Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2021-3-13> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AKHB-ZB006 ZB006-X For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Yong Wang/Safety Engineer Company: Fantem Technologies (Shenzhen) Co.,Ltd Address: 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Phone: +86-18664336563 Fax: +86-755-81785053 E-Mail: [email protected]
Fantem Technologies (Shenzhen) Co.,Ltd 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-3-13 To whom it may concern: We, Fantem Technologies (Shenzhen) Co.,Ltd the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AKHB-ZB006 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Yong Wang/Safety Engineer Company: Fantem Technologies (Shenzhen) Co.,Ltd Address: 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Phone: +86-18664336563 Fax: +86-755-81785053 E-Mail: [email protected]
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Fig.7
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 _____________________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 LABEL AND LOCATION (Size: L4.0cm x 3.0cm) Material: Tagboard Glue: adhesive sticker Font color: White Label color: Black Label Location In Wall Dimmer(ZB) Model No.: ZB006-X FCC ID: 2AKHB-ZB006
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 1. TERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Fig. 5
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Page 1 of 4 FCC RF Exposure Evaluation 1. Product Information FCC ID: 2AKHB-ZB006 Product name In Wall Dimmer(ZB) Test Model ZB006-X Additional Model / Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power supply Input: AC 100-240V, 50/60Hz, 0.5W Output: AC 100-240V, 1.2A Max Channel Number 16 channels Modulation Type O-QPSK Antenna Type External Antenna Antenna Gain 0dBi (maximum) Hardware version AB Software version V1.01 Operation frequency 2405MHz-2480MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Page 2 of 4 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Page 3 of 4 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information Artemis Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna External Antenna 2405MHz-2480MHz 0dBi 2.4G Antenna 6. Conducted Power [Zigbee] Mode Channel Frequency (MHz) Conducted Output Power (dBm) GFSK 0 2405 4.702 7 2440 4.624 15 2480 5.072 7. Manufacturing Tolerance [Zigbee] 2.4G (Peak) Channel Channel 0 Channel 7 Channel 15 Target (dBm) 5.0 5.0 5.0 Tolerance ±(dB) 1.0 1.0 1.0 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Page 4 of 4 8. Measurement Results 8.1 Standalone MPE As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained. [Antenna ] Band/Mode RF output power Antenna Gain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBm mW GFSK 6.0 3.9811 0 0.0008 1.0000 Remark: 1. Output power including tune-up tolerance; 2. MPE evaluate distance is 20cm from user manual provide by manufacturer; 9. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 1 of 14 Appendix B RF Test Data for Zigbee (Conducted Measurement) Product Name: In Wall Dimmer(ZB) Trade Mark: FANTEM Test Model: ZB006-X Environmental Conditions Temperature: 23.4C Relative Humidity: 54.5% ATM Pressure: 100.0 kPa Test Engineer: Ben Jin Supervised by: Li Huan B.1 Duty Cycle Test Mode Test Channel Ant Duty Cycle[%] Verdict Zigbee 2440 Ant1 100 PASS #im grbble1hchnnav SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 2 of 14 B.2 Maximum Conducted Peak Output Power Mode Channel Conduct Peak Power[dBm] Limit [dBm] Verdict Zigbee LCH 4.702 30 PASS Zigbee MCH 4.624 30 PASS Zigbee HCH 5.072 30 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 3 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 4 of 14 B.3 Maximum Power Spectral Density Mode Channel PSD [dBm/3KHz] Limit [dBm/3KHz] Verdict Zigbee LCH -11.844 8 PASS Zigbee MCH -11.557 8 PASS Zigbee HCH -11.010 8 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 5 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 6 of 14 B.4 6dB Bandwidth Mode Channel 6dB Bandwidth [MHz] Limit [MHz] Verdict Zigbee LCH 1.647 ≥0.5 PASS Zigbee MCH 1.713 ≥0.5 PASS Zigbee HCH 1.776 ≥0.5 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 7 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 8 of 14 B.5 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdict Zigbee LCH 0.846 -37.238 -19.15 PASS Zigbee MCH 0.647 -37.335 -19.35 PASS Zigbee HCH 1.101 -37.368 -18.90 PASS Zigbee_LCH_Graphs Pref/Zigbee/LCH Puw/Zigbee/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 9 of 14 Zigbee_MCH_Graphs Pref/Zigbee/MCH Puw/Zigbee/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 10 of 14 Zigbee_HCH_Graphs Pref/Zigbee/HCH Puw/Zigbee/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 11 of 14 B.6 Band-edge for RF Conducted Emissions Mode Channel Carrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm] Verdict Zigbee LCH 0.563 -49.443 -19.27 PASS Zigbee HCH 1.379 -45.419 -18.62 PASS Test Graphs LCH HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 12 of 14 B.7 Restrict-band band-edge measurements Test Mode Test Chann el Ant Freq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBuV/ m] Verdi ct Zigbee 2405 Ant1 2310.0 -42.96 2.0 0 54.30 PEAK 74 PASS Ant1 2310.0 -53.73 2.0 0 43.53 AV 54 PASS Ant1 2390.0 -43.63 2.0 0 53.63 PEAK 74 PASS Ant1 2390.0 -53.28 2.0 0 43.98 AV 54 PASS 2480 Ant1 2483.5 -34.87 2.0 0 62.39 PEAK 74 PASS Ant1 2483.5 -45.82 2.0 0 51.44 AV 54 PASS Ant1 2500.0 -43.68 2.0 0 53.58 PEAK 74 PASS Ant1 2500.0 -52.89 2.0 0 44.37 AV 54 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 13 of 14 Restrict-band band-edge measurements_Zigbee_2405_Ant1_PEAK Restrict-band band-edge measurements_Zigbee_2405_Ant1_AV SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA Page 14 of 14 Restrict-band band-edge measurements_Zigbee_2480_Ant1_PEAK Restrict-band band-edge measurements_Zigbee_2480_Ant1_AV
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 34 FCC TEST REPORT For Fantem Technologies (Shenzhen) Co.,Ltd In Wall Dimmer(ZB) Test Model: ZB006-X Prepared for : Fantem Technologies (Shenzhen) Co.,Ltd Address : 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : December 28, 2020 Number of tested samples : 2 Sample No. : 201221009A-1, 201221009A-2 Serial number : Prototype Date of Test : December 28, 2020 ~ January 15, 2021 Date of Report : January 15, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 34 FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCS201221009AEA Date of Issue ................................... : January 15, 2021 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Fantem Technologies (Shenzhen) Co.,Ltd Address ........................................... : 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Test Specification Standard.......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : In Wall Dimmer(ZB) Trade Mark .......................................................................................................................................... : FANTEM Model/ Type reference ........................................................................................................................ : ZB006-X Ratings ................................................................................................................................................ : Input: AC 100-240V, 50/60Hz, 0.5W Output: AC 100-240V, 1.2A Max Result ........................................... : Positive Compiled by: Supervised by: Approved by: Cherry Chen/ Administrators Jin Wang / Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 34 FCC -- TEST REPORT Type / Model........................... : ZB006-X EUT......................................... : In Wall Dimmer(ZB) Applicant............................... : Fantem Technologies (Shenzhen) Co.,Ltd Address.................................. : 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Fantem Technologies (Shenzhen) Co.,Ltd Address................................... : 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Telephone............................... : / Fax.......................................... : / Factory................................... : Fantem Technologies (Shenzhen) Co.,Ltd Address................................... : 5th Floor,Yingtang Building,South 5th Road, HI-tech Park,Nanshan District,Shenzhen,Guangdong, China Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS201221009AEA January 15, 2021 Date of issue SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 34 Revision History Revision Issue Date Revisions Revised By 000 January 15, 2021 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 Report No.: LCS201221009AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 34 TABLE OF CONTENTS 1. GENERAL INFORMATION ......................................................................................................................…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 _______________________________________________________________________________________________ 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AKHB-ZB006 _______________________________________________________________________________________________ 1.1. Photo of Conducted Emissions Measurement Fig. 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.20 mW |

Multisensor(ZB)
Equipment Class
DTS - Digital Transmission System