Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Installation & Quick Start Guide ZKTeco FR1200 I 2 3 4 5 6 Reader Start Getting control order timeout? Only FP verification? FP or card verification? FP and card verification? Send card number and FP template to access control panel Prompt: 1 beep, green LED on Verification result timeout? N Y N N Get FP template, 1 beep, light off, switch to 485 Only card verification? Get card number already?? Y Y Y Send FP template to access control panel Pass the verification? Prompt: 2 beeps, red LED on Reader stop Prompt: 3 beeps, green LED on N N YN N Y Y Y 7 8 Reader Start Getting control order timeout? Only card verification? FP or card verification? Only card verification? Send no data to access control panel, switch to main mission, waiting for FP and follow the verification process of press FP first Prompt: 1 beep, green LED on Verification result timeout? N Y N Get card, 1 beep, light off, switch to 485 FP and card verification? Y Y Send card number to access control Pass the verification? Prompt: 2 beeps, red LED on Reader Stop Prompt: 3 beeps, green LED on N N Y N N Y Y Y N 9 10 11 12 New Firmware for 3/3.5-inch Color Screen NO.26,Pingshan 188 Industry zone, Tangxia Town, Dongguan City Guangdong Province, China 523728 FCCCaution: AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance couldvoidtheuser'sauthoritytooperatetheequipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
Differences Declaration To whom concern, We company ZKTECO CO., LTD. Here by declares: The product model(s) FR1200-ID, FR1300 are the same PCB layout, electronic schematic and Antenna with FR1200, which tested in Shenzhen Huatongwei International Inspection Co., Ltd. They are the same model that has 3 names. Sincerely yours, Signature: Name: Zhonglie Ge Company name: ZKTECO CO., LTD. Company address: No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China 523728 E-Mail: [email protected]
ZKTECOCO.,LTD. LetterofAuthorization Company:ZKTECOCO.,LTD. Address:No.26,Pingshan188Industryzone,TangxiaTown,DongguanCity, GuangdongProvince,China523728 ProductName:BiometricReader ModelNumber:FR1200,FR1200-ID,FR1300 FCCIdentifier:2AJ9T-FRI WeauthorizeMiCOMLabsInc,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningtheabovenamedequipment. AnyindividualwithinMiCOMLabsisauthorizedtoactonourbehalfandtakeactionon theapplication. WedeclarethatMiCOMLabsInc,575BoulderCourt,Pleasanton,California94566, USA,isallowedtoforwardallinformationrelatedtotheapprovalprojecttotheFederal CommunicationCommissionandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyMiCOMLabsonourbehalfshallhavethe sameeffectasactsofourown. Name:Date:2020-10-20 Title:Engineer
External Photos
Internal Photos
Page: 1 of 24 TEST REPORT Report No. ...................................... : CHTEW20100048 Report Verification: Project No.................................: SHT2010013901EW FCC ID ............................................. : 2AJ9T-FRI Applicant’s name ........................... : ZKTECO CO., LTD. Address ............................................. : No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China 523728 Test item description .................... : Biometric Reader Trade Mark ....................................... : - Model/Type reference ....................... : FR1200 Listed Model(s) ................................. : FR1200-ID, FR1300 Standard ......................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.209 Date of receipt of test sample..........: Oct.12, 2020 Date of testing.............................: Oct.12, 2020- Oct.15, 2020 Date of issue...............................: Oct.16, 2020 Result .................. ........................: PASS Compiled by ( Position+Printed name+Signature): File administrator Echo Wei Supervised by (Position+Printed name+Signature): Project Engineer Kiki Kong Approved by (Position+Printed name+Signature): RF Manager Hans Hu Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd. Address ............................................. : 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. The test report merely correspond to the test sample. Report No : CHTEW20100048 Page 2 of 24 Issued: 2020-10-16 Shenzhen Huatongwei International Inspection Co., Ltd. Report Template Version: V02 (2019-10) Contents 1. TEST STANDARDS AND REPORT VERSION 3 1.1. Test Standards 3 1.2. Report version information 3 2. TEST DESCRIPTION 4 3. SUMMARY 5 3.1. Client Information 5 3.2. Product Description 5 3.3. Radio Specification Description 5 3.4. Testing Laboratory Information 5 4. TEST CONFIGURATION 6 4.1. Test frequency list 6 4.2. EUT operation mode 6 4.3. EUT configuration 6 4.4. Environmental conditions 6 4.5. Statement of the measurement uncertainty 6 4.6. Modifications 6 4.7. Equipments Used during the Test 7 5. TEST CONDITIONS AND RESULTS 9 5.1. Antenna requirement 9 5.2. AC Power Conducted Emissions 10 5.3. 20dB Bandwidth 13 5.4. Radiated Emission 14 6. TEST SETUP PHOTOS OF THE EUT 17 7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT 19 Report No : CHTEW20100048 Page 3 of 24 Issued: 2020-10-16 Shenzhen Huatongwei International Inspection Co., Ltd. Report Template Version: V02 (2019-10) 1. TEST STANDARDS AND REPORT VERSION 1.1. Test Standards The tests were performed according to following standards: FCC Rules Part 15.209: Radiated emission limits; general requirements ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices. 1.2. Report version information Revision No. Date of issue Description N/A 2020-10-16 Original Report No : CHTEW20100048 Page 4 of 24 Issued: 2020-10-16 Shenzhen Huatongwei International Inspection Co., Ltd. Report Template Version: V02 (2019-10) 2. TEST DESCRIPTION Report clause Test Item Section in CFR 47 Result 5.1 Antenna requirement 15.203 PASS 5.2 AC Power Line Conducted Emissions 15.207 PASS 5.3 20dB Occupied Bandwidth 2.1049 PASS 5.4 Spurious Emissions 15.209 PASS Remark: The measurement uncertainty is not included in the test result. Report No : CHTEW20100048 Page 5 of 24 Issued: 2020-10-16 Shenzhen Huatongwei International Inspection Co., Ltd. Report Template Version: V02 (2019-10) 3. SUMMARY 3.1. Client Information Applicant: ZKTECO CO., LTD. Address: No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China 523728 Manufacturer: ZKTECO CO., LTD. Address: No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China 523728 3.2. Product Description Name of EUT: Biometric Reader Trade Mark: - Model No.: FR1200 Listed Model(s): FR1200-ID, FR1300 Power supply: DC 12V Hardware version: V1.1 Software version: V1.2 3.3. Radio Specification Description Operation frequency: 125kHz Channel number: 1 Modulation Type: ASK Antenna type: induction coil antenna Antenna gain: 0dBi 3.4. Testing Laboratory Information Laboratory Name Shenzhen Huatongwei International Inspection Co., Ltd. Laboratory Location 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China Qualifications Type Accreditation Number CNAS L1225 A2LA 3902.01 FCC 762235 Canada 5377A Report No : CHTEW20100048 Page 6 of 24 Issued: 2020-10-16 Shenzhen Huatongwei International Inspection Co., Ltd. Report Template Version: V02 (2019-10) 4. TEST CONFIGURATION 4.1. Test frequency list Channel Frequency (KHz) 00 125 4.2. EUT operation mode TEST MODE For RF test items The engineering test program was provided and enabled to make EUT continuous transmit. For AC power line conducted emissions: The EUT was set to connect with large package sizes transmission. 4.3. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ○ - supplied by the manufacturer ● - supplied by the lab Manufacturer : / Model No. : / Manufacturer : / Model No. : / 4.4. Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15~35°C Relative Humidity: 30~60 % Air Pressure: 950~1050mba 4.5. Statement of the measurement uncertaint…
Text truncated - open the document above for the full version.
TEST SETUP PHOTOS OF THE EUT Conducted Emissions (AC Mains) Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
Smart Access Control Terminal
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart Lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart Identification Terminal
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterBase Station
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter