2AKBP-Q3CWMSmart Light Bulb

Shenzhen Hysiry Technology Co., Ltd.
Smart Light Bulb - FCC ID 2AKBP-Q3CWM - Shenzhen Hysiry Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 01, 2020
Application Purpose
Original Equipment
Date of Application
Mar 31, 2020
Equipment Note
Smart Light Bulb
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Hysiry Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization ShenzhenHysiryTechnologyCo.,Ltd. Company:ShenzhenHysiryTechnologyCo.,Ltd. Address:2403D,24thfloor,coasthuanqingbuilding,no.24futianroad, xutowncommunity,futianstreet,futiandistrict,shenzhen ProductName:SmartLightBulb ModelNumber:Q3CWM FCCIdentifier:2AKBP-Q3CWM WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:HaitaoZhanDate:2020-03-31 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 ShenzhenHysiryTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2020-03-31 Subject:RequestforConfidentiality FCCID:2AKBP-Q3CWM ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:HaitaoZhan Title:Manager

External Photos

GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page1of1 ProductName:SmartLightBulb TestModelNo.:Q3CWM EUTConstructionalDetails -----End------

Internal Photos

GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page1of3 ProductName:SmartLightBulb TestModelNo.:Q3CWM EUTConstructionalDetails RFAntenna GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page2of3 GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page3of3 ------End------

RF Exposure Info

FCCID:2AKBP-Q3CWM RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation WI-FIMode: TestModeChannel Outputpowerto antenna(mW) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b Lowest(2412MHz)104.710.030811.0PASS Middle(2437MHz)91.410.026901.0PASS Highest(2462MHz)67.760.019941.0PASS 802.11g Lowest(2412MHz)75.340.022171.0PASS Middle(2437MHz)68.080.020031.0PASS Highest(2462MHz)49.660.014611.0PASS 802.11n(HT20) Lowest(2412MHz)82.220.024201.0PASS Middle(2437MHz)68.870.020271.0PASS Highest(2462MHz)51.880.015271.0PASS 802.11n(HT40) Lowest(2422MHz)72.950.021471.0PASS Middle(2437MHz)65.770.019351.0PASS Highest(2452MHz)55.210.016251.0PASS Remark:antennagain=1.7dBi

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS202003000219F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 55 TEST REPORT Applicant: Shenzhen Hysiry Technology Co., Ltd. Address of Applicant: 2403D, 24th floor, coast huanqing building, no.24 futian road, xu town community, futian street, futian district, shenzhen Manufacturer: Shenzhen Hysiry Technology Co., Ltd. Address of Manufacturer: 2403D, 24th floor, coast huanqing building, no.24 futian road, xu town community, futian street, futian district, shenzhen Equipment Under Test (EUT) Product Name: Smart Light Bulb Model No.: Q3CWM Trade Mark: FCC ID: 2AKBP-Q3CWM Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 2019-12-23 Date of Test: 2019-12-25 to 2020-03-25 Date of report issued: 2020-03-25 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202003000219F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 55 2 Version Version No. Date Description 00 2020-03-25 Original Prepared By: Date: 2020-03-25 Project Engineer Check By: Date: 2020-03-25 Reviewer Report No.: GTS202003000219F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 55 3 Contents Page 1 COVER PAGE ................................................................................................................................................. 1 2 VERSION ----------------------------------------------------------------------------------------------------------------------------- 2 3 CONTENTS -------------------------------------------------------------------------------------------------------------------------- 3 4 TEST SUMMARY ------------------------------------------------------------------------------------------------------------------ 4 5 GENERAL INFORMATION ------------------------------------------------------------------------------------------------------ 5 5.1 GENERAL DESCRIPTION OF EUT -------------------------------------------------------------------------------------------- 5 5.2 TEST MODE ---------------------------------------------------------------------------------------------------------------------- 6 5.3 DESCRIPTION OF SUPPORT UNITS ------------------------------------------------------------------------------------------- 6 5.4 DEVIATION FROM STANDARDS ------------------------------------------------------------------------------------------------ 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS -------------------------------------------------------------------------- 6 5.6 TEST FACILITY ------------------------------------------------------------------------------------------------------------------ 6 5.7 TEST LOCATION----------------------------------------------------------------------------------------------------------------- 6 5.8 ADDITIONAL INSTRUCTIONS --------------------------------------------------------------------------------------------------- 6 6 TEST INSTRUMENTS LIST ----------------------------------------------------------------------------------------------------- 7 7 TEST RESULTS AND MEASUREMENT DATA --------------------------------------------------------------------------- 9 7.1 ANTENNA REQUIREMENT ------------------------------------------------------------------------------------------------------ 9 7.2 CONDUCTED EMISSIONS -----------------------------------------------------------------------------------------------------10 7.3 CONDUCTED PEAK OUTPUT POWER ---------------------------------------------------------------------------------------13 7.4 CHANNEL BANDWIDTH & 99% OCCUPY BANDWIDTH -------------------------------------------------------------------16 7.5 POWER SPECTRAL DENSITY -------------------------------------------------------------------------------------------------20 7.6 BAND EDGES -------------------------------------------------------------------------------------------------------------------23 7.6.1 Conducted Emission Method ---------------------------------------------------------------------------------------23 7.6.2 Radiated Emission Method -----------------------------------------------------------------------------------------26 7.7 SPURIOUS EMISSION ----------------------------------------------------------------------------------------------------------43 7.7.1 Conducted Emission Method ---------------------------------------------------------------------------------------43 7.7.2 Radiated Emission Method -----------------------------------------------------------------------------------------45 8 TEST SETUP PHOTO -----------------------------------------------------------------------------------------------------------55 9 EUT CONSTRUCTIONAL DETAILS -----------------------------------------------------------------------------------------55 Report No.: GTS202003000219F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 55 4 Test Summary Test Item Section Result Antenna requirement FCC part 15.203/15.247 (c) Pass AC Power Line Conducted Emission FCC part 15.2…

Text truncated - open the document above for the full version.

Test Setup Photos

GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page1of2 ProductName:SmartLightBulb TestModelNo.:Q3CWM TestSetupPhoto RadiatedEmission GTS202003000219F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page2of2 ConductedEmission ------End------

Contact Information

Applicant

Haitao Zhan(Manager)
[email protected]0755-23064704Fax: (86) 755-23596457

Technical Contact

Shenzhen Hysiry Technology Co., Ltd.Haitao Zhan
[email protected]86-0755-23064704

Shenzhen Β· China

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz104.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance. The device contains 20MHz and 40MHz bandwidth.

Other Applications from Shenzhen Hysiry Technology Co., Ltd.

Smart string Lights - FCC ID 2AKBP-HELLOFAIRY1 - Shenzhen Hysiry Technology Co., Ltd.
2AKBP-HELLOFAIRY1

Smart string Lights

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System
Smart string lights - FCC ID 2AKBP-HELLOFAIRY - Shenzhen Hysiry Technology Co., Ltd.
2AKBP-HELLOFAIRY

Smart string lights

Aug 05, 2024

Equipment Class

DTS - Digital Transmission System
Smart string Lights - FCC ID 2AKBP-AESL37 - Shenzhen Hysiry Technology Co., Ltd.
2AKBP-AESL37

Smart string Lights

Dec 16, 2023

Equipment Class

DTS - Digital Transmission System
CLASS 2 POWER SUPPLY - FCC ID 2AKBP-PLUGIN - Shenzhen Hysiry Technology Co., Ltd.
2AKBP-PLUGIN

CLASS 2 POWER SUPPLY

Nov 06, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Fairy Lights - FCC ID 2AKBP-MSL8 - Shenzhen Hysiry Technology Co., Ltd.
2AKBP-MSL8

Smart Fairy Lights

Jan 06, 2021

Equipment Class

DTS - Digital Transmission System