FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. myFirst Tech Asia Pte. Ltd./
  3. 2ALET-KW1305

2ALET-KW1305myFirst Fone R1s

myFirst Tech Asia Pte. Ltd.
myFirst Fone R1s - FCC ID 2ALET-KW1305 - myFirst Tech Asia Pte. Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 12, 2023
Application Purpose
Original Equipment
Date of Application
Jan 12, 2023
Equipment Note
myFirst Fone R1s
Frequency Range
2402.00000000 - 2480.00000000
Company
myFirst Tech Asia Pte. Ltd.
Country
Singapore

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

-Donotallowdustordirttoenterthedevice. -Donotdroporhitthedevice.Carelesshandlingcanleadto damageoftheintegratedboardandmechanicalparts. -Chargeroutputmustbe:5V1A. -Makesuretoinputthecorrectphonenumber,includingthe countrycode.Forexample:+(countrycode)xxxxxx.Donotuse symbolssuchas'(',')','-',''. -Photosharingfunction,callsandautomaticupdatescanconsume a large amount of data. Choose the appropriate carrier plan and set the Wi-Fi passwords for frequently visited places. Regulatory Conformance:Hereby, Oaxis Asia Pte Ltd declares that the radio equipment type KW1305 is in compliance with Directive 2014/53/EU.Note: Observe the national local regulations in the location where the device is to be used. This device may be restricted for use in some or all member states of the European Union (EU). FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Caution:Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF ExposureInformation Specific Absorption Rate (SAR) information: This Communicator meets the government's requirements for exposure to radio waves.The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health.FCC RFExposure Information and Statement the SAR limit of USA (FCC) is 1.6W/kg averaged over one gram of tissue.Device types: Communicator has also been tested against this SAR limit.The device has been tested for typical Limb-worn operation, with the back of the watch held 0mm, Body-worn operationfrom, with the Front of the watch held 10mm.To maintain compliance with FCC RF exposure requirements, use accessories that maintain an 0mm separation distance between the user's body and the back of the phone.The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly.The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

External Photos

Page1of4FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L1.0cmxW0.5cm) Thesampleistoosmall,thelabelisreflectedontheinstructionmanualandtheouterbox LabelLocation FCCID:2ALET-KW1305

Internal Photos

Page1of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of7FCCID:2ALET-KW1305 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13 Fig.14 BT/WIFIAntenna 2G/3G/4GMAINANT

RF Exposure Info

Page1of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity SARTESTREPORT For OaxisAsiaPteLtd myFirstFoneR1s TestModel:KW1305 Preparedfor:OaxisAsiaPteLtd Address:31WoodlandsClose#01-22Singapore Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:(86)755-82591330 Fax:(86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:November25,2022 Numberoftestedsamples SampleNo : : 2 A112122076-1,A112122076-2 Serialnumber:Prototype DateofTest:November25,2022~December13,2022 DateofReport:December22,2022 Page2of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity SARTESTREPORT ReportReferenceNo.................: LCSA112122076EB DateOfIssue...............................:December22,2022 TestingLaboratoryName........:ShenzhenLCSComplianceTestingLaboratoryLtd. Address........................................:101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen,518000, China TestingLocation/Procedure........:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName......................: OaxisAsiaPteLtd Address........................................: 31WoodlandsClose#01-22Singapore TestSpecification: Standard.......................................: IEEEStdC95.1,2019/IEEEStd1528™-2013/FCCPart2.1093 TestReportFormNo...................:LCSEMC-1.0 TRFOriginator............................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF..................................:Dated2014-09 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription................:myFirstFoneR1s TradeMark..................................: myFirst TestModel...................................:KW1305 OperationFrequency...................: GSM850,1900;WCDMAII/IV/V; LTE2,4,5,12,17,25,41;WLAN2.4GandBluetooth4.2. Ratings.........................................: Input:DC5V DC3.7VbyRechargeableLi-ionBattery,580mAh Result.........................................: Positive Compiledby:Supervisedby:Approvedby: JayZhan/Fileadministrators CaryLuo/TechniqueprincipalGavinLiang/Manager Page3of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity SAR--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA112122076EB December22,2022 Dateofissue TestModel...........................:KW1305 EUT.......................................:myFirstFoneR1s Applicant..............................:OaxisAsiaPteLtd Address..................................:31WoodlandsClose#01-22Singapore Telephone..............................:/ Fax.........................................:/ Manufacturer.......................: OaxisAsiaPteLtd Address..................................: 31WoodlandsClose#01-22Singapore Telephone..............................:/ Fax.........................................:/ Factory..................................:UMEOXInnovationsCo.,Ltd Address..................................:Room08-09,Floor12,KeYanBldg,TsinghuaHighTechPark, XinDongRoad1,NanShan,Shenzhen,China Telephone..............................:/ Fax.........................................:/ Page4of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisonHistory RevisionIssueDate RevisionContent RevisedBy 000December22,2022 InitialIssue--- Page5of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.TESTSTANDARDSANDTESTDESCRIPTION.....................................................................................................................6 1.1.TESTSTANDARDS....................................................................................................................................................................6 1.2.TESTDESCRIPTION.................................................................................................................................................................6 1.3.GENERALREMARKS................................................................................................................................................................6 1.4.PRODUCTDESCRIPTION........................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page111of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page112of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page113of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page114of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 5.3SID835DipoleCalibrationCeriticate Page115of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page116of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page117of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page118of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page119of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page120of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page121of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page122of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page123of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page124of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page125of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 5.4SID1800DipoleCalibrationCertificate Page126of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page127of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page128of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page129of171FCCID:2ALET-KW1305ReportNo.:LCSA112122076EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page130of171FCC…

Text truncated - open the document above for the full version.

Test Report

Page1of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBT(ConductedMeasurement) ProductName:myFirstFoneR1s TestModel:KW1305 EnvironmentalConditions Temperature: 23.2 ď‚° C RelativeHumidity:52.1% ATMPressure:100.0kPa TestEngineer:LingZhu Supervisedby:LiHuan Page2of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-20dBBandwidth ConditionModeFrequency(MHz)Antenna-20dBBandwidth(MHz)Limit-20dBBandwidth(MHz)Verdict NVNT1-DH52402Ant11.004N/APass NVNT1-DH52441Ant11.021N/APass NVNT1-DH52480Ant11.014N/APass NVNT2-DH52402Ant11.289N/APass NVNT2-DH52441Ant11.287N/APass NVNT2-DH52480Ant11.291N/APass NVNT3-DH52402Ant11.272N/APass NVNT3-DH52441Ant11.264N/APass NVNT3-DH52480Ant11.28N/APass Page3of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page4of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page5of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page6of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT3-DH52402MHzAnt1 -20dBBandwidthNVNT3-DH52441MHzAnt1 Page7of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT3-DH52480MHzAnt1 Page8of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNT1-DH52402Ant10.5921Pass NVNT1-DH52441Ant10.721Pass NVNT1-DH52480Ant10.721Pass NVNT2-DH52402Ant10.5721Pass NVNT2-DH52441Ant10.3721Pass NVNT2-DH52480Ant10.1221Pass NVNT3-DH52402Ant10.3421Pass NVNT3-DH52441Ant10.5121Pass NVNT3-DH52480Ant10.2521Pass Page9of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page10of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page11of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page12of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT3-DH52402MHzAnt1 PowerNVNT3-DH52441MHzAnt1 Page13of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT3-DH52480MHzAnt1 Page14of54FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1(MHz)HoppingFreq2(MHz)HFS(MHz)Limit(MHz)Verdict NVNT1-DH5Ant12401.992402.8840.8940.681Pass NVNT2-DH5A…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 37 FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR OaxisAsiaPteLtd myFirstFoneR1s TestModel:KW1305 Preparedfor:OaxisAsiaPteLtd Address:31WoodlandsClose#01-22Singapore Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:November25,2022 Numberoftestedsamples:2 SampleNo. : A112122076-1,A112122076-2 Serialnumber:Prototype DateofTest:November25,2022~December13,2022 DateofReport:December14,2022 Page 2 of 37 FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA112122076EA DateofIssue.......................................:December14,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................: OaxisAsiaPteLtd Address................................................: 31WoodlandsClose#01-22Singapore TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:myFirstFoneR1s TradeMark..........................................:myFirst TestModel...........................................:KW1305 Ratings.................................................:Input:DC5V DC3.7VbyRechargeableLi-ionBattery,580mAh Result..................................................:Positive Compiledby:Supervisedby:Approvedby: RoryHuang/Administrator CaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 37 FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA112122076EA December14,2022 Dateofissue TestModel.............................. : KW1305 EUT......................................... : myFirstFoneR1s Applicant...............................:OaxisAsiaPteLtd Address...................................:31WoodlandsClose#01-22Singapore Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:OaxisAsiaPteLtd Address...................................:31WoodlandsClose#01-22Singapore Telephone...............................:/ Fax..........................................:/ Factory...................................: UMEOXInnovationsCo.,Ltd Address...................................: Room08-09,Floor12,KeYanBldg,TsinghuaHighTech Park,XinDongRoad1,NanShan,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Page 4 of 37 FCCID:2ALET-KW1305ReportNo.:LCSA112122076EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:webmaster@lcs-cert.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ying Keong Chaw(Mr)
[email protected]92221475Fax: 67791685

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from myFirst Tech Asia Pte. Ltd.

myFirst Watch F1 - FCC ID 2ALET-KW1801 - myFirst Tech Asia Pte. Ltd.
2ALET-KW1801

myFirst Watch F1

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2ALET-FH9407

Bluetooth headphone

Dec 05, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
myFirst Camera 50 - FCC ID 2ALET-FC4001 - myFirst Tech Asia Pte. Ltd.
2ALET-FC4001

myFirst Camera 50

Sep 17, 2024

Equipment Class

DTS - Digital Transmission System
myFirst CareBuds - FCC ID 2ALET-FH8505 - myFirst Tech Asia Pte. Ltd.
2ALET-FH8505

myFirst CareBuds

May 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter