Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date: April 9, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AMD4UTO-NBL-54L) [Utovertek Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Sung-Jae Lee, CEO Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date: April 9, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AMD4UTO-NBL- 54L) [Utovertek Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Sung-Jae Lee, CEO
iCertifi Control Number - IC2026ASOP12262 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 25/03/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2AMD4UTO-NBL-54L Utovertek Co.,Ltd. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi is our designated U.S. agent for service of process for the above referenced FCC ID. Manufacturer accepts to maintain an agent for no less than two year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance Consulting LLC dba iCertifi FCC FRN: 0033399411 Address: 5809 US-2, Suite B, Albeni Plaza Priest River, Idaho 83856, United States Contact Person: Paul Preston Tel: +1 (866) 885-4575 Email: [email protected] Sincerely, Utovertek Co.,Ltd.Americas Compliance Consulting LLC dba iCertifi FRN: 0026589333FRN: 0033399411 Sung-Jae LeePaul Preston [email protected]@icertifi.com +82-31-781-2593+1 (866) 885-4575 Signature: Signature:
Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date: April 9, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (BLE module/UTO-NBL-54L AND 2AMD4UTO-NBL-54L) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be permanently withheld from public review. Permanent Confidential Request -. Schematics -. Block Diagram -. Operational Description SPECIFY REASON FOR REQUEST (i.e. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, Sung-Jae Lee, CEO
Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date: April 9, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (BLE module/UTO-NBL-54L AND 2AMD4UTO-NBL-54L)To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be short-term Confidentiality f or a period of 180 days after grant is issued. Short-Term Confidential Request -. External Photos -. Internal Photos -. Test set-up photo -. User Manual SPECIFY REASON FOR REQUEST (i.e. These documents contain detailed system and equipment descriptions and related information about the product, which we considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, we feel that this information would be of benefit to our competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Sung-Jae Lee, CEO
Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date: April 06, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Ms. Sonia Ham /Assistant Manager in Eurofins KCTL Co.,Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Sung-Jae Lee, CEO
Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Date : 2026. 04. 09. Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 SUBJECT : Family models’ difference FCC ID: 2AMD4UTO-NBL-54L This is to request a family models’ change for FCC ID: 2AMD4UTO-NBL-54L. The differences are below. Change of antenna type and gain; Item UTO-NBL-54L UTO-NBL-54LA Type Dipole Antenna Chip Antenna Gain 6.15dBi 1.99dBi Appreance There is no difference in performance due to the above changes. If you have any questions regarding this application, please feel free to contact me. Sincerely, Sung-Jae Lee, CE O
Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Request for Modular/Limited Modular Approval Date: April 24, 2026 Subject: Manufacturer’s Declaration for ☒ - Modular Approval ☐ - Split Modular Approval ☐ - Limited Modular Approval ☐ - Limited Split Modular Approval Confidentiality Request for: 2AMD4UTO-NBL-54L 8 Basic Requirements – FCC Part 15.212(a)(1) For Items Marked “NO(*)”, the Limited Module Description Must be Filled Out on the Following Pages Modular Approval Requirement Requirement Met 1. The modular transmitter must have its own RF shielding. This is intended to ensure that the module does not have to rely upon the shielding provided by the device into which it is installed in order for all modular transmitter emissions to comply with FCC limits. It is also intended to prevent coupling between the RF circuitry of the module and any wires or circuits in the device into which the module is installed. Such coupling may result in non-compliant operation. The physical crystal and tuning capacitors may be located external to the shielded radio elements. 15.212(a)(1)(i) ☒ - YES ☐ - NO(*) Details: <example – The module contains a metal shield which covers all RF components and circuitry. The shield is located on the top of the board next to antenna connector> 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with FCC requirements under conditions of excessive data rates or over-modulation. 15.212(a)(1)(ii) ☒ - YES ☐ - NO(*) Details: <example – Data to the modulation circuit is buffered as described in the operational description provided with the application> 3. The modular transmitter must have its own power supply regulation on the module. This is intended to ensure that the module will comply with FCC requirements regardless of the design of the power supplying circuitry in the device into which the module is installed. 15.212(a)(1)(iii) ☒ - YES ☐ - NO(*) Details: <example – The module contains its own power supply regulation. Please refer to schematic filed with this application> 4. The modular transmitter must comply with the antenna and transmission system requirements of §§ 15.203, 15.204(b), 15.204(c), 15.212(a), and 2.929(b). The antenna must either be permanently attached or employ a ‘‘unique’’ antenna coupler (at all connections between the module and the antenna, including the cable). The ‘‘professional installation’’ provision of § 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph 15.212(b). 15.212(a)(1)(iv) ☒ - YES ☐ - NO(*) Details: <example – The module connects to its antenna using an UFL connector which is considered a non-standard connector. A list of antennas tested and approved with this device may be found in users manual provided with the application> 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with Part 15 emission limits regardless of the device into which it is eventually installed. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in Section 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see Section 15.27(a)). The length of these lines shall be length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified or commercially available (see Section 15.31(i)). 15.212(a)(1)(v) ☒ - YES ☐ - NO(*) Details: <example – The module was tested stand-alone as shown in test setup photographs filed with this application> Utovertek Ltd. Rm 1111, 24 Dunchon-daero, 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, KOREA Modular Approval Requirement Requirement Met 6. The modular transmitter must be labeled with its own FCC ID number, or use an electron display (see KDB Publication 784748). If using a permanently affixed label with its own FCC ID number, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. If the modular transmitter uses an electronic display of the FCC identification number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC certified transmitter module(s).” Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be included in the application for equipment authorization. 15.212(a)(1)(vi) ☒ - YES ☐ - NO(*) Details: <example – There is a label on the module as shown in the labeling exhibit filed with this a…
Text truncated - open the document above for the full version.
Model Name : UTO-NBL-54L, Label Sample & Location FCC ID: 2AMD4UTO-NBL-54L ISED ID: 27695-UTONBL54L Model: UTO-NBL-54L Label location 330mm Model Name : UTO-NBL-54LA, Label Sample & Location FCC ID: 2AMD4UTO-NBL-54L ISED ID: 27695-UTONBL54L Model: UTO-NBL-54L Label location 330mm A
FCC ID: 2AMD4UTO-NBL-54L According to KDB 447498 D04 Interim General RF Exposure Guidance v01 1. MPE-based Exemption General frequency and separation-distance dependent MPE-based effective radiated power (ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(1)(i)(C)] to support an exemption from further evaluation from 300 ㎑ through 100 ㎓. Table 1: THRESHOLDS FOR SINGLE RF SOURCES SUBJECT TO ROUTINE ENVIRONMENTAL EVALUATION RF Source Frequency Minimum Distance Threshold ERP f L (㎒) f H (㎒) λ L / 2π λ H / 2π W 0.3 - 1.34 159 m - 35.6 m 1 920 R2 1.34 - 30 35.6 m - 1.6 m 3 450 R 2 /f 2 30 - 300 1.6 m - 159 mm 3.83 R 2 300 - 1 500 159 mm - 31.8 mm 0.012 8 R 2 f 1 500 - 100 000 31.8 mm - 0.5 mm 19.2 R 2 Subscripts L and H are low and high; λ is wavelength. From § 1.1307(b)(3)(i)(C), modified by adding Minimum Distance columns. The table applies to any RF source (i.e., single fixed, mobile, and portable transmitters) and specifies power and distance criteria for each of the five frequency ranges used for the MPE limits. These criteria apply at separation distances from any part of the radiating structure of at least λ/2π. The thresholds are based on the general population MPE limits with a single perfect reflection, outside of the reactive near-field, and in the main beam of the radiator. For mobile devices that are not exempt per Table B.1 [Table 1 of § 1.1307(b)(1)(i)(C)] at distances from 20 ㎝ to 40 ㎝ and in 0.3 ㎓ to 6 ㎓, evaluation of compliance with the exposure limits in § 1.1310 is necessary if the ERP of the device is greater than ERP 20 ㎝ in Formula (B.1) [repeated from § 2.1091(c)(1) and § 1.1307(b)(1)(i)(B)]. If the ERP is not easily obtained, then the available maximum time-averaged power may be used (i.e., without consideration of ERP only if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole. SAR-based exemptions are constant at separation distances between 20 ㎝ and 40 ㎝ to avoid discontinuities in the threshold when transitioning between SAR-based and MPE-based exemption criteria at 40 ㎝, considering the importance of reflections. 2. RF Exposure Test Exemptions for Single Source Mode Frequency Range (㎒) Minimum Separation Distance (㎝) Maximum Average Target Power (㏈m) Maximum Tune up (㏈) Maximum Average Output Power Worst Ant. Gain (㏈i) ERP Limits P th (㎽) Ratio Result (㏈m) (㎽) (㏈m) (㎽) Bluetooth Low Energy 2 402 ~ 2 480 20 6.0 1.0 7.0 5.012 6.15 11.00 12.589 768 0.016 Pass Note ; - ERP (㏈m) = Maximum average power (㏈m) + Worst Antenna gain (㏈i) -2.15 - Maximum average target power is the manufacturer’s declared rated power. - Maximum average output power = Maximum average target power (㏈m) + Maximum tune up (㏈). 3. Conclusion: No SAR is required.
Model name: UTO-NBL-54L Item Contents Antenna Type Dipole Antenna Antenna peak gain 6.15 ㏈i Manufacturer / Model name Fanstel Corp. / ANT060 Address of manufacturer 7466 E. Monte Cristo Ave. Scottsdale, AZ 85260 USA Test Laboratory Fanstel Corp. Antenna Length 195 mm Antenna Width 13 mm Antenna Information Length Width Freqency (MHz) Peak Gain (dBi) Avg-gain (dBi) Efficiency (%) 2400 6.06 -0.82 85 2450 6.15 -0.65 90 2500 6.22 -0.77 88 Model name: UTO-NBL-54LA Item Contents Antenna Type Chip Antenna Antenna peak gain 1.99 ㏈i Manufacturer / Model name DIT Corp. / AHSBTF0402-L00 Address of manufacturer 355-50, Gajang-ro, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of South Korea Test Laboratory DIT Corp. Antenna Length 4.0 mm Antenna Width 2.0 mm Antenna Information Length Width Photo / Graph 2450.000Mhz Typical Test Board Recommended Pad Layout Gain on Evaluation Board (3D) Frequency (MHz) 3D Data Peak Gain Avg. Gain 2400 -0.4 -3.3 2450 1.9 -1.0 2500 1.0 -1.8 Ant 50 ohm Feeding No ground area <Ground Plane> 42 1.2 mm gap from ground 37 Matching circuit added in the feeding line - T-type : series + shunt - π-type : shunt + series + shunt (unit : dBi) 1: Input Pad 2: Ground Pad 3: Ground Pad 4: Non-Contact (For SMT) ③ ① ④ ② 2 4 1 2 0 . 8 ① ② ③ ④ 0.5 0.5 0.5
SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 2 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) INDEX Table of contents 1. General Information -------------------------------------------------------------------------------------- 3 2. Transmitter Radiated Spurious Emissions and Conducted Spurious Emissions ---------- 10 3. 6 ㏈ Bandwidth and 99 % Bandwidth ---------------------------------------------------------------- 53 4. Maximum Peak Conducted Output Power --------------------------------------------------------- 60 5. Power Spectral Density --------------------------------------------------------------------------------- 65 6. Antenna Requirement ----------------------------------------------------------------------------------- 69 SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 3 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1. General Information 1.1. Testing Laboratory SGS Korea Co., Ltd. (Gunpo Laboratory) - 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 - Designation number: KR0150 All SGS services are rendered in accordance with the applicable SGS conditions of service available on request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx. Phone No. : +82 31 688 0901 Fax No. : +82 31 688 0921 1.2. Details of Applicant FCC Applicant : Utovertek Co.,Ltd. FCC Address : RM210, KETI Business Incubator, 25 seanari-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea IC Applicant : UTOVERTEK IC Address : RM1111, 24, Dunchon-daero 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Contact Person : Lee, Sung-Jae Phone No. : +82 31 781 2593 1.3. Details of Manufacturer Company : UTOVERTEK Address : RM1111, 24, Dunchon-daero 388 beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 4 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.4. Description of EUT Kind of Product BLE module Model Name UTO-NBL-54L Variant Model Name(s) UTO-NBL-54LA Serial Number Conducted: C01 Radiated: R01 Power Supply DC 3.0 V Frequency Range 2 402 ㎒ ~ 2 480 ㎒ (Bluetooth Low Energy) Modulation Technique GFSK Number of Channels 40 channels (Bluetooth Low Energy) Maximum measured E.I.R.P. 12.55 ㏈m Antenna Type Basic Model Dipole Antenna Variant Model Chip Antenna Antenna Gain ※ Basic Model 6.15 ㏈i Variant Model 1.99 ㏈i H/W Version 1.0 S/W Version 1.0 FVIN N/A SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 5 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.5. Test Equipment List Equipment Manufacturer Model S/N Cal. Date Cal. Interval Cal. Due Signal Generator R&S SMA100B 106887 10/20/2025 Annual 10/20/2026 Spectrum Analyzer R&S FSV30 103455 02/02/2026 Annual 02/02/2027 Spectrum Analyzer Agilent N9020A MY53421758 09/10/2025 Annual 09/10/2026 Spectrum Analyzer Agilent N9030A US51350132 12/03/2025 Annual 12/03/2026 Attenuator AEROFLEX/INM ET 40AH2W-6 1 03/09/2026 Annual 03/09/2027 High Pass Filter Wainwright Instrument GmbH WHKX3.0/18G-6SS 4 06/09/2025 Annual 06/09/2026 High Pass Filter Wainwright Instrument GmbH WLKX10-6320-8000-26 500-40CC 6 10/22/2025 Annual 10/22/2026 Power Sensor R&S NRP-Z81 100669 05/24/2025 Annual 05/24/2026 DC Power Supply Agilent U8002A 019258024 10/24/2025 Annual 10/24/2026 Preamplifier H.P. 8447F 2944A03909 08/07/2025 Annual 08/07/2026 Preamplifier TESTEK TK-PA1840H 130016 03/06/2026 Annual 03/06/2027 Signal Conditioning Unit R&S SCU-18F 100959 01/05/2026 Annual 01/05/2027 Loop Antenna Schwarzbeck Mess-Elektronik FMZB 1519 1519-039 10/01/2025 Biennial 10/01/2027 Bilog Antenna Schwarzbeck Mess-Elektronik VULB 9163 01126 03/09/2026 Biennial 03/09/2028 Horn Antenna R&S HF906 100326 03/03/2026 Annual 03/03/2027 Horn Antenna Schwarzbeck Mess-Elektronik BBHA 9170 9170-540 12/05/2025 Annual 12/05/2026 EMI Test Receiver R&S ESU26 100109 01/21/2026 Annual 01/21/2027 Turn Table Innco systems GmbH DS 1200 S N/A N.C.R. N/A N.C.R. Controller Innco systems GmbH CONTROLLER CO3000-4P CO3000/963/38 330516/L N.C.R. N/A N.C.R. Antenna Mast Innco systems GmbH MA4640-XP-ET MA4640/536/38 330516/L N.C.R. N/A N.C.R. Anechoic Chamber SY Corporation L × W × H (9.6 m × 6.4 m × 6.6 m) N/A N.C.R. N/A N.C.R. Coaxial Cable SENSORVIEW NMST-13A26-NMST-5 m TPC240219000 4 04/13/2026 Semi- Annual 10/13/2026 Coaxial Cable SENSORVIEW NMST-13A26-NMST-10 m TPC240219000 1 04/13/2026 Semi- Annual 10/13/2026 Coaxial Cable RFONE PL360P-292M292M- 1.5M-A 20200324002 04/13/2026 Semi- Annual 10/13/2026 Note; For equipment listed above that has a calibration date or calibration due date that falls within the test date range, care was taken to ensure that this equipment was used after the calibration date and before the calibration due date SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 6 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1.6. Summary of Test Results The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 15 Subpart C, RSS-247 Issue 4 and RSS-Gen Issue 5 Section in FCC Section in IC Test Item(s) Result 15.205(a) 15.209 15.247(d) RSS-247 Issue 4 6.6 RSS-Gen Issue 5 8.9 Transmitter Radiated Spurious Emissions and Conducted Spurious Emission Pass 15.247(a)(2) RSS-247 Issue 4 6.3.1(a) RSS-Gen Issue 5 6.7 6 ㏈ Bandwidth & 99 % Bandwi…
Text truncated - open the document above for the full version.
SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 33 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1 ㎓ ~ 3 ㎓ 3 ㎓ ~ 18 ㎓ 18 ㎓ ~ 25 ㎓ (Peak) 18 ㎓ ~ 25 ㎓ (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 34 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Test Mode: PHY 2M Low channel band edge (Peak) Low channel band edge (Average) Low channel 2 nd harmonic (Peak) Low channel 3 rd harmonic (Peak) Low channel 5 th harmonic (Peak) Low channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 35 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Middle channel 2 nd harmonic (Peak) Middle channel 3 rd harmonic (Peak) Middle channel 3 rd harmonic (Average) Middle channel 5 th harmonic (Peak) Middle channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 36 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High channel band edge (Peak) High channel band edge (Average) High channel 2 nd harmonic (Peak) High channel 3 rd harmonic (Peak) High channel 3 rd harmonic (Average) High channel 5 th harmonic (Peak) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 37 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 38 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1 ㎓ ~ 3 ㎓ 3 ㎓ ~ 18 ㎓ 18 ㎓ ~ 25 ㎓ (Peak) 18 ㎓ ~ 25 ㎓ (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 39 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Variant Model (UTO-NBL-54LA) Test Mode: PHY 1M Low channel band edge (Peak) Low channel band edge (Average) Low channel 2 nd harmonic (Peak) Low channel 5 th harmonic (Peak) Low channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 40 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Middle channel 2 nd harmonic (Peak) Middle channel 3 rd harmonic (Peak) Middle channel 5 th harmonic (Peak) Middle channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 41 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High channel band edge (Peak) High channel band edge (Average) High channel 2 nd harmonic (Peak) High channel 3 rd harmonic (Peak) High channel 5 th harmonic (Peak) High channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 42 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1 ㎓ ~ 3 ㎓ 3 ㎓ ~ 18 ㎓ 18 ㎓ ~ 26 ㎓ (Peak) 18 ㎓ ~ 25 ㎓ (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 43 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Test Mode: PHY 2M Low channel band edge (Peak) Low channel band edge (Average) Low channel 2 nd harmonic (Peak) Low channel 5 th harmonic (Peak) Low channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 44 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Middle channel 2 nd harmonic (Peak) Middle channel 3 rd harmonic (Peak) Middle channel 5 th harmonic (Peak) Middle channel 5 th harmonic (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 45 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High channel band edge (Peak) High channel band edge (Average) High channel 2 nd harmonic (Peak) High channel 3 th harmonic (Peak) High channel 5 th harmonic (Peak) High channel 5 th harmonic (Average)
SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 46 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 1 ㎓ ~ 3 ㎓ 3 ㎓ ~ 18 ㎓ 18 ㎓ ~ 26 ㎓ (Peak) 18 ㎓ ~ 25 ㎓ (Average) SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 47 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) 2.4.3. Plot of Conducted Spurious Emissions Test Mode: PHY 1M Low Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 48 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Middle Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 49 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 50 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Test Mode: PHY 2M Low Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 51 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) Middle Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 52 of 69 RTT7081-02(2020.10.05)(0) A4(210 mm * 297 mm) High Channel SGS Korea Co., Ltd. 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807 Tel. +82 31 428 5700 / Fax. +82 31 427 2370 http://www.sgsgroup.kr Report Number: F690501-RF-RTL006837-3 Page: 53 of 69 RTT7081-02(2020.10.05)…
Text truncated - open the document above for the full version.
5809 US-2, Suite B, Albeni Plaza · 83856 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.06 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 5.02 mW |