GuangzhouHavitTechnologyCo.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:November29,2024 FCCID:2AI6I-FUXIH7D Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing GuangzhouHavitTechnologyCo.,LTDcertifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorization pursuanttosection2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing GuangzhouHavitTechnologyCo.,LTDcertifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing “covered”equipment. Applicant:GuangzhouHavitTechnologyCo.,LTD Address:ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG,China ContactPerson:YangWei Tel.:+86-20-66820279 Email:[email protected] Sincerely, Signature:
GuangzhouHavitTechnologyCo.,LTD Address:ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADECENTER, NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG,China FRN:0025744657 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AI6I-FUXIH7D GuangzhouHavitTechnologyCo.,LTD.certifiesthat,asofthedateofthefilingofthe application,ClevelandInternationalTradeAgency.isourdesignatedU.S.agentforserviceof processfortheabovereferencedFCCID.GuangzhouHavitTechnologyCo.,LTDacceptsto maintainanagentfornolessthanoneyearafterthegranteehasterminatedallmarketing andimportationortheconclusionofanyCommission-relatedproceedinginvolvingthe equipment. ClevelandInternationalTradeAgencyaccepts,asofthedateofthefilingoftheapplication, theobligationofthedesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID. DesignatedU.S.AgentInformation: Name:ClevelandInternationalTradeAgency Address:4033StClairAve,Cleveland,OH44103,USA ContactPerson:BeckyDeng Tel.:216-600-0606 Email:[email protected] FRN:0033401837 Sincerely, SignedonbehalfofGuangzhouHavit TechnologyCo.,LTD SignedonbehalfofClevelandInternational TradeAgency Signature Signature Name:YangWei Name:BeckyDeng Title: Manager Title:Manager Date:November29,2024Date:November29,2024
___________________________________________________________________________________________________________ 第 3 页共 8 页 Antenna Application: WLAN,802.11b/g,Bluetooth,etc... Features SMD,highreliability,ultraImpact,Omni-directional... Partnumber AAN5012H1R2G45 (1)(2)(3)(4)(5) (1)ProductTypeChipAntenna (2)SizeCode 5.0x1.2mm (3)TypeCodeH1 (4)Packing Tapeandreel (5)Frequency2.45GHz ElectricalSpecification WorkingFrequencyRange2400~2484MHz PeakGain2.85dBi(Typ.) Impedance 50Ohm Returnloss 10dB(Min) PolarizationLinear AzimuthBeamwidth Omni-directional OperationTemperature(°C)-40~85°C ThespecificationisdefinedonEVB. DimensionandTerminalConfiguration Dimension(mm) L 5.0+-0.20 No.TerminalName W 1.20+-0.20 1 Feeding 2Soldering T 1.20+-0.20 A 0.20+-0.20 第 4 页共 8 页 2.4GHz2.45HHzChipAntenna:AAN5012H1R2G45 EvaluationBoardReference PCBDimension&AntennaLayoutReference unit:mm ElectricalCharacteristics ReturnLoss&Radiation ReturnLoss Frequency (MHz) S11(dB) 2400-12.8 2442-19.8 2484-11.9 Radiation 2.45GHz Frequency2445MHz Peakgain2.85dBi Efficiency 78.5% 第 5 页共 8 页 2.4GHz2.45HHzChipAntenna:AAN5012H1R2G45 TapingSpecifications ReelTapingBlisterTape Checkingnote Index Spec(mm) Internaldiameterofreel A 60.20 ± 0.50 Externaldiameterof reel B 178 ± 1.00 Quantity/perreel2000pcs Tapematerial Plastic (embossed) Checkingnote Index Spec(mm) Sprockethole D01.50+0.10/-0.00 Distancesprocketholetooutside E1 1.75±0.10 Distancesprocketholetopocket F 5.50±0.05 Distancesprocketholeto sprockethole P0 4.00±0.10 Distancepockettopocket P1 4.00±0.10 Distancesprocketholetopocket P2 2.00±0.05 Tapewidth W12.00+0.30/-0.10 Pocketwidthnominalclearance A0 2.28 ± 0.13 Pocketlengthnominalclearance B0 5.70 ± 0.13 Pocketdepthminimumclearance K0 1.58±0.10 Thicknessoftape T 0.23±0.02 第 6 页共 8 页 2.4GHz2.45HHzChipAntenna:AAN5012H1R2G45 ReliabilityTable TestItem Procedure Requirements CeramicType Remark (Reference) Electrical Characterization Fulfilltheelectrical specification UserSpec. Thermal1.Preconditioning:NoVisibleDamage.MIL-STD-202 Shock 50±10°C/1hr,thenkeepfor24±1hrsatroomtemp. 2.Initialmeasure:Spec:referInitialspec. 3.Rapidchangeoftemperaturetest: -30°Cto+85°C;100cycles; Fulfilltheelectrical specification. 107 15minutesatLowercategorytemperature; 15minutesatUppercategorytemperature. Temperature Cycling 1.Initialmeasure:Spec:referInitialspec. 2.100Cycles(-30 °C to+85 °C ),SoakMode=1(2Cycle/hours). 3.Measurementat24±2Hoursaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. JESD22 JA104 HighTemperature Exposure 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered;500hours@T=+85 °C . 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 LowTemperature Storage 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered:500hours@T=-30°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 Solderability (SMDBottomSide) Dippingmethod: a.Temperature:235±5°C b.Dippingtime:3±0.5s Thesoldershouldcover over95%ofthecritical areaofbottomside. IEC60384-21/22 4.10 SolderingHeat Resistance (RSH) Preheatingtemperature:150±10°C. Preheatingtime:1~2min. Soldertemperature:260±5°C. Dippingtime:5±0.5s NoVisibleDamage. IEC60384-21/22 4.10 Vibration5g'sfor20min.,12cycleseachof3orientations Note:Use8"X5"PCB.031"thick7securepointson,onelong sideand2securepointsatcornersofoppositesides.Parts mountedwithin2"fromanysecurepoint.Testfrom10-2000 Hz. NoVisibleDamage. MIL-STD-202 Method204 Mechanical Shock Threeshocksineachdirectionshallbeappliedalongthethree mutuallyperpendicularaxesofthetestspecimen(18shocks) Peakvalue:1,500g’s Duration:0.5ms Velocitychange:15.4ft/s Waveform:Half-sine NoVisibleDamage. MIL-STD-202 Method213 Humidity Bias 1.Humidity:85%R.H.,Temperature:85±2°C. 2.Time:500±24hours. 3.Measurementat24±2hrsaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 Method106 第7页共8页 Boar d Flex (SMD) 1.Mountingmethod: IR-Reflow.PCBSize(L:100×W:40×T:1.6mm) 2.Applytheloadindirectionofthearrowuntilbendingreaches NoVisibleDamage. AEC-Q200 005 2mm. Adhesion Forceof1.8Kgfor60seconds.NoVisibleDamage Magnificationof20Xor greatermaybeemployed forinspectionofthe mechanicalintegrityofthe devicebodyterminalsand body/terminaljunction. AEC-Q200 006 PhysicalAnyapplicablemethodusingx10magnification,micrometers,InaccordancewithJESD22 Dimension calipers,gauges,contourprojectors,orothermeasuring equipment,capableofdeterminingtheactualspecimen dimensions. specification. JB100 RevisionHistory RevisionDate Content 1 2019/7/20 Newissue TXAntennaPicture: 第8页共8页 Manufacturerinformation Companyname:ShenzhenXiisoundTechnologyCo.,Ltd. Address:803,Building2,COFCOBusinessPark,XingdongCommunity 67,Xin'anStreet,Bao'anDistrict,Shenzhen
EffectiveDate:April2,2020QSF7.6.4-8–AgentAuthorizationLetterTemplatePage1of1 RevisionDate:Revision:0 GuangzhouHavitTechnologyCo.,LTD Date:November29,2024 ProductModelNumber:Fuxi-H7 FCCID:2AI6I-FUXIH7D Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd..isallowedtoforwardallinformationrelatedtothe approvalprojecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscuss anyissuesconcerningtheapprovalapplication.AnyandallactscarriedoutbyQAI LaboratoriesLtd..onourbehalfshallhavethesameeffectasactsofourown. By:YangWei ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+86-20-66820279 Onbehalfof:GuangzhouHavitTechnologyCo.,LTD
GuangzhouHavitTechnologyCo.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:November29,2024 Subject;RequestforConfidentiality FCCID:2AI6I-FUXIH7D ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:YangWei Title:Manager
Externalphotos FCCID:2AI6I-FUXIH7D
Internalphotos FCCID:2AI6I-FUXIH7D ANT
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20241102345E-02 Applicant: GuangzhouHavitTechnologyCo.,LTD AddressofApplicant: ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG,China EquipmentUnderTest(EUT): EUTName: 2.4GTransmitter TestModelNo.:Fuxi-H7 ModelNo.:Fuxi-H7 BrandName: HAVIT FCCID: 2AI6I-FUXIH7D Standards: 47CFRPart1.1307 47CFRPart2.1093 447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2024-11-07 DateofTest: 2024-11-07to2024-11-20 DateofIssue:2024-11-22 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (AlexWang) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-02 Page:2of7 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20241102345E-02Rev.01 Initialreport 2024-11-22 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-02 Page:3of7 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOF2.4GCUSTOM.....................................................................................................................4 4SAREVALUATION...........................................................................................................................................................5 4.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.1.3EUTRFExposure..............................................................................................................................................7 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-02 Page:4of7 3GeneralInformation 3.1ClientInformation Applicant: GuangzhouHavitTechnologyCo.,LTD AddressofApplicant: ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG, China Manufacturer: GuangzhouHavitTechnologyCo.,LTD AddressofManufacturer: ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG, China Factory: GuangzhouHavitTechnologyCo.,LTD AddressofFactory: ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG, China 3.2GeneralDescriptionofEUT ProductName: 2.4GTransmitter ModelNo.: Fuxi-H7 TestModelNo Fuxi-H7 TradeMark: HAVIT EUTSupportsRadiosapplication:2404MHz-2477MHz SoftwareVersion: Xii166_TX_TWS(Fuxi_H7_LEVEL15)_V47.bin&GP100_ TWSDSP240729NTCAACNOUARTNOSNIFF_V29_GP100 _0x010024180731_240730_crc(20240730111538684).bin HardwareVersion: GP081-TX-TYPE-C-V1.0-240326&GP100-RX-V1.4-240412 SampleType: MobilePortable EUTPowerSupply: PowersupplyDC5Vformcomputer 3.3GeneralDescriptionof2.4Gcustom OperationFrequency: 2404MHz-2477MHz ModulationTechnique: NonFrequencyHoppingSpreadSpectrum(NFHSS) ModulationType: GFSK NumberofChannel: 41 TestSoftwareofEUT: Form1 AntennaType:Chipantenna AntennaGain:2.85dBi ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-02 Page:5of7 4SAREvaluation 4.1RFExposureComplianceRequirement 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataas representativeofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttest positions(e.g.body,head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.This testreductionprocessprovidesfortheuseoftestdataforonespecificchannel,whilereferencingto thosedatafordemonstratingcomplianceinotherrequiredchannelsforeachtestpositionofan exposurecondition,withintheoperatingmodeofafrequencyband.Thisislimitedspecificallytowhen thereported1-gor10-gSARforthemid-bandorhighestoutputpowerchannelmeetsanyofthe followingconditions. 4.1.2Limits SAR-basedthresholdsarederivedbasedonfrequency,power,andseparationdistanceoftheRF source.Theformuladefinesthethresholdsingeneralforeitheravailablemaximumtime averaged powerormaximumtime-averagedERP,whicheverisgreater. IftheERPofadeviceisnoteasilydetermined,suchasforaportabledevicewithasmallform factor,theapplicantmayusetheavailablemaximumtime-averagedpowerexclusivelyifthe devi…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ20241102345E-01 Applicant: GuangzhouHavitTechnologyCo.,LTD AddressofApplicant: ROOM1307,13F,PHASE2B,CBUILDINGOFPOLYWORLDTRADE CENTER,NO.1000,XINGANGEASTROAD,HAIZHU,GUANGDONG,China EquipmentUnderTest(EUT): EUTName: 2.4GTransmitter ModelNo.:Fuxi-H7 TestModelNo.:Fuxi-H7 BrandName: HAVIT FCCID: 2AI6I-FUXIH7D Standards: 47CFRPart15,SubpartCSection15.249 DateofReceipt:2024-11-07 DateofTest: 2024-11-07to2024-11-20 DateofIssue:2024-11-22 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (AlexWang) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-01 Page:2of32 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20241102345E-01Rev.01 Initialreport 2024-11-22 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-01 Page:3of32 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203 ANSIC63.10(2013)PASS ACPowerLine ConductedEmission 47CFRPart15,SubpartCSection 15.207 ANSIC63.10(2013)PASS FieldStrengthofthe FundamentalSignal 47CFRPart15,SubpartCSection 15.249(a) ANSIC63.10(2013)PASS SpuriousEmissions 47CFRPart15,SubpartCSection 15.249(a)/15.209 ANSIC63.10(2013)PASS Restrictedbands aroundfundamental frequency(Radiated Emission) 47CFRPart15,SubpartCSection 15.249(a)/15.205 ANSIC63.10(2013)PASS 20dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.215(c) ANSIC63.10(2013)PASS ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20241102345E-01 Page:4of32 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT................................................................................................................................5 4.3TESTENVIRONMENTANDMODE................................................................................................................................7 4.4DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................7 4.5STATEMENTOFTHEMEASUREMENTUNCERTAINTY...................................................................................................8 4.6TESTLOCATION..........................................................................................................................................................9 4.7TESTFACILITY............................................................................................................................................................9 4.8DEVIATIONFROMSTANDARDS...................................................................................................................................9 4.9ABNORMALITIESFROMSTANDARDCONDITIONS.......................................................................................................9 4.10OTHERINFORMATIONREQUESTEDBYTHECUSTOMER...........................................................................................9 4.11EQUIPMENTLIST....................................................................................................................................................10 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................11 5.1ANTENNAREQUIREMENT.........................................................................................................................................11 5.2CONDUCTEDEMISSIONS...........................................................................................................................................12 5.3RADIATEDEMISSION................................................................................................................................................15 5.420DBBANDWIDTH....................................................................................................................................................23 6PHOTOGRAPHS...........................................................................................................................................................26 6.1RADIATEDEMISSIONTESTSETUP............................................................................................................................26 6.2CONDUCTEDEMISSIONTESTSETUP.........................................................................................................................27 6.3EUTCONSTRUCTIONALDETAILS.............................................................................................................................28 ***ENDOFREPORT***..............................................................................…
Text truncated - open the document above for the full version.
Setupphotos FCCID:2AI6I-FUXIH7D 1Photographs 1.1RadiatedEmissionTestSetup 9kHz~30MHz 30MHz~1GHz: Above1GHz: 1.2ConductedEmissionTestSetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

TWS EARBUDS
Equipment Class
DTS - Digital Transmission System
TWS EARBUDS
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
POWER BANK
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
WIRELESS SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Adaptive Hybrid Noise Cancelling TWS Earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter