(INFINIX MOBILITY LIMITED) (July 10, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AIZN-XEH1LR#) [INFINIX MOBILITY LIMITED] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Jerry Liu/ Manger (INFINIX MOBILITY LIMITED) (July 10, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AIZN-XEH1LR#) [INFINIX MOBILITY LIMITED] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Jerry Liu/ Manger
IZN
INFINIX MOBILITY LIMITED Agent Authorization Letter (July 10, 2026) Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (WORLD STANDARDIZATION CERTIFICATION & TESTING GROUP (SHENZHEN) CO., LTD.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s name / title : Jerry Liu/ Manger Company Name: INFINIX MOBILITY LIMITED Contact information / address: [email protected]/ FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG.
INFINIX MOBILITY LIMITED Long Term Confidentiality Request Letter (July 10, 2026) Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Wireless Over-Ear Headphones Model No: XEH1 FCC ID: 2AIZN-XEH1LR To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above-mentioned documents belong to internal documents, is our proprietary information, that could never get into the possession of our competition. Please contact me if there is any information you may need. Sincerely, Client’s name / title: Jerry Liu / Manger Company Name: INFINIX MOBILITY LIMITED Contact information / address: [email protected] FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG.
Short Term Confidentiality Request Letter (July 10, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For(Wireless Over-Ear Headphones/XEH1# FCC ID:2AIZN-XEH1LR #) To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, < INFINIX MOBILITY LIMITED >. requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Set up Photos Internal photos External photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which < INFINIX MOBILITY LIMITED > considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, < INFINIX MOBILITY LIMITED.> feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Yiting Luo / Manger Signature:
游戏头戴耳机_菲林文件_260410_V04 蒋尚宏V01 最终效果示意图 激光镭雕 (follow 金属件深灰色) *文档线框仅供参考, 最终输出依供应商版本为主 高亮字 3D机加工竖纹 激光镭雕 (follow 金属件深灰色) 激光镭雕 (打黑) 1 2 4 *侧盖 台阶+竖纹 内腔体- L/R 字符 左右上下中心, 需与内衬中心对齐 *外观定义 距离上分型线 1.60mm <- 左边内侧右边内侧 -> 距离上分型线 5.96 mm
Page 1 of 7 FCC RF Exposure Report For INFINIX MOBILITY LIMITED FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Model : XEH1 Report Number: WSCT-ANAB-R&E260600056A Report Date: 07 July 2026 FCC ID: 2AIZN-XEH1LR Prepared By: World Standardization Certification & Testing Group (Shenzhen) Co., Ltd. Building A-B,Baoli'an Industrial Park,No.58 and 60,Tangtou Avenue, Shiyan Street, Bao'an District, Shenzhen City, Guangdong Province, China Tel: +86-755-26996192 Fax: +86-755-86376605 Report No.: WSCT-ANAB-R&E260600056A SAR Evaluation Report Page 2 of 7 Table of contents 1 General information .......................................................................................................................................... 3 1.1 Notes ........................................................................................................................................................... 3 1.2 EUT Information ......................................................................................................................................... 4 2 Testing laboratory ............................................................................................................................................. 5 3 ACCREDITATIONS ............................................................................................................................................ 5 4 Applicant and Manufacturer ............................................................................................................................ 5 5 Test standard/s: ................................................................................................................................................ 5 6 Test result ........................................................................................................................................................... 6 7 Conclusion .......................................................................................................................................................... 7 Report No.: WSCT-ANAB-R&E260600056A SAR Evaluation Report Page 3 of 7 Modified History REV. Modification Description Issued Date Remark REV.1.0 Initial Test Report Relesse 07 July 2026 Li Huaibi 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in this test report. Shenzhen Timeway Testing Laboratories does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report is not to be reproduced or published in full without the prior written permission. Report No.: WSCT-ANAB-R&E260600056A SAR Evaluation Report Page 4 of 7 1.2 EUT Information Device Information: Product Type: Wireless Over-Ear Headphones Model: XEH1 Trade Name: Infinix Software version: V1.0 Hardware version: V1.1 Device Type: Portable device Exposure Category: uncontrolled environment / general population Production Unit or Identical Prototype: Production Unit Antenna Type : Onboard Antenna Device Operating Configurations: Modulation: GFSK, π/4-DQPSK, 8-DPSK Channel Separation: BT: 1MHz BLE:2MHz Operation Frequency: 2402MHz~2480MHz Antenna Gain: XEH1:-0.68dBi Power Source: Rechargeable Li-ion Polymer Battery: 701250 3.85V 400mAh 1.48Wh Limited Charge Voltage:4.4V Note:The test results of this test report relate exclusively to the test item specified in this test report. World Standardization Certification & Testing Group (Shenzhen) Co.,Ltd does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report is not to be reproduced or published in full without the prior written permission. Report No.: WSCT-ANAB-R&E260600056A SAR Evaluation Report Page 5 of 7 2 Testing laboratory Test Site World Standardization Certification & Testing Group (Shenzhen) Co., Ltd. Laboratory A: Building A-B,Baoli'an Industrial Park,No.58 and 60,Tangtou Avenue, Shiyan Street, Bao'an District, Shenzhen City, Guangdong Province, China TEL: +86-755-26996192 FAX: +86-755-86376605 3 ACCREDITATIONS Our laboratories are accredited and approved by the following approval agencies according to ISO/IEC 17025:2017. USA ANAB - Certificate Number: AT-3951 China CNAS (Registration Number: L3732) Canada ISED(CAB identifier:CN0178) Copies of granted accreditation certificates are available for downloading from our web site, http://www.wsct-cert.com 4 Applicant and Manufacturer Applicant/Client Name: INFINIX MOBILITY LIMITED Applicant Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Manufacturer Name: INFINIX MOBILITY LIMITED Manufacturer Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG 5 Test standards: No. Identity Document Title 1 47 CFR Part 15C Radio frequency devices intentional radiators 2 47 CFR Part 2.1093 Radio frequency radiation exposure evaluation: portable devices 3 KDB447498 D01 General RF Exposure Guidance v06 Report No.: WSCT-ANAB-R&E260600056A SAR Evaluation Report Page 6 of 7 6 Test result According KDB 447498 D01 4.3.1 General SAR test exclusion guidance Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test…
Text truncated - open the document above for the full version.
Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 46 of 78 Dwell 1-DH3 2480MHz One Burst Dwell 1-DH3 2480MHz Accumulated Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 47 of 78 Dwell 1-DH5 2402MHz One Burst Dwell 1-DH5 2402MHz Accumulated Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 48 of 78 Dwell 1-DH5 2441MHz One Burst Dwell 1-DH5 2441MHz Accumulated Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 49 of 78 Dwell 1-DH5 2480MHz One Burst Dwell 1-DH5 2480MHz Accumulated Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 50 of 78 6.8. Pseudorandom Frequency Hopping Sequence Test Requirement: FCC Part15 C Section 15.247 (a)(1) requirement: Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. Alternatively. Frequency hopping systems operating in the 2400-2483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output power no greater than 125 mW. The system shall hop to channel frequencies that are selected at the system hopping rate from a Pseudorandom ordered list of hopping frequencies. Each frequency must be used equally on the average by each transmitter. The system receivers shall have input bandwidths that match the hopping channel bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the transmitted signals. EUT Pseudorandom Frequency Hopping Sequence The pseudorandom sequence may be generated in a nine-stage shift register whose 5th and 9th stage outputs are added in a modulo-two addition stage. And the result is fed back to the input of the first stage. The sequence begins with the first one of 9 consecutive ones; i.e. the shift register is initialized with nine ones. • Number of shift register stages: 9 • Length of pseudo-random sequence: 2 9 -1 = 511 bits • Longest sequence of zeros: 8 (non-inverted signal) An example of Pseudorandom Frequency Hopping Sequence as follow: Each frequency used equally on the average by each transmitter. The system receivers have input bandwidths that match the hopping channel bandwidths of their corresponding transmitters and shift frequencies in synchronization with the transmitted signals. Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 51 of 78 6.9. Conducted Band Edge Measurement 6.9.1. Test Specification Test Requirement: FCC Part15 C Section 15.247 (d) Test Method: ANSI C63.10:2020 Limit: In any 100 kHz bandwidth outside the intentional radiation frequency band, the radio frequency power shall be at least 20 dB below the highest level of the radiated power. In addition, radiated emissions which fall in the restricted bands must also comply with the radiated emission limits. Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. The testing follows the guidelines in Band-edge Compliance of RF Conducted Emissions of ANSI C63.10:2020 Measurement Guidelines. 2. Set to the maximum power setting and enable the EUT transmit continuously. 3. Set RBW = 100 kHz (≥1% span=10MHz), VBW = 300 kHz (≥RBW). Band edge emissions must be at least 20 dB down from the highest emission level within the authorized band as measured with a 100kHz RBW. The attenuation shall be 30 dB instead of 20 dB when RMS conducted output power procedure is used. 4. Enable hopping function of the EUT and then repeat step 2 and 3. 5. Measure and record the results in the test report. Test Result: PASS Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 52 of 78 6.9.2. Test Data GFSK Modulation(the worst case) XEH1 Test Graphs Band Edge 1-DH5 2402MHz No-Hopping Ref Band Edge 1-DH5 2402MHz No-Hopping Emission Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 53 of 78 Band Edge 1-DH5 2480MHz No-Hopping Ref Band Edge 1-DH5 2480MHz No-Hopping Emission Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 54 of 78 Test Graphs Band Edge(Hopping) 1-DH5 2402MHz Hopping Ref Band Edge(Hopping) 1-DH5 2402MHz Hopping Emission Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 55 of 78 Band Edge(Hopping) 1-DH5 2480MHz Hopping Ref Band Edge(Hopping) 1-DH5 2480MHz Hopping Emission Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 56 of 78 6.10. Conducted Spurious Emission Measurement 6.10.1. Test Specification Test Requirement: FCC Part15 C Section 15.247 (d) Test Method: ANSI C63.10:2020 Limit: In any 100 kHz bandwidth outside the intentional radiation frequency band, the radio frequency power shall be at least 20 dB below the highest level of the radiated power. In addition, radiated emissions which fall in the restricted bands must also comply with the radiated emission limits. Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. The testing follows the guidelines in Spurious RF Conducted Emissions of ANSI C63.10:2020 Measurement Guidelines 2. The RF output of EUT was connected to the spectrum analyzer by RF cable and attenuator. The path loss was compensated to the results for each measurement. 3. Set to the maximum power setting and enable the EUT transmit continuously. 4. Set RBW = 100 kHz, VBW = 300kHz, scan up through 10th harmonic. All harmonics / spurs must be at least 20 dB down from the highest emission level within the authorized band as measured with a 100 kHz RBW. 5. Measure and record the results in the test report. 6. The RF fundamental frequency should be excluded against the limit line in the operating frequency band. Test Result: PASS Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None…
Text truncated - open the document above for the full version.
Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.73 -0.84 -0.68 -6.15 -3.70 -2.32 MAX. Gain -0.68 Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ShenZhen DeXinCheng Technology CO. ,LTD Address A3 Building, 2nd Floor East, Changfeng Road, 349, Changzhen Community, Yuangang Street, Guangming, Shenzhen, Guangdong (DeXingCheng Technology)广东 省深圳市光明区玉塘街道长圳社区长凤路349号A3栋2楼 东(德芯成科技) Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -1.73178 -30.0815 -8.48713 2450 -0.845801 -38.5605 -7.88012 2500 -0.685586 -24.0318 -6.79139 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -6.1530 -24.1420 -13.0295 2450 -3.7054 -26.5836 -10.6700 2500 -2.32122 -30.4301 -9.70536 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 2 of 78 TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. Genera Information .................................................................................. 7 4.1. TEST ENVIRONMENT AND MODE .............................................................................................................. 7 4.2. DESCRIPTION OF SUPPORT UNITS .......................................................................................................... 7 5. Facilities and Accreditations .................................................................. 8 5.1. FACILITIES ............................................................................................................................................ 8 5.2. ACCREDITATIONS ............................................................................................................................ 8 5.3. MEASUREMENT UNCERTAINTY ............................................................................................................... 9 5.4. MEASUREMENT INSTRUMENTS ................................................................................................... 10 6. Test Results and Measurement Data ................................................... 11 6.1. ANTENNA REQUIREMENT ...................................................................................................................... 11 6.2. CONDUCTED EMISSION ........................................................................................................................ 12 6.3. CONDUCTED OUTPUT POWER .............................................................................................................. 14 6.4. 20DB OCCUPY BANDWIDTH ................................................................................................................. 21 6.5. CARRIER FREQUENCIES SEPARATION .................................................................................................. 23 6.6. HOPPING CHANNEL NUMBER ............................................................................................................... 35 6.7. DWELL TIME ........................................................................................................................................ 37 6.8. PSEUDORANDOM FREQUENCY HOPPING SEQUENCE ............................................................................. 41 6.9. CONDUCTED BAND EDGE MEASUREMENT ............................................................................................ 51 6.10. CONDUCTED SPURIOUS EMISSION MEASUREMENT................................................................................ 54 6.11. RADIATED SPURIOUS EMISSION MEASUREMENT ................................................................................... 57 Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 4 of 78 2. Test Result Summary Requirement CFR 47 Section Result Antenna Requirement §15.203/§15.247 (c) PASS AC Power Line Conducted Emission §15.207 NA Conducted Peak Output Power §15.247 (b)(1) §2.1046 PASS 20dB Occupied Bandwidth §15.247 (a)(1) §2.1049 PASS Carrier Frequencies Separation §15.247 (a)(1) PASS Hopping Channel Number §15.247 (a)(1) PASS Dwell Time §15.247 (a)(1) PASS Radiated Emission §15.205/§15.209 §2.1053, §2.1057 PASS Band Edge §15.247(d) §2.1051, §2.1057 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 5 of 78 3. EUT Description Product Name: Wireless Over-Ear Headphones Model : XEH1 Trade Mark: Infinix Operation Frequency: 2402MHz~2480MHz Channel Separation: 1MHz Number of Channel: 79 Modulation Type: GFSK, π/4-DQPSK, 8-DPSK Modulation Technology: FHSS Software Version V1.0 Hardware Version V1.1 Antenna Type: Onboard Antenna Antenna Gain: XEH1:-0.68dBi Operating Voltage Rechargeable Li-ion Polymer Battery: 701250 3.85V 400mAh 1.48Wh Limited Charge Voltage:4.4V Remark: N/A. Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 6 of 78 Operation Frequency each of channel for GFSK, π/4-DQPSK, 8DPSK Channel Frequency Channel Frequency Channel Frequency Channel Frequency 0 2402MHz 20 2422MHz 40 2442MHz 60 2462MHz 1 2403MHz 21 2423MHz 41 2443MHz 61 2463MHz ... ... ... ... ... ... ... ... 10 2412MHz 30 2432MHz 50 2452MHz 70 2472MHz 11 2413MHz 31 2433MHz 51 2453MHz 71 2473MHz ... ... ... ... ... ... ... ... 18 2420MHz 38 2440MHz 58 2460MHz 78 2480MHz 19 2421MHz 39 2441MHz 59 2461MHz - Remark: Channel 0, 39 &78 have been tested for GFSK, π/4-DQPSK, 8DPSK modulation mode. Report No.: WSCT-ANAB-R&E260600056A -BT Issued 07 July 2026 Revised: None Page 7 of 78 4. Genera Information 4.1. Test environment and mode Operating Environment: Temperature: 25.0 C Humidity: 56 % RH Atmospheric Pressure: 1010 mbar Test Mode: Engineering mode: Keep the EUT in continuous transmitting by select channel and modulations with Fully-charged battery The sample was placed 0.8m & 1.5m for the measurement below & above 1GHz above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertic…
Text truncated - open the document above for the full version.
5855 SOVEREIGN DRSTE B-1, HOUSTON, TX 77036 · HOUSTON · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 7.00 mW |
Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterInfinix Space Max
Equipment Class
JAB - Part 15 Class B Digital DeviceGT NX Controller
Equipment Class
JAB - Part 15 Class B Digital DeviceGT NX Controller
Equipment Class
JAB - Part 15 Class B Digital DeviceTablet
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter