FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. All Best Technology Limited/
  3. 2AIEGV2

2AIEGV2Alarm Clock with Bed Shaker

All Best Technology Limited
Alarm Clock with Bed Shaker - FCC ID 2AIEGV2 - All Best Technology Limited
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 18, 2020
Application Purpose
Original Equipment
Date of Application
Mar 18, 2020
Equipment Note
Alarm Clock with Bed Shaker
Frequency Range
433.92000000 - 433.92000000
Company
All Best Technology Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

104 mm V2(Homtime)黑/白 2020-03-11 英文说明书 120g道林纸 正反面+风琴折 A0发行A0版图档 142.5 mm side 1 side 2 #Please strictly follow above safety instructions, otherwise it may lead to short circuit, electric shock, fire and other malfunction. #If the product is not functioning properly. Please contact our technical support team or the s authorized service provider This product is precise. Please do not store and use under the following conditions: . Vibrate or shocking place. . Direct sunlight or high temperature place. . Wet and flooded place. . Dusty place. . Strong electromagnetic waves and electromagnetic force place. . Strong static place. . in the condition of moisture. . Close to the radiator, electric heater,or heat generating device. . Applicable only for in areas below 2000m above sea level. . Applicable only for non - tropical climates. #Please do not step on the product and the cord. #Please consult your distributor if you have any questions regarding the installation, operation and safety of this product, Honored customer, thank you for purchasing our product. Please read this manual carefully before using this product. - 3 - V2 Alarm Clock with Bed Shaker TIPS / IMPORTANT: All safety and operation instructions should be read thoroughly before proceeding and please keep the handbook for future reference. - 2 - WARNING IF YOU IGNORE SAFETY INSTRUCTIONS, ERROR MANIPUL- ATION MAY CAUSE DAMAGE TO PERSONS AND PRODUCTS. Safety Instructions Read all safety instructions before using this product: Please read this manual carefully including safety instructions, parts instruction and operation manual before using this product. . Install the product strictly according to this operation manual. . Use only with Homtime-recommended attachments, accessories, and replacement parts. . Please do not open the decomposition of the product. . Please use the original power cord . . Please do not place items on the product and cord, Please do not bend, cut off or process the cord. Please do not use with a damaged cord or plug. . Before cleaning the product, please disconnect the power supply first and clean the product with dry cloth. . Suitable for dry locations only. . Do not use outdoors or on wet surfaces. Never locate the product where it may fall into a bath or other water container. . Please do not put other parts into this product. . Please stopping using the product immediately if the product is damaged, smell or smoked caused by improper use. . It may cause product damage and data loss if the product has been clashed or dropped. . Unplug the power cord when encounter a thunderstorm or do not use the product for a long time. Press to adjust clock and alarm time Snooze / LED dimmable Alarm volume Alarm time setting Press to adjust clock and alarm time Turning off alarm - 5 - Top Controls 6 7 1189 10 5V OUT 5V IN TIME12H/24H Controls on the back 1314 1516 17 12 6 8 10 7 9 11 Battery compartment Alarm mode switch (Buzzer/Vibration/Buzzer&Vibration Time setting 12H/24H mode switch USB charging output External power input-DC 5V 1213 1415 1617 9: Display Brightness Adjustment Press SNOOZE button to adjust brightness of the LED display. There are 4 brightness levels. 10: USB Charging The USB charging port supports charging mobiles and supplies 1A charging current. Battery Operated Mode When the device is powered by batteries only, the display will be off in 10 seconds and the alarm will only sound for 3 minutes. USB charging function does not work. The battery life can last for one year normally. We recommend the use of a long-life battery to ensure maximum performance. Power Adapter Please make sure the power adapter is 5V 1.5A or above (Recom- mend 5V 2A). Restore Factory Settings To restore factory settings, press TIME and button for 5 seconds at the same time, after hearing DiDi sound, then all settings are cleared. - 8 - ◎V2 main unit◎Micro USB power cord ◎User manual ◎Warranty card - 4 - ◎Shaker 1 2 3 4 5 Features and Functions 1. Alarm: Easy operating, High/Medium/Low alarm volume, Snooze 2. Clock: Big LED screen to display,12/24 hour mode 3. 4 level dimmable 4. 5V 1A USB charging port 5. Standby mode 6. Dual Alarm Mode: Shaker/Ringtone 7. One touch to turn off the alarm Included in this Package (Please check the accessories included in this package after purchasing) Diagram of the LED Display & Controls Display AM/PM Snooze Alarm Vibrating alarm Time display 123 4 5 1 pc 1 pc 1 pc 1 pc 1 pc Operation Instruction 1:Turn on the Device & the Shaker Connect the micro USB power cord with a 5V power adapter(Not included) and push the micro USB terminal into the power input port on the back of the device or install 3 AAA batteries(not included). On battery mode, USB charging function can not work and the LED display will turn to standby mode in 10 seconds. Install 3 AAA batteries (not included) into the shaker to turn on the shaker. The shaker is on when it vibrates a second. It will connect with the device automatically as the shaker is paired with the device before it leaves the factory. If fail to connect with the device, please refer to the label on the bottom of the device. 2:Time Setting Press TIME button on the back of the device, the time figure begins to flash. Press+/-to select time by minute; Press and hold +/- to select time quickly(Recommended). Press TIME button to confirm time setting(If no operation on any keys in 10seconds, it will confirm the setting and exit automatically ). 3:12H/24H Mode Use the 12H/24H switch behind the unit to select 12 hour or 24 hour display. On 24H mode, AM or PM will display on the screen. 4:Alarm Setting Press button to set alarm. 12:00 and the alarm icon begin to flash on the screen. Press +/- button to select time by minute. Or press and hold +/- button to select time quickly(Recommend). Then press button to confirm the setting. The alarm icon will stop flashing automatically in 10 seconds if no operation occurs. If the alarm is not cancelled, the alarm works everyday…

Text truncated - open the document above for the full version.

Attestation Statements

Page 1 of 1 Declarationonmodeldifference We,AllBestTechnologyLimitedtheundersignedherebyconfirmthat thesemodelsareidentical,andallmodelshavethesameRFmoduleand Antenna,exceptforcolorofenclosureandmodelNo.fortradingpurpose. ProductnameTradenameFCCIDINPUTModelNo. AlarmClockwith BedShaker N/A2AIEGV2 Battery:DC4.5V(AAA*3) MicroUSB:DC5V/1.5A V2,T2,HV2, D21,V2pro, HV2pro,HD3, V2-BT Confirmedby: Client’ssignature: Client’sname/title:WeiwenLiang/Manager Date2020-03-16

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization AllBestTechnologyLimited Company:AllBestTechnologyLimited Address:Yincheng1stRd.,YinchengIndustrialZone,Xiabian Village,Chang’anTown,DongguanCity,Guangdong Province,China ProductName:AlarmClockwithBedShaker ModelNumber:V2 , T2 , HV2 , D21 , V2pro , HV2pro , HD3 , V2-BT FCCIdentifier:2AIEGV2 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:WeiwenLiangDate:2020-03-16 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 AllBestTechnologyLimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2020-3-16 Subject:RequestforConfidentiality FCCID:2AIEGV2 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:WeiwenLiang Title:Manager

External Photos

FCC ID: 2AIEGV2

Test Report

ReportNo.:PTC19111405101E-FC01 Page 1 of 25 FCCTESTREPORT FCCID:2AIEGV2 Product:AlarmClockwithBedShaker ModelName: V2 , T2 , HV2 , D21 , V2pro , HV2pro , HD3 , V2-BT Brand: N/A ReportNo.:PTC19111405101E-FC01 Preparedfor AllBestTechnologyLimited Yincheng1stRd.,YinchengIndustrialZone,XiabianVillage,Chang’anTown,Dongguan City,GuangdongProvince,China Preparedby PreciseTesting&Certification(Guangdong)Co.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China. ReportNo.:PTC19111405101E-FC01 Page 2 of 25 TESTRESULTCERTIFICATION Applicant’sname:AllBestTechnologyLimited Address: Yincheng1stRd.,YinchengIndustrialZone,XiabianVillage,Chang’an Town,DongguanCity,GuangdongProvince,China Manufacture'sname:AllBestTechnologyLimited Address:Yincheng1stRd.,YinchengIndustrialZone,XiabianVillage,Chang’an Town,DongguanCity,GuangdongProvince,China Product:AlarmClockwithBedShaker Model Additionalmodel : V2 T2 , HV2 , D21 , V2pro , HV2pro , HD3 , V2-BT Standards :FCCCFR47Part15Section15.231 Testprocedure :ANSIC63.10:2013 TestDate: March02,2020toMarch05,2020 DateofIssue: March05,2020 TestResult :Pass ThisdevicedescribedabovehasbeentestedbyPTS,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicable onlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTS,this documentmaybealteredorrevisedbyPTS,personalonly,andshallbenotedintherevisionof thedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC19111405101E-FC01 Page 3 of 25 Contents Page 2TESTSUMMARY................................................................................................................................................4 3GENERALINFORMATION...............................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T..........................................................................................................5 3.2TESTMODE...............................................................................................................................................5 3.3TESTSITE.................................................................................................................................................5 4EQUIPMENTDURINGTEST............................................................................................................................6 4.1EQUIPMENTSLIST.....................................................................................................................................6 4.2MEASUREMENTUNCERTAINTY.................................................................................................................6 5CONDUCTEDEMISSION.................................................................................................................................7 6PERIODICOPERATION...................................................................................................................................8 7RADIATEDSPURIOUSEMISSIONS............................................................................................................11 7.1EUTOPERATION....................................................................................................................................11 7.2TESTSETUP............................................................................................................................................12 7.3SPECTRUMANALYZERSETUP...............................................................................................................13 7.4TESTPROCEDURE..................................................................................................................................14 7.5SUMMARYOFTESTRESULTS................................................................................................................15 820DBBANDWIDTHMEASUREMENT.........................................................................................................17 8.1TESTPROCEDURE..................................................................................................................................17 8.2TESTRESULT..........................................................................................................................................17 9ANTENNAREQUIREMENT...........................................................................................................................18 10TESTSETUP...................................................................................................................................................19 11EUTPHOTOS.................................................................................................................................................20 ReportNo.:PTC19111405101E-FC01 Page 4 of 25 2TestSummary TestItemsTestRequirementResult ConductedEmissions15.207N/A RadiatedEmission 15.231(a) 15.209 15.205(a) PASS PeriodicOperation15.35(c)PASS OutsideofBandEmission 15.231(a) 15.205 15.209 PASS 20dBBandwidth 15:215(c) PASS AntennaRequirement15.203PASS Remark: N/A:NotApplicable ReportNo.:PTC19111405101E-FC01 Page 5 of 25 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : AlarmClockwithBedShaker ModelName : V2 Additionalmodel : T2 , HV2 , D21 , V2pro , HV2pro , HD3 , V2-BT OperationFrequency: :433.92MHz Antennainstallation: :IntegratedAntenna AntennaGain: :0dBi TypeofModulation :OOK Thelowestoscillator :433.92MHz Powersupply :DC4.5V(AAA*3) 3.2TestMode Alltestmode(s)andcondition(s)mentionedwereconsideredandevaluatedrespectivelyby performingfulltests,theworstdatawererecordedandreported. ModulationTestmodeLowchannelMiddlechannelHighchannel OOK continuously Transmitting 433.92MHz\\ 3.3TestSite PreciseTesting&Certification(Guangdong)Co.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China. FCCRegistrationNumber:790290 ReportNo.:PTC19111405101E-FC0…

Text truncated - open the document above for the full version.

Test Setup Photos

From 30MHz-1000MHz Radiated Spurious Emissions Above 1GHz FCC ID: 2AIEGV2

Contact Information

Applicant

weiwen Liang(Manager)
[email protected]+86-15814211163Fax: +86-769-86060816

Technical Contact

All Best Technology LimitedWeiwen Liang
[email protected]86-15814211163

Dongguan · China

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term