FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. 3Plus International Inc./
  3. 2AJVH-3PL-L42A

2AJVH-3PL-L42ASports Bracelet

3Plus International Inc.
Sports Bracelet - FCC ID 2AJVH-3PL-L42A - 3Plus International Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 17, 2021
Application Purpose
Original Equipment
Date of Application
Jan 17, 2021
Equipment Note
Sports Bracelet
Frequency Range
2402.00000000 - 2480.00000000
Company
3Plus International Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCC ID: 2AJVH-3PL-L42A FCC ID: 2AJVH-3PL-L42A FCC ID: 2AJVH-3PL-L42A FCC ID: 2AJVH-3PL-L42A

ID Label/Location Info

FCC ID:2AJVH-3PL-L42A

Internal Photos

FCC ID: 2AJVH-3PL-L42A FCC ID: 2AJVH-3PL-L42A Antenna

RF Exposure Info

RF Exposure evaluation FCC ID: 2AJVH-3PL-L42A 1.1. Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 1.2. Requirement According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 1.3. Manufacturing tolerance BT LE-GFSK Channel Channel 00 Channel 39 Channel 78 Target (dBm) -3.0 -3.0 -4.0 Tolerance ±(dB) 1.0 1.0 1.0 2. E v a l u a t i o n R e s u l t Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power (including tune-up tolerance) SAR Test Exclusion Threshold SAR Test Exclusion dBm mW BT 2.480 5 -2 0.6310 0.2<3.0 Yes 3. C o n c l u s i o n The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06, No SAR is required. .....................End.........................

Test Report

Page1of33ReportNo.:UNIA20111101ER-01 FCCRADIOTESTREPORT FCCID:2AJVH-3PL-L42A Product: SportsBracelet TradeName: ModelName: L42A SerialModel: Vibe+,3PLUS-VIBE,3PLUS Vibe+ ReportNo.: UNIA20111101ER-01 Preparedfor 3PlusInternationalInc. 1502FoothillBlvdSuite103-260,LaVerne,California,UnitedStates,91750. Preparedby ShenzhenUnitedTestingTechnologyCo.,Ltd. 2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Page2of33ReportNo.:UNIA20111101ER-01 TESTRESULTCERTIFICATION Applicant’sname .................... : 3PlusInternationalInc. Address ...................................... : 1502FoothillBlvdSuite103-260,LaVerne,California,United States,91750. Manufacture'sName..............: 3PlusInternationalInc. Address ...................................... : 1502FoothillBlvdSuite103-260,LaVerne,California,United States,91750. Productdescription Productname...............................: SportsBracelet TradeMark ................................. : Modeland/ortypereference . : L42A,Vibe+,3PLUS-VIBE,3PLUSVibe+ Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.247, ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest...............................................: Date(s)ofperformanceoftests...............:Jan.04~11,2021 DateofIssue .............................................. :Jan.12,2021 TestResult..................................................:Pass Testedby: Bobliao/Editor Reviewer: Kahnyang/Supervisor Approved&AuthorizedSigner: Liuze/Manager Page3of33ReportNo.:UNIA20111101ER-01 TableofContentsPage 1.TESTSUMMARY...................................................................................................................5 1.1TESTPROCEDURESANDRESULTS..................................................................................5 1.2TESTFACILITY..........................................................................................................................5 1.3MEASUREMENTUNCERTAINTY..........................................................................................5 2.GENERALINFORMATION ................................................................................................... 6 2.1GENERALDESCRIPTIONOFEUT.......................................................................................6 2.2CarrierFrequencyofChannels...............................................................................................7 2.3OperationofEUTduringtesting..............................................................................................7 2.4DESCRIPTIONOFTESTSETUP...........................................................................................7 2.5MEASUREMENTINSTRUMENTSLIST................................................................................8 3.CONDUCTEDEMISSIONSTEST.......................................................................................9 3.1ConductedPowerLineEmissionLimit ..................................................................................... 9 3.2TestSetup ..................................................................................................................................... 9 3.3TestProcedure ............................................................................................................................. 9 3.4TestResult .................................................................................................................................... 9 4.RADIATEDEMISSIONTEST.............................................................................................12 4.1RadiationLimit...........................................................................................................................12 4.2TestSetup...................................................................................................................................12 4.3TestProcedure...........................................................................................................................13 4.4TestResult..................................................................................................................................13 5.BANDEDGE ......................................................................................................................... 18 5.1Limits...........................................................................................................................................18 5.2TestProcedure...........................................................................................................................18 5.3TestResult..................................................................................................................................18 6.OCCUPIEDBANDWIDTHMEASUREMENT..................................................................20 6.1TestLimit ..................................................................................................................................... 20 6.2TestProcedure ........................................................................................................................... 20 6.3MeasurementEquipmentUsed ............................................................................................... 20 6.4TestResult .................................................................................................................................. 20 7.POWERSPECTRALDENSITYTEST..............................................................................22 7.1TestLimit...........................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AJVH-3PL-L42A Radiated Emission (Below 1G) Radiated Emission (Above 1G) FCC ID: 2AJVH-3PL-L42A Conducted Emission

Contact Information

Applicant

Yau Hwa Chan(Account Executive)
[email protected]909-447-8369Fax: 909-447-8366

Test Firm

Shenzhen United Testing Technology Co., Ltd.Liu Ze
[email protected]86-755-86180996

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz500.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from 3Plus International Inc.

2AJVH-LIRA

SMART WATCH

Sep 28, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
3Plus Loop Smart Ring - FCC ID 2AJVH-LOOP - 3Plus International Inc.
2AJVH-LOOP

3Plus Loop Smart Ring

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Smart Watch - FCC ID 2AJVH-MEGA - 3Plus International Inc.
2AJVH-MEGA

Smart Watch

Mar 09, 2024

Equipment Class

DTS - Digital Transmission System
Smart Watch - FCC ID 2AJVH-CALLIE - 3Plus International Inc.
2AJVH-CALLIE

Smart Watch

Mar 09, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smart Watch - FCC ID 2AJVH-HELIO - 3Plus International Inc.
2AJVH-HELIO

Smart Watch

Feb 07, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter