FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guilin Zhishen Information Technology Co.,Ltd./
  3. 2AIHFZYCR113

2AIHFZYCR113CRANE 2S (Mechanical three-axis stabilizer for Camera with Bluetooth)

Guilin Zhishen Information Technology Co.,Ltd.
CRANE 2S (Mechanical three-axis stabilizer for Camera with Bluetooth) - FCC ID 2AIHFZYCR113 - Guilin Zhishen Information Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 30, 2020
Application Purpose
Original Equipment
Date of Application
Jul 29, 2020
Equipment Note
CRANE 2S (Mechanical three-axis stabilizer for Camera with Bluetooth)
Frequency Range
2402.00000000 - 2480.00000000
Company
Guilin Zhishen Information Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

GuilinZhishenInformationTechnologyCo.,Ltd. Date:2020/07/17 To:FederalCommunicationsCommission, Authorization&EvaluationDivision, 7435OaklandMillsRoad, Columbia,MD21046 ToWhomItMayConcern: TheGuilinZhishenInformationTechnologyCo.,Ltd.theundersigned,hereby authorizesMrs.WendyZhanfromShenzhenMorlabCommunications TechnologyCo.,Ltd.,toactonthebehalfoftheGuilinZhishenInformation TechnologyCo.,Ltd.solelyinmattersrelatingtotheapplicationforanFCC equipmentauthorizationforFCCID:2AIHFZYCR113includingthesigningof documentsinconnectionwiththisApplication.Necessaryactscarriedout ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.onourbehalfofthe GuilinZhishenInformationTechnologyCo.,Ltd.inconnectionwiththeApplication shallhavethesameeffectasactsoftheGuilinZhishenInformationTechnology Co.,Ltd.alsoherebycertifythatnopartytothisapplicationissubjecttoadenialof benefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuse Actof1988,21U.S.C.862. Thankyouforyourattentiontothismatter. YoursSincerely, Signatory: Contactname:YilunLiao Title:CEO Tel:0773-3560519 Email:[email protected] Companyname:GuilinZhishenInformationTechnologyCo.,Ltd.

External Photos

FCCID:2AIHFZYCR113 ExternalPhotos 1.EUTfrontview 2.EUTrearview 3.EUTleftsideview 4.EUTrightsideview 5.EUTtopview 6.EUTbottomview 7.Accessories

ID Label/Location Info

1.Label 2.Labellocation Material:Pimaterial Lablesize:49.1*22.8mm SizeofMiclogo:3.0*3.0mm Color:graytextonaBlackbackground Productlabel:Sticker

Internal Photos

FCC ID:2AIHFZYCR113 Internal Photos 1. EUT uncover view 2. Antenna view Bluetooth Antenna

Test Report

NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 8 REPORT No.:SZ20070033S01 RF EXPOSURE EXEMPT REPORT APPLICANT : Guilin Zhishen Information Technology Co.,Ltd. PRODUCT NAME : CRANE 2S MODEL NAME :CR113 BRAND NAME :ZHIYUN FCC ID : 2AIHFZYCR113 STANDARD(S) : 47CFR 2.1093 KDB 447498 RECEIPT DATE : 2020-07-02 TEST DATE :2020-07-04 to 2020-07-06 ISSUE DATE :2020-07-29 Edited by: Peng Mi (Rapporteur) Approved by: Peng Huarui (Supervisor) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 8 REPORT No.:SZ20070033S01 DIRECTORY 1. Technical Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.1 Applicant and Manufacturer Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.2 Equipment Under Test (EUT) Description βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 3 1.3 Applied Reference Documents βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 4 2. Device Category and RF Exposure Limit βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 5 3. RF Output Power βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 6 4. RF Exposure Evaluation βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 7 Annex A Testing Laboratory Information βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™βˆ™ 8 Change History Version Date Reason for Change 1.0 2020-07-29 First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 8 REPORT No.:SZ20070033S01 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Guilin Zhishen Information Technology Co.,Ltd. Applicant Address: 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China Manufacturer: Guilin Zhishen Information Technology Co.,Ltd. Manufacturer Address: 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China 1.2 Equipment Under Test (EUT) Description Product Name: CRANE 2S Serial No.: (N/A, marked #1 by test site) Hardware Version: 1.0 Software Version: 1.74 Equipment Type: Bluetooth LE Bluetooth Version: 5.0 Operating Frequency Range: 2402MHz - 2480MHz Modulation Type: GFSK(1Mbps) Antenna Type: PCB Antenna Antenna Gain: 2.99dBi MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 8 REPORT No.:SZ20070033S01 1.3 Applied Reference Documents Leading reference documents for testing: No. Identity Document Title Method determination /Remark 1 47 CFRΒ§2.1093 Radio Frequency Radiation Exposure Evaluation: portable devices No deviation 2 KDB 447498 D01v06 General RF Exposure Guidance No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 8 REPORT No.:SZ20070033S01 2. Device Category and RF Exposure Limit Per user manual, this device is a CRANE 2S. Based on 47CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure. Portable Devices: 47CFR 2.1093(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. General Population/Uncontrolled Exposure: 47CFR 2.1093(d) (2) Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels placed on consumer devices such as cellular telephones will not be sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled exposure in paragraph (d)(1) of this se…

Text truncated - open the document above for the full version.

Test Report

NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 39 REPORT No.:SZ20070033W01 TEST REPORT APPLICANT : Guilin Zhishen Information Technology Co.,Ltd. PRODUCT NAME : CRANE 2S MODEL NAME :CR113 BRAND NAME :ZHIYUN FCC ID : 2AIHFZYCR113 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2020-07-02 TEST DATE :2020-07-04 to 2020-07-06 ISSUE DATE :2020-07-29 Edited by: Peng Mi (Rapporteur) Approved by: Peng Huarui (Supervisor) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 39 REPORT No.:SZ20070033W01 DIRECTORY 1. Technical Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.1. Applicant and Manufacturer Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.2. Equipment Under Test (EUT) Description ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 3 1.3. The Channel Number and Frequency ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4 1.4. Test Standards and Results ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 1.5. Environmental Conditions ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6 2. 47 CFR Part 15C Requirements ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 2.1. Antenna Requirement ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 2.2. Duty Cycle of Test Signal ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 2.3. Maximum Peak Conducted Output Power ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9 2.4. Maximum Average Conducted Output Power ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 12 2.5. 6 dB Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 13 2.6. Conducted Spurious Emissions and Band Edge ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 16 2.7. Power Spectral Density (PSD) ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 20 2.8. Conducted Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 23 2.9. Restricted Frequency Bands ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 25 2.10. Radiated Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 29 Annex A Test Uncertainty ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 36 Annex B Testing Laboratory Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 37 Change History Version Date Reason for Change 1.0 2020-07-29 First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 39 REPORT No.:SZ20070033W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Guilin Zhishen Information Technology Co.,Ltd. Applicant Address: 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China Manufacturer: Guilin Zhishen Information Technology Co.,Ltd. Manufacturer Address: 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China 1.2. Equipment Under Test (EUT) Description Product Name: CRANE 2S Serial No.: (N/A, marked #1 by test site) Hardware Version: 1.0 Software Version: 1.74 Equipment Type: Bluetooth LE Bluetooth Version: 5.0 Modulation Type: GFSK Operating Frequency Range: 2402MHz - 2480MHz Antenna Type: PCB Antenna Antenna Gain: 2.99dBi Accessory Information: Battery Brand Name: ZHIYUN Model No.: 18650-2600mAh Serial No.: (N/A, marked #1 by test site) Capacity: 2600.00mAh Rated Voltage: 3.60V Charge Limit: 4.20V MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 39 REPORT No.:SZ20070033W01 Accessory Information: Battery Brand Name: ZHIYUN Model No.: INR 18650-26EC Serial No.: (N/A, marked #1 by test site) Capacity: 2600.00mAh Rated Voltage: 3.70V Charge Limit: 4.20V Note 1: We use the dedicated software to control the EUT continuous transmission. Note 2: For a more detailed description, please refer to Specification or User’s Manual supplied by the applicant and/or manufacturer. 1.3. The Channel Number and Frequency Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 2402 10 2422 20 2442 30 2462 1 2404 11 2424 21 2444 31 2464 2 2406 12 2426 22 2446 32 2466 3 2408 13 2428 23 2448 33 2468 4 2410 14 2430 24 2450 34 2470 5 2412 15 2432 25 2452 35 2472 6 2414 16 2434 26 2454 36 2474 7 2416 17 2436 27 2456 37 2476 8 2418 18 2438 28 2458 38 2478 9 2420 19 2440 29 2460 39 2480 Note: The lowest channel 0, middle 19 and highest 39 were selected for test in the report. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:2AIHFZYCR113 Test Setup Photos 1. Radiated emission (9KHz-30MHz) 2. Radiated emission (30MHz-1GHz) 3. Radiated emission (above 1GHz) 4. RF measurement setup (Bluetooth LE)

Contact Information

Applicant

Yilun Liao(CEO)
[email protected]0773-3560519Fax: 0773-3560519

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is average conducted.

Other Applications from Guilin Zhishen Information Technology Co.,Ltd.

2AIHFZYPLG109

ZHIYUN CINEPEER CG300 COB Light

Aug 26, 2024

Equipment Class

DTS - Digital Transmission System
ZHIYUN CINEPEER CG200 COB Light - FCC ID 2AIHFZYPLG108 - Guilin Zhishen Information Technology Co.,Ltd.
2AIHFZYPLG108

ZHIYUN CINEPEER CG200 COB Light

Aug 26, 2024

Equipment Class

DTS - Digital Transmission System
2AIHFZYEX1F06

AI Tracker for SMOOTH Smartphone Stabilizer

Jul 08, 2024

Equipment Class

DTS - Digital Transmission System
2AIHFZYPL113

ZHIYUN CINEPEER C100 Multi Color Light

Jun 25, 2024

Equipment Class

DTS - Digital Transmission System
2AIHFZYSM121

ZHIYUN CINEPEER CQ5

Jun 18, 2024

Equipment Class

DTS - Digital Transmission System