2ALVK-HANP1TWIRELESS HEADPHONES

Cosonic Intelligent Technologies Co.,Ltd.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 09, 2024
Application Purpose
Original Equipment
Date of Application
Sep 09, 2024
Equipment Note
WIRELESS HEADPHONES
Frequency Range
2402.00000000 - 2480.00000000
Company
Cosonic Intelligent Technologies Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Cosonic Intelligent Technologies Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-7-31 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2ALVK-HANP1T Cosonic Intelligent Technologies Co.,Ltd. ("the applicant")certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicantsignature) (Applicant printed name) Nick Yu Rev 1/26/2023 Cosonic Intelligent Technologies Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-7-31 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2ALVK-HANP1T Cosonic Intelligent Technologies Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List(as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Nick Yu

Attestation Statements

[Cosonic Intelligent Technologies Co.,Ltd.] [5th Floor,1st Building,No.6 South Industry Road, Songshan Lake Hi-tech Industrial Development Zone, Dongguan, Guangdong, China] Date: [2024-7-31] Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: [2ALVK-HANP1T] FRN: [0022729867] US Agent – Attestation Statement / Part 2.911(d)(7) [ Cosonic Intelligent Technologies Co.,Ltd.] certifies, that as of [2024-7-31], we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: [2ALVK-HANP1T]. [Cosonic Intelligent Technologies Co.,Ltd.], accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of [Cosonic Intelligent Technologies Co.,Ltd.] for FCC ID: [2ALVK-HANP1T]. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: [Cosonic Intelligent Technologies Co.,Ltd.] Designated Agent: FCC US Agent, LLC Company Representative: [Nick Yu] Designated Agent Representative: Tim Payne Signature: Signature:

Cover Letter(s)

RF_160, Issue 03 Declaration of Authorization We Name: Cosonic Intelligent Technologies Co.,Ltd. Address: NO.3 Keyuan Road,Songshan Lake District, Dongguan City, Guangdong, China City: Guangdong State or Country: China Declare that: Name Representative of agent: Lisa Wang (1) Agent Company name: EMTEK (SHENZHEN) CO., LTD. Address: Bldg 69, Majialong Industry Zone, Nanshan District, City: Shenzhen Country China is authorized to apply for Certification of the following product(s): Product description: WIRELESS HEADPHONES Type designation: HA-NP1T Trademark: JVC FCC ID: 2ALVK-HANP1T on our behalf. Date: 2024-7-31 Name: Nick Yu Function: Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Cosonic Intelligent Technologies Co.,Ltd. Address : NO.3 Keyuan Road,Songshan Lake District, Dongguan City, Guangdong, China City: Guangdong Country: China To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: 2ALVK-HANP1T Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: The product is not on the market yet Planned Release Date STC: 180Days (notes 2, 3, 4, 5) Date: 2024-7-31 Name and signature of applicant: Nick Yu Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

RF Exposure Info

Report No. ENS2406250174W01405R Page 1 of 35 Ver.1.0 TEST REPORT Product Name : WIRELESS HEADPHONES Model Number : HA-NP1T FCC ID : 2ALVK-HANP1T Prepared for : Cosonic Intelligent Technologies Co., Ltd. Address : NO.3 Keyuan Road,Songshan Lake District, Dongguan City, Guangdong Province 523808 Prepared by : EMTEK (SHENZHEN) CO., LTD. Address : Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guan gdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Numbe r : ENS2406250174W01405R Date(s) of Tests : July 8, 2024 to July 8, 2024 Date of Issue : Jul y 9, 2024 $二维码$ Report No. ENS2406250174W01405R Page 2 of 35 Ver.1.0 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ............................................................................................................................ 4 2. Description of Equipment Under Test .................................................................................................................. 6 3. SAR Measurement System .................................................................................................................................... 7 3.1 Definition of Specific Absorption Rate (SAR) ................................................................................................... 7 3.2 SPEAG DASY System ..................................................................................................................................... 7 3.2.1 Robot .................................................................................................................................................. 8 3.2.2 Probes ................................................................................................................................................ 9 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................... 9 3.2.4 Phantoms ......................................................................................................................................... 10 3.2.5 Device Holder ................................................................................................................................... 11 3.2.6 System Validation Dipoles ................................................................................................................ 11 3.2.7 Tissue Simulating Liquids ................................................................................................................. 12 3.3 SAR System Verification ................................................................................................................................ 14 3.4 SAR Measurement Procedure ....................................................................................................................... 15 3.4.1 Area & Zoom Scan Procedure ......................................................................................................... 15 3.4.2 VolumeScan Procedure .................................................................................................................... 15 3.4.3 Power Drift Monitoring ...................................................................................................................... 16 3.4.4 Spatial Peak SAR Evaluation ........................................................................................................... 16 3.4.5 SAR Averaged Methods ................................................................................................................... 16 4. SARMeasurement Evaluation .............................................................................................................................. 17 4.1 Applicable Standards ..................................................................................................................................... 17 4.2 EUT Testing Position ...................................................................................................................................... 17 4.2.1 Head&Body Exposure Conditions .................................................................................................... 17 4.2.1 SAR Test Exclusion Evaluations ...................................................................................................... 19 4.3 Tissue Verification .......................................................................................................................................... 20 4.4 System Validation ........................................................................................................................................... 20 4.5 System Verification ......................................................................................................................................... 21 4.6 Maximum Output Power ................................................................................................................................. 22 4.6.1 Maximum Conducted Power ............................................................................................................ 22 4.6.2 Measured Conducted Power Result ........................................................................................ ........ 23 4.7 SAR Testing Results ....................................................................................................................................... 24 4.7.1 SAR Test Reduction Considerations ................................................................................................ 24 4.7.2 SAR Results for Head Exposure Condition ...................................................................................... 24 4.7.3 Estimated SAR Calculation .............................................................................................................. 25 5. Calibration of Test Equipment ........................................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

. Test Laboratory: Shenzhen EMTEK Co.,Ltd.Date: 2024/7/8 System Check_H2450 DUT: Dipole 2450 MHz; Type:D2450V2; SN:927 Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: H2450 Medium parameters used: f = 2450 MHz;σ=1.78S/m;ε r =40.11;ρ=1000kg/m 3 AmbientTemperature:22.0°C; LiquidTemperature:21.8°C DASY5 Configuration: - Probe: EX3DV4 - SN3970; Calibrated: 2024/6/25; - Electronics: DAE4 Sn1418; Calibrated: 2024/5/17 - Phantom: Left Phantom with CRP v5.0; Type: QD000P40CD; Serial: TP:1722 - Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164) Pin=250mW/Area Scan (41x51x1):Interpolated grid: dx=2.000 mm, dy=2.000 mm Maximum value of SAR (interpolated) = 25.2 W/kg Pin=250mW/Zoom Scan (5x5x7)/Cube 0:Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 115.7 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 31.7 W/kg SAR(1 g) = 13.07 W/kg; SAR(10 g) = 6.12 W/kg Maximum value of SAR (measured) = 21.3 W/kg

RF Exposure Info

Test Laboratory: Shenzhen EMTEK Co.,Ltd.Date: 2024/7/8 BT DUT:HA-NP1T Communication System: BT; Frequency: 2480 MHz;Duty Cycle: 1:1.3020 Medium: H2450 Medium parameters used: f = 2480 MHz;σ=1.78S/m;ε r =40.05;ρ=1000kg/m 3 AmbientTemperature:22.0°C; LiquidTemperature:21.8°C DASY5 Configuration: - Probe: EX3DV4 - SN3970; Calibrated: 2024/6/25; - Electronics: DAE4 Sn1418; Calibrated: 2024/5/17 - Phantom: SAM; Type: QD000P40CD; Serial: TP:1794 - Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164) Left Head/Front-DH5/Area Scan (6x7x1):Measurement grid: dx=20mm, dy=20mm Maximum value of SAR (measured) = 0.0245 W/kg Left Head/Front-DH5/Zoom Scan (5x5x7)/Cube 0:Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.792 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.210 W/kg SAR(1 g) = 0.012 W/kg; SAR(10 g) = 0.00481 W/kg Maximum value of SAR (measured) = 0.026 W/kg Test Laboratory: Shenzhen EMTEK Co.,Ltd.Date: 2024/7/8 BT DUT: HA-NP1T Communication System:BT; Frequency: 2480 MHz;Duty Cycle: 1:1.3020 Medium: H2450 Medium parameters used: f = 2480 MHz;σ=1.78S/m;ε r =40.05;ρ=1000kg/m 3 AmbientTemperature:22.0°C; LiquidTemperature:21.8°C DASY5 Configuration: - Probe: EX3DV4 - SN3970; Calibrated: 2024/6/25; - Electronics: DAE4 Sn1418; Calibrated: 2024/5/17 - Phantom: SAM; Type: QD000P40CD; Serial: TP:1794 - Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164) Front-3DH5/Area Scan (7x7x1):Measurement grid: dx=20mm, dy=20mm Maximum value of SAR (measured) = 0.0088 W/kg Front-3DH5/Zoom Scan (5x5x7)/Cube 0:Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.741 V/m; Power Drift = 0.16 dB Peak SAR (extrapolated) = 0.0410 W/kg SAR(1 g) = 0.019 W/kg; SAR(10 g) = 0.00921 W/kg Maximum value of SAR (measured) = 0.015 W/kg

Test Report

1 Antenna Part Specification Customers: Cosonic Intelligent Technologies Co.,Ltd. Project name: CE-2202B Antenna type: L-FPC Antenna Antenna model: SX230910-151E Antenna morphology: PIFA Version: V1.0 Date: 2024.06.25 Manufacturer: Shenzhen Cicent Communication Technology Co., Ltd. Manufacturer Address: 505-506 ,ABlock,Donglian Building,Chuangye 2 road,Baoan District,Shenzhen,Guangdong,P.R china 2 Contents I: The report of passive data ...................................................................................................... 3 II:3D Active test report of antenna ...................................................................................... 6 III:Matching circuit ................................................................................................................ 7 IV:Assembly precautions ....................................................................................................... 7 V:Structure file ....................................................................................................................... 9 Change record Compile / change date Reason for change Changed content Version 2024.06.25 First edition First edition V1.0 3 I: The report of passive data Angilent E5071C S11 parameter: 4 Efficiency: L Frequency (MHz) Efficiency Efficiency (dB ) Gain (dBi) 2400 22.1% -6.57 -0.91 2410 21.9% -6.60 -0.89 2420 21.2% -6.75 -0.98 2430 21.5% -6.67 -0.96 2440 20.8% -6.82 -1.10 2450 21.6% -6.66 -1.03 2460 21.6% -6.66 -1.23 2470 19.7% -7.06 -1.71 2480 18.5% -7.33 -2.07 Average value 21.0% -6.79 -1.21 3D Antenna radiation pattern: 5 Antenna radiation pattern: Theta=90.00deg Phi=0.00deg Phi=90.00deg 6 II:3D Active test report of antenna Free space Channel TRP(dBm) TIS(dBm) L CH 0 1.6 -87.7 CH 39 3.1 -88.5 CH 78 2.8 -88.9 Headform Channel TRP(dBm) TIS(dBm) L CH 0 0.9 -86.7 CH 39 1.9 -87.6 CH 78 1.7 -88.0 OTA Standard Chamber 7 III:Matching circuit Element Value E1(0201) N/A E2(0201) 0Ω E3(0201) N/A IV:Assembly precautions 1.As shown in the above figure, after welding the speaker wire and battery wire, they need to be bent towards the direction of the board and the wire should not be extended beyond the projection of the board (also pay attention to the wire position during assembly), the left and right ears are the same! 8 2. As shown in the above figure, the length of the speaker wire and battery wire has not been modified. The battery wire is evenly twisted (can be twisted 2-3 times), and the speaker wire is not processed. The two sets of wires need to be placed separately. The excess part of the battery wire and speaker wire should be placed at the edge of the shell (marked in red circle), and do not put too many speaker wires and battery wires into the wire slot! The left and right ears are the same. 3. As shown in the above figure, stick EV cotton near the speaker line of the battery to fix the speaker line, the left and right ears are the same! 4. As shown in Note 1 of the above figure, the size of the foam plug at the cable slot, the position of the plug, and the degree of downward pressure need to be consistent, otherwise there is a risk of frequency deviation consistency, just like the left and right ears! 5. As shown in Note 2 of the above figure, after pressing the speaker wire to the bottom, fix it with glue, and the left and right ears are the same! 9 V:Structure file

Test Report

Report No. ENS2406250174W01401R Page 1 of 70 Ver.1.0 TEST REPORT Product Name :WIRELESS HEADPHONES Model Number : HA-NP1T FCC ID :2ALVK-HANP1T Prepared for : Cosonic Intelligent Technologies Co., Ltd. Address : NO.3 Keyuan Road,Songshan Lake District, Dongguan Cit y, Guangdong Province 523808 Prepared b y : EMTEK (SHENZHEN) CO., LTD. Address : Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guan gdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Numbe r : ENS2406250174W01401R Date (s) of Tests : June 25, 2024 to July 15, 2024 Date of Issue : July 15, 2024 $二维码$ Report No. ENS2406250174W01401R Page 2 of 70 Ver.1.0 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ....................................................................................................... 3 2 EUT TECHNICAL DESCRIPTION ...................................................................................................... 5 3 SUMMARY OF TEST RESULT .......................................................................................................... 6 4 TEST METHODOLOGY ..................................................................................................................... 7 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 7 4.2 MEASUREMENT EQUIPMENT USED ....................................................................................... 7 4.3 DESCRIPTION OF TEST MODES ............................................................................................. 8 5 FACILITIES AND ACCREDITATIONS ................................................................................................ 9 5.1 FACILITIES ................................................................................................................................. 9 5.2 LABORATORY ACCREDITATIONS AND LISTINGS .................................................................. 9 6 TEST SYSTEM UNCERTAINTY ...................................................................................................... 10 7 SETUP OF EQUIPMENT UNDER TEST ......................................................................................... 11 7.1 RADIO FREQUENCY TEST SETUP 1 ...................................................................................... 11 7.2 RADIO FREQUENCY TEST SETUP 2 ...................................................................................... 11 7.3 CONDUCTED EMISSION TEST SETUP ................................................................................. 13 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ..................................................... 14 7.5 SUPPORT EQUIPMENT .......................................................................................................... 14 8 FREQUENCY HOPPING SYSTEM REQUIREMENTS ................................................................... 15 8.1 STANDARD APPLICABLE ........................................................................................................ 15 8.2 EUT PSEUDORANDOM FREQUENCY HOPPING SEQUENCE ............................................ 15 8.3 EQUAL HOPPING FREQUENCY USE .................................................................................... 16 8.4 FREQUENCY HOPPING SYSTEM .......................................................................................... 16 9 TEST REQUIREMENTS ................................................................................................................... 17 9.1 20DB BANDWIDTH .................................................................................................................. 17 9.2 CARRIER FREQUENCY SEPARATION ................................................................................... 21 9.3 NUMBER OF HOPPING FREQUENCIES ................................................................................ 25 9.4 AVERAGE TIME OF OCCUPANCY (DWELL TIME) ................................................................ 27 9.5 MAXIMUM PEAK CONDUCTED OUTPUT POWER................................................................ 29 9.6 CONDUCTED SUPRIOUS EMISSION ..................................................................................... 33 9.7 RADIATED SPURIOUS EMISSION .......................................................................................... 50 9.8 CONDUCTED EMISSION TEST .............................................................................................. 64 9.9 ANTENNA APPLICATION ......................................................................................................... 67 10 APPENDIX PHOTOGRAPHS OF EUT ................................ ............................................................ 69 11 APPENDIX PHOTOGRAPHS OF TEST SETUP ............................................................................. 70 Report No. ENS2406250174W01401R Page 3 of 70 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant : Cosonic Intelligent Technologies Co., Ltd. Address : NO.3 Keyuan Road,Songshan Lake District, Dongguan City, Guangdong Province 523808 Manufacturer : Cosonic Intelligent Technologies Co., Ltd. Address : NO.3 Keyuan Road,Songshan Lake District, Dongguan City, Guangdong Province 523808 EUT : WIRELESS HEADPHONES Model Name : HA-NP1T Trademark : JVC Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C PASS The above equipment was tested by EMTEK (SHENZHEN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2 and Part 15.247 The test results of this report relate only to the tested sample identified in this report. Date of Test : June 25, 2024 to Jul y 15, 2024 Prepared b y : Una Yu/Editor R…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nick Yu
[email protected]0769-86596999Fax: 0769-86596111

Technical Contact

EMTEK (SHENZHEN) CO., LTD.David Lee
[email protected]86 755 26504659

Bldg 69,Majialong Industry Zone,Nanshan · China

Non-Technical Contact

Cosonic Intelligent Technologies Co.,Ltd.KAI YAN
[email protected]0769-86596919

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]8675526954280

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.40 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR for head exposure condition is <0.10 W/kg.

Other Applications from Cosonic Intelligent Technologies Co.,Ltd.

2ALVK-HANP3T

WIRELESS HEADPHONES

Aug 21, 2026

Equipment Class

DTS - Digital Transmission System
2ALVK-ONN100094794

Wireless Bone Conduction Headphones

Aug 21, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ALVK-ONN36017613

Wireless earphones

Apr 21, 2026

Equipment Class

DTS - Digital Transmission System
2ALVK-ONN36020845

ONN PRO TWS ANC

Apr 09, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ALVK-ONN36020834

ONN Mini sticks

Feb 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter