T-Coil Signal Test Report Measurement performed on March 13, 2026at11:58 DeviceUnderTest Manufacturer Model Dimensions [mm] Speaker Position [mm] 146.2x71.8x7.5 144.3 Hardware Setup ProbeName Probe Calibration Date AM1DV3-3115 October 01, 2025 DAE Name DAE Calibration Date DAE3 Sn528 May 12, 2025 Communication Systems Band Name Communication Systems Name Channel Frequency [MHz] Band n2 5G NR (DFT-s-OFDM, 1 RB, 20 MHz, QPSK, 15 kHz) 376000 1880.0 Grid Settings Extent X [mm] Extent Y [mm] Step X [mm] Step Y [mm] Distance [mm] 52.052.04.04.010.0 Results AudioFile Measurement Duration [s] Margin Upper Bound [dB] Margin Lower Bound [dB] 48kvoice 300-3000 2s.wav2.00.81 2.0 T-Coil Signal Test Report Measurement performed on March 13, 2026at10:12 DeviceUnderTest Manufacturer Model Dimensions [mm] Speaker Position [mm] 146.2x71.8x7.5 144.3 Hardware Setup ProbeName Probe Calibration Date AM1DV3-3115 October 01, 2025 DAE Name DAE Calibration Date DAE3 Sn528 May 12, 2025 Communication Systems Band Name Communication Systems Name Channel Frequency [MHz] Band n41 5G NR (DFT-s-OFDM, 1 RB, 100 MHz, QPSK, 30 kHz) 5185982592.99 Grid Settings Extent X [mm] Extent Y [mm] Step X [mm] Step Y [mm] Distance [mm] 52.052.04.04.010.0 Results AudioFile Measurement Duration [s] Margin Upper Bound [dB] Margin Lower Bound [dB] 48kvoice 300-3000 2s.wav2.0 0.992.0 T-Coil Coupling ModeTest Report Results Primary Group Contiguous Point Count 270 Secondary Group Point Count 512 Secondary Group Max Longitudinal 26 Secondary Group Max Transverse 26 T-Coil Signal Test Report Measurement performed on March 12, 2026at 19:39 DeviceUnderTest Manufacturer Model Dimensions [mm] Speaker Position [mm] 146.2x71.8x7.5 144.3 Hardware Setup ProbeName Probe Calibration Date AM1DV3-3115 October 01, 2025 DAE Name DAE Calibration Date DAE3 Sn528 May 12, 2025 Communication Systems BandName Communication Systems Name Channel Frequency [MHz] Band 2, E-UTRA/FDD LTE-FDD (SC-FDMA, 1 RB, 20 MHz, QPSK) 189001880.0 Grid Settings Extent X [mm] Extent Y [mm] Step X [mm] Step Y [mm] Distance [mm] 52.052.04.04.010.0 Results AudioFile Measurement Duration [s] Margin Upper Bound [dB] Margin LowerBound [dB] 48k voice 300-3000 2s.wav2.00.7 2.0 T-Coil Signal Test Report Measurement performed on March 12, 2026at18:59 DeviceUnderTest Manufacturer Model Dimensions [mm] Speaker Position [mm] 146.2x71.8x7.5 144.3 Hardware Setup ProbeName Probe Calibration Date AM1DV3-3115 October 01, 2025 DAE Name DAE Calibration Date DAE3 Sn528 May 12, 2025 Communication Systems BandName Communication Systems Name Channel Frequency [MHz] Band 41, E-UTRA/TDD LTE-TDD (SC-FDMA, 1 RB, 20 MHz, QPSK) 40620 2593.0 Grid Settings Extent X [mm] Extent Y [mm] Step X [mm] Step Y [mm] Distance [mm] 52.052.04.04.010.0 Results AudioFile Measurement Duration [s] Margin Upper Bound [dB] Margin LowerBound [dB] 48k voice 300-3000 2s.wav2.01.02 2.0
TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 46 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China HACT-CoilTestReport For ApplicantName:Schok,LLC. Address:5850TownandCountryBlvd,Suite203|Frisco,TX75034 EUTName:5GSmartphone BrandName:Schok ModelNumber:SchokVoltSV69S IssuedBy CompanyName: BTFTestingLab(Shenzhen)Co.,Ltd. Address: 101/201/301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangSubdistrict,Bao'anDistrict, Shenzhen,China ReportNumber: BTF250926R00102 TestStandards: ANSIC63.19-2019FCC47CFR§20.19KDB285076D01 KDB285076D02KDB285076D03 FCCID: 2AM9L-SV69S TestConclusion: Pass TestDate: 2025-11-20to2026-03-11 DateofIssue: 2026-03-16 ReviewedBy: AmendaZhong/ProjectEngineer Date: 2026-03-16 ApprovedBy: Ryan.CJ/EMCManager Date: 2026-03-16 Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. TestReportNumber:BTF250926R00102 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 46 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China RevisionHistory VersionIssueDateRevisionsContent R_V02025-12-08Original R_V02026-03-16TheVOIPtestdatahasbeenupdatedbased ontheoriginalreport.Detailscanbefoundin Section8ofthereport.Thisdatacomesfrom TOWEWirelessTesting(Shenzhen)Co.,Ltd. Note:Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. TestReportNumber:BTF250926R00102 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 46 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China TableofContents 1.Introduction...............................................................................................................................................................................4 1.1IdentificationofTestingLaboratory.................................................................................................................................4 1.2IdentificationoftheResponsibleTestingLocation..........................................................................................................4 1.3LaboratoryCondition.......................................................................................................................................................4 1.4Announcement................................................................................................................................................................4 2.ProductInformation..................................................................................................................................................................5 2.1ApplicationInformation....................................................................................................................................................5 2.2ManufacturerInformation................................................................................................................................................5 2.3FactoryInformation.........................................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT).....................................................................................................5 2.5EquipmentunderTestAncillaryEquipment....................................................................................................................5 2.6TechnicalInformation......................................................................................................................................................5 2.7EquipmentunderTest(EUT)Description.......................................................................................................................6 2.8AirInterfaces/BandsIndicatingOperatingModes.........................................................................................................7 3.SummaryofTestResults.........................................................................................................................................................8 3.1TestStandards................................................................................................................................................................8 3.2AttestationofTestingSummary......................................................................................................................................8 4.TestUncertainty........................................................................................................................................................................9 5.MeasurementSystem.............................................................................................................................................................10 5.1DefinitionofHearingAidCompatibility(HAC)...............................................................................................................10 5.2MVGHACSystem.........................................................................................................................................................11 5.3T-CoilMeasurementSet-up..........................................................................................................................................14 5.4SystemCalibration................................................................................................................…
Text truncated - open the document above for the full version.
校 准 证 书 CALIBRATION CERTIFICATE 证书编号: JL2501133081 批准人 : Approved by 张瑞纹 (校准专用章) Stamp 签名 : Signature 校准日期 : Operation Date 2025 年 02 月 11 日 Year Month Day 核验员 : Checked by 建议复校日期: Suggested Recal.Date ---- 年 -- 月 -- 日 Year Month Day 校准员 : Calibrated by 签发日期 : Issue Date 2025 年 02 月 11 日 Year Month Day 证书首页背面“重要声明”是证书的组成部分,任何未包含“重要声明”内容的复制均为不完整复制。 深圳市计量质量检测研究院 地址:广东省深圳市南山区龙珠大道 92 号 客户服务热线:400 900 8999 – 1 邮编:518055 网址: www.smq.com.cn 电子邮件:[email protected] Shenzhen Academy of Metrology & Quality Inspection Add:No.92,Longzhu Avenue, NanShan District, Shenzhen. Customer Service Hotline:400 900 8999 - 1 Post Code: 518055 http://www.smq.com.cn Email:[email protected] 客户名称 : Name of Customer 信恒检测技术(深圳)有限公司 BTF Testing Lab (Shenzhen) Co., Ltd. 客户地址 : Address of Customer 广东省深圳市宝安区松岗街道潭头社区潭头工业城二区 1 栋厂房 101、201、301 F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China 计量器具名称 : Name of Instrument Head and Torso Simulator 头部躯干模拟器 型号/规格 : Type/Specification Type 4128C 出厂编号 : Serial No 3107080 资产编号 : Asset No BTF-EM-148 制造单位 : Manufacture B&K 校准依据 : Calibrated in Accordance to JJF1520-2015 声学用头和躯干模拟器校准规范 第 1 页,共 11 页 Page 1 of 11 Pages 重 要 声 明 Important statement 1.本院(站)是由深圳市人民政府依据《中华人民共和国计量法》设置并由国家市场监督管理总局、广东省市场监督管理局依法授权的法定计量检定机构。 SMQ is a legal metrological verification organization established by the Shenzhen Municipal People's Government and authorized by the State Administration for Market Regulation and Guangdong Administration for Market Regulation according to the Law on Metrology of the People's Republic of China. 2.本院(站)进行的检定、校准和检测均可溯源至国际单位制(SI)单位和社会公用计量标准。 All verifications, calibrations and tests made by SMQ are traceable to the International System of Units (SI) and social public measurement standards. 3.未经本院(站)许可,不得部分复印、摘用或篡改本证书/报告的内容;复印证书/报告未重新加盖本院证书/报告专用章无效。 Copying or excerpting portion of, or altering the content of the certificate/report is not permitted without the written authorization of SMQ.Any copy of certificates/reports without the Dedicated certificate/report Seal is deemed to be invalid. 4.如果要满足被校准仪器的技术指标,或者技术法规要求,在规定范围内适用,请在建议复校日期前校准(适用于校准报告)。 To ensure that the calibrated object is properly used under given conditions in compliance with technical specifications or regulations, recalibrate before the suggested date (Applicable to calibration report only). 5.本证书/报告提供的结果仅对本次被检的计量器具有效。 The results provided by the certificate/report are only valid for the measuring object under test this time. 6.证书/报告无检定员/校准员、核验员、批准人签字,或涂改,或未盖本院证书/报告专用章及骑缝章无效。 Any certificate/report having not been signed by relevant responsible engineer, reviewer or authorized approver, or having been altered without authorization, or without both the Dedicated certificate/report Seal and its across-page seal is deemed to be invalid. 7.证书/报告更改后,发出的电子版证书/报告、证书/报告的扫描件及传真件将不被追回,委托方有义务将更改后的证书/报告提供给使用原证书/报告的相关方。 SMQ is not responsible for recalling the electronic version of the original certificate/report when any revision is made to them. The applicant assumes the responsibility of providing the revised version to any interested party who uses them. 8.申领电子证书时,相关内容和效力以电子证书为准;电子证书和纸质证书同时申领时,电子证书仅作为纸质证书的副本,相关内容和效力以同编号纸质证书为准 The relevant content and effectiveness is subject to the electronic version of the original report which was only applied for. When an electronic report and a paper report are applied for at the same time, the electronic report is only a copy of the paper report, and the relevant content and effectiveness is subject to the paper report. 9.证书中二维码具浏览和下载完整报告功能是应委托方选择所设,该二维码及其复制图能使任何人扫描获取完整的证书电子版,本证书持有人如需限制他人经该二维码获取证书内 容,应自行遮盖或消除证书及其复制件所附二维码,我院对委托方选择证书二维码功能所致的信息泄露概不负责(适用于附二维码证书)。 The QR code has the function of browsing and downloading complete report. Setting this function or not is chosen by the customer. The QR code and its copy enable anyone to scan and obtain the complete electronic version of the test report. Thus, if the owner of this report needs to restrict others from obtaining the content of the test report through the QR code, he shall cover or remove the QR code attached to the test report and its copies by himself. SMQ assumes no responsibility for the information leakage caused by the customer's selection of the QR code function of the test report(This clause applies to certificates with QR code attached).. 获得的国家、省、市专业站 Establishment of Following Institutions 国家数字电子产品质量检验检测中心 National Digital Electronic Product Testing Center (NETC) 国家营养食品质量检验检测中心(广东) National Nutrition Food Testing Center (Guangdong) 国家体育用品质量检验检测中心(广东) National Sports Product Testing Center (Guangdong) 国家环保产品质量检验检测中心(广东) National Environmental Product Testing Center (Guangdong) 国家分布式光伏发电系统质量检验检测中心(广东) National Distributed Photovoltaic Power Generation System Testing Center (Guangdong) 国家电动汽车电池及充电系统产业计量测试中心 National Metrology Center for Electric Vehicle Battery and Charging System Industry 国家民用无人机产品质量检验检测中心(广东) National Civil Unmanned Aerial Vehicle Product Testing Center (Guangdong) 国家高新技术计量站 National Hi-tech Metrology Station 国家医疗器械产业计量测试中心 National Metrology and Testing Center for Medical Device Industry 国家计量数据科学中心深圳分中心 National Metrology Data Science Center (Shenzhen) 国家城市能源计量中心(深圳) National Urban Energy Measurement Center (Shenzhen) 中国轻工业联合会家具质量监督检测深圳站 Accredited Testing Station (Shenzhen) for Furniture by China National Light Industry Council (CNLIC) 广东省质量监督食品检验站(深圳) Guangdong Quality Supervision and Inspection Institution for Food (Shenzhen) 广东省质量监督生态纺织服装产品检验站(深圳) Guangdong Quality Supervision and Inspection Institution for Ecological Textile and Garment Products (Shenzhen) 广东省质量监督皮革制品检验站 Guangdong Quality Supervision and Inspection Institution for Leather Products 广东省质量监督家具检验站(深圳) Guangdong Quality Supervision and Inspection Institution for Furniture Products (Shenzhen) 广东省质量监督学生用品检验站(深圳) Guangdong Quality Supervision and Inspection Institution for Student's Articles (Shenzhen) 广东省质量监督自行车检验站 Guangdong Quality Supervision and Inspection I…
Text truncated - open the document above for the full version.
Page: 1/7 Ref : ACR.41.3.25.BES.A BTF TESTING LAB (SHENZHEN) CO., LTD. F101,201 AND 301, BUILDING 1, BLOCK 2, TANTOU INDUSTRIAL PARK, TANTOU COMMUNITY SONGGANG STREET, BAO'AN DISTRICT, SHENZHEN, CHINA MVG COMOHAC T-COIL PROBE SERIAL NO.: SN 07/17 TCP38 Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 02/05/2025 Accreditations #2-6789 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited COMOHAC T-coil Probe calibration performed at MVG, using the COMOHAC test bench, for use with a MVG COMOHAC system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOHAC T-coil Probe Calibration Report Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC T-COIL PROBE CALIBRATION REPORT Ref: ACR.41.3.25.BES.A Page: 2/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC T Coil Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 2/10/2025 Checked & approved by: Pedro Ruiz Technical Manager 2/10/2025 Authorized by: Geraldine Toutain Quality Manager Customer Name Distribution : BTF Testing Lab (Shenzhen) Co., Ltd. Issue Name Date Modifications A Pedro Ruiz 2/10/2025 Initial release Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 2/10/2025 COMOHAC T-COIL PROBE CALIBRATION REPORT Ref: ACR.41.3.25.BES.A Page: 3/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC T Coil Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 4 3.3 Signal to Noise Measurement of the Calibration System ___________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Results ..................................................................................................... 5 5.1 Sensitivity _______________________________________________________________ 5 6 Verification Results ................................................................................................... 6 6.1 Linearity ________________________________________________________________ 6 6.2 Signal to Noise measurement of the Calibration System ___________________________ 6 7 List of Equipment ...................................................................................................... 7 Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC T-COIL PROBE CALIBRATION REPORT Ref: ACR.41.3.25.BES.A Page: 4/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC T Coil Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOHAC T-COIL PROBE Manufacturer MVG Model STCOIL Serial Number SN 07/17 TCP38 Product Condition (new / used) Used Frequency Range of Probe 200-5000 Hz 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOHAC T-coil Probes are built in accordance to the ANSI C63.19 and IEEE 1027 standards. Figure 1 – MVG COMOHAC T-coil Probe Coil Dimension 6.55 mm length * 2.29 mm diameter DC resistance 860.6 Ω Wire size 51AWG Inductance at 1 kHz 132.1 mH at 1 kHz 3 MEASUREMENT METHOD All methods used to perform the measurements and calibrations comply with the ANSI C63.19 and IEEE 1027 standards. All measurements were performed using a Helmholtz coil built according to the specifications outlined in ANSI C63.19 and IEEE 1027. 3.1 SENSITIVITY The T-coil was positioned within the Helmholtz coil in axial orientation. Using an audio generator connected to the input of the Helmholtz coil, a known field (1 A/m) was generated within the coil and the T-coil probe reading recorded over the frequency range of 100 Hz to 1000 Hz. 3.2 LINEARITY The T-coil probe was positioned within the Helmholtz coil in axial orientation. The audio generator connected to the input of the Helmholtz coil was adjusted to obtain a field within the coil from 0 dB A/m to -50 dB A/m and the T-coil reading recorded at each power level (10 dB steps). Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC T-COIL PROBE CALIBRATION REPORT Ref: ACR.41.3.25.BES.A Page: 5/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC T Coil Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.3 SIGNAL TO NOISE MEASUREMENT OF THE CALIBRATION SYSTEM The T-coil probe was pos…
Text truncated - open the document above for the full version.
Page: 1/7 Ref : ACR.41.4.25.BES.A BTF TESTING LAB (SHENZHEN) CO., LTD. F101,201 AND 301, BUILDING 1, BLOCK 2, TANTOU INDUSTRIAL PARK, TANTOU COMMUNITY SONGGANG STREET, BAO'AN DISTRICT, SHENZHEN, CHINA MVG COMOHAC E-FIELD PROBE SERIAL NO.: SN 07/22-EPH-50 Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 02/05/2025 Accreditations #2-6789 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited COMOHAC E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMOHAC system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOHAC E-Field Probe Calibration Report Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC E-FIELD PROBE CALIBRATION REPORT Ref: ACR.41.4.25.BES.A Page: 2/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC E field Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 2/10/2025 Checked & approved by: Pedro Ruiz Technical Manager 2/10/2025 Authorized by: Geraldine Toutain Quality Manager Customer Name Distribution : BTF Testing Lab (Shenzhen) Co., Ltd. Issue Name Date Modifications A Pedro Ruiz 2/10/2025 Initial release Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 2/10/2025 COMOHAC E-FIELD PROBE CALIBRATION REPORT Ref: ACR.41.4.25.BES.A Page: 3/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC E field Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 4 3.3 Isotropy _________________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Results ..................................................................................................... 5 5.1 Calibration in air __________________________________________________________ 5 6 Verification results ..................................................................................................... 6 7 List of Equipment ...................................................................................................... 7 Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC E-FIELD PROBE CALIBRATION REPORT Ref: ACR.41.4.25.BES.A Page: 4/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC E field Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOHAC E FIELD PROBE Manufacturer MVG Model SCE Serial Number 0722-EPH-50 Product Condition (new / used) Used Frequency Range of Probe 0.7GHz-2.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.208 M Dipole 2: R2=0.212 M Dipole 3: R3=0.213 M 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOHAC E field Probes are built in accordance to the ANSI C63.19 and IEEE 1309 standards. Figure 1 – MVG COMOHAC E field Probe Probe Length 330 mm Length of Individual Dipoles 3.3 mm Maximum external diameter 8 mm Probe Tip External Diameter 5 mm Distance between dipoles / probe extremity 3 mm 3 MEASUREMENT METHOD All methods used to perform the measurements and calibrations comply with the ANSI C63.19 and IEEE 1309 standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using the waveguide method outlined in the fore mentioned standards. 3.2 LINEARITY The linearity was determined using a standard dipole with the probe positioned 10 mm above the dipole. The input power of the dipole was adjusted from -15 to 36 dBm using a 1dB step (to cover the range 2V/m to 1000A/m). Docusign Envelope ID: 8FC27CB6-8F2D-40E8-888F-4F32BBB1F3C6 COMOHAC E-FIELD PROBE CALIBRATION REPORT Ref: ACR.41.4.25.BES.A Page: 5/7 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOHAC E field Probe vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.3 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. 4 MEASUREMENT UNCERTAINTY The guidelines outlined in the ANSI C63.19 and IEEE 1309 standards were followed to generate the measurement uncertainty associated with an E-field probe calibration using the waveguide technique. The estimated expanded u…
Text truncated - open the document above for the full version.
TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 49 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China HACReceiveVolumeControlTestReport For ApplicantName: Schok,LLC. Address: 5850TownandCountryBlvd,Suite203|Frisco,TX75034 EUTName: 5GSmartphone BrandName: Schok ModelName: SchokVoltSV69S IssuedBy CompanyName: BTFTestingLab(Shenzhen)Co.,Ltd. Address: 101/201/301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangSubdistrict,Bao'anDistrict, Shenzhen,China ReportNumber: BTF250926R00103 TestStandards: ANSIC63.19:2019FCC47CFR§20.19TIA-5050:2018 FCCID: 2AM9L-SV69S TestConclusion: Pass TestDate: 2025-11-15to2025-11-24 DateofIssue: 2025-12-01 TestedBy: KrisLi/Tester Date:2025-12-01 ReviewedBy: AmendaZhong/ProjectEngineer Date: 2025-12-01 ApprovedBy: Ryan.CJ/EMCManager Date: 2025-12-01 Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. TestReportNumber:BTF250926R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 49 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China RevisionHistory VersionIssueDateRevisionsContent Rev_V02025-12-01Original Note:Oncetherevisionhasbeenmade,thenpreviousversionsreportsare replacedbythelatestversion. TestReportNumber:BTF250926R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 49 BTFTestingLab(Shenzhen)Co.,Ltd. 101/201/301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangSubdistrict,Bao'anDistrict,Shenzhen,China TableofContents 1.Introduction...............................................................................................................................................................................4 1.1IdentificationofTestingLaboratory.................................................................................................................................4 1.2IdentificationoftheResponsibleTestingLocation..........................................................................................................4 1.3LaboratoryCondition.......................................................................................................................................................4 1.4Announcement................................................................................................................................................................4 2.ProductInformation..................................................................................................................................................................5 2.1ApplicationInformation..........................…
Text truncated - open the document above for the full version.
5850 Town and Country Blvd Suite 203 · Frisco, 75034 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 35.00 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 34.00 mW |
| 3 | 15E | 5.50 GHz - 5.70 GHz | 32.00 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 29.00 mW |