2AI5IMTC2Charger

Apption Labs Limited
Charger - FCC ID 2AI5IMTC2 - Apption Labs Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 01, 2023
Application Purpose
Original Equipment
Date of Application
Oct 31, 2023
Equipment Note
Charger
Frequency Range
2402.00000000 - 2480.00000000
Company
Apption Labs Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Apption Labs Limited 66 Commercial Square, Leicester, LE2 7SR United Kingdom Attestation Statements Date: 2023/10/27 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Attestation Statements Part 2.911(d)(5)(i)-(ii) Filing FCC ID:2AI5IMTC2 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Apption Labs L imited (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. S tatement for 47 CFR section 2.911(d)(5)(ii) Apption Labs L imited (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. R espectfully, Applicant’s company name : Apption Labs Limited Applicant’s company address : 66 Commercial Square, Leicester, LE2 7SR United Kingdom Signature : Name and Job Title : Teemu Nivala / Managing Director E- Mail : [email protected] Te l : (+44) 1162184183 Fax : N/A

Attestation Statements

Apption Labs Limited 66 Commercial Square, Leicester, LE2 7SR United Kingdom Attestation Statements Date: 2023/10/27 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Attestation Statements Part 2.911(d)(5)(i)-(ii) Filing FCC ID:2AI5IMTC2 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Apption Labs L imited (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. S tatement for 47 CFR section 2.911(d)(5)(ii) Apption Labs L imited (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. R espectfully, Applicant’s company name : Apption Labs Limited Applicant’s company address : 66 Commercial Square, Leicester, LE2 7SR United Kingdom Signature : Name and Job Title : Teemu Nivala / Managing Director E- Mail : [email protected] Te l : (+44) 1162184183 Fax : N/A

Attestation Statements

Apption Labs Limited 66 Commercial Square, Leicester, LE2 7SR United Kingdom U.S. Agent for Service of Process Attestation Date: 2023/10/27 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia MD 21046 USA Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: 2AI5I Applicant FRN:0025738857 To Whom It May Concern: Apption Labs Limited (“the applicant”) certifies that, as of the date of the filing of the application, Apption Labs Inc. - USA office is our designated U.S. agent for service of process for the above referenced Gantee code. Apption Labs Limited accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Apption Labs Inc. - USA office accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced Gantee code. Designated U.S. Agent Information: Name: Apption Labs Inc. - USA office Address: 3779 Cahuenga Blvd. Studio City, CA 91604, US Contact Person: Farrell Coleman Te l . : 1- 310-871-2107 Email: [email protected] Sincerely, Applicant Designated U.S. Agent Company Name : Apption Labs Limited Company Name : Apption Labs Inc. - USA office Company Address : 66 Commercial Square, Leicester, LE2 7SR United Kingdom Company Address : 3779 Cahuenga Blvd. Studio City, CA 91604, US Signature : Signature : Name : Teemu Nivala Name : Farrell Coleman E- Mail : [email protected] E- Mail : [email protected] Te l : (+44) 1162184183 Te l : 1-310-871-2107

Cover Letter(s)

Apption Labs Limited 66 Commercial Square, Leicester, LE2 7SR United Kingdom Confidential Letter Date: 2023/10/27 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID:2AI5IMTC2 To Whom It May Concern: Long Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby respectfully request confidential treatment of information accompanying this application as outlined below: ● Block Diagrams ● Schematics ● Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We understand that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Short Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby respectfully request short-term confidential treatment of information accompanying this application as outlined below until 180 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: ● External Photos ● Internal Photos ● Test Setup photos ● Users Manuals Respectfully, Applicant’s company name : Apption Labs Limited Applicant’s company address : 66 Commercial Square, Leicester, LE2 7SR United Kingdom Signature : Name and Job Title : Teemu Nivala / Managing Director E- Mail : [email protected] Te l : (+44) 1162184183 Fax : N/A

Cover Letter(s)

Apption Labs Limited 66 Commercial Square, Leicester, LE2 7SR United Kingdom Power of Attorney Date: 2023/10/27 Dear Sir, I hereby have entrusted the following person to be a proxy regarding application for Type Certification. Sporton International Inc. Hsinchu Laboratory Address : No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C. Name : Leo Huang Job Title : Manager e- mail : [email protected] I am therefore responsible for the contents of the application. FCC ID: 2AI5IMTC2 Respectfully, Applicant’s company name : Apption Labs Limited Applicant’s company address : 66 Commercial Square, Leicester, LE2 7SR United Kingdom Signature : Name and Job Title : Teemu Nivala / Managing Director E- Mail : [email protected] Te l : (+44)1162184183 Fax : N/A

External Photos

PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 1 of 4 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP Brand Name: MEATER Model Name: MT-CP20 PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 2 of 4 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 3 of 4 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 4 of 4 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP Battery

ID Label/Location Info

Label and location (back of the device)

Internal Photos

PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 1 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP Brand Name: MEATER Model Name: MT-CP20 PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 2 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 3 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP Ant.1 PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 4 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 5 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 6 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP PHOTOGRAPHS OF EUT Report No. : EP333083-01 Sporton International Inc. Hsinchu Laboratory Page Number : 7 of 7 TEL : 886-3-656-9065 Issued Date : Oct. 25, 2023 FAX : 886-3-656-9085 EP Report Version : 01 Report Template No.: CB Ver1.1_EP

RF Exposure Info

RADIO EXPOSURE TEST REPORT Report No. : FA333083-01 TEL : 886-3-656-9065 Page Number : 2 of 8 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A1_1 Ver1.1 Report Version : 01 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ............................................................................................................................. 5 1.1 EUT General Information ....................................................................................................................... 5 1.2 Antenna Information ............................................................................................................................... 5 1.3 Accessories ............................................................................................................................................ 5 1.4 Applicable Standards ............................................................................................................................. 5 1.5 Testing Location ..................................................................................................................................... 5 2 Maximum Permissible Exposure ........................................................................................................ 6 2.1 Limit of Maximum Permissible Exposure ............................................................................................... 6 2.2 MPE Calculation Method ........................................................................................................................ 6 2.3 MPE Exemption ...................................................................................................................................... 7 2.4 Calculated Result and Limit .................................................................................................................... 8 Photographs of EUT v01 RADIO EXPOSURE TEST REPORT Report No. : FA333083-01 TEL : 886-3-656-9065 Page Number : 3 of 8 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A1_1 Ver1.1 Report Version : 01 History of this test report Report No. Version Description Issued Date FA333083-01 01 Initial issue of report Oct. 25, 2023 RADIO EXPOSURE TEST REPORT Report No. : FA333083-01 TEL : 886-3-656-9065 Page Number : 4 of 8 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A1_1 Ver1.1 Report Version : 01 Summary of Test Result Report Clause Ref Std. Clause Test Items Result (PASS/FAIL) Remark 2 - Exposure evaluation PA SS - Note: Reference to Sporton Project No.: 333083 Conformity Assessment Condition: 1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account. 2. The measurement uncertainty please refer to each test result in the chapter "Measurement Uncertainty". Disclaimer: The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity. Reviewed by: Sam Chen Report Producer: Sandy Chuang RADIO EXPOSURE TEST REPORT Report No. : FA333083-01 TEL : 886-3-656-9065 Page Number : 5 of 8 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A1_1 Ver1.1 Report Version : 01 1 General Description 1.1 EUT General Information RF General Information Evaluation Mode Frequency Range (MHz) Operating Frequency (MHz) Modulation Type Bluetooth 2400-2483.5 2402-2480 LE: GFSK 1.2 Antenna Information Ant. Port Brand Model Name Antenna Type Connector Gain (dBi) 1 1 VORWERK T-TSNC PCB Antenna N/A 2 Note1: The above information was declared by manufacturer. Note2: For Bluetooth function (1TX, 1RX): Only Port 1 can be used as transmitting/receiving functions. 1.3 Accessories Accessories Battery*1 1.4 Applicable Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 2.1091  KDB 447498 D04 Interim General RF Exposure Guidance v01 The following reference test guidance is not within the scope of accreditation of TAF.  47 CFR Part 1.1307  47 CFR Part 1.1310 1.5 Testing Location Testing Location Information Test Lab.:Sporton International Inc. Hsinchu Laboratory Hsinchu ADD: No.8, Ln. 724, Bo’ai St., Zhubei City, Hsinchu County 302010, Taiwan (R.O.C.) (TAF: 3787) TEL: 886-3-656-9065 FAX: 886-3-656-9085 Test site Designation No. TW3787 with FCC. Conformity Assessment Body Identifier (CABID) TW3787 with ISED. RADIO EXPOSURE TEST REPORT Report No. : FA333083-01 TEL : 886-3-656-9065 Page Number : 6 of 8 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A1_1 Ver1.1 Report Version : 01 2 Maximum Permissible Exposure 2.1 Limit of Maximum Permissible Exposure (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 *(100) <6 3.0-30 1842/f 4.89/f *(900/f 2 ) <6 30-300 61.4 0.163 1.0 <6 300-1500 - - f/300 <6 1500-100,000 - - 5 <6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1500 - - f/1500 <30 1500-1…

Text truncated - open the document above for the full version.

Test Report

Brand: Vorwerk Model name: T-TSNC PCB Antenna Antenna Gain: 2dBi Manufacturer: AboCom Systems, Inc. Manufacturer Address: No. 77, Yu-Yih Rd, Chu-Nan Chen, Miao-Lih Hsuan,Taiwan, R.O.C. E-Plane EѲ Eф H-Plane EѲ Eф

Test Report

RADIO TEST REPORT Report No. : FR333083-01 TEL : 886-3-656-9065 Page Number : 2 of 23 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A10_6 Ver1.3 Report Version : 01 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ............................................................................................................................. 5 1.1 Information .............................................................................................................................................. 5 1.2 Applicable Standards ............................................................................................................................. 6 1.3 Testing Location Information .................................................................................................................. 6 1.4 Measurement Uncertainty ...................................................................................................................... 6 2 Test Configuration of EUT ................................................................................................................... 7 2.1 Test Channel Mode ................................................................................................................................ 7 2.2 The Worst Case Measurement Configuration ........................................................................................ 7 2.3 EUT Operation during Test .................................................................................................................... 7 2.4 Accessories ............................................................................................................................................ 8 2.5 Support Equipment ................................................................................................................................. 8 2.6 Test Setup Diagram ............................................................................................................................... 9 3 Transmitter Test Result ..................................................................................................................... 11 3.1 DTS Bandwidth..................................................................................................................................... 11 3.2 Maximum Conducted Output Power .................................................................................................... 12 3.3 Power Spectral Density ........................................................................................................................ 15 3.4 Emissions in Non-restricted Frequency Bands .................................................................................... 17 3.5 Emissions in Restricted Frequency Bands ........................................................................................... 18 4 Test Equipment and Calibration Data .............................................................................................. 22 Appendix A. Test Results of DTS Bandwidth Appendix B. Test Results of Maximum Conducted Output Power Appendix C. Test Results of Power Spectral Density Appendix D. Test Results of Emissions in Non-restricted Frequency Bands Appendix E. Test Results of Emissions in Restricted Frequency Bands Appendix F. Test Photos Photographs of EUT v01 RADIO TEST REPORT Report No. : FR333083-01 TEL : 886-3-656-9065 Page Number : 3 of 23 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A10_6 Ver1.3 Report Version : 01 History of this test report Report No. Version Description Issued Date FR333083-01 01 Initial issue of report Oct. 25, 2023 RADIO TEST REPORT Report No. : FR333083-01 TEL : 886-3-656-9065 Page Number : 4 of 23 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A10_6 Ver1.3 Report Version : 01 Summary of Test Result Report Clause Ref Std. Clause Test Items Result (PASS/FAIL) Remark 1.1.2 15.203 Antenna Requirement PA SS - - 15.207 AC Power-line Conducted Emissions N/A Note 1 3.1 15.247(a) DTS Bandwidth PA SS - 3.2 15.247(b) Maximum Conducted Output Power PA SS - 3.3 15.247(e) Power Spectral Density PA SS - 3.4 15.247(d) Emissions in Non-restricted Frequency Bands PA SS - 3.5 15.247(d) Emissions in Restricted Frequency Bands PA SS - Note 1: The EUT was powered by battery; it’s not necessary to apply to AC Power Port Conducted Emission test. Note 2: Reference to Sporton Project No.: 333083 (After evaluating, related test items have been verified, and the original test data is replaced.) Conformity Assessment Condition: 1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account. 2. The measurement uncertainty please refer to each test result in the chapter "Measurement Uncertainty". Disclaimer: The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity. Reviewed by: Sam Chen Report Producer: Sandy Chuang RADIO TEST REPORT Report No. : FR333083-01 TEL : 886-3-656-9065 Page Number : 5 of 23 FAX : 886-3-656-9085 Issued Date : Oct. 25, 2023 Report Template No.: CB-A10_6 Ver1.3 Report Version : 01 1 General Description 1.1 Information 1.1.1 RF General Information Frequency Range (MHz) Bluetooth Mode Ch. Frequency (MHz) Channel Number 2400-2483.5 LE 2402-2480 0-39 [40] Band Mode BWch (MHz) N…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Photos Appendix F Sporton International Inc. Hsinchu Laboratory Page No. : 1 of 2 1. Photographs of Radiated Emissions Test Configuration Test Configuration: 30MHz~1GHz FRONT VIEW REAR VIEW Report No. : FR333083-01 Test Photos Appendix F Sporton International Inc. Hsinchu Laboratory Page No. : 2 of 2 Test Configuration: Above 1GHz FRONT VIEW REAR VIEW ─────THE END───── Report No. : FR333083-01

Contact Information

Applicant

Farrell Coleman
[email protected](+44)1162184183Fax: -

Test Firm

Sporton International Inc. Hsinchu LaboratoryAlex Chen
[email protected]+886-3-327-3456Fax: +886-3-327-0978

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antennas use for this device must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Apption Labs Limited

2AI5IMTX2

MEATER PRO XL

Dec 03, 2024

Equipment Class

DTS - Digital Transmission System