Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SERVICE MANUAL To learn more: visit www.proxess.com or call 303-317-6656 Introducing EZ Connect 2 CX-Series Service Manual TABLE OF CONTENTS INTRODUCTION 3 Certifications and standards 3-A Technical support 3-B FUNCTIONS 4 Construction Function 4-A Programmable Functions 5-B Cylindrical Functions Chart 5-C LOCK PARTS 6 Exploded view of parts 6-A Parts list 6-B Trim parts 7-C MAINTENANCE 9 Maintenance tools 9-A Replacing levers 9-B DOOR PREPARATION AND INSTALLATION 10 Cylindrical Installation Jigs 10-A Through-Bolt Drill Jig 10-B Deadbolt Door Configuration 10-C TROUBLESHOOTING 11 Troubleshooting hardware 11-A INSTALLATION MANUAL 12 CX-Series Installation Instructions 12 ADDITIONAL RESOURCES 18 Service Equipment 18-A Software Solutions for Lockset Programming 19-B FCC Statement 20 UL Statement 20 This Service Manual contains details for the Proxess CX- Series Lockset sold for 2021 (CX-B and CX-NB). For details about the CX-Series locksets sold prior to 2021 (CX-ST) please contact a Proxess representative or email [email protected]. 3 CX-Series Service Manual COPYRIGHT Copyright ©2018 Proxess, LLC. All rights reserved. Printed in the United States of America. Information in this document is subject to change without notice and does not represent a commitment on the part of Proxess, LLC. The software described in this document are furnished under a license agreement or nondisclosure agreement. This publication is intended to be an accurate description and set of instructions pertaining to its subject matter. However, as with any publication of this complexity, errors or omissions are possible. Please call Proxess corporate offices at (303) 317-6656 if you see any errors or have any questions. No part of this manual and/or databases may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose, without the express written permission of Proxess, LLC. This document is distributed as is, without warranty of any kind, either express or implied, respecting the contents of this book, including but not limited to implied warranties for the publication’s quality, performance, merchantability, or fitness for any particular purpose. Neither Proxess, LLC nor its dealers or distributors shall be liable to the user or any other person or entity with respect to any liability, loss, or damage caused or alleged to be caused directly or indirectly by this publication. INTRODUCTION The Proxess CX-Series Service Manual contains important information to assist you in maintaining your Proxess Cylindrical Lockset. CERTIFICATIONS AND STANDARDS (CX 2.5 Currently, 3.0 Pending) ANSI/BHMA A156.25 (Indoor/Outdoor) ANSI/BHMA A156.2 Grade 1 UL 294 ULC S319 PDR UL10C Positive Pressure Rated UL10B Neutral Pressure Rated FCC Part 15 ADA Compliant RoHS Industry Canada (IC) ETSI EN 300 330-1 ETSI EN 301 489-1 ETSI EN 301 489-3 CENELEC EN 61000-6-3 IEC61000-4-2 ESD Immunity CENELEC EN 50130-4 TECHNICAL SUPPORT The first source for technical answers is this CX Series Service Manual. All documentation and training materials are also available on our website: www.proxess.com. If you are not able to find an answer in these resources, contact your local Proxess Representative. If you do not know your local Proxess Representative, contact the Customer Service Department at Proxess (303)-317-6656. 3-A 3-B 3-B 4 CX-Series Service Manual FUNCTIONS CONSTRUCTION FUNCTION All locks are supplied in Construction Function as a default and functions are meant to be reprogrammed at customer site prior to installation. There is one SKU (standard button) for all functions creating an inventory advantage over standard mechanical locks. CC – Construction Function: Factory default setting. In Construction Function, factory programmed construction credentials granted access at the lockset to allow for testing prior to site programming. Upon first programming of the lock, the lock will switch to Program Lock Function. A system ID will be set by the site system allowing all credentials assigned to the site system access until the lock is reprogrammed. Inside lever is always unlocked for single action egress. Shading indicates that the lever is locked. 4-A All lock functions (Entrance, Storeroom, Lockdown, etc) are easily programmed electronically. Inside Outside View looking down at the top of the door 5 CX-Series Service Manual PROGRAMMABLE FUNCTIONS Unlike standard locks, Proxess has just one SKU allowing any lock to be supplied and programmed into numerous lock “functions” similar to standard locking functions shown in the chart below. Name Similar ANSI # Mech Proxess Electronic Equivalent Function Entrance F109 Enable toggle schedule and double present credential to outside reader to lock/unlock door Storeroom F86 A valid credential should provide momentary unlocking and allow entry by that user, with the latch relocking in an administrator defined time (usually 5-8 seconds).. Office F82 A valid credential should provide momentary unlocking and allow entry by that user, with the latch relocking in an administrator defined time (usually 5-8 seconds).. Classroom no Lockdown F84 Enable toggle schedule and double present credential to outside reader to lock/unlock door. Classroom w/Lockdown (Intruder) F110 Enable toggle schedule and double present credential to outside reader to lock/unlock door. Lockdown performed by gesture. Classroom w/Holdback F85 Enable toggle schedule and double present credential to outside reader to lock/unlock door. (electronic equivalent to F84, because unlocked door allows free entry). There is no Holdback. Canadian Function Select toggle mode in the ACS and depress internal button to toggle the lockset from lock/unlock. Patio F77 Select toggle mode in the ACS and depress internal button to toggle the lockset from lock/unlock. Secured Privacy Select toggle mode in the ACS and depress internal button to t…
Text truncated - open the document above for the full version.
To learn more: visit www.proxess.com or call 303-317-6656 SERVICE MANUAL Introducing EZ Connect 2 Mortise Service Manual TABLE OF CONTENTS INTRODUCTION 3 DOCUMENTATION PACKAGE 3 CERTIFICATIONS AND STANDARDS 3 TECHNICAL SUPPORT 4 FUNCTIONS 4 LOCK FUNCTIONS LETTER CHART 4 LOCK PARTS 5 PARTS BLOWUP 5 PARTS NUMBER CHART 5 CASE AND STRIKE DIMENSIONS 6 CYLINDER/KEYING 6 TRIM PARTS 7 MAINTENANCE 7 TOOLS FOR MAINTENANCE 7 TROUBLESHOOTING HARDWARE 8 INSTALLATION MANUAL 9 MORTISE INSTALLATION DOOR PREP 10 MORTISE INTALLATION INSTRUCTIONS 12 MORTISE INSTALLATION TEMPLATE 21 ADDITIONAL RESOURCES 22 SERVICE EQUIPMENT 22 SOFTWARE SOLUTIONS 23 FCC Staatement 24 3 Mortise Service Manual COPYRIGHT Copyright ©2018 Proxess, LLC. All rights reserved. Printed in the United States of America. Information in this document is subject to change without notice and does not represent a commitment on the part of Proxess, LLC. The software described in this document are furnished under a license agreement or nondisclosure agreement. This publication is intended to be an accurate description and set of instructions pertaining to its subject matter. However, as with any publication of this complexity, errors or omissions are possible. Please call Proxess corporate offices at (303) 317-6656 if you see any errors or have any questions. No part of this manual and/or databases may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose, without the express written permission of Proxess, LLC. This document is distributed as is, without warranty of any kind, either express or implied, respecting the contents of this book, including but not limited to implied warranties for the publication’s quality, performance, merchantability, or fitness for any particular purpose. Neither Proxess, LLC nor its dealers or distributors shall be liable to the user or any other person or entity with respect to any liability, loss, or damage caused or alleged to be caused directly or indirectly by this publication. INTRODUCTION The Proxess MX-Series Service Manual contains important information to assist you in maintaining your Proxess Mortise Lockset. CERTIFICATIONS AND STANDARD ANSI/BHMA A156.25 (Indoor/Outdoor) ANSI/BHMA A156.2 Grade 1 ULC S319 PDR ULC Canada UL10C Fire-Rated UL10B Neutral Pressure Rated FCC Part 15 ADA Compliant RoHS Industry Canada (IC) TECHNICAL SUPPORT The first source for technical answers is this MX Series Service Manual. All documentation and training materials are also available on our website: www.proxess.com. If you are not able to find an answer in this manual, contact your local Proxess Representative. If you do not know your local Proxess Representative, contact the Customer Service Department at Proxess (303)-317-6656. 4 Mortise Service Manual Name Similar ANSI # Mech DescriptionProxess Electronic Equivalent Function EntranceF109 Turn/Push button locking. Pushing and turning button on inside locks outside knob/lever requiring use of a key until button is manually unlocked. Push button locking. Pushing button locks the outside knob/lever until unlocked by key or by turning the inside lever/knob. Inside knob/lever always free. Enable toggle schedule and double present credential to outside reader to lock/unlock door StoreroomF86 Outside knob/lever always rigid. Key required for entry. Inside always free. A valid credential should provide momentary unlocking and allow entry by that user, with the latch relocking in an administrator defined time (usually 5-8 seconds).. OfficeF82 Push button locking. Button on inside locks outside knob/lever until unlocked by key, or by rotating the inside knob/lever. Inside knob/lever always free. Deadlocking latch bolt. A valid credential should provide momentary unlocking and allow entry by that user, with the latch relocking in an administrator defined time (usually 5-8 seconds).. Classroom no LockdownF84 Classroom/Office or Utility Room. Key locks/unlock outer knob or lever. Inside always free. Enable toggle schedule and double present credential to outside reader to lock/unlock door. Classroom w/Lockdown (Intruder) F110 Deadlocking latch bolt operated by lever from either side. Key either inside or outside locks or unlocks outside lever. Inside lever always operates latch bolt. Enable toggle schedule and double present credential to outside reader to lock/unlock door. Lockdown performed by gesture. Classroom w/Lockdown (Intruder) F110 Deadlocking latch bolt operated by lever from either side. Key either inside or outside locks or unlocks outside lever. Inside lever always operates latch bolt. Enable toggle schedule and double present credential to outside reader to lock/unlock door. Lockdown performed by gesture. Classroom w/HoldbackF85 Deadlocking latch bolt by knobs. Outside knob is locked by key in outside knob. Inside knob is always free. Latch may be held back by depressing latch and rotating key. Enable toggle schedule and double present credential to outside reader to lock/unlock door. (electronic equivalent to F84, because unlocked door allows free entry) Canadian Function Deadlocking latch bolt by levers except when outside lever is locked by push button. Outside lever locked by pressing push button only. Future Use Function PatioF77 Outside knob/lever locked by push button on inside knob/lever. Rotating inside knob/lever or closing door releases/unlocks button. Emergency release in outside knob/lever. Future Use Function Secured Privacy Outside knob/lever locked by pushbutton on inside knob/lever. Rotating inside knob/lever or closing door releases/unlocks button. Emergency push button in outside knob unlocks door. Future Use Function Hotel Guest RoomF93 Outside knob fixed. Entrance by key only. Push button in inside knob activates visual occupancy indicator, allowing only emergency master key to operate. Rotation of inside…
Text truncated - open the document above for the full version.
FCC ID: 2AKUZPXH01 IC ID: 22335-PXH01 HVINs: PXH01-CX03-B, PXH01-CX03-DC, PXH01-MX02-B, PXH01-MX02-DC 8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656
8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656 FCC ID: 2AKUZPXH01 Contains FCC ID: SH6MDBT50Q IC: 22335-PXH01 Contains IC: 8017A-MDBT50Q Models: PXH01-CX03-DC Power: DC 12V In 8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656 FCC ID: 2AKUZPXH01 Contains FCC ID: SH6MDBT50Q IC: 22335-PXH01 Contains IC: 8017A-MDBT50Q Models: PXH01-CX03-B Battery: 4 x AA 1.5V Alkaline PMN: MX-Series Mortise Lockset 8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656 PMN: MX-Series Mortise Lockset 8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656
FCC ID: 2AKUZPXH01 IC ID: 22335-PXH01 HVINs: PXH01-CX03-B, PXH01-CX03-DC, PXH01-MX02-B, PXH01-MX02-DC 8100 SOUTHPARK WAY, SUITE A4, LITTLETON, COLORADO, 80120 WWW.PROXESS.COM / (303)- 317- 6656
Proxess LLC RF Exposure Exhibit SCOPE OF WORK EMC TESTING – Proxess CX-Series Cylindrical Lockset, Model Tested: CX Cylindrical REPORT NUMBER 104273165MPK-002 ISSUE DATE August 12, 2020 REVISED DATE N/A PAGES 10 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 MPK © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the CX Cylindrical Page 2 of 10 RF Exposure Exhibit (mobile devices) Report Number: 104273165MPK-002 Project Number: G104273165 Report Issue Date: August 12, 2020 Product Designation: Model Tested: Proxess CX-Series Cylindrical Lockset CX Cylindrical HVIN: PXH01-CX03-DC HVIN: PXHO1-CX03-B FCC ID: 2AKUZPXH01 IC: 22335-PXH01 to 47CFR 2.1091 RSS-102 Issue 5 for Proxess LLC Tested by: Client: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Proxess LLC 8100 Southpark Way - Suite A4 Littleton, CO 80120 USA Report prepared by: Report reviewed by: Todd Moy/ Project Engineer Krishna Vemuri / EMC Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. REPORT NUMBER: 104273165MPK-002 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the CX Cylindrical Page 3 of 10 Report No. 104273165MPK-002 Equipment Under Test: Proxess CX-Series Cylindrical Lockset Trade Name: Proxess LLC Model(s) Tested: CX Cylindrical Applicant: Proxess LLC Contact: Jeff Cahill Address: Proxess LLC 8100 Southpark Way - Suite A4 San Jose, CA 95131 Country: USA Tel. Number: (303) 520-6763 Email: [email protected] Applicable Regulation: 47CFR 2.1091 RSS-102 Issue 5 REPORT NUMBER: 104273165MPK-002 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the CX Cylindrical Page 4 of 10 TABLE OF CONTENTS Proxess LLC ..................................................................................................................................................... 1 1.0 RF Exposure Summary ............................................................................................................................ 5 2.0 RF Exposure Limits .................................................................................................................................. 5 3.0 Test Results (Mobile Configuration) ......................................................................................................... 7 Appendix A: Power Density Calculation ............................................................................................................ 9 4.0 Document History ................................................................................................................................. 10 REPORT NUMBER: 104273165MPK-002 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the CX Cylindrical Page 5 of 10 1.0 RF Exposure Summary Test Reference FCC Reference Industry Canada Result Radio frequency Radiation Exposure Evaluation 47 CFR§2.1091 RSS-102 Issue 5 Complies 2.0 RF Exposure Limits In this document, we evaluate the RF Exposure to human body due the intentional transmission from the transmitter (EUT). The limits for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 and RSS-102 are followed. 2.1 FCC Limits According to FCC 1.1310 table 1: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) (A)Limits For Occupational / Control Exposures 0.3 – 3.0 614 1.63 *100 6 3.0 – 30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300 - 1500 ... ... F/300 6 1500 - 100,000 ... ... 5 6 (B )Limits For General Population / Uncontrolled Exposure 0.3 – 1.34 614 1.63 *100 30 1.34 – 30 824/f 2.19/f *180/f 2 30 30 – 300 27.5 0.073 0.2 30 300 - 1500 ... ... F/1500 30 1500 - 100,000 ... ... 1.0 30 F = Frequency in MHz * = plane wave equivalent density REPORT NUMBER: 104273165MPK-002 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the CX Cylindrical Page 6 of 10 2.2 Industry Canada Limits According to RSS-102, Industry Canada has adopted the SAR and RF field strength limits established in Health Canada’s RF exposure guideline, Safety Code 6. Table 4: RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment) Frequency Range Electric Field Magnetic Field Power Density Reference Period (MHz) (V/m rms) (A/m rms) (W/m 2 ) (minutes) 0.003-10 83 90 - Instantaneous* 0.1-10 - 0.73/ ƒ - 6** 1.1-10 87/ ƒ 0.5 - - 6** 10-20 27.46 0.0728 -2 6 20-48 58.07/ ƒ 0.25 0.1540/ ƒ 0.25 8.944/ ƒ0.5 6 48-300 22.06 0.05852 1.291 6 300-6000 3.142 ƒ 0.3417 0.008335 ƒ 0.3417 0.02619 ƒ 0.6834 6 6000-15000 61.4 0.163 10 6 15000-150000 61.4 0.163 10 616000/ ƒ 1.2 150000-300000 0.158 ƒ 0.5 4.21 x 10-4 ƒ 0.5 6.67 x 10 -5 ƒ 616000/ƒ 1.2 Note: ƒ is frequency in MHz. * Based on nerv…
Text truncated - open the document above for the full version.
Proxess LLC RF Exposure Exhibit SCOPE OF WORK EMC TESTING – Proxess MX-Series Mortise Lockset, Model Tested: MX Mortise REPORT NUMBER 104273165MPK-003 ISSUE DATE August 12, 2020 REVISED DATE N/A PAGES 10 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 MPK © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the MX Mortise Page 2 of 10 RF Exposure Exhibit (mobile devices) Report Number: 104273165MPK-003 Project Number: G104273165 Report Issue Date: August 12, 2020 Product Designation: Model Tested: Proxess MX-Series Mortise Lockset MX Mortise HVIN: PXH01-MX02-DC HVIN: PXH01-MX02-B FCC ID: 2AKUZPXH01 IC: 22335-PXH01 to 47CFR 2.1091 RSS-102 Issue 5 for Proxess LLC Tested by: Client: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Proxess LLC 8100 Southpark Way - Suite A4 Littleton, CO 80120 USA Report prepared by: Report reviewed by: Todd Moy / EMC Project Engineer Krishna Vemuri / EMC Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. REPORT NUMBER: 104273165MPK-003 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the MX Mortise Page 3 of 10 Report No. 104273165MPK-003 Equipment Under Test: Proxess MX-Series Mortise Lockset Trade Name: Proxess LLC Model(s) Tested: MX Mortise Applicant: Proxess LLC Contact: Jeff Cahill Address: Proxess LLC 8100 Southpark Way - Suite A4 San Jose, CA 95131 Country: USA Tel. Number: (303) 520-6763 Email: [email protected] Applicable Regulation: 47CFR 2.1091 RSS-102 Issue 5 REPORT NUMBER: 104273165MPK-003 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the MX Mortise Page 4 of 10 TABLE OF CONTENTS Proxess LLC ..................................................................................................................................................... 1 1.0 RF Exposure Summary ............................................................................................................................ 5 2.0 RF Exposure Limits .................................................................................................................................. 5 3.0 Test Results (Mobile Configuration) ......................................................................................................... 7 Appendix A: Power Density Calculation ............................................................................................................ 9 4.0 Document History ................................................................................................................................. 10 REPORT NUMBER: 104273165MPK-003 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the MX Mortise Page 5 of 10 1.0 RF Exposure Summary Test Reference FCC Reference Industry Canada Result Radio frequency Radiation Exposure Evaluation 47 CFR§2.1091 RSS-102 Issue 5 Complies 2.0 RF Exposure Limits In this document, we evaluate the RF Exposure to human body due the intentional transmission from the transmitter (EUT). The limits for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 and RSS-102 are followed. 2.1 FCC Limits According to FCC 1.1310 table 1: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) (A)Limits For Occupational / Control Exposures 0.3 – 3.0 614 1.63 *100 6 3.0 – 30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300 - 1500 ... ... F/300 6 1500 - 100,000 ... ... 5 6 (B )Limits For General Population / Uncontrolled Exposure 0.3 – 1.34 614 1.63 *100 30 1.34 – 30 824/f 2.19/f *180/f 2 30 30 – 300 27.5 0.073 0.2 30 300 - 1500 ... ... F/1500 30 1500 - 100,000 ... ... 1.0 30 F = Frequency in MHz * = plane wave equivalent density REPORT NUMBER: 104273165MPK-003 Issued: August 12, 2020 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Proxess LLC on the MX Mortise Page 6 of 10 2.2 Industry Canada Limits According to RSS-102, Industry Canada has adopted the SAR and RF field strength limits established in Health Canada’s RF exposure guideline, Safety Code 6. Table 4: RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment) Frequency Range Electric Field Magnetic Field Power Density Reference Period (MHz) (V/m rms) (A/m rms) (W/m 2 ) (minutes) 0.003-10 83 90 - Instantaneous* 0.1-10 - 0.73/ ƒ - 6** 1.1-10 87/ ƒ 0.5 - - 6** 10-20 27.46 0.0728 -2 6 20-48 58.07/ ƒ 0.25 0.1540/ ƒ 0.25 8.944/ ƒ0.5 6 48-300 22.06 0.05852 1.291 6 300-6000 3.142 ƒ 0.3417 0.008335 ƒ 0.3417 0.02619 ƒ 0.6834 6 6000-15000 61.4 0.163 10 6 15000-150000 61.4 0.163 10 616000/ ƒ 1.2 150000-300000 0.158 ƒ 0.5 4.21 x 10-4 ƒ 0.5 6.67 x 10 -5 ƒ 616000/ƒ 1.2 Note: ƒ is frequency in MHz. * Based on nerve stimulation (NS). ** Based on specifi…
Text truncated - open the document above for the full version.
EMC Proxess LLC on CX Cylindrical File: 104273165MPK-001A Page 1 of 48 TEST REPORT Report Number: 104273165MPK-001A Project Number: G104273165 August 11, 2020 Testing performed on the Proxess CX-Series Cylindrical Lockset Model Number: CX Cylindrical HVIN: PXH01-CX03-DC HVIN: PXHO1-CX03-B FCC ID: 2AKUZPXH01 IC: 22335-PXH01 to FCC Part 15 Subpart C (15.225) Industry Canada RSS-210 Issue 10 FCC Part 15, Subpart B Industry Canada ICES-003 For Proxess LLC Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Proxess LLC 8100 Southpark Way - Suite A4 Littleton, CO 80120 USA Prepared by: Date: August 11, 2020 Todd Moy Reviewed by: Date: August 11, 2020 Krishna Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of th is report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in w riting by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Proxess LLC on CX Cylindrical File: 104273165MPK-001A Page 2 of 48 Report No. 104273165MPK-001A Equipment Under Test: Proxess CX-Series Cylindrical Lockset Trade Name: Proxess LLC Model Number: CX Cylindrical Serial Number: 104273165-001 Applicant: Proxess LLC Contact: Jeff Cahill Address: 8100 Southpark Way - Suite A4 Littleton, CO 80120 Country USA Email [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.225) Industry Canada RSS-210 Issue 10 FCC Part 15, Subpart B Industry Canada ICES-003 Issue 6 Test Site Location: ITS – Site 1 1365 Adams Drive Menlo Park, CA 94025 Date of Test: April 27-August 3, 2020 We attest to the accuracy of this report: Todd Moy Project Engineer Krishna K Vemuri EMC Manager EMC Proxess LLC on CX Cylindrical File: 104273165MPK-001A Page 3 of 48 TABLE OF C ONTENTS 1.0 Summary of Tests .......................................................................................................................... 5 2.0 General Description ....................................................................................................................... 6 2.1 Product Description ............................................................................................................ 6 2.2 Related Submittal(s) Grants ................................................................................................ 7 2.3 Test Methodology ............................................................................................................... 7 2.4 Test Facility ........................................................................................................................ 7 2.5 Measurement Uncertainty ................................................................................................... 7 3.0 System Test Configuration ............................................................................................................ 8 3.1 Block Diagram of Test Setup .............................................................................................. 8 3.2 Justification ......................................................................................................................... 9 3.3 Software Exercise Program................................................................................................. 9 3.4 Mode of Operation during test ............................................................................................ 9 3.5 Modifications required for Compliance .............................................................................. 9 3.6 Additions, deviations and exclusions from standards ......................................................... 9 4.0 Measurement Results................................................................................................................... 10 4.1 Field Strength of Fundamental and Radiated Emissions Outside the band ...................... 10 4.1.1 Requirements ....................................................................................................... 10 4.1.2 Procedure ............................................................................................................. 11 …
Text truncated - open the document above for the full version.
8100 Soutpark Way · Littleton, Colorado · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |