Stafford Texas United States FRN of U.S. agent: 0025061466 Email address of U.S. agent: [email protected] Remotes Unlimited Inc. acknowledges their obligation to accept service of process on behalf of Remotes Unlimited Inc. . Remotes Unlimited Inc. with the FRN [0025061466] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Bruce Gillis Manager Remotes Unlimited Inc. Signature Bruce Gillis Manager Remotes Unlimited Inc. 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5

Cover Letter(s)

Sincerely, Name/Title: Bruce Gillis/Manager Company: Remotes Unlimited Inc. Address: 12999 Murphy Road Suite A Stafford Texas United States Phone: (281) 820-0300 Fax: (281) 495-5122 E-Mail: [email protected]

External Photos

Shenzhen HTT Technology Co., Ltd. Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 3 Product Name: RUI Replacement Transmitter for HONDA Model No.: Ho-RK-38 EUT Constructional Details External Photo Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 3 Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 3 of 3 ------End------

ID Label/Location Info

Label and Location Size: L: 1.0cm*W: 0.5cm Label and Location FCC ID : 2AHZT-HORK02

Internal Photos

Shenzhen HTT Technology Co., Ltd. Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 3 Product Name: RUI Replacement Transmitter for HONDA Model No.: Ho-RK-38 EUT Constructional Details Internal Photo Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 3 Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 3 of 3 ------End------

RF Exposure Info

RF Exposure evaluation FCC ID: 2AHZT-HORK02 1.1. Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 1.2. Requirement According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 1.3. Manufacturing tolerance Freq. (MHz) Field strength(max)(dBuV/m) EIRP (max) (dBm) Turn-up Power (dB) Max tune up power (dBm) [P] 313.831MHz 69.25 -26.01 -26.0±1 -25.0 Note: EIRP=E-104.8+20logD, D=3 Page 2 of 2 2. E v a l u a t i o n R e s u l t Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power (including tune-up tolerance) SAR Test Exclusion Threshold SAR Test Exclusion dBm mW SRD 0.315 5 -25.0 0.0032 0.0004<3.0 Yes 3. C o n c l u s i o n The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06 .....................End of Report.........................

Test Report

1. Antenna Description: Antenna type PCB antenna Model Ho-RK-38 Frequency range 313-315MHz Manufacturer SHENZHEN VORAUS TECH CO.,LTD ANT Peak Gain 2.0 dBi 2. Antenna Photo:

Test Report

Shenzhen HTT Technology Co., Ltd. FCC PART 15 SUBPART C TEST REPORT FCC PART 15.231 Report Reference No. ..................... : FCC ID. ........................................... : HTT202306311F01 2AHZT-HORK02 Compiled by ( position+printed name+signature) .. : File administrators Supervised by ( position+printed name+signature) .. : Project Engineer Approved by ( position+printed name+signature) .. : RF Manager Date of issue ..................................... : Jun.20,2023 Testing Laboratory Name .............: Shenzhen HTT Technology Co.,Ltd. Address ............................................ : 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao’an District, Shenzhen, Guangdong, China Applicant’s name ............................ : Remotes Unlimited Inc. Address ............................................ : 12999 Murphy Road, Suite A, Stafford, TX 77477, USA Test specification ...........................: Standard ........................................... : FCC Part 15.231 Shenzhen HTT Technology Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HTT Technology Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HTT Technology Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : RUI Replacement Transmitter for HONDA Trade Mark ....................................... : Remotes Unlimited Manufacturer .................................... : SHENZHEN VORAUS TECH CO.,LTD Model/Type reference....................... : Ho-RK-38 Listed Models .................................. : Ho-RK-37 Ratings ............................................. : DC 3.0V From Battery Modulation ....................................... : ASK Frequency .......................................... 313.8310MHz Result................................................ : PASS Report No.: HTT202306311F01 Page 2 of 17 T E S T R E P O R T Equipment under Test : RUI Replacement Transmitter for HONDA Model /Type : Ho-RK-38 Listed Models : Ho-RK-37 Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested. Applicant : Remotes Unlimited Inc. Address : 12999 Murphy Road, Suite A, Stafford, TX 77477, USA Manufacturer : SHENZHEN VORAUS TECH CO.,LTD Address : Room 1801, 18th Floor, Building T1, Hi Park, Luozu Community, Shiyan Subdistrict, Baoan District, Shenzhen, Guangdong, 518108, P.R.China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: HTT202306311F01 Page 3 of 17 Contents 1 T E S T S T A N D A R D S .................................................................. 4 2 S U M M A R Y ............................................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 Block Diagram of Test Setup 5 2.6 Special Accessories 5 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T ............................................................... 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ............................................ 10 4.1 AC Power Conducted Emission 10 4.2 Radiated Emission 11 4.3 20dB Bandwidth 14 4.4 Deactivation Time 15 4.5 Antenna Requirement 16 5 T E S T S E T U P P H O T O S O F T H E E U T .......................................... 17 6 P H O T O S O F T H E E U T ............................................................. 17 Report No.: HTT202306311F01 Page 4 of 17 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.231:Periodic operation in the band 40.66-40.70 MHz and above 70 MHz. ANSI C63.10:2013 : American National Standard for Testing Unlicensed Wireless Devices Report No.: HTT202306311F01 Page 5 of 17 2 S U MM A R Y 2.1 General Remarks Date of receipt of test sample : Jun.14,2023 Testing commenced on : Jun.14,2023 Testing concluded on : Jun.20,2023 2.2 Product Description Product Name: RUI Replacement Transmitter for HONDA Model/Type reference: Ho-RK-38 Testing sample ID: HTT202306311-1# (Engineer sample), HTT202306311-2#(Normal sample) Power supply: DC 3.0V From Battery Modulation: ASK Operation frequency: 313.831MHz Channel number: 1 Antenna type: PCB antenna Antenna gain: 2.0 dBi 2.3 Equipment Under Test Power supply system utilised Power supply voltage : ○ 230V / 50 Hz ○ 120V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 3.0V From Battery 2.4 Short description of the Equipment under Test (EUT) This is a RUI Replacement Transmitter for HONDA. For more details, refer to the user’s manual of the EUT. 2.5 Block Diagram of Test Setup 2.6 Special Accessories Follow auxiliary equipment(s) test with EUT that provided by the manufacturer or laboratory is listed as follow: Description Manufacturer Model Technical Parameters Certificate Provided by / / / / / / / / / / / / EUT Report No.: HTT202306311F01 Page 6 of 17 2.7 Related Submittal(s) / Grant (s) This submittal(s) (test report) is intended for the device filing to comply with Section 15.231 of the FCC Part 15, Subpart C Rules. 2.8 Modifications No modifications were implemented to meet testing criteria. Report No.: HTT202306311F01 Page 7 of 17 3 T E S T E N V I R O N M E N T 3.1 Address of the test laboratory Shenzhen HTT Technology Co.,…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen HTT Technology Co., Ltd. Report No.: HTT202306311 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 1 Product Name: RUI Replacement Transmitter for HONDA Model No.: Ho-RK-38 Test Setup Photo Radiated Emission ------End------

Contact Information

Applicant

Bruce Gillis(Manager)
[email protected]281-820-0300Fax: 281-495-5122

Test Firm

Shenzhen HTT Technology Co.,Ltd.Kevin Yang
[email protected]86-755-23595200

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231313.831 MHz - 313.831 MHz-
Confidentiality