FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fitness Audio Network P/L/
  3. 2AJMEUTX-16

2AJMEUTX-16Wireless Microphone Transmitter

Fitness Audio Network P/L
Wireless Microphone Transmitter - FCC ID 2AJMEUTX-16 - Fitness Audio Network P/L
Click to zoom

Application Details

Equipment Class
DWM - Part 15 Wireless Microphone
Date of Grant
Mar 11, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Microphone Transmitter
Frequency Range
471.10000000 - 607.90000000
Company
Fitness Audio Network P/L
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

O p e r a t i o n m a n u a l UTX-16 Rechargeable Belt-pack Transmitter 1 UTX-16 Rechargeable Belt-pack Transmitter Parts and functions of UTX-16 transmitter Menu button Setting button Battery compartment Power button Charging contacts Audio input connector for FITNESS AUDIO headset / lavalier / earworn microphone. Charging dock HC24 available separately. Cover release buttons LCD Low-impedance gain control High-impedance gain control 2 Instructions Battery installation & indicator When the transmitter is switched ON, the battery meter will display batteries’ condition. When using rechargeables, be sure to set battery type to NiMH in the menu. If displaying only one grid, the batteries are about to expire and require replacement (or charging when using NiMH rechargeables). This transmitter requires two AA batteries to operate. To install, open the battery cover and insert the batteries into the battery compartment. Note : Batteries contain a corrosive alkaline that may leak and damage the transmitter when storing without use for more than 4 weeks. Batteries should be removed when storing for long periods without use. Battery type setting 1 Use MENU button to go to the BATTERY TYPE page. 2 Press and hold SET button for 3 seconds, then the cursor  will flash to allow changes to be made. 3 Press SET button to select either NiMH (rechargeable battery) or AKLN (alkaline battery). 4 3 seconds after selecting a battery type, it will be automatically saved. Important: ◼ The transmitter will automatically shut down when charging in the charging dock (HC24). ◼ Do not charge primary batteries such as zink-carbon and alkaline batteries to avoid risks of leakage or explosion. ◼ Be sure to install the batteries by correct polarity to prevent device damages due to short circuit. ◼ Batteries of the same brand offer better quality consistency. Do not use batteries of different brands if possible. ◼ Do not mix new, old and different-brand batteries to prevent short circuit or malfunction. ◼ If the transmitter will not be used for a long period of time, the batteries should be removed and kept dry to avoid leakage and damage to the device due to battery self-discharge. ◼ If the battery leaks, cracks or deforms, stop using and take it out immediately and dispose with due consideration to the environment. 3 UTX-16 Rechargeable Belt-pack Transmitter Channel setting 1 Use MENU button to go to the CHANNEL|FREQUENCY page. 2 Press and hold the SET button for 3 seconds, then the channel block will flash to allow changes to be made. 3 Press MENU button to increase or SET button to decrease channel number. The corresponding frequency will change accordingly. The system provides 16 channels (0, 1, 2, 3, ... 9, A, B, ...,F) for selection. 4 3 seconds after selecting a group-channel, it will be automatically saved. Button lock & unlock 1 Use MENU button to go to the BUTTON LOCK page. 2 Press and hold SET button for 3 seconds, then the arrow  will flash to allow changes to be made. 3 Press SET or MENU button to switch between OFF (unlocked) and ON (locked). The SET button is disabled under ON status. 4 3 seconds after selecting a locking mode, it will be automatically saved. To enable the SET button, just repeat STEP 3. 4 Instructions GAIN setting (GT | MT) Gain control enables the user to set different output levels. (Multimics are affected by both.)  GT (LEFT) is for the use of instrument with high impedance, such as guitar. MT (RIGHT) is for the use of low impedance such as lapel or headset microphones. M E N U S E T M E N U S E T 5 UTX-16 Rechargeable Belt-pack Transmitter FITNESS AUDIO PRODUCTS ALSO INCLUDE: Fitness Audio U-Series UHF Wireless System Fitness Audio DX6 Wireless System Fitness Audio Aerolink AL3.0 Bluetooth Receiver Fitness Audio Aeromix AMX-1+1SR Stereo Voice-over-Music Mixer Fitness Audio Aeromix 2+2SR Voice-over-Music Mixer Fitness Audio Aeromix 3+5LS Stereo Voice-over-Music Mixer Fitness Audio HC24 Dual-Slot Charging Dock P O W E R L I N K A N T . M U S I C R E C E I V E R 5 6 Instructions Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: ⚫ Reorient or relocate the receiving antenna. ⚫ Increase the separation between the equipment and receiver. ⚫ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ⚫ Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 0.5 cm from all persons and must not be co-located or operatin…

Text truncated - open the document above for the full version.

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_03 06-06-2024 Fitness Audio Network P/L Certification Application Attestation Statements <Company name> Fitness Audio Network P/L <FRN:> 0025848938 <adress> Unit 17, 110 Bourke Rd, <ZIP / Postcode> Alexandria NSW 2015 <city> <country> Australia Subject: FCC ID: < 2AJMEUTX-16 > To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) 1. [Fitness Audio Network P/L] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. 2. [Fitness Audio Network P/L] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Fitness Audio Network P/L] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2025/12/05 City: Alexandria NSW 2015 Name (2) : Andrew Zarounas Function: Managing Partner Asia Pacific Telephone number: +61283991052 Email address: [email protected] Signature 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK”

Attestation Statements

Agent letter FCC attestation statement Kiwa Page 1 of 2 RF_753, Issue 4 17-07-2025 Fitness Audio Network P/L Unit 17, 110 Bourke Rd, Alexandria NSW 2015 Australia U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: Fitness Audio, LLC FRN: ☐ 10 digit number: ☒ The US Agent does not have a FRN because this person does not do business with the FCC Contact person name: Robert Holombo Street address: PO Box 1001 Santa Cruz ZIP/City/State CA 95061-1001 United States Telephone number: +831 258 1800 Email address: [email protected] Signature: Date: 2025/12/09 T his letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. T he Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. A pplicant Company name: Fitness Audio Network P/L FCC ID: 2AJME FRN: 0025848938 Contact person name: Andrew Zarounas Street address: Unit 17, 110 Bourke Rd, ZIP/City/State/Country Alexandria NSW 2015 Australia Telephone number: +61283991052 Email address: [email protected] Signature: Date: 2025/12/09

Cover Letter(s)

RF_160_06 Declaration of Authorisation Date of issue 13-08-2025 (On manufacturer’s company letter heading) Declaration of Authorization We Name: Fitness Audio Network P/L Address: Unit 17, 110 Bourke Rd, City: Alexandria NSW 2015 Country: Australia Declare that: Name Representative of agent: Chieh Tseng Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd. Address: 6F., No. 58, Ln. 188, Ruey-Kuang Rd., Neihu, City: Taipei City, Country Taiwan (R.O.C.) is authorized to apply for Certification of the following product(s): Product description: Wireless Microphone Transmitter Type designation: UTX-16 Trademark: Fitness Audio Validity/ expiry date on our behalf. Date: 2025/12/05 City: Alexandria NSW 2015 Name: Andrew Zarounas Function: Managing Partner Asia Pacific Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 1 of 2 Company Name: Fitness Audio Network P/L Address : Unit 17, 110 Bourke Rd, City: Alexandria NSW 2015 Country: Australia To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2AJMEUTX-16 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 2025/12/05 Name and signature of applicant: Andrew Zarounas Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 20 External Photos Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 20

ID Label/Location Info

UTX-16 FCC/IC ID/CE/RCM/UKCA流水黏貼位置圖 COMPANY FITNESS AUDIO DRAWING NO. 21425A01 DESCRIPTION 黏貼位置圖 CHIAYO ELECTRONICS CO., LTD. MODEL UTX-16 PART NO. DATE 2025/10/09 VERSION A DRAWER Antonio APPROVED UNIT SCALE 包裝提供(尺寸:30x12mm)

Internal Photos

Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 20 Internal Photos Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 20 Registration number: W6M22510-24753-FCC FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 20

RF Exposure Info

of Applicant: Fitness Audio Network P/L Address: Unit 17 The Bourke Centre, 110-116 Bourke Road, ALEXANDRIA, NSW 2015 Australia Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22510-24753-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for Wireless Microphone Transmitter Model No.: UTX-16 FCC ID: 2AJMEUTX-16 Registration number: W6M22510-24753-EE FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 6 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.3 APPLICATION DETAILS ................................................................................................................. 3 1.4 GENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.5 T EST STANDARDS ......................................................................................................................... 4 2 TEST CONFIGURATION .............................................................................................................. 5 2.1 TEST ENVIRONMENT .................................................................................................................... 5 2.2 MEASUREMENT UNCERTAINTY .................................................................................................... 5 2.3 T EST EQUIPMENT LIST ................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP)....................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION ACCORDING TO FCC KDB PUBLICATION ......... 6 Registration number: W6M22510-24753-EE FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 6 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: December 12, 2025 Sora Kuo Date WTS-Lab. Name Signature Technical responsibility for area of testing: December 12, 2025 Kevin Wang Date WTS Name Signature Registration number: W6M22510-24753-EE FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 6 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: Fitness Audio Network P/L Street: Unit 17 The Bourke Centre, 110-116 Bourke Road, Town: ALEXANDRIA, NSW 2015 Country: Australia Manufacturer: (if applicable) Name: CHIAYO ELECTRONICS CO., LTD. Street: No.88, Chung Hsiao Street 2, Town: Chiayi, Country: Taiwan, R.O.C. Date of receipt of test sample: November 21, 2025 Date of test: from November 24, 2025 to November 27, 2025 Registration number: W6M22510-24753-EE FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 6 1.4 General information of Test item Type of test item: Wireless Microphone Transmitter Model no.: UTX-16 Multi-listing model no.: ./. Brand name: Fitness Audio Power supply: Battery 3Vd.c. Type of antenna: PCB A ntenna Antenna gain: 0dBi Technical data Mode Frequency Conducted Power (dBm) 470-608 MHz 471.1 MHz -2.79 539 MHz 5.15 607.9 MHz 4.59 Operation modes: Simplex Modulation type: FSK Sample no.: #01 Classification: Fixed Device Mobile Device (Human Body distance > 20cm) Portable Device (Human Body distance < 20cm) Modular Radio Device 1.5 Test standards 47 CFR FCC Part 2 Subpart J, section 2.1093 FCC KDB Publication 447498 D01 General RF Exposure Guidance v06 Registration number: W6M22510-24753-EE FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 5 of 6 2 Test configuration 2.1 Test …

Text truncated - open the document above for the full version.

Test Report

of Applicant: Fitness Audio Network P/L Address: Unit 17 The Bourke Centre, 110 -116 Bourke Road, ALEXANDRIA, NSW 2015 Australia Tested and Prepared By Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22510-24753-C-1 6F., No. 58, Ln. 188, Rueiguang Rd., Neihu Dist., Taipei City , Taiwan (R.O.C.) TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for Wireless Microphone Transmitter Model No.: UTX-16 FCC ID: 2AJMEUTX-16 Registration number: W6M22510-24753-C-1 FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 25 TABLE OF CONTENTS CERTIFICATION OF TEST REPORT ................................................................................................................... 2 1 GENERAL INFORMATION ............................................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 T ESTING LABORATORY ................................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ................................................................................................... 3 1.4 APPLICATION DETAILS ................................................................................................................. 3 1.5 G ENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.6 TEST STANDARDS ......................................................................................................................... 4 2 TECHNICAL TEST ................................................................................................................................................. 5 2.1 SUMMARY OF TEST RESULTS ........................................................................................................ 5 2.2 TEST ENVIRONMENT .................................................................................................................... 5 2.3 TEST EQUIPMENT LIST ................................................................................................................. 6 2.4 GENERAL TEST PROCEDURE ........................................................................................................ 7 3 TEST RESULTS (ENCLOSURE) ...................................................................................................................... 8 4 RF POWER OUTPUT, FCC15.236 (D) ........................................................................................................... 9 4.1 TEST PROCEDURE ......................................................................................................................... 9 4.2 TEST RESULTS ........................................................................................................................... 10 5 OCCUPIED BANDWIDTH, FCC15.236 (F) / /EMISSION MASK, FCC15.236 (G) ................ 16 5.1 TEST PROCEDURE ...................................................................................................................... 16 5.2 TEST RESULTS ............................................................................................................................ 16 6 RADIATED SPURIOUS EMISSION , FCC 15.236(G) ...................................................................... 21 6.1 TEST PROCEDURE ....................................................................................................................... 21 6.2 TEST RESULTS ............................................................................................................................ 21 7 FREQUENCY STABILITY, FCC 15.236(F)(3) ......................................................................................... 22 7.1 TEST PROCEDURE ....................................................................................................................... 22 7.2 TEST RESULTS ............................................................................................................................ 22 8 LINE CONDUCTED EMISSION , FCC 15.207 ......................................................................................... 24 8.1 TEST PROCEDURE ....................................................................................................................... 24 8.2 TEST RESULTS ........................................................................................................................... 24 Registration number: W6M22510-24753-C-1 FCC ID: 2AJMEUTX-16 Worldwide Testing Services(Taiwan) Co., Ltd. page 2 of 25 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Service…

Text truncated - open the document above for the full version.

Test Report

Operator: Temperature:22.5 °C File :3Data :#1Date: 2025/11/21 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Sora Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:59.6 % Time: 上午 10:20:32 Condition : EUT : M/N: Note : Tx 539MHz ETSI EN300_422 V2.2.1-TX_Spurious_OP W6M22510-24753 Test Mode : Polarization: Horizontal Distance: 3m 3 Vd.c. Power : Mk. Frequency (MHz) Reading (dBm) Corr. factor (dB) Result (dBm) Limit (dBm) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *1078.156-48.58-47.78-30.00-18.58peak-0.80150135 1613.226-50.84-51.86-30.00-20.84peak1.0215070 *:Maximum data x:Over limit !:over margin Operator: Temperature:22.5 °C File :3Data :#2Date: 2025/11/21 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Sora Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:59.6 % Time: 上午 10:33:14 Condition : EUT : M/N: Note : Tx 539MHz ETSI EN300_422 V2.2.1-TX_Spurious_OP W6M22510-24753 Test Mode : Polarization: Vertical Distance: 3m 3 Vd.c. Power : Mk. Frequency (MHz) Reading (dBm) Corr. factor (dB) Result (dBm) Limit (dBm) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 1072.144-54.84-54.77-30.00-24.84peak-0.07150225 *1613.226-53.31-55.85-30.00-23.31peak2.54150140 *:Maximum data x:Over limit !:over margin Operator: Temperature:22.5 °C File :1Data :#1Date: 2025/11/23 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Sora Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:59.3 % Time: 上午 07:05:33 Condition : EUT : M/N: Note : Tx 607.9MHz ETSI EN300_422 V2.2.1-TX_Spurious_OP W6M22510-24753 Test Mode : Polarization: Horizontal Distance: 3m 3 Vd.c. Power : Mk. Frequency (MHz) Reading (dBm) Corr. factor (dB) Result (dBm) Limit (dBm) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *:Maximum data x:Over limit !:over margin Operator: Temperature:22.5 °C File :1Data :#3Date: 2025/11/23 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Sora Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:59.3 % Time: 上午 07:08:47 Condition : EUT : M/N: Note : Tx 607.9MHz ETSI EN300_422 V2.2.1-TX_Spurious_OP W6M22510-24753 Test Mode : Polarization: Vertical Distance: 3m 3 Vd.c. Power : Mk. Frequency (MHz) Reading (dBm) Corr. factor (dB) Result (dBm) Limit (dBm) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *:Maximum data x:Over limit !:over margin Operator: Temp…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Andrew Zarounas(Managing Partner Asia Pacific)
[email protected]Fax: +61 2 8399 3396

Technical Contact

Fitness Audio, LLCRobert Holombo
[email protected]

PO Box 1001 Santa Cruz · 95061-1001 · United States

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
115C471.1 MHz - 607.9 MHz-
Confidentiality
Long Term
Grant Notes
Power Output is conducted. This is a portable device. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.