FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Ugoos Technology Co., Ltd/
  3. 2AL8Y-X4Q

2AL8Y-X4QAndroid TV Box

Shenzhen Ugoos Technology Co., Ltd
Android TV Box - FCC ID 2AL8Y-X4Q - Shenzhen Ugoos Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Dec 17, 2022
Application Purpose
Original Equipment
Date of Application
Dec 17, 2022
Equipment Note
Android TV Box
Frequency Range
5745.00000000 - 5825.00000000
Company
Shenzhen Ugoos Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Android TV Box Note:Indoor use only Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Cover Letter(s)

FCC Software Configuration Control Declaration Rev1.1 Shenzhen Ugoos Technology Co., Ltd FCC Software Configuration Control Declaration Date: Dec. 13, 2022 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Android TV Box/X4Q Pro, X4Q Cube, X4Q Plus, X4Q Max Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” W e declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Date: 2022-12-13 Name: Liu Kaohao Title: manager Signature of applicant

Cover Letter(s)

Shenzhen Ugoos Technology Co., Ltd Agent Authorization Company: Shenzhen Ugoos Technology Co., Ltd Address: Room 6A, 6th Floor, Building A, Bao'an Square, Sun'gang Road, Luohu District, Shenzhen 518020, China Product Name: Android TV Box Model Number(s): X4Q Pro, X4Q Cube, X4Q Plus, X4Q Max Product Description: Android TV Box We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: Dec. 13, 2022 Signature: Name: Liu kaohao Title: manager Company: Shenzhen Ugoos Technology Co., Ltd

Cover Letter(s)

Shenzhen Ugoos Technology Co., Ltd Date: Dec. 13, 2022 Offic e of Engineering Technology Federal Communications Commission 743 5 Oakland Mill s Road Columbia, MD 21046 US A Subject; Request for Confidentiality FCC ID: 2AL8Y-X4Q To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705 . OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Liu Kaohao Title: manager Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure FCC Software Security Requirements for UNII devices

Cover Letter(s)

Shenzhen Ugoos Technology Co., Ltd Model Confirmation Letter We, Shenzhen Ugoos Technology Co., Ltd certify the product: Android TV Box, models: X4Q Pro, X4Q Cube, X4Q Plus, X4Q Max All models are consistent in design, circuit layout, wiring and bom, but the internal running software will be different due to the needs of different customers, but these differences will not affect any electrical performance and RF parameters, so the test model is: X4Q Pro Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q Date: Dec. 13, 2022 Signature: Name: Liu kaohao Company: Shenzhen Ugoos Technology Co., Ltd

External Photos

Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q

ID Label/Location Info

Label place Size: 30*20mm Android TV Box Model: PA-110 Input: DC5.0V 2.5A FCC ID: 2AL8Y-X4Q Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q

Internal Photos

Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q BT ANT/WIFI ANT2 WIFI ANT1

RF Exposure Info

FCC ID: 2AL8Y-X4Q Applicable standard FCC KDB447498 D01 General RF Exposure Guidance v06: Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. RF Exposure Evaluation According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. Limits According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b) F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Result of RF Exposure Evaluation BT ANT1: 1.26dBi; 2.4G- ANT1:3.39dBi; ANT2:1.26dBi; MIMO:5.4dBi 5G-WIFI ANT1:3.96dBi; ANT2:2.78dBi; MIMO: 6.04dBi Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.0 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Measurement Data The Max Conducted Peak Output Power data refer to report Report No.: ZKT-221125L8872-01 & ZKT-221125L8872-02 & ZKT-221125L8872-03 & ZKT-221125L8872-04 BT/BLE-worst mode and channel: Test channel Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power Calculated value (dBm) (mW) 8-DPSK--2480MHz 6.99 7±1 8 6.310 0.0017 (BLE)GFSK--2480MHz 2.86 3±1 4 2.512 0.0007 Limit: 1.0 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+ BLE 0.0017+0.0007 0.0024 1.0 conclusion : 0.0024<1.0, So there is no sar requirement 2.4GWIFI worst mode and channel: Test channel Antenna Output Power (dBm) Maximum tune-up Power (dbm) Maximum tune-up Power (dbm) ANT1 ANT2 ANT1 ANT2 802.11b –2412MHz 15.73 15.83 16±1 16±1 20.01 802.11b –2437MHz 14.51 15.08 16±1 16±1 20.01 802.11b –2462MHz 15.18 15.19 16±1 16±1 20.01 Test worst case Maximum tune-up Power (dbm) Maximum tune-up Power (mW) Calculated value (mW/cm2) Limit (mW/cm2) 20.01 100.24 0.069 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-221125L8872-03 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 100.24*3.467)/(4*3.1415*20*20)=0.069, G=10 gain/10 =3.467 5GWIFI- worst mode and channel: U-NII-1 Mode Test channel Antenna Output Power (dBm) Tune up tolerance(dBm) Max Tune up (dBm) ANT1 ANT2 ANT1 ANT2 802.11n-5180MHz 12.37 12.49 13±1 13±1 17.01 802.11n-5200MHz 12.90 12.94 13±1 13±1 17.01 802.11n-5240MHz 13.39 13.37 13±1 13±1 17.01 U-NII-3 Mode Test channel Antenna Output Power (dBm) Tune up tolerance(dBm) Max Tune up (dBm) ANT1 ANT2 ANT1 ANT2 802.11n-5745MHz 14.56 14.62 15±1 15±1 19.01 802.11n -5785MHz 13.79 13.93 14±1 14±1 18.01 802.11n -5825MHz 12.72 12.68 13±1 13±1 17.01 Test worst case Maximum tune-up Power(dbm) Maximum tune-up Power(mW) Calculated value (mW/cm2) Limit (mW/cm2) 19.01 79.616 0.0636 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-221125L8872-04 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 79.616*4.018)/(4*3.1415*20*20)= 0.0636 , G=10 gain/10 =4.018 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+2.4G WIFI + 5G WIFI 0.0024+0.069+0.0636 0.135 1.0 conclusion : 0.135 < 1.0, So there is no sar requirement NOTE:1. EUT is more than 20cm away from the human body. 2.The sum of the ratios(2.4GWIFI + 5G WIFI+BT) is less than the limit value of 1.0, so there is no sar requirement.

Test Report

Project No.: ZKT-221125L8872-04 Page 1 of 124 FCC TEST REPORT FCC ID:2AL8Y-X4Q Report Number. .............................. : ZKT-221125L8872-04 Date of Test ...................................... : Nov. 16, 2022 – Nov. 30, 2022 Date of issue .................................... : Nov. 30, 2022 Total number of pages ..................... : 124 Test Result ....................................... : PASS Testing Laboratory. ........................ : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : Shenzhen Ugoos Technology Co., Ltd Address .......................................... : Room 6A, 6th Floor, Building A, Bao'an Square, Sun'gang Road, Luohu District, Shenzhen 518020, China Manufacturer's name ................... : Shenzhen Ugoos Technology Co., Ltd Address .......................................... : Room 6A, 6th Floor, Building A, Bao'an Square, Sun'gang Road, Luohu District, Shenzhen 518020, China Test specification: Standard .......................................... : FCC CFR Title 47 Part 15 Subpart E Section 15.407 ANSI C63.10:2013 Test procedure ................................. : KDB 789033 D02 V01r02 Non-standard test method ............. : N/A Test Report Form No. .................... : TRF-EL-110_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF .................................... : Dated: 2020-01-06 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : Android TV Box Trademark ...................................... : UGOOS Model/Type reference ...................... : X4Q Pro, X4Q Cube, X4Q Plus, X4Q Max Ratings ............................................. : DC5.0V 2.5A from adapter Project No.: ZKT-221125L8872-04 Page 2 of 124 Testing procedure and testing location: Testing Laboratory ................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Alen He Tested by (name + signature) .................... : Joe Liu Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-221125L8872-04 Page 3 of 124 Table of Contents Page 1. VERSION 5 2. SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3. GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 10 3.5EQUIPMENTS LIST FOR ALL TEST ITEMS 11 4. EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 12 4.1.2 TEST PROCEDURE 12 4.1.3 DEVIATION FROM TEST STANDARD 12 4.1.4 TEST SETUP 13 4.1.5 EUT OPERATING CONDITIONS 13 4.1.6 TEST RESULT 14 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 TEST PROCEDURE 17 4.2.3 DEVIATION FROM TEST STANDARD 17 4.2.4 TEST SETUP 18 4.2.5 EUT OPERATING CONDITIONS 19 4.2.6 TEST RESULTS 20 5.POWER SPECTRAL DENSITY TEST 49 5.1 APPLIED PROCEDURES / LIMIT 49 5.2 TEST PROCEDURE 49 5.3 DEVIATION FROM STANDARD 49 5.4 TEST SETUP 49 5.5 EUT OPERATION CONDITIONS 50 5.6 TEST RESULT 50 6. -26 DB & 6DBM EMISSION BANDWIDTH 51 6.1 APPLIED PROCEDURES / LIMIT 51 6.2 TEST PROCEDURE 51 6.3 DEVIATION FROM STANDARD 51 6.4 TEST SETUP 51 6.5 EUT OPERATION CONDITIONS 51 Project No.: ZKT-221125L8872-04 Page 4 of 124 6.6 TEST RESULT 51 7. OUTPUT POWER TEST 52 7.1 APPLIED PROCEDURES/LIMIT 52 7.2 DEVIATION FROM STANDARD 52 7.3 TEST SETUP 52 7.4 EUT OPERATION CONDITIONS 52 8. OUT OF BAND EDGE EMISSION 53 8.1 TEST PROCEDURE 53 8.2 DEVIATION FROM STANDARD 53 8.3 TEST SETUP 53 8.4 EUT OPERATION CONDITIONS 53 8.5 TEST RESULTS 53 9. FREQUENCY STABILITY MEASUREMENT 54 9.4 TEST RESULT 54 10.ANTENNA REQUIREMENT 61 11.APPENDIX1---5.2GWIFI 62 12.APPENDIX1---5.8GWIFI 93 13. TEST SETUP PHOTO 124 14. EUT CONSTRUCTIONAL DETAILS 124 Project No.: ZKT-221125L8872-04 Page 5 of 124 1. VERSION Report No. Version Description Approved ZKT-221125L8872-04 Rev.01 Initial issue of report Nov. 30, 2022 Project No.: ZKT-221125L8872-04 Page 6 of 124 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Result Remark 15.203/15.247 (c) Antenna requirement PASS 15.207 AC Power Line Conducted Emission PASS 15.407 (a) (b) Spurious Radiated Emissions and Band Edge PASS 15.407 (e) /15.403(i) 6 dB bandwidth, 26dB Emission Bandwidth& 99% Occupied Bandwidth PASS 15.407 (a) Power Spectral Density PASS 15.407 (a)(1)(2)(3) Maximum conducted output power PASS 15.407 (g) Frequency Stability PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Project No.: ZKT-221125L8872-04 Page 7 of 124 2.1 TEST FACILITY Shenzhen ZKT Technology Co., Ltd. Add. : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China FCC Test Firm Registration Number: 692225 Designation Number: CN1299 IC Registered No.: 27033 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %。 Project No.: ZKT-221125L8872-04 Page 8 of 124 3. GENER…

Text truncated - open the document above for the full version.

Test Report

Project No.: ZKT-221125L8872-04 Page 76 of 124 Power_Spectral_Density_5_2GWiFi_802_11n(HT20)_5200_20M Power_Spectral_Density_5_2GWiFi_802_11n(HT20)_5240_20M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5180_20M Project No.: ZKT-221125L8872-04 Page 77 of 124 Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5200_20M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5240_20M Power_Spectral_Density_5_2GWiFi_802_11n(HT40)_5190_40M Project No.: ZKT-221125L8872-04 Page 78 of 124 Power_Spectral_Density_5_2GWiFi_802_11n(HT40)_5230_40M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT40)_5190_40M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT40)_5230_40M Project No.: ZKT-221125L8872-04 Page 79 of 124 Power_Spectral_Density_5_2GWiFi_802_11ac(VHT80)_5210_80M ANT2 Power_Spectral_Density_5_2GWiFi_802_11a_5180_20M Project No.: ZKT-221125L8872-04 Page 80 of 124 Power_Spectral_Density_5_2GWiFi_802_11a_5200_20M Power_Spectral_Density_5_2GWiFi_802_11a_5240_20M Power_Spectral_Density_5_2GWiFi_802_11n(HT20)_5180_20M Project No.: ZKT-221125L8872-04 Page 81 of 124 Power_Spectral_Density_5_2GWiFi_802_11n(HT20)_5200_20M Power_Spectral_Density_5_2GWiFi_802_11n(HT20)_5240_20M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5180_20M Project No.: ZKT-221125L8872-04 Page 82 of 124 Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5200_20M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT20)_5240_20M Power_Spectral_Density_5_2GWiFi_802_11n(HT40)_5190_40M Project No.: ZKT-221125L8872-04 Page 83 of 124 Power_Spectral_Density_5_2GWiFi_802_11n(HT40)_5230_40M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT40)_5190_40M Power_Spectral_Density_5_2GWiFi_802_11ac(VHT40)_5230_40M Project No.: ZKT-221125L8872-04 Page 84 of 124 Power_Spectral_Density_5_2GWiFi_802_11ac(VHT80)_5210_80M Project No.: ZKT-221125L8872-04 Page 85 of 124 4. Bandedge ANT1 Bandedge_5_2GWiFi_802_11a_5180_20M Bandedge_5_2GWiFi_802_11a_5240_20M Bandedge_5_2GWiFi_802_11n(HT20)_5180_20M Project No.: ZKT-221125L8872-04 Page 86 of 124 Bandedge_5_2GWiFi_802_11n(HT20)_5240_20M Bandedge_5_2GWiFi_802_11ac(VHT20)_5180_20M Bandedge_5_2GWiFi_802_11ac(VHT20)_5240_20M Project No.: ZKT-221125L8872-04 Page 87 of 124 Bandedge_5_2GWiFi_802_11n(HT40)_5190_40M Bandedge_5_2GWiFi_802_11n(HT40)_5230_40M Bandedge_5_2GWiFi_802_11ac(VHT40)_5190_40M Project No.: ZKT-221125L8872-04 Page 88 of 124 Bandedge_5_2GWiFi_802_11ac(VHT40)_5230_40M Bandedge_5_2GWiFi_802_11ac(VHT80)_5210_80M Project No.: ZKT-221125L8872-04 Page 89 of 124 ANT2 Bandedge_5_2GWiFi_802_11a_5180_20M Bandedge_5_2GWiFi_802_11a_5240_20M Bandedge_5_2GWiFi_802_11n(HT20)_5180_20M Project No.: ZKT-221125L8872-04 Page 90 of 124 Bandedge_5_2GWiFi_802_11n(HT20)_5240_20M Bandedge_5_2GWiFi_802_11ac(VHT20)_5180_20M Bandedge_5_2GWiFi_802_11ac(VHT20)_5240_20M Project No.: ZKT-221125L8872-04 Page 91 of 124 Bandedge_5_2GWiFi_802_11n(HT40)_5190_40M Bandedge_5_2GWiFi_802_11n(HT40)_5230_40M Bandedge_5_2GWiFi_802_11ac(VHT40)_5190_40M Project No.: ZKT-221125L8872-04 Page 92 of 124 Bandedge_5_2GWiFi_802_11ac(VHT40)_5230_40M Bandedge_5_2GWiFi_802_11ac(VHT80)_5210_80M Project No.: ZKT-221125L8872-04 Page 93 of 124 12.APPENDIX1---5.8GWIFI 1. -6dB Emission Bandwidth Condition Antenna Mode Frequency(MHz) -6dB_Emission_Bandwidth(MHz) Limit(MHz) Result NVNT ANT1 LCH 5745.00 16.333 0.500 Pass NVNT ANT1 MCH 5785.00 16.353 0.500 Pass NVNT ANT1 HCH 5825.00 16.361 0.500 Pass NVNT ANT1 LCH 5745.00 16.352 0.500 Pass NVNT ANT1 MCH 5785.00 17.324 0.500 Pass NVNT ANT1 HCH 5825.00 17.189 0.500 Pass NVNT ANT1 LCH 5745.00 17.572 0.500 Pass NVNT ANT1 MCH 5785.00 17.572 0.500 Pass NVNT ANT1 HCH 5825.00 17.187 0.500 Pass NVNT ANT1 LCH 5755.00 35.520 0.500 Pass NVNT ANT1 HCH 5795.00 35.321 0.500 Pass NVNT ANT1 LCH 5755.00 35.174 0.500 Pass NVNT ANT1 HCH 5795.00 35.153 0.500 Pass NVNT ANT1 MCH 5775.00 75.054 0.500 Pass Condition Antenna Mode Frequency(MHz) -6dB_Emission_Bandwidth(MHz) Limit(MHz) Result NVNT ANT2 LCH 5745.00 16.345 0.500 Pass NVNT ANT2 MCH 5785.00 16.382 0.500 Pass NVNT ANT2 HCH 5825.00 16.359 0.500 Pass NVNT ANT2 LCH 5745.00 17.311 0.500 Pass NVNT ANT2 MCH 5785.00 17.569 0.500 Pass NVNT ANT2 HCH 5825.00 17.572 0.500 Pass NVNT ANT2 LCH 5745.00 17.168 0.500 Pass NVNT ANT2 MCH 5785.00 17.328 0.500 Pass NVNT ANT2 HCH 5825.00 17.352 0.500 Pass NVNT ANT2 LCH 5755.00 35.164 0.500 Pass NVNT ANT2 HCH 5795.00 35.154 0.500 Pass NVNT ANT2 LCH 5755.00 35.072 0.500 Pass NVNT ANT2 HCH 5795.00 35.127 0.500 Pass NVNT ANT2 MCH 5775.00 75.077 0.500 Pass ANT1 -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5785_20M Project No.: ZKT-221125L8872-04 Page 94 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5825_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5785_20M Project No.: ZKT-221125L8872-04 Page 95 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5825_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT20)_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT20)_5785_20M Project No.: ZKT-221125L8872-04 Page 96 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT20)_5825_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT40)_5755_40M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT40)_5795_40M Project No.: ZKT-221125L8872-04 Page 97 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT40)_5755_40M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT40)_5795_40M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT80)_5775_80M Project No.: ZKT-221125L8872-04 Page 98 of 124 ANT2 -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5785_20M Project No.: ZKT-221125L8872-04 Page 99 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11a_5825_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5785_20M Project No.: ZKT-221125L8872-04 Page 100 of 124 -6dB_Emission_Bandwidth_5_8GWiFi_802_11n(HT20)_5825_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT20)_5745_20M -6dB_Emission_Bandwidth_5_8GWiFi_802_11ac(VHT20)_5785_20M Project No…

Text truncated - open the document above for the full version.

Test Report

Purpose This report is to measure the performance of SLK for Master Antenna . All measure date are showed below. Content 1. Product Overview 2.Test Result 2.1 WIFI Antenna VSWR 2.2 Antenna parameters 2.3 WIFI 1/2 Antenna Gain/Efficiency/3D DATE 2.4 Antenna Throughput data 3. Conclusions ANTENNA TEST REPORT TP :Shenzhen Ugoos Technology Co., Ltd MN: PCB_ANT_PA-110 RF: XINGYUANCHUANG TECHNOLOGY 1. Product Overview & Dimension WIFI 1 天线 WIFI 2 天线 2. Test Result 2.1 WIFI 1 Antenna VSWR/S11 2. Test Result 2.1 WIFI 2 Antenna VSWR/S11 2. Test Result 2.2 Antenna parameters 2. Test Result 2.3 WIFI Antenna Gain/Efficiency/3D DATE X Y Z 2. Test Result 2.3 WIFI 1 Antenna Gain/Efficiency/3D DATE X Y Z 2. Test Result 2.3 WIFI 2 Antenna Gain/Efficiency/3D DATE 2. Test Result 2.4 Antenna Throughput data

Test Setup Photos

Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q Radiated Emission Project No.: ZKT-221125L8872-01 FCC ID: 2AL8Y-X4Q Conducted Emission

Contact Information

Applicant

James Liu(Manager)
[email protected]+8613640970241Fax: +86-0755-25472852

Technical Contact

Shenzhen Ugoos Technology Co., Ltd
[email protected]

China

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz57.54 mW
Confidentiality
Long Term
Grant Notes
Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Ugoos Technology Co., Ltd

Android TV Box - FCC ID 2AL8Y-SK4 - Shenzhen Ugoos Technology Co., Ltd
2AL8Y-SK4

Android TV Box

Dec 05, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
android tv box - FCC ID 2AL8Y-SK1 - Shenzhen Ugoos Technology Co., Ltd
2AL8Y-SK1

android tv box

Aug 08, 2024

Equipment Class

DTS - Digital Transmission System
android tv box - FCC ID 2AL8Y-AM8 - Shenzhen Ugoos Technology Co., Ltd
2AL8Y-AM8

android tv box

Sep 17, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter