2ALP7BB1002SafeX / TagX

BlueUp
SafeX / TagX - FCC ID 2ALP7BB1002 - BlueUp
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 03, 2025
Application Purpose
Original Equipment
Equipment Note
SafeX / TagX
Frequency Range
2402.00000000 - 2480.00000000
Company
BlueUp
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BlueUp S.r.l. Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d'Elsa (SI) Ph. +39 344 2030929 / +39 0577 043101 E-mail: [email protected], Web: www.blueupbeacons.com P.IVA/CF/VAT N. IT01373980521 SafeX User manual Introduction BlueUp SafeX, in its variants SafeX Classic, SafeX Watch and SafeX Lite, henceforth identified with the terms “product”, “device” or “beacon”, is a Bluetooth Low Energy (BLE) beacon for proximity applications. BlueUp SafeX can support different technologies: standard Bluetooth (TM) LE (BLE), Quuppa Intelligent Locating System (Quuppa), Wirepas 2.4GHz Mesh (Wirepas). Tracer contact-tracing (Tracer) It integrates: call button, 2 LEDs, vibration motor (optional), buzzer (optional), T/H sensor (optional) BlueUp SafeX is powered by 1x 3V lithium battery, mod. CR2477. Before you start using a BlueUp device, verify that it is undamaged and carefully read the instructions in this user manual, particularly the indications in the "Safety" section. BlueUp S.r.l. disclaims any and all liability if the devices are used in modes and environments incompatible for keeping the product intact, safe and in operation. Procedures The beacon is provided with battery inserted. It is immediately active. Configuration and activation depends on supported technology: BLE BLE version has two alternative variants: BLE beacon: to modify beacon configurations, use free configuration app provided by BlueUp and available for iPhone / iPad (Apple Store) and Android (Google Play): –Configuration app: BlueBeacon Manager –Default password: blueup BLE bleenc: requires bleenc® software infrastructure For information on configuration, on services and characteristics, and on all use aspects, please refer to the technical information in the Products and Support page of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Quuppa Beacon settings can be updated using Quuppa Site Planner. For technical details, please refer to the technical information in the Support Center of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Wirepas Beacon can operate as a mobile tag, depending on production configuration. Settings can be updated using Wirepas Network Tool or MeshCube interface. For technical details, please refer to the technical information in the Support Center of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Tracer SafeX Tracer starts in Configuration mode. To initialize the device download SafeX Tracer Manager App from Tracer portal (tracer.blueupbeacons.com). Once initialized the device starts working as configured, for contact-tracing and distance warning functionalities. Contact events data can be downloaded with Manager app, Kiosk app or dedicated gateway. BlueUp S.r.l. - 2025V3.0 – Nov. 20251/4 Safety These information are an integral and essential part of the product and must be delivered to the user. Read them carefully as they contain important information regarding the installation, use and maintenance. Warnings The device is a professional device whose intended use is aimed at professions or industries and which is not intended for sale to the general public. The product is a wireless device. The product must be intended for use for which it was designed. Any other use is considered improper and therefore dangerous. Operating conditions: temperature -20/+60°C; humidity 20-80%. Before you start using the beacon, verify that it is undamaged. DO NOT use the beacon in potentially explosive atmospheres. The presence of flammable gas or fumes is a serious safety hazard. The product is a wireless device. Please be attentive in its use, in the case of use near (less than 5 cm) a pacemaker or other electronic medical life-saving devices as it transmits radio waves that can interfere with the proper functioning of these devices. Contact medical device manufacturer for more information. The company BlueUp S.r.l. disclaims any liability for damages caused by an inadequate use of the device and the failure to observe the information provided herein. Battery BlueUp SafeX is powered by one coin battery, according to the following table: Battery Q.tyCommon nameIEC60086 nameTypeNominal voltage 1CR2477CR2477Lithium (LiMnO2)3V Battery replacement Battery replacement must be performed by an adult. To replace the battery, follow the instructions below: 1. unscrew the 4 screws on the back cover; 2. remove the circuit from its housing, handling the circuit only by the edges 3. remove the battery from the battery holder 4. insert the new battery in the battery holder, paying attention to the polarity indicated on the battery holder 5. insert the circuit in its housing, handling the circuit only by the edges and paying attention to the position of the LED which must coincide with that of the hole on the cover 6. screw the 4 screws on the back cover CAUTION DO NOT power the device with other batteries. Explosion hazard if battery is replaced with the wrong type. DO NOT insert the batteries into the battery holder with the positive and negative contacts reversed. DO NOT disassemble, puncture or damage the batteries. DO NOT recharge the batteries. BlueUp S.r.l. - 2025V3.0 – Nov. 20252/4 DO NOT short the positive and negative contacts of the batteries. DO NOT cause a forced depletion of the batteries. DO NOT throw the batteries in fire. DO NOT place the batteries in the following environmental conditions: in the vicinity of heat sources, exposed to direct sunlight, high temperatures, high humidity, extremely-low pressure, in contact with water. DO NOT handle the battery with metal objects (such as forceps, scissors,...). In general, avoid the metal contacts on the battery from coming into contact with other metal objects, including other batteries. This could cause a short circuit, damage the battery and cause overheating or explosion. If the battery is stored or thrown away, ma…

Text truncated - open the document above for the full version.

Users Manual

BlueUp S.r.l. Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d'Elsa (SI) Ph. +39 344 2030929 / +39 0577 043101 E-mail: [email protected], Web: www.blueupbeacons.com P.IVA/CF/VAT N. IT01373980521 TagX User manual Introduction BlueUp TagX, henceforth identified with the terms “product”, “device” or “beacon”, is a Bluetooth Low Energy (BLE) beacon for proximity applications. BlueUp TagX can support different technologies: standard Bluetooth (TM) LE (BLE), Quuppa Intelligent Locating System (Quuppa), Wirepas 2.4GHz Mesh (Wirepas) BlueUp TagX is available in the following variants: TagX (STD): standard version; TagX LED: with high-visibility 2x LEDs; TagX BUT: with call button and 2x LEDs; TagX SHT: with temperature amd humidity sensor. BlueUp TagX is powered by 1x 3V lithium battery, mod. CR2477. Before you start using a BlueUp device, verify that it is undamaged and carefully read the instructions in this user manual, particularly the indications in the "Safety" section. BlueUp S.r.l. disclaims any and all liability if the devices are used in modes and environments incompatible for keeping the product intact, safe and in operation. Procedures The beacon is provided with battery inserted. It is immediately active. Configuration and activation depends on supported technology: BLE BLE version has two alternative variants: BLE beacon: to modify beacon configurations, use free configuration app provided by BlueUp and available for iPhone / iPad (Apple Store) and Android (Google Play): –Configuration app: BlueBeacon Manager –Default password: blueup BLE bleenc: requires bleenc® software infrastructure For information on configuration and on all use aspects, please refer to the technical information in the Products and Support page of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Quuppa Beacon settings can be updated using Quuppa Site Planner. For technical details, please refer to the technical information in the Support Center of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Wirepas Beacon can operate as a mobile tag, depending on production configuration. Settings can be updated using Wirepas Network Tool on MeshCube interface. For technical details, please refer to the technical information in the Support Center of the website www.blueupbeacons.com or contact technical assistance at [email protected]. Once initialized the device starts working as configured, for contact-tracing and distance warning functionalities. Contact events data can be downloaded with Manager app, Kiosk app or dedicated gateway. BlueUp S.r.l. - 2025V3.0 – Nov. 20251/4 Safety These information are an integral and essential part of the product and must be delivered to the user. Read them carefully as they contain important information regarding the installation, use and maintenance. Warnings The device is a professional device whose intended use is aimed at professions or industries and which is not intended for sale to the general public. The product is a wireless device. The product must be intended for use for which it was designed. Any other use is considered improper and therefore dangerous. Operating conditions: temperature -20/+60°C; humidity 20-80%. Before you start using the beacon, verify that it is undamaged. DO NOT use the beacon in potentially explosive atmospheres. The presence of flammable gas or fumes is a serious safety hazard. The company BlueUp S.r.l. disclaims any liability for damages caused by an inadequate use of the device and the failure to observe the information provided herein. Battery BlueUp TagX is powered by one coin battery, according to the following table: Battery Q.tyCommon nameIEC60086 nameTypeNominal voltage 1CR2477CR2477Lithium (LiMnO2)3V Battery replacement Battery replacement must be performed by an adult. To replace the battery, follow the instructions below: 1. unscrew the 4 screws on the back cover; 2. remove the circuit from its housing, handling the circuit only by the edges 3. remove the battery from the battery holder 4. insert the new battery in the battery holder, paying attention to the polarity indicated on the battery holder 5. insert the circuit in its housing, handling the circuit only by the edges 6. screw the 4 screws on the back cover CAUTION DO NOT power the device with other batteries. Explosion hazard if battery is replaced with the wrong type. DO NOT insert the batteries into the battery holder with the positive and negative contacts reversed. DO NOT disassemble, puncture or damage the batteries. DO NOT recharge the batteries. DO NOT short the positive and negative contacts of the batteries. DO NOT cause a forced depletion of the batteries. BlueUp S.r.l. - 2025V3.0 – Nov. 20252/4 DO NOT throw the batteries in fire. DO NOT place the batteries in the following environmental conditions: in the vicinity of heat sources, exposed to direct sunlight, high temperatures, high humidity, extremely-low pressure, in contact with water. DO NOT handle the battery with metal objects (such as forceps, scissors,...). In general, avoid the metal contacts on the battery from coming into contact with other metal objects, including other batteries. This could cause a short circuit, damage the battery and cause overheating or explosion. If the battery is stored or thrown away, make sure it is covered individually with insulating tape. DO NOT swallow the battery. Chemical burn hazard. This product contains a coin cell battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and result in death. Keep new and used batteries out of the reach of children. If the battery compartment does not close tightly, stop using the product and keep it out of the reach of children. In the event of suspected ingestion of the batteries or their insertion into other body orifices, seek medical advice immediately. Waste disposal In implementing the Di…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 BlueUp Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-11-25 FCC ID: 2ALP7BB1002 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing BlueUp certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. BlueUp certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing BlueUp certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. pplicant: BlueUp Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Contact Person: Alessio Cucini Tel.: 3474123206 Email: [email protected] Sincerely, Signature:

Attestation Statements

Attestation Statements Date: TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, 2025-11-27 USA BlueUp, the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated agent for service of process, BlueUp accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2ALP7BB1002) related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: BlueUp Contact Name: Alessio Cucini Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Telephone No: 3474123206 Email: [email protected] FRN: 0026411165 Signature: Alessio Cucini Agent Information: Company Name:HOPEK CORPORATION INC Address:16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN:0034562900 Contact Name:Peter Davis Telephone No:561-235-6113 Email:[email protected] Signature: Peter Davis

Cover Letter(s)

BlueUp Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: November 27, 2025 Subject; Request for Confidentiality FCC ID: 2ALP7BB1002 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Alessio Cucini Title: Managing Director

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 BlueUp Date:2025-11-25 Product Model Number: SafeX, SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT FCC ID:2ALP7BB1002 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Alessio Cucini Contact Listed on FCC Wesbite Title: Managing Director Email: [email protected] On behalf of: BlueUp

Cover Letter(s)

BlueUp Declaration Letter of Model Difference Date: 2025-11-25 FCC ID: 2ALP7BB1002 Tested Model Number: SafeX Adding Model Number(s): SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT All Adding Model Number(s) is/are same electrically identical as Tested Model Number. Only the model and appearance are different. Yours Sincerely, Applicant: BlueUp Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Contact Person: Alessio Cucini Tel.: 3474123206 Email: [email protected] Sincerely, Signature:

Cover Letter(s)

BlueBeacon SafeX/TagX Antenna specification Antenna technology: Printed on PCB Antenna type: PIFA (Planar Inverted-F Antenna) Peak Gain: 0.5dBi 3D Gain at 2450MHz Manufacturer: BlueUp Srl Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy 12.5mm 5mm Antenna Radiation Patterns at 2450MHz YZ Plane XZ Plane

External Photos

Page 1 of 4 Report No.: LGT25K095 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 4 Report No.: LGT25K095 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 4 Report No.: LGT25K095 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 4 Report No.: LGT25K095 Appendix - External Photographs of EUT Constructional Details Photo 7 Photo 8

ID Label/Location Info

Label

Internal Photos

Page 1 of 3 Report No.: LGT25K095 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 3 Report No.: LGT25K095 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 BT ANT Page 3 of 3 Report No.: LGT25K095 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: SafeX / TagX Model Number: SafeX, SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT FCC ID: 2ALP7BB1002 Issued For : BlueUp Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25K095HA01 Sample Received Date: Nov. 14, 2025 Date of Test: Nov. 14, 2025 ~ Nov. 25, 2025 Date of Issue: Nov. 25, 2025 Report No.: LGT25K095HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: BlueUp Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Manufacturer: BlueUp Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Product Name: SafeX / TagX Trademark: BlueUp Model Number: SafeX, SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1093 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25K095HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1093 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 TEST RESULT 8 Report No.: LGT25K095HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Nov. 25, 2025 Initial Issue Report No.: LGT25K095HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: SafeX / TagX Test Model Number: SafeX Series Number: SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT Model Difference: Only the model and appearance are different. Frequency Bands: Bluetooth 2402~2480 MHz Battery: Capacity: 1000mAh Rated Voltage: 3V Hardware Version: 1.0 Software Version: 1.0 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT25K095HA01 Page 6 of 8 2. FCC 47CFR §2.1093 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in KDB 447498 D01 General RF Exposure Guidance v06 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. Report No.: LGT25K095HA01 Page 7 of 8 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Report No.: LGT25K095HA01 Page 8 of 8 2.3 TEST RESULT Turn up Result Mode Turn up Power BLE 1M-GFSK -0.5±1dBm The MPE result of worst mode: RF Function Frequency (MHz) Max Turn up Power (dBm) Max Turn up Power (mW) Estimated SAR Limit Ratio Result BLE 2402 0.50 1.12 0.348 3 0.116 Pass Note: 1. The RF Exposure is less than the limit, complies with the exemption requirements. . ※※※※※END OF THE REPORT※※※※※

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 41 RF TEST REPORT Product Name: SafeX / TagX Model Number: SafeX, SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT FCC ID: 2ALP7BB1002 Issued For : BlueUp Srl Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25K095RF01 Sample Received Date: Nov. 14, 2025 Date of Test: Nov. 14, 2025 ~ Nov. 25, 2025 Date of Issue: Nov. 25, 2025 Report No.: LGT25K095RF01 Page 2 of 41 TEST REPORT CERTIFICATION Applicant: BlueUp Srl Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Manufacturer: BlueUp Srl Address: Loc. Belvedere, Ingresso 2, 99, 53034 Colle di Val d’Elsa, Italy Product Name: SafeX / TagX Trademark: BlueUp Model Number: SafeX, SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT25K095RF01 Page 3 of 41 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 12 3.1 CONDUCTED EMISSION MEASUREMENT 12 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 EUT OPERATING CONDITIONS 13 3.5 TEST RESULTS 13 4. RADIATED EMISSION MEASUREMENT 14 4.1 RADIATED EMISSION LIMITS 14 4.2 TEST PROCEDURE 16 4.3 TEST SETUP 16 4.4 EUT OPERATING CONDITIONS 17 4.5 FIELD STRENGTH CALCULATION 17 4.6 TEST RESULTS (BAND EDGE REQUIREMENTS) 22 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 23 5.1 LIMIT 23 5.2 TEST PROCEDURE 23 5.3 TEST SETUP 23 5.4 EUT OPERATION CONDITIONS 23 5.5 TEST RESULTS 23 6. POWER SPECTRAL DENSITY TEST 24 6.1 LIMIT 24 6.2 TEST PROCEDURE 24 6.3 TEST SETUP 24 6.4 EUT OPERATION CONDITIONS 24 Report No.: LGT25K095RF01 Page 4 of 41 6.5 TEST RESULTS 24 7. BANDWIDTH TEST 25 7.1 LIMIT 25 7.2 TEST PROCEDURE 25 7.3 TEST SETUP 25 7.4 EUT OPERATION CONDITIONS 25 7.5 TEST RESULTS 25 8. PEAK OUTPUT POWER TEST 26 8.1 LIMIT 26 8.2 TEST PROCEDURE 26 8.3 TEST SETUP 26 8.4 EUT OPERATION CONDITIONS 26 8.5 TEST RESULTS 26 9. ANTENNA REQUIREMENT 27 9.1 STANDARD REQUIREMENT 27 9.2 EUT ANTENNA 27 APPENDIX I - TEST RESULTS 28 1. DUTY CYCLE 28 2. BANDWIDTH 30 3. MAXIMUM CONDUCTED OUTPUT POWER 33 4. MAXIMUM POWER SPECTRAL DENSITY 35 5. UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS 37 APPENDIX II - MEASUREMENT PHOTOS 41 Report No.: LGT25K095RF01 Page 5 of 41 Revision History Rev. Issue Date Revisions 00 Nov. 25, 2025 Initial Issue Report No.: LGT25K095RF01 Page 6 of 41 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 Part 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Report No.: LGT25K095RF01 Page 7 of 41 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB 9 Temperature ±0.5°C 10 Humidity ±2% 11 Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT25K095RF01 Page 8 of 41 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: SafeX / TagX Test Model Number: SafeX Series Number: SafeX Classic, SafeX Lite, SafeX Watch, TagX, TagX STD, TagX BUT, TagX LED, TagX SHT Model Difference: Only the model and appearance are different. Product Description: Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Radio Technology: BLE Bluetooth Configuration: BLE (1M PHY) Number Of Channel: 40 Antenna Designation: PIFA Antenna Antenna Gain (dBi) 0.5 Channel List: Please refer to the Note 3. Battery: Capacity: 1000mAh Rated Voltage: 3V Hardware Vers…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alessio Cucini(Eng. PhD.)
[email protected]Fax: 0577043101

Test Firm

Shenzhen LGT Test Service Co., Ltd.Wen Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz970.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.