FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Secukey Technology Co., Ltd./
  3. 2AJWY-XK6-RX

2AJWY-XK6-RXAccess Control

Secukey Technology Co., Ltd.
Access Control - FCC ID 2AJWY-XK6-RX - Secukey Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 10, 2024
Application Purpose
Original Equipment
Date of Application
Jan 10, 2024
Equipment Note
Access Control
Frequency Range
0.12500000 - 0.12500000
Company
Secukey Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving an tenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Attestation Statements

-SecukeyTechnologyCo.,Ltd- TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotifytheFCCwithin30daysvia thegrantingTCB. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 12/28/23 U.S.AgentDesignation SecukeyTechnologyCo.,Ltdacknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationis sought(FCCID:2AJWY-XK6-RX) NameandcompanyofU.S.agent:LinkwldLLC PhysicalU.S.addressofagent:1942BroadwaySt.STE314C,Boulder,CO,80302,US FRNofU.S.agent:0033625682 EmailaddressofU.S.agent:[email protected] LinkwldLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfofSecukey TechnologyCo.,Ltd. SecukeyTechnologyCo.,LtdwiththeFRN0025919978acceptsitsobligationtomaintainanagentfor serviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,or theconclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingthe equipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(d)(7). Sincerely, Signature [Name]Windy [Title]Manager [Company]SecukeyTechnologyCo.,Ltd Signature [NameofU.S.agent]TimothyZhu [TitleofU.S.agent]Manager [CompanyofU.S.agent]LinkwldLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 4

Attestation Statements

-SecukeyTechnologyCo.,Ltd.- TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB986446D01. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 1/8/24 Towhomitmayconcern: We,[SecukeyTechnologyCo.,Ltd.],herebycertifythattheequipmentforwhichauthorizationis sought(FCCID:[2AJWY-XK6-RX])isnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuantto§2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,wearenotidentifiedontheCovered List(https://www.fcc.gov/supplychain/coveredlist)asanentityproducing“covered”equipment. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirements listedunder§2.911(b)and(d)(5)and(6). Sincerely, Signature [IvyDeng] [Sales] [SecukeyTechnologyCo.,Ltd.] 6 2 _ [ m o d e l ] C o v e r e d E q u _ 2 . 9 1 1 ( d ) ( 5 ) ( i ) a n d ( i i ) - U , V 0 2

External Photos

ProjectNo.:18220WC302650Page1of3 Code:AB-RF-05-b AppendixII--ExternalPhotograph ProjectNo.:18220WC302650Page2of3 Code:AB-RF-05-b ProjectNo.:18220WC302650Page3of3 Code:AB-RF-05-b

ID Label/Location Info

LabelLocation: ProductName:AccessControl ModelNo.:XK6-RX FCC:2AJWY-XK6-RX

Internal Photos

ProjectNo.:18220WC302650Page1of3 Code:AB-RF-05-b AppendixIII--InternalPhotograph ProjectNo.:18220WC302650Page2of3 Code:AB-RF-05-b 13.56MHzANT 125kHzANT ProjectNo.:18220WC302650Page3of3 Code:AB-RF-05-b

RF Exposure Info

FCCID:2AJWY-XK6-RX RFEXPOSUREEVALUATION EUTSpecification EUTAccessControl ModelName XK6-RX,XK5-RX,X5-RX,X6-RX,S5-X,S6-X,S9-X,S9, CR9-R,CR9-RX,CR9,CK9-REM,CK9-RMF,CK9-R, CK9-RX,CK9,CR4,CR5,CR6,CH4,CH5,CH6,CF4, CF5,CF6,CHD4,CHD5,CHD6,CFD4,CFD5,CFD6,CK4, CK5,CK6,SK13,SK14,H4-KEY Frequencyband (Operating) WLAN:2.412GHz~2.462GHz WLAN:5.18GHz~5.32GHz/5.50GHz~5.70GHz WLAN:5.745GHz~5825GHz Others(13.56MHz,125KHz) DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Max.outputpower13.56MHz:56.01dBuV/m(-39.248dBm)(0.00012mW) 125KHz:56.85dBuV/m(-38.408dBm)(0.00014mW) Antennagain0dBi EvaluationappliedMPEEvaluation SAREvaluation StandardRequirement PortableDevice Accordingto§15.247(i)and§1.1307b(1),systemsoperatingundertheprovisionsofthissection shallbeoperatedinamannerthatensuresthatthepublicisnotexposedtoradiofrequency energylevelsinexcessoftheCommission’sguidelines.SeeKDB447498D01GeneralRF ExposureGuidanceV6,section4.3.1. The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distances ≀ 50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)] · [ √ f(GHz)] ≀ 3.0for1-gSARand ≀ 7.5for10-gextremitySAR, 16 where · f(GHz)istheRFchanneltransmitfrequencyinGHz · PoweranddistanceareroundedtothenearestmWandmmbeforecalculation17 FCCID:2AJWY-XK6-RX ·Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≀50 mmandfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion. MeasurementResult Channel Frequency (GHz) MaxOutput power (dBm) Maxtune-up tolerance Outputpower (dBm) MaxOutput power (dBm) MaxOutput power (mW) Calculation Value (Note1) Threshold Value 0.01356-39.248-39.248±1-38.2480.000150.0000033.0 0.000125-38.408-38.408±1-37.4080.000180.00000043.0 EIRP=E-104.8+20logD=56.01-104.8+20log3=-39.248dbm Note1:CalculationValue=[(max.powerofchannel,mW)/(min. testseparationdistance,mm)]·[√f(GHz)]. Foxexample:0.00015/5*√0.01356=0.000003≀3.0 EIRP=E-104.8+20logD=56.85-104.8+20log3=-38.408dbm Note1:CalculationValue=[(max.powerofchannel,mW)/(min. testseparationdistance,mm)]·[√f(GHz)]. Foxexample:0.00018/5*√0.000125=0.0000004≀3.0 AccordingtoKDB447498D01V6,thresholdatwhichnoSARrequiredis≀3.0for1-gSAR, separationdistanceis5mm,andnosimultaneousSARmeasurementisrequired. TheSARmeasurementisnotnecessary.

Test Report

ReportNo.:18220WC30265002FCCID:2AJWY-XK6-RXPage1of22 Code:AB-RF-05-b FCCTestReport Applicant:SecukeyTechnologyCo.,Ltd. Address: Floor5,Building13,LongbiIndustrialPark, LonggangDistrict,Shenzhen,China ProductName:AccessControl ReportDate:Jan.10,2024 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC30265002FCCID:2AJWY-XK6-RXPage2of22 Code:AB-RF-05-b Contents 1.GeneralInformation..............................................................................................................................................5 1.1.ClientInformation.......................................................................................................................................5 1.2.DescriptionofDevice(EUT)....................................................................................................................5 1.3.AuxiliaryEquipmentUsedDuringTest...................................................................................................6 1.4.DescriptionofTestConfiguration............................................................................................................6 1.5.DescriptionOfTestSetup.........................................................................................................................7 1.6.TestEquipmentList...................................................................................................................................7 1.7.MeasurementUncertainty........................................................................................................................9 1.8.DescriptionofTestFacility........................................................................................................................9 1.9.Disclaimer.................................................................................................................................................10 2.SummaryofTestResults...................................................................................................................................11 3.ConductedEmissionTest..................................................................................................................................12 3.1.TestStandardandLimit..........................................................................................................................12 3.2.TestSetup.................................................................................................................................................12 3.3.TestProcedure.........................................................................................................................................12 3.4.TestData...................................................................................................................................................12 4.RadiationSpuriousEmissionandBandEdge...............................................................................................15 4.1.TestStandardandLimit..........................................................................................................................15 4.2.TestSetup.................................................................................................................................................15 4.3.TestProcedure.........................................................................................................................................16 4.4.TestData...................................................................................................................................................16 5.AntennaRequirement.........................................................................................................................................21 5.1.TestStandardandRequirement...........................................................................................................21 5.2.AntennaConnectedConstruction.........................................................................................................21 APPENDIXI--TESTSETUPPHOTOGRAPH..................................................................................................22 APPENDIXII--EXTERNALPHOTOGRAPH.....................................................................................................22 APPENDIXIII--INTERNALPHOTOGRAPH.....................................................................................................22 ReportNo.:18220WC30265002FCCID:2AJWY-XK6-RXPage3of22 Code:AB-RF-05-b TESTREPORT Applicant:SecukeyTechnologyCo.,Ltd. Manufacturer:SecukeyTechnologyCo.,Ltd. ProductName:AccessControl TestModelNo.:XK6-RX ReferenceModelNo.: XK5-RX,X5-RX,X6-RX,S5-X,S6-X,S9-X,S9,CR9-R,CR9-RX,CR9, CK9-REM,CK9-RMF,CK9-R,CK9-RX,CK9,CR4,CR5,CR6,CH4,CH5, CH6,CF4,CF5,CF6,CHD4,CHD5,CHD6,CFD4,CFD5,CFD6,CK4, CK5,CK6,SK13,SK14,H4-KEY TradeMark: Secukey Rating(s): Input:12-18V⎓ TestStandard(s): FCCPart15SubpartC,Paragraph15.209 TestMethod(s): ANSIC63.10:2020 ThedevicedescribedaboveistestedbyShenzhenAnbotekComplianceLaboratoryLimitedto determinethemaximumemissionlevelsemanatingfromthedeviceandtheseverelevelsofthedevice canendureanditsperformancecriterion.Themeasurementresultsarecontainedinthistestreportand ShenzhenAnbotekComplianceLaboratoryLimitedisassumedfullofresponsibilityfortheaccuracy andcompletenessofthesemeasurements.Also,thisreportshowsthattheEUT(EquipmentUnder Test)istechnicallycompliantwiththeFCCPart15SubpartCrequirements. Thisreportappliestoabovetestedsampleonlyandshallnotbereproducedinpartwithoutwritten approvalofShenzhenAnbotekComplianceLaboratoryLimited. DateofReceiptDec.12,2023 DateofTestDec.12,2023~Jan.10,2024 PreparedBy (EllaLiang) Approved&AuthorizedSigner (EdwardPan) ReportNo.:18220WC30265002FCCID:2AJWY-XK6-RXPage4of22 Code:AB-RF-05-b RevisionHistory ReportVersionDescriptionIssuedDate R00OriginalIssue.Jan.10,2024 ReportNo.:18220WC30265002FCCID:2AJWY-XK6-RXPage5of22 Code:AB-RF-05-b 1.GeneralInformation 1.1.ClientInformation Applicant:SecukeyTechnologyCo.,Ltd. A


Text truncated - open the document above for the full version.

Test Report

version01 SecukeyTechnologyCo.,Ltd. DeclarationconcerningAntennaSpecification Itisherebydeclaredthattheproduct ModelNo.:XK6-RX,XK5-RX,X5-RX,X6-RX,S5-X,S6-X,S9-X,S9,CR9-R,CR9-RX,CR9, CK9-REM,CK9-RMF,CK9-R,CK9-RX,CK9,CR4,CR5,CR6,CH4,CH5,CH6,CF4, CF5,CF6,CHD4,CHD5,CHD6,CFD4,CFD5,CFD6,CK4,CK5,CK6,SK13,SK14,H4- KEY FCCID:2AJWY-XK6-RX fulfillstherequirementinFCCtestrelatingtotheantennatype. ThedevicespecifiedaboveconfirmstotheFCCrecommendationsforinternalantennatype(s) describedbelow: ModelNo.ofantenna:XK6-ANT Typeofantenna:PCBAntenna Gainoftheantenna:0dBi Frequencyrange:13.56MHz ModelNo.ofantenna:XK2-ANT Typeofantenna:InductiveloopcoilAntenna Gainoftheantenna:0dBi Frequencyrange:125kHz Themountingoftheantennaisfixedtotheradiomoduleandnootherantennashouldbeused. Companyname:SecukeyTechnologyCo.,Ltd. Address:Floor5,Building13,LongbiIndustrialPark,LonggangDistrict,Shenzhen, China City:Shenzhen ZIP/Postalcode:/ Country:China Place:ShenzhenDate:1/8/2024 Signature:

Test Report

EM Antenna Specifications Material Name:AntennaModel:XK2 -ANTInternal No.:4.002.153 1. Dimensions 2. Product physical picture 3. Circuit schematic4. Antenna gain:0 5. Electrical performance parameters Wire Diameter:0.2MMInductance:560UHCoil Turns:48T Lead Wire Method:Tin on the LeadsLead Length:30MMTest Instrument:Digital Bridge 6. Manufacturer: Secukey Technology Co., Ltd. 5. Frequency Range 125KHz

Test Setup Photos

ProjectNo.:18220WC302650Page1of2 Code:AB-RF-05-b AppendixI--TestSetupPhotograph ConductedEmissionatACpowerline PhotoofRadiationEmissionTest(below30MHz) ProjectNo.:18220WC302650Page2of2 Code:AB-RF-05-b PhotoofRadiationEmissionTest(30MHzto1GHz)

Contact Information

Applicant

Ivy Deng(Sales)
[email protected]0755-26795455Fax: 0755-26795454

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]13798230942

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Secukey Technology Co., Ltd.

RFID Reader - FCC ID 2AJWY-S1-RX - Secukey Technology Co., Ltd.
2AJWY-S1-RX

RFID Reader

Apr 27, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz