
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Overview Thank you for purchasing this portable digital video camera, this camera features video recording at 4K. With resolution of 3840*2160, it adopted 1/3-inch image sensor,the video file storage usage is small while it has high image quality! You can connect your camera via Wi-Fi using your smart Phone remotely, to view the camera live screen and use your phone to record or shooting. Safety Instructions Do not drop, impact or puncture the camera Do not expose the camera to high/low temperature, excessive dust, humidity or strong vibration, otherwise the product may be damaged. Do not use corrosive chemicals or solvents to clean the product. Do not disassemble this camera or attempt to repair or modify it in any manner. Cautions Keep children away from the product, accessories and its packaging materials, it may cause suffocation. Do not put the product in a fire, otherwise it may cause an explosion. Remove the battery if the camera is not going to be used for long periods, and please fully-charged the battery before using it again. Table Of Contents Getting to Know Your Camera ................................................ 1 Standard Accessories ................................................... 1 Charging the Battery ..................................................... 1 Component Introduction ............................................... 3 Getting Started....................................................................... 7 Inserting an SD Card .................................................... 7 Loading Battery ............................................................ 8 Recording Mode ........................................................... 9 Photo Mode ................................................................ 12 Set Mode .................................................................... 18 Playback ..................................................................... 20 Connecting to TV ........................................................ 23 Connecting to the Computer ....................................... 24 APP Using ........................................................................... 25 APP Downloading ..................................................... 25 APP Connecting ....................................................... 25 APP Functions ............................................................ 27 Technical Parameters .......................................................... 30 Troubleshooting ................................................................... 32 1 Getting to Know Your Camera Standard Accessories 4K Ultra HD Camera Infrared remote control Battery HDMI Cable Charger User Manual USB Cable DV Pouch The above are all accessories, if there is any missing, please contact the seller for replacement. Charging the Battery Before using the camera, you must load and charge the battery Charging with the Charger Connect to 100-220V socket Note:Insert the battery into the charger to charge it, the indicator light will be red when charging; The indicator light will turn green when the charging is completed. 2 Charging with USB Cable (Direct Charge) 1.Please Connect the USB Cable to the charging adapter when camera is running low. 2.Connect the other side to the Camera’s USB charging interface. 3.The indicator light will be red when charging; The indicator light will turn green when the charging is completed. Note: 1.When using the charger, please install the battery in the charger slot correctly. 2.For direct charge, please use the 5V/2A-2.5A charging adapter for charging. 3.When using the USB Cable to charge, if charge during working condition, the camera will automatically shut down after the charging adapter is powered off. 3 Component Introduction A For the function description of the related parts in the above figure, please refer to the following table. No. Name Function description ① IPS Touch Panel Screen preview and video/photo playback. ② Hot shoe interface Mount hot shoe products. ③ Horn Plays back sounds. ④ DISP Button Press to switch screen display Mode. ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑯ ⑰ ⑱ ⑲ ⑭ ② ③ ① ④ ⑦ ⑮ ⑤ ⑥ 4 ⑤ T/W Zoom Button In video/Photo Mode, pull left/ right to zoom in/out; In Playback Mode, pull to switch photos/videos; In Menu, pull to menu selection. In Video Playback, pull to adjust the volume. ⑥ Photo Button Two-stage button, tap to focus and press to photo in photo mode. ⑦ Power indicator Always on after power on. ⑧ Power Button Power On/Off. ⑨ State Light Display of mode status. ⑩ Mode Button Press to enter the mode menu while in photo / video / playback mode. ⑪ Video Button 1.Recording/stop video. 2.Stop playback when the video is Playing. ⑫ I/O Interface 10PIN USB interface:Access the USB Cable to charge; HDMI:External HD Cable to connect to TV; MIC:Access to an external microphone. ⑬ Built-in microphone Recording sound. ⑭ Up Button/IR Night Vision Switch When entering the menu, press to move the cursor upward; when in 5 the photo / recording mode, press to turn on / off the IR Light.. ⑮ Down Button/“Delete” Shortcut When entering the menu, press and move the cursor down;Press to delete recent videos or photos. ⑯ Right Button/Increased exposure When entering the menu, press and move the cursor to the right;In photo / video mode, press exposure to increase the exposure value. ⑰ Left Button/Reduce exposure When entering the menu, press and move the cursor to the left; In photo / video mode, press exposure to decrease the exposure value. ⑱ Confirm Button After entering the menu to select the function option, press to confirm the selection. ⑲ Menu Button Press to enter the Menu. B ① ② ③ 6 For the function description of the related parts in the above figure, please refer to the following table. No. Name Function description ① Lens Framing ② Infrared remote-control receiver Receiving remote command ③ IR Light Lighting assist C For the function description of the related parts in the above figure, please r…
Text truncated - open the document above for the full version.
Page 1 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 8 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15
Page 1 of 1 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L4.0cm x 3.0cm) Label Location Camcorder Model: HDR-AX10 FCC ID: 2ALYUHDR-AX10
Page 1 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Wifi Antenna
Page 1 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID 2ALYUHDR-AX10 Product name Camcorder Test Model HDR-AX10 Additional Model No. HDV-PX10, HDV-PX20, HDV-PX50, HDV-PX55, HDV-PX33, HDV-A11ES, HDR-A30E, LM-AX10, Ordro AX10, SL-AX10-SET4, EUBY-AX10, BOYA-AX10, ORDRO-AX10, US-AX10, US-AX10-TOP, US-AX10-Kit, Ordro AX10, Ordro AX10 Combo, Ordro AX10 LED, Ordro AX10 JP, MN4K30NV, HDR-A10P Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Modulation Type IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Type Ceramic Antenna Antenna Gain -2.08dBi (max.) Hardware version V1.0 Software version V1.0 FCC Operation frequency 2412MHz ~ 2462MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable Device Page 2 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a)The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 4 FCC ID: 2ALYUHDR-AX10 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power <2.4G WIFI> Mode Channel Frequency(MHz) Max Conducted Power (dBm) IEEE 802.11b 1 24…
Text truncated - open the document above for the full version.
DV937KCTest Report *本报告属于深圳市杰迅通无线技术有限公司与相关客户机密存档,请妥善保管,未经许可,不得外泄。 Test Item and Equipment System Test Item Test ParametersTest Equipment 1、S parametersVSWR;Smith; Network analyzer: Agilent 5071B 2、Passive test Efficiency, gain test Comprehensive analyzer: Network analyzer: Agilent 5071B Microwave anechoic chamber: GTS 2800 Key terms: : VSWR:VSWR: As the abbreviation of voltage standing wave ratio, it refers to the ratio of back wave amplitude to incident wave amplitude. If the impedance is completely matching in ideal conditions, the value of VSWR is 1. In actual engineering, reflection does exist, and the value of VSWR is larger than 1. The larger the reflection is, the larger the VSWR will be. As for the technical parameter VSWR, it is better if the number is lower and approximate to 1. Return Loss:Return Loss: RL refers to the ratio of the power reflected by RF input signals to the power of input signals. The unit is dB, and it is a negative number. In ideal conditions, the antenna is completely matching with the impedance of RF circuit and it has no reflection power completely, and the return loss at the moment is infinitely small. In actual engineering, the impedance cannot be matching completely, so reflection power does exist. The worst condition is that the input power is reflected completely, and the return loss at the moment is 0. As for the technical parameter return loss, the antenna performance is better if the value is lower. Effi:Effi: Efficiency refers to the ratio of the power from antenna radiation (i.e. effectively converting electromagnetic wave power) and the power input to antenna. It is a number constantly lower than 100%. Gain:Antenna gain refers to the ratio of power density of signals generated by actual antenna and ideal radiating elements in the same spatial spot in equivalent input power. It quantificationallydescribes the extent of centralized radiation by an antenna for input power. Generally, the unit is dBi. 。 Smith图:The impedance circle diagram refers to a trajectory chart of presenting normalization impedance on the reflection coefficient complex plane by using the one-to-one correspondence between normalization impedance and reflection coefficients. TRP:Total radiated power refers to the integral value of surface integral (average value of spherical surface) of the mobile station for equivalent isotropicallyradiated power (EIRP) in 3D space. It reflects the transmission characteristics of the mobile station in all directions. TIS:TIS: Total isotropic sensitivity refers to the integral value of surface integral (average value of spherical surface) of themobile station for effective isotropic sensitivity (EIS) in 3D space. It reflects the reception characteristics of the mobile station in alldirections. 1 Schematic diagram of whole machine Schematic diagram of whole machine Schematic diagram of antenna placement ANT 2 Matching description E1E2E3E4 NANA NA NA RF Antenna ≡ E1E3 E2 ≡ E4 Description: The original matching is not modified for the testing。 3 VSWR 4 Effi/Gain 5 Field Pattern Diagram 2400MHz 2450MHz 2500MHz 6 Summary: Summary: : 1. The above contents are the passive test report for DV937KC; 2. The prototype status and parameters are not modified for the testing. The above contents are for your evaluation and consideration. Please feel free to contact us if you have any questions. Thanks! ! THANkSFORYOU
Page 1 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Camcorder Test Model: HDR-AX10 Environmental Conditions Temperature: 23.5 C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Wunder Wu Supervised by: Li huan Page 2 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 6.303 >=0.5 Pass NVNT b 2437 Ant1 8.56 >=0.5 Pass NVNT b 2462 Ant1 7.097 >=0.5 Pass NVNT g 2412 Ant1 14.841 >=0.5 Pass NVNT g 2437 Ant1 16.329 >=0.5 Pass NVNT g 2462 Ant1 15.802 >=0.5 Pass NVNT n20 2412 Ant1 15.319 >=0.5 Pass NVNT n20 2437 Ant1 17.558 >=0.5 Pass NVNT n20 2462 Ant1 16.941 >=0.5 Pass NVNT n40 2422 Ant1 29.004 >=0.5 Pass NVNT n40 2437 Ant1 36.322 >=0.5 Pass NVNT n40 2452 Ant1 36.274 >=0.5 Pass Page 3 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Page 4 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Page 5 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Page 6 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 Page 7 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant1 -6dB Bandwidth NVNT n40 2422MHz Ant1 Page 8 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n40 2437MHz Ant1 -6dB Bandwidth NVNT n40 2452MHz Ant1 Page 9 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 5.38 0 5.38 30 Pass NVNT b 2437 Ant1 6.32 0 6.32 30 Pass NVNT b 2462 Ant1 6.05 0 6.05 30 Pass NVNT g 2412 Ant1 5.78 0 5.78 30 Pass NVNT g 2437 Ant1 6.63 0 6.63 30 Pass NVNT g 2462 Ant1 6.34 0 6.34 30 Pass NVNT n20 2412 Ant1 5.74 0 5.74 30 Pass NVNT n20 2437 Ant1 6.52 0 6.52 30 Pass NVNT n20 2462 Ant1 5.67 0 5.67 30 Pass NVNT n40 2422 Ant1 6.21 0 6.21 30 Pass NVNT n40 2437 Ant1 6.23 0 6.23 30 Pass NVNT n40 2452 Ant1 6.1 0 6.1 30 Pass Page 10 of 55 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 Ant1 -17.98 0 -17.98 8 Pass NVNT b 2437 Ant1 -16.86 0 -16.86 8 Pass NVNT b 2462 Ant1 -17.13 0 -17.13 8 Pass NVNT g 2412 Ant1 -21.85 0 -21.85 8 Pass NVNT g 2437 Ant1 -21.08 0 -21.08 8 Pass NVNT g 2462 Ant1 -18.16 0 -18.16 8 Pass NVNT n20 2412 Ant1 -21.46 0 -21.46 8 Pass NVNT n20 2437 Ant1 -20.23 0 -20.23 8 Pass NVNT n20 2462 Ant1 -17.86 0 -17.86 8 Pass NVNT n40 2422 Ant1 -17.85 0 -17.85 8 Pass NVNT n40 2437 Ant1 -20.08 0 -20.08 8 Pass NVNT n40…
Text truncated - open the document above for the full version.
Page 1 of 37 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Shenzhen PA. Times Technology Co., Ltd Camcorder Test Model: HDR-AX10 Additional Model No.: Please Refer to Page 6 Prepared for : Shenzhen PA. Times Technology Co., Ltd Address : Room D-E, Floor 14, Block B, Xuesong Building, Tairan Road 6, Tairan Science & Technology Park, Futian District, Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : July 22, 2022 Number of tested samples : 2 Sample number : A072122079-1, A072122079-2 Serial number : Prototype Date of Test : July 22, 2022 ~ July 28, 2022 Date of Report : July 28, 2022 Page 2 of 37 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA072122079EA Date of Issue .................................. : July 28, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Shenzhen PA. Times Technology Co., Ltd Address .......................................... : Room D-E, Floor 14, Block B, Xuesong Building, Tairan Road 6, Tairan Science & Technology Park, Futian District, Shenzhen, China Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. .................. : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Camcorder Trade Mark ..................................... : Test Model ...................................... : HDR-AX10 Ratings ........................................... : Input: 5V1A DC 3.7V by Rechargeable Li-ion Battery, 1300mAh 4.81Wh Result ............................................ : Positive Compiled by: Supervised by: Approved by: Wunder Wu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 37 FCC ID: 2ALYUHDR-AX10 Report No.: LCSA072122079EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC --…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 4.20 mW |

Optical Zoom Camcorder
Equipment Class
DTS - Digital Transmission System
HANDHELD CAMERA
Equipment Class
DTS - Digital Transmission SystemCamcorder
Equipment Class
DTS - Digital Transmission System
4K OPTICAL VIDEO CAMERA
Equipment Class
DTS - Digital Transmission System
POCKET CAMERA
Equipment Class
DTS - Digital Transmission System