Remote control robot
Frequency Range
2415.00000000 - 2465.00000000
Company
Runlong Technology (Shantou) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statment: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter. Radiation Exposure Statement The device has been evaluated to meet general RF exposure requirement in portable exposure condition without restriction.

Attestation Statements

Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Attestation Statements Not Covered Entity Applicant & Not Covered Equipment To: Federal Communications Commission Date: Dec. 12, 25 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) & (ii) FCC ID: 2AIOGRL151 Runlong Technology (Shantou) Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List, established pursuant to § 1.50002 of reference chapter, as an entity producing “covered” communication equipment. The equipment for which authorization is sought is not “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List that prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Leo Zhu Title: Manager Address: Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Tel.: 0754-85884383 Email: [email protected]

Attestation Statements

Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China 1 | P a g e Attestation Statements To: Federal Communications Commission Date: Dec. 12, 25 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: 2AIOGRL151 Product Name: Remote control robot This letter serves as an attestation that the equipment identified above ☐ is / ☒ is not (select one) "covered" software as defined under the Federal Communications Commission (FCC) Covered List requirements, as outlined in FCC 22-84 and KDB 986446. Specifically, the undersigned certifies that the equipment for which authorization is sought: 1. Does not contain cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors, assignees, parents, subsidiaries, affiliates, or any entity that has rebranded or relabeled software produced by the aforementioned entities. 2. Does not have the capability to store, run, or deliver any software identified on the FCC Covered List, including but not limited to cybersecurity and anti-virus software. To support this attestation, the appendix evaluation documentation has been prepared and is included in the certification filing. This attestation is based on a thorough evaluation of the device's design, functionality, and software environment. The undersigned affirms that the information provided is accurate and complete to the best of their knowledge. Sincerely yours, Applicant Signature Printed Name: Leo Zhu Title: Manager Address: Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Tel.: 0754-85884383 Email: [email protected] Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China 2 | P a g e Evaluation regarding to the Covered List Software: Compliance Methodology Evaluation Process Results Device is Inherent compliance ☒ The Chipset(s) used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ The Memory used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ There is storage capacity limitation for store or install the Cybersecurity or anti-virus software. Compliance ☒ Operating system used is limited to run, install or deliver the Cybersecurity or anti-virus software. Compliance Device is not Inherent compliance ☐ Evaluation Based on Software Bill of Materials (SBoM) See attached “SBoM“ Note:The SBoM content is limited to the scope of covered list software (e.g. antivirus and cybersecurity software). ☐ Evaluation Based on Scan for Software on the device ☐ Evaluation Based on Filesystem scan ☐ Evaluation Based on Running software check

Cover Letter(s)

Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Date: 2025/12/12 Dear Sir/Madam, We, Runlong Technology (Shantou) Co., Ltd., Hereby declares the following statement, The model and exterior color differences, and the internal circuitry is completely identical for these model: Product name: Remote control robot FCC ID: 2AIOGRL151 Model no.: R-152S, R-151, R-152, R-153, R-154, R-155, R-156, R-157, R-158, R-159, R-151S, R-153S, R-154S, R-155S, R-156S, R-157S, R-158S, R-159S, R-161, R-162, R-163, R-164, R-165, R-166, R-167, R-168, R-169, R-161S, R-162S, R-163S, R-164S, R-165S, R-166S, R-167S, R-168S, R-169S, R-171, R-172, R-173, R-174, R-175, R-176, R-177, R-178, R-179, R-171S, R-172S, R-173S, R-174S, R-175S, R-176S, R-177S, R-178S, R-179S, R-181, R-182, R-183, R-184, R-185, R-186, R-187, R-188, R-189, R-181S, R-182S, R-183S, R-184S, R-185S, R-186S, R-187S, R-188S, R-189S, AG-R01, AG-R02, AG-R03, AG-R04, AG-R05, AG-R06, AG-R07, AG-R08, AG-R09 Sincerely, Name/Title: Leo Zhu / Manager Company: Runlong Technology (Shantou) Co., Ltd. Address: Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Phone: 0754-85884383 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China December 30, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request for: FCC ID: 2AIOGRL151 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of the exhibits accompanying this certification application as outlined below : ⎯ Block Diagram ⎯ Schematics ⎯ Operational Description The above exhibits contain trade secrets and/or proprietary information that are not publicly available and materials that the Applicant has spent considerable efforts in developing. Public disclosure of these may be harmful to the Applicant and give an unfair advantage to competitors on the market. Sincerely, Title: Manager Address: Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Tel.: 0754-85884383 Email: [email protected]

Cover Letter(s)

Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China December 12, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: 2AIOGRL151 I, the undersigned, hereby authorize Shenzhen Tongzhou Testing Co.,Ltd. to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by Shenzhen Tongzhou Testing Co.,Ltd. shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with Runlong Technology (Shantou) Co., Ltd.. We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, Leo Zhu Manager Tel: 0754-85884383 Fax: N/A Email: [email protected]

External Photos

Report No.: TZ0035250847PH02 Page 1 of 4 External Photographs of EUT External Photo 1 External Photo 2 Report No.: TZ0035250847PH02 Page 2 of 4 External Photo 3 External Photo 4 Report No.: TZ0035250847PH02 Page 3 of 4 External Photo 5 External Photo 6 Report No.: TZ0035250847PH02 Page 4 of 4 External Photo 7 External Photo 8

ID Label/Location Info

Label Location FCC ID: 2AIOGRL151

Internal Photos

Report No.: TZ0035250847PH03 Page 1 of 3 Internal Photographs of EUT Internal Photo 1 Internal Photo 2 Report No.: TZ0035250847PH03 Page 2 of 3 Internal Photo 3 Internal Photo 4 SRD antenna Report No.: TZ0035250847PH03 Page 3 of 3 Internal Photo 5

RF Exposure Info

FCC ID:2AIOGRL151 Page 1 of 2 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd RADIO FREQUENCY EXPOSURE Limit According to section B.4 of 447498 D04 Interim General RF Exposure Guidance v01 SAR-based thresholds are derived based on frequency, power, and separation distance of the RF source. The formula defines the thresholds in general for either available maximum time-averaged power or maximum time-averaged ERP, whichever is greater. If the ERP of a device is not easily determined, such as for a portable device with a small form factor, the applicant may use the available maximum time-averaged power exclusively if the device antenna or radiating structure does not exceed an electrical length of λ/4. As for devices with antennas of length greater than λ/4 where the gain is not well defined, but always less than that of a half-wave dipole (length λ/2), the available maximum time-averaged power generated by the device may be used in place of the maximum time-averaged ERP, where that value is not known. The separation distance is the smallest distance from any part of the antenna or radiating structure for all persons, during operation at the applicable ERP. In the case of mobile or portable devices, the separation distance is from the outer housing of the device where it is closest to the antenna. The SAR-based exemption formula of § 1.1307(b)(3)(i)(B), repeated here as Formula (B.2), applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power or effective radiated power (ERP), whichever is greater, of less than or equal to the threshold Pth (mW). This method shall only be used at separation distances from 0.5 cm to 40 cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by Formula (B.2). Where and f is in GHz, d is the separation distance (cm), and ERP 20cm is per Formula (B.1). FCC ID:2AIOGRL151 Page 2 of 2 This report shall not be reproduced except in full, without the written approval of Shenzhen Tongzhou Testing Co.,Ltd Results RF Exposure at Separation distance (cm): 0.5 Mode Antenna Frequency [MHz] Conducted Power [dBm] Manufacturing tolerance Antenna Gain [dBi] Max of ERP and Conducted Power including Tune Up SAR- based exemption threshold Pth [mW] Target Power [dBm] Tolerance ±[dB] [dBm] [mW] SRD Ant1 2415 -3.49 -4 1 0 -3 0.50 2.78 SRD Ant1 2440 -2.13 -2.5 1 0 -1.5 0.71 2.75 SRD Ant1 2465 -2.62 -3 1 0 -2 0.63 2.73 Max of ERP and Conducted Power including Tune Up (dBm) = Max Conducted Tune Up Power(dBm) and Max Conducted Tune Up Power(dBm) + Antenna Gain(dBi)-2.15), whichever is greater. The Maximum Erp is used for Routine Evaluation Exemption according to B.4 of 447498 D04 Interim General RF Exposure Guidance v01. So, the SAR evaluation is not required.

Test Report

深圳市利信辉电子有限公司 深圳市宝安区新安街道兴东社区71区宗泰绿凯智荟园 天线规格承认书 AntennaSpecificationforApproval 客户名称 CustomerName:正杰电子 产品名称: ProductName:PCB2.4G天线 产品料号: PartNO.:C10-35-2.5 制表: WriteBy:李瑞 日期: IssuedDate:2024.06.28 客户: 工程R&DDept采购BusinessDept承认ApprovedBy 李工张燕王伟 利信辉 研发R&DDept 工程EngineerDept 审核Approval 赵工韦工李志杰 ProductSpecification A.Electrical Characteristics Frequency 2400MHz ~2500MHz VSWR <3.0 Efficiency >30% Impedance 50 Ohm Polarization Line Gain 0DBi B.Material & Mechanical Characteristics Material of Radiator Cu Connector Type : NO Dimension C.Environmental Operation Temperature - 30 °C ~ + 80 °C Storage Temperature - 30 °C ~ + 85 °C TestEquipment&Conditions 1.NetworkAnalyzers: Agilent8753D5071B 2.CommunicationsTestSet: AgilentE5515C 3.3DChamberTestSystem Effiency&Gain Effiency&Gain 2.4 00-0.00 2.440-0.11 2.48 0-0.13 RadiationPattern: - - - -

Test Report

Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 1 of 23 Appendix Test Data for SRD (Conducted Measurement) Product Name: Remote control robot Trade Mark: / Test Model: R-152S FCC ID: 2AIOGRL151 Environmental Conditions Temperature: 23.5°C Relative Humidity: 58% ATM Pressure: 100.0 kPa Test Engineer: Allen Lai Supervised by: Max Zhang NOTE N/A Appendix A: DTS Bandwidth Test Result Test Mode Antenna Frequency [MHz] DTS BW [MHz] FL [MHz] FH [MHz] Limit [MHz] Verdict SRD Ant1 2415 0.632 2414.744 2415.376 0.5 PASS SRD Ant1 2440 0.660 2439.748 2440.408 0.5 PASS SRD Ant1 2465 0.612 2464.740 2465.352 0.5 PASS Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 2 of 23 Test Graphs SRD-Ant1-2415-PASS SRD-Ant1-2440-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 3 of 23 SRD-Ant1-2465-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 4 of 23 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Frequency [MHz] OCB [MHz] FL [MHz] FH [MHz] Limit [MHz] Verdict SRD Ant1 2415 1.0445 2414.5633 2415.6078 --- --- SRD Ant1 2440 1.0442 2439.5670 2440.6112 --- --- SRD Ant1 2465 1.0558 2464.5614 2465.6172 --- --- Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 5 of 23 Test Graphs SRD-Ant1-2415 SRD-Ant1-2440 Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 6 of 23 SRD-Ant1-2465 Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 7 of 23 Appendix C: Maximum peak conducted output power Test Result Peak Test Mode Antenna Frequency [MHz] Conducted Peak Power [dBm] Conducted Limit [dBm] Verdict SRD Ant1 2415 -3.49 ≤30 PASS SRD Ant1 2440 -2.13 ≤30 PASS SRD Ant1 2465 -2.62 ≤30 PASS Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 8 of 23 Test Graphs Peak SRD-Ant1-2415-PASS SRD-Ant1-2440-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 9 of 23 SRD-Ant1-2465-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 10 of 23 Appendix D: Maximum peak power spectral density Test Result Test Mode Antenna Frequency [MHz] Result [dBm/3kHz] Limit [dBm/3kHz] Verdict SRD Ant1 2415 -19.06 ≤8.00 PASS SRD Ant1 2440 -18.03 ≤8.00 PASS SRD Ant1 2465 -18.65 ≤8.00 PASS Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 11 of 23 Test Graphs SRD-Ant1-2415-PASS SRD-Ant1-2440-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 12 of 23 SRD-Ant1-2465-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 13 of 23 Appendix E: Band edge measurements Test Result Test Mode Antenna Ch. Name Frequency [MHz] Ref. Level [dBm] Result [dBm] Limit [dBm] Verdict SRD Ant1 Low 2415 -4.57 -50.06 ≤-24.57 PASS SRD Ant1 High 2465 -4.16 -48.1 ≤-24.16 PASS Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 14 of 23 Test Graphs SRD-Ant1-2415-PASS SRD-Ant1-2465-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 15 of 23 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Frequency [MHz] Freq. Range [MHz] Ref. Level [dBm] Result [dBm] Limit [dBm] Verdict SRD Ant1 2415 0~Reference -4.50 -4.50 --- PASS SRD Ant1 2415 30~1000 -4.50 -62.68 ≤-24.5 PASS SRD Ant1 2415 1000~26500 -4.50 -44.89 ≤-24.5 PASS SRD Ant1 2440 0~Reference -3.10 -3.10 --- PASS SRD Ant1 2440 30~1000 -3.10 -62.48 ≤-23.1 PASS SRD Ant1 2440 1000~26500 -3.10 -44.95 ≤-23.1 PASS SRD Ant1 2465 0~Reference -4.17 -4.17 --- PASS SRD Ant1 2465 30~1000 -4.17 -56.33 ≤-24.17 PASS SRD Ant1 2465 1000~26500 -4.17 -45.76 ≤-24.17 PASS Note: offset(dB) in Reference test plots = cable loss(dB) + attenuator factor(dB); For spurious emissions plots from 30MHz to 26.5GHz, the cable loss and attenuator factors have been set in the 'Input Correction' of the Spectrum Analyzer during the test. Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 16 of 23 Test Graphs SRD-Ant1-2415-0~Reference-PASS SRD-Ant1-2415-30~1000-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 17 of 23 SRD-Ant1-2415-1000~26500-PASS SRD-Ant1-2440-0~Reference-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 18 of 23 SRD-Ant1-2440-30~1000-PASS SRD-Ant1-2440-1000~26500-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 19 of 23 SRD-Ant1-2465-0~Reference-PASS SRD-Ant1-2465-30~1000-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 20 of 23 SRD-Ant1-2465-1000~26500-PASS Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 21 of 23 Appendix G: Duty Cycle Test Result Test Mode Antenna Frequency [MHz] ON Time [ms] Period [ms] Duty Cycle [%] Duty Cycle Factor [dB] SRD Ant1 2415 0.18 0.57 31.03 4.85 SRD Ant1 2440 0.18 0.57 31.03 4.85 SRD Ant1 2465 0.19 0.58 32.76 4.85 Note: offset(dB) = cable loss(dB) + attenuator factor(dB) Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 22 of 23 Test Graphs NTNV-SRD-Ant1-2415 NTNV-SRD-Ant1-2440 Appendix Test Data of the Report No.: TZ0035250847FRF12 Page 23 of 23 NTNV-SRD-Ant1-2465

Test Report

Report No.: TZ0035250847FRF12 Page 1 of 31 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Tongzhou Testing Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Tongzhou Testing Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. The test report apply only to the specific sample(s) tested under stated test conditions. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. TEST REPORT Report Number : TZ0035250847FRF12 Product Name : Remote control robot Model/Type reference : R-152S, R-151, R-152, R-153, R-154, R-155, R-156, R-157, R-158, R-159, R-151S, R-153S, R-154S, R-155S, R-156S, R-157S, R-158S, R-159S, R-161, R-162, R-163, R-164, R-165, R-166, R-167, R-168, R-169, R-161S, R-162S, R-163S, R-164S, R-165S, R-166S, R-167S, R-168S, R-169S, R-171, R-172, R-173, R-174, R-175, R-176, R-177, R-178, R-179, R-171S, R-172S, R-173S, R-174S, R-175S, R-176S, R-177S, R-178S, R-179S, R-181, R-182, R-183, R-184, R-185, R-186, R-187, R-188, R-189, R-181S, R-182S, R-183S, R-184S, R-185S, R-186S, R-187S, R-188S, R-189S, AG-R01, AG-R02, AG-R03, AG-R04, AG-R05, AG-R06, AG-R07, AG-R08, AG-R09 FCC ID : 2AIOGRL151 Prepared for : Runlong Technology (Shantou) Co., Ltd. Auxiliary Road of Shanbei Avenue, Fengxin Industrial Zone, Fengxiang Street, Chenghai District, Shantou City, Guangdong Province, China Prepared By : Shenzhen Tongzhou Testing Co.,Ltd. 1st Floor, Building 1, Haomai High-tech Park, Huating Road 387, Dalang Street, Longhua, Shenzhen, China Standards : FCC CFR Title 47 Part 15C, ANSI C63.10-2020 Date of Test : 2025-09-02 ~ 2025-10-13 Date of Issue : 2025-10-14 Prepared by : Lena Wen Reviewed by : Allen Lai Approved by : Max Zhang (Authorized Officer) Report No.: TZ0035250847FRF12 Page 2 of 31 ** Report Revise Record ** Report Version Revise Time Issued Date Valid Version Notes V1.0 / 2025-10-14 Valid Initial release Report No.: TZ0035250847FRF12 Page 3 of 31 TABLE OF CONTENTS 1. G E N E R A L I N F O R M A T I O N ....................................................... 4 1.1. Client Information ................................................................................................................... 4 1.2. Description of Device (EUT) ................................................................................................... 4 1.3. Wireless Function Tested in this Report .............................................................................. 5 1.4. EUT configuration ................................................................................................................... 5 1.5. Description of Test Facility .................................................................................................... 5 1.6. Statement of the Measurement Uncertainty ......................................................................... 6 1.7. Measurement Uncertainty ...................................................................................................... 6 1.8. Description of Test Modes ..................................................................................................... 6 1.9. Frequency of Channels .......................................................................................................... 7 2. T E S T M E T H O D O L O G Y ............................................................ 8 2.1. EUT Configuration .................................................................................................................. 8 2.2. EUT Exercise ........................................................................................................................... 8 2.3. Test Sample ............................................................................................................................. 8 3. S Y S T E M T E S T C O N F I G U R A T I O N .............................................. 9 3.1. Justification ............................................................................................................................. 9 3.2. EUT Exercise Software ........................................................................................................... 9 3.3. Special Accessories ............................................................................................................... 9 3.4. Block Diagram/Schematics .................................................................................................... 9 3.5. Equipment Modifications ....................................................................................................... 9 3.6. Test Setup ................................................................................................................................ 9 4. S U M M A R Y O F T E S T R E S U L T S ............................................... 10 5. T E S T R E S U L T .................................................................... 11 5.1. On Time and Duty Cycle ....................................................................................................... 11 5.2. Maximum Peak Conducted Output Power Measurement ................................................. 12 5.3. Power Spectral Density Measurement ................................................................................ 13 5.4. 6 dB Spectrum Bandwidth and Occupied Channel Bandwidth Measurement ............... 14 5.5. Radiated Emissions Measurement ...................................................................................... 15 5.6. Conducted Spurious Emissions and Band Edges Test .................................................... 24 5.8. Band-edge measurements for radiated emissions ........................................................... 26 5.9. Antenna Requirements .......................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: TZ0035250847PH01 Page 1 of 1 Test Setup Photos of the EUT Radiated Emission Below 1GHz Radiated Emission Above 1GHz

Contact Information

Applicant

Leo Zhu
[email protected]Fax: N/A

Technical Contact

Picus Advisors US LLCIvan Wang
[email protected]

5855 SOVEREIGN DRSTE B-1, · HOUSTON, Texas, 77036 · United States

Test Firm

Shenzhen Tongzhou Testing Co., LTDAndy Zhang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.42 GHz - 2.46 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.