FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Kane USA Inc./
  3. 2AKE4WHP3

2AKE4WHP3Wireless Hygrometer Probe

Kane USA Inc.
Wireless Hygrometer Probe - FCC ID 2AKE4WHP3 - Kane USA Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 17, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Hygrometer Probe
Frequency Range
2402.00000000 - 2480.00000000
Company
Kane USA Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HUB8 HUB6 HUB4 INSTRUCTION MANUAL ENGLISH Wireless Refrigerant Probes HUB8 Includes 2 Wireless Hygrometer Probe 2 Wireless Pressure Probe 2 Wireless Pipe Clamp 1 Wireless Outside Temperature Probe 1 Wireless Vacuum Gauge 14 Batteries (10 AA, 4 AAA) 1 45 ̊ Coupler 1 Carrying Case HUB6 Includes 2 Wireless Hygrometer Probe 2 Wireless Pressure Probe 2 Wireless Pipe Clamp 10 Batteries (6 AA, 4 AAA) 1 Carrying Case HUB4 Includes 2 Wireless Pressure Probe 2 Wireless Pipe Clamp 6 Batteries (AA) 1 Carrying Case 1-800-547-5740 www.ueitest.com • email: [email protected] KEEPING HOMES & WORKPLACES SAFE & COMFORTABLE Download and install the UEi HUB App Available on Google Play and The App Store NUAL 2 IMPORTANT SAFETY WARNINGS & PRECAUTIONS TABLE OF CONTENTS Important Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Wireless Hygrometer Probe Overview . . . . . . . . . . . . . . . . . . 3 Wireless Pressure Probe Overview . . . . . . . . . . . . . . . . . . . . 4 Wireless Pipe Clamp Overview . . . . . . . . . . . . . . . . . . . . . . . . 5 Wireless Outside Temperature Probe Overview . . . . . . . . . 6 Wireless Vacuum Gauge Overview . . . . . . . . . . . . . . . . . . . . . 6 Probe Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 FCC/IC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 HUB probes are designed for Indoor and Outdoor use. WARNING Read entire Safety Notes section regarding potential hazard and proper instructions before using these probes. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage the instruments. WARNING To ensure safe operation and service of these probes, follow these instructions. Failure to observe these warnings can result in severe injury or death. These probes are designed for trade professionals who are familiar with the hazards of their trade. • Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) • Observe all recommended safety procedures that include proper lockout utilization and use of personal protective equipment that includes safety glasses, gloves and flame resistant clothing. WARNING Do Not exceed the following maximum pressure limits. WVG2 Vacuum Gauge maximum over pressure 700 psi. WPP2 and WPP3 Pressure Gauge maximum over pressure 725 psi. CAUTION • Do not open WPP3 or WPP2 probes to replace batteries while the probes are connected. • To avoid false readings, replace batteries if a low battery indicator appears. • Use batteries that meet the specified requirements. • If there is any leakage or abnormality with the battery, handle it immediately and clean the instrument. • Do not expose probes to extreme high or low temperatures, humidity, or corrosive environments. • Avoid placing the probes in direct sunlight or high-vibration environments. • Do not use these probes if they appear damaged. In case of malfunction or damage, stop using probes immediately and contact technical support. 3 Hygrometer Overview (WHP3, WHP1) A. Lock Button: Press to unlock and open probe. Move to 90° or 180° until it locks in place. Press button again to unlock and rotate back to closed position. B. 1/4” diameter probe C. Magnetic Mount D. Battery Cover E. Status Light (WHP1 only) Blinks GREEN when probe is powered on. Blinks RED when battery is low (Low battery indication is also visible in app Toolbox screen). F. LCD Display (WHP3 only) Display (rotates through measurements...) CAUTION: Press down Lock Button to release probe. Failure to do so may break probe and is not covered under warranty . Battery Replacement CAUTION: Take care not to lose screws when opening battery compartments •Remove battery cover. •Replace the old batteries with 2 new (AAA) batteries. •Replace the battery cover. See probe specifications on page 7 WHP1 Wireless Hygrometer Probe E. B. A. C. D. Screw WHP3 Wireless Hygrometer Probe F. Connecting Probes WHP3/WHP1 work in the AIR screen. A. Select "Toolbox" icon in upper left corner. B. In Toolbox screen, probes appear in the “Nearby Tools" list. Tap "Refresh" icon if powered on probes don't appear. C. Available probes appear in list. D. Touch and Hold a probe to select for connection. E. Drag the probe to the matching probe icon for either "Return" or "Supply" slot assignment and release. Repeat with other probe. F. The UEi HUB will remember the assignment and automatically connect in future. G. Once connected, Tap the "back arrow" < icon to return Home to view measurements A.B. C.D.E.F.G. WHP1WHP3 4 Pressure Probe Overview (WPP3, WPP2) A. Battery cover B. Status Light (WPP2 only) Blinks GREEN when probe is powered on. Blinks RED when battery is low (Low battery indication is also visible in app Toolbox screen). C. Power Button: Press to Power On Press & Hold for 1 second and release to Power Off (WPP3 only) Press & Hold for 5 seconds, UNIT appears Press & Hold for 2 seconds to switch UNITS Press & Hold for 5 seconds, to exit UNIT D. 1/4”pressure connector E. 1/4” pass-through connector F. LCD Display (WPP3 only) Display rotates through measurements CAUTION: Max over pressure is 725 PSI Battery Replacement CAUTION: Take care not to lose the screws when opening battery compartments • Remove battery cover. • Replace old batteries with 2 new AA batteries. • Replace the battery cover. See probe specifications on page 8 A. B. C. D. E. Screw WPP3 Wireless Pressure Probe WPP2 WPP3 F. Connecting Probe…

Text truncated - open the document above for the full version.

Attestation Statements

Rev1/26/2023 (KANEUSAINC.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026.8.12 Ref:AttestationStatementsPart2.911(d)(7)Filing FCCID:[2AKE4WHP3] ApplicantFRN:[0026049338] [KANEUSAINC.](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,[KANEUSA INC.]isourdesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID.[KANEUSA INC. ]acceptstomaintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanyCommission-relatedproceedinginvolvingthe equipment. [ KANEUSAINC. ]accepts,asofthedateofthefilingoftheapplication,theobligationofthedesignated U.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:[KANEUSAINC.] U.S.AgentFRN:[0026049338] Address:[7601E.88thPlaceSte.888IndianapolisIndianaUnitedStates46256] ContactPerson:[Lindali] Tel.:[800-547-5740] Email:[[email protected]] Sincerely, [KANEUSAINC.][KANEUSAINC.] [Lindali][Lindali] [InsertApplicantsignature][U.S.Agentsignature]

Attestation Statements

(KANEUSAINC.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026.8.12 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AKE4WHP3 [KANEUSAINC.](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. [KANEUSAINC.](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnot includecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (Lindali) (KANEUSAINC.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026.8.12 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AKE4WHP3 [ KANEUSAINC. ](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) ( Lindali )

Cover Letter(s)

Rev11/20/07 FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2AKE4WHP3 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName (BlockDiagram,Schematics,Operational Description,) (SCH,BlockDiagram,TechnicalDescription,) Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName (() Sincerely, (signature) (printedname)Lindali Date:2026/08/12

Cover Letter(s)

C:\Users\kdyuan\Desktop\kate资料\Areport\POA_Letter.docx KANEUSAINC. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:2026.8.12 SUBJECT:FCCApplicationforFCCID:2AKE4WHP3 ToWhomItMayConcern: We,theundersigned,herebyauthorize_EdwinYeby_BureauVeritasShenzhenCo.,Ltd. DongguanBranch___at__No.96,ChenwuluSection,GuantaiRd.,HoujieTown, DongguanCity,Guangdong523942,Chinaonourbehalf,toapplytotheFederal CommunicationsCommissiononourequipment.AnyandallactscarriedoutbyEdwin Yeby_BureauVeritasShenzhenCo.,Ltd.DongguanBranchonourbehalfshallhavethe sameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Lindali

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version A Reference No.: 2603WDG0470 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version A Reference No.: 2603WDG0470 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version A Reference No.: 2603WDG0470

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 5 Report Version A Reference No.: 2603WDG0470 PHOTOGRAPHS OF THE EUT BT ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 5 Report Version A Reference No.: 2603WDG0470 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 5 Report Version A Reference No.: 2603WDG0470 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 5 Report Version A Reference No.: 2603WDG0470 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 5 Report Version A Reference No.: 2603WDG0470

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 9 Report Version A Test Report No.: FM2603WDG0470 RF EXPOSURE REPORT Applicant KANE USA INC. Address 7601 E. 88th Place Ste. 888 Indianapolis Indiana United States 46256 Manufacturer or Supplier ePlus Innovation Corp. Address 2F., No.19, Ancheng St., Xindian Dist., New Taipei City 23154, Taiwan China. Product Wireless Hygrometer Probe Brand Name UEi Test Instruments Model WHP3 Additional Model & Model Difference N/A Date of tests May 12, 2026 ~ May 15, 2026 The submitted sample of the above equipment has been tested according to the requirements of the following standard: FCC Part 2 (Section 2.1093) KDB 447498 D04 Interim General RF Exposure Guidance v01 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Bill Xie Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Aug. 25, 2026 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 9 Report Version A Test Report No.: FM2603WDG0470 TABLE OF CONTENTS RELEASE CONTROL RECORD ..................................................................................................................3 1. GENERAL INFORMATION ..................................................................................................................4 1.1. GENERAL DESCRIPTION OF EUT ............................................................................................4 2. APPLICABLE RF EXPOSURE LIMIT .................................................................................................5 2.1. LIMITS .........................................................................................................................................5 2.2. DETERMINATION OF EXEMPTION ...........................................................................................6 2.3. MULTIPLE RF SOURCES ARE EXEMPT ...................................................................................7 2.4. MPE CALCULATION FORMULA .................................................................................................8 3. CLASSIFICATION ................................................................................................................................8 4. ANTENNA GAIN ..................................................................................................................................8 5. CALCULATED RESULT OF MAXIMUM CONDUCTED POWER ......................................................9 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 9 Report Version A Test Report No.: FM2603WDG0470 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2603WDG0470 Original release Aug. 25, 2026 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 9 Report Version A Test Report No.: FM2603WDG0470 1. GENERAL INFORMATION 1.1. GENERAL DESCRIPTION OF EUT FCC ID 2AKE4WHP3 PRODUCT Wireless Hygrometer Probe MODEL NO. WHP3 ADDITIONAL MODEL N/A POWER SUPPLY DC 3V (1.5V*AAA*2) from battery MODULATION TECHNOLOGY DTS MODULATION TYPE BT-LE for GFSK (1Mbps) OPERATING FREQUENCY RANGE 2402MHz ~ 2480MHz ANTENNA TYPE FPC Antenna, 2.82dBi Gain I/O PORTS Refer to user’s manual CABLE SUPPLIED N/A NOTES: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's manual. 2. For the test results, the EUT had been tested with all conditions, but only the worst case was shown in test report. 3. Please refer to the EUT photo document (Reference No.: 2…

Text truncated - open the document above for the full version.

Test Report

1 ShenZhen City FeiMin Technology CO.,LTD. SPECIFICATION FOR APPROVED CUSTOMER: Huizhou XinSheng Technology Co., Ltd. PRODUCTS: FPC antenna PART NO: Spec.: FM-S1128-MHF(56mm) Data: 2026.8.28 REMARK:Please send us one(or copy)of this approval with stamp after accepting,other copies filed by the customer. ADD: Room 801, 8th Floor, Keyunda E-commerce Base, No. 4 Shenghui Road, Guxing Community, Xixiang Subdistrict, Baoan District, Shenzhen. Tel: 0755-23035723 Fax: 0755-23036702 E-mail: [email protected] HTTP:www.fmant.cn CUSTOMER ACCEPTED BY CHECKED BY APPROVED BY SUPPLIER PREPARED BY CHECKED BY APPROVED BY ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 2 catalog 1. Project Information ................................................................................................... 4 1.1. Appearance and Dimensions ........................................................................... 4 2. Electrical Characteristics ........................................................................................... 5 2.1. Test Environment Conditions .......................................................................... 5 2.2.Measurement method .......................................................................................... 5 2.2.2.Antenna VSWR ............................................................................................. 5 2.2.3.Antenna Return loss ............................................................................. 6 2.3.Antenna passive test data ..................................................................... 6 2.3.1.Test system ................................................................................................. 6 2.3.2.Antenna efficiency and gain........................................................... 7 2.3.3.Antenna Radiation Pattern ..................................................................... 7 3.Notes ............................................................................................................................. 8 4.Product packaging specification .................................................................................. 8 ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 3 Revision history version date condition A1 2026-8-28 First edition Changes: First change: Before the change: (If necessary, please add corresponding pictures, and the details of the change should be clearly described here) After the change: (If necessary, please add corresponding pictures, and the details of the change should be clearly described here) ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 4 1. Project Information 1.1. Appearance and Dimensions ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 5 2. Electrical Characteristics 2.1. Test Environment Conditions Temperature Ordinary Temperature (5 to 35°C) Humidity Ordinary Humidity (25 to 85% RH) 2.2.Measurement method 2.2.2.Antenna VSWR ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 6 2.2.3.Antenna Return loss 2.3.Antenna passive test data 2.3.1.Test system Shenzhen Feimin Technology Co., Ltd. (24-probe OTA microwave darkroom) ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 7 2.3.2.Antenna efficiency and gain Freq(MHz) Efficiency (%) Gain(dBi) 2400 52.74 1.92 2410 53.85 2.03 2420 53.84 2.82 2430 54.62 2.25 2440 55.27 2.75 2450 54.32 2.75 2460 53.68 2.43 2470 53.76 2.03 2480 51.65 1.97 2490 50.68 1.95 2500 51.12 1.52 2.3.3.Antenna Radiation Pattern XOY-plane@2440MHz YOZ-plane@2440MHz XOZ-plane@2440MHz 3D-plane @2440MHz ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 8 3.Notes ①. When installing, be careful not to be too close to the metal parts to avoid affecting the antenna performance. ②.This antenna is only suitable for this type of machine. The position of the antenna cannot be changed at will, and it is not our business' responsibility if it is used on other machines that results in poor results. ③. The data used in this acknowledgment (e.g., antenna efficiency, gain, etc.) are data obtained from laboratory tests of the acknowledgement project / antenna in Shenzhen Fei Min Technology Co., Ltd. 4.Product packaging specification Product name: FPC antenna 1、Labeling requirements The inner label is 7CM long and 4CM wide The outer label is 7CM long, about 5CM 2、Packing process Job description: 1. The product __PCS is packed in PE open pockets, and the inner label is affixed to each pouch; Put the __ small bag into the big PE sealing tape bag, except the tail number and spare parts. 2. Each box contains __ large bags of products, and the boxes are sealed with adhesive tape in the shape of "I"。 3. Paste the outer label on the upper right corner of the box, and there must be no missing or wrong filling. 3、Precautions When packing the box, please pay attention to lay the antenna flat and avoid serious shaking after sealing. If the whole box is not filled, it needs to be filled with foam to avoid transportation Circumstances that caused product defects in the process。 client's name supplier Shenzhen Feimin Technology Co., Ltd. Order number ************* Material coding ************* Specification model ****** product name ******* quantity *****PCS QC: spare parts ***PCS Notes supplier Shenzhen Feimin Technology Co., Ltd. product name ************* Material coding ************* Specifications ********** quantity ***PCS

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 41 Report Version A Test Report No.: RF2603WDG0470 TEST REPORT Applicant KANE USA INC. Address 7601 E. 88th Place Ste. 888 Indianapolis Indiana United States 46256 Manufacturer or Supplier ePlus Innovation Corp. Address 2F., No.19, Ancheng St., Xindian Dist., New Taipei City 23154, Taiwan China. Product Wireless Hygrometer Probe Brand Name UEi Test Instruments Model WHP3 Additional Model & Model Difference N/A Date of tests May 12, 2026 ~ May 15, 2026 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Bill Xie Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Aug. 25, 2026 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 41 Report Version A Test Report No.: RF2603WDG0470 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ...................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ........................................................................................ 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 7 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................................... 9 3.4 DESCRIPTION OF SUPPORT UNITS .................................................................................. 9 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 10 3.6 DUTY CYCLE OF TESET SIGNAL ....................................................................................... 11 4 TEST TYPES AND RESULTS ...................................................................................................... 12 4.1 RADIATED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 13 4.1.3 TEST PROCEDURES ..................................................................................................... 14 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 15 4.1.5 TEST SETUP ................................................................................................................... 15 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 16 4.1.7 TEST RESULTS ....................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Linda Li(General Manager)
[email protected]Fax: 503-643-6322

Technical Contact

KANE USA INC.Linda li
[email protected]

7601 E. 88th Place Ste. 888 · Indianapolis, Indiana, 46256 · United States

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz580.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. Device meets SAR Exemption for Portable use.