FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Eliwell Controls srl/
  3. 2AMLEEDGEWIFI

2AMLEEDGEWIFIInterface for Refrigeration Controllers

Eliwell Controls srl

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 29, 2026
Application Purpose
Original Equipment
Equipment Note
Interface for Refrigeration Controllers
Frequency Range
5180.00000000 - 5240.00000000
Company
Eliwell Controls srl
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Eliwell AIR Eliwell AIR Silent Guardian User manual E_AIR-03EN 01/2026 www.eliwell.com Legal information The information provided in this document contains general descriptions, technical characteristics and/or recommendations related to products/solutions. This document is not intended as a substitute for a detailed study or operational and site-specific development or schematic plan. It is not to be used for determining suitability or reliability of the products/solutions for specific user applications. It is the duty of any such user to perform or have any professional expert of its choice (integrator, specifier or the like) perform the appropriate and comprehensive risk analysis, evaluation and testing of the products/solutions with respect to the relevant specific application or use thereof. The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this document are the property of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owner. This document and its content are protected under applicable copyright laws and provided for informative use only. No part of this document may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric. Schneider Electric does not grant any right or license for commercial use of the document or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. Schneider Electric reserves the right to make changes or updates with respect to or in the content of this document or the format thereof, at any time without notice. To the extent permitted by applicable law, no responsibility or liability is assumed by Schneider Electric and its subsidiaries for any errors or omissions in the informational content of this document, as well as any non-intended use or misuse of the content thereof. Table Of Contents Safety Information5 About the document7 Before first use12 Silent Guardian13 Eliwell AIR APP installation14 Eliwell AIR Cloud activation15 Product Information17 Overview18 Silent Guardian19 Main features21 EW AIR EDGE models22 Compatibility22 Languages supported24 Browser compatibility 24 Cybersecurity25 Overview26 Defense in Depth27 Security hardening guidelines28 Secure disposal guidelines28 Secure operation guidelines30 Account management guidelines31 Mechanical installation32 Before starting33 Disconnecting Power33 Operating environment34 Installation Considerations34 Mechanical dimensions EW AIR EDGE35 Panel mounting installation EW AIR EDGE36 Din-Rail mounting EW AIR EDGE37 Antenna configuration via jumper38 Electrical connections 39 Wiring Best Practices40 Installation42 Hardware EW AIR EDGE43 Connection example44 Technical specification45 Technical Data46 FCC USA and IC Canada47 Eliwell AIR APP functions49 First access to Eliwell AIR APP 50 First connection to the controller51 Menu53 Controller configuration54 Resources configuration56 Copy the configuration between controllers58 Eliwell AIR | User manual E_AIR-03EN03 01/2026 | © 2026 Eliwelliii History - Datalogging setup59 Connecting and recording data in Eliwell AIR Cloud60 Eliwell AIR Cloud functions61 Home page - List of connected controllers62 Telemetry of a connected controller64 Controller - Remote reading and writing66 Alarm rules management68 Automatic HACCP Report Setup70 Grouping of connected devices72 Phone/Tablet management73 Statistics74 ivEliwell AIR | User manual03 01/2026| E_AIR-03EN | © 2026 Eliwell Safety Information Important information Read these instructions carefully and visually inspect the equipment to familiarize yourself with the controller before installing it and/or putting it into operation or servicing it. The following warning messages may appear anywhere in this documentation or on the equipment to warn of potential dangers or to call attention to information that can clarify or simplify a procedure. The addition of this symbol to a "Danger" or "Warning" safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety warning symbol. It is used to warn the user of the potential dangers of personal injury. Observe all the safety warnings that follow this symbol to avoid the risk of serious injury or death. DANGER DANGERindicates a dangerous situation which, if not avoided,will result indeath or serious injury. WARNING WARNINGindicates a dangerous situation which, if not avoided,could result indeath or serious injury. CAUTION CAUTIONindicates a potentially dangerous situation which, if not avoided,could result inminor or moderate injury. NOTICE NOTICEused in reference to procedures not associated with physical injuries. Please Note Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric and Eliwell for any consequences arising out of the use of this material. An authorized person is someone in possession of the skills and knowledge applicable to the structure, to the operation of the electrical equipment and to its installation, and who has received safety training in order to recognize and avoid the risks involved. Personnel qualification Only personnel with suitable training and an in-depth knowledge and understanding of the contents of this manual and any other documentation relevant to the product are authorized to work on and with this product. Qualified personnel must be capable of identifying any dangers which may arise from the parameterization or changing of parameter values, and from the use of mechanical, electric and electronic equipment in general. Plus, they must be familiar with the personal safety laws, provisions and regulations which must be observed during system planning and implementation. El…

Text truncated - open the document above for the full version.

Users Manual

9IS6489800 9IS64898.01 06 - 2025 01/08 www.eliwell.com AIR Edge WiFi/WiFi-ETHERNET TTL SD DANGER / PERICOLO / PELIGRO / GEFAHR / DANGER / ОПАСНОСТЬ HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • Disconnect all power from all equipment including connected devices prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires except under the specific conditions specified in the appropriate hardware guide for this equipment. • Always use a properly rated voltage sensing device to confirm the power is off where and when indicated. • Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit. • Use only the specified voltage when operating this equipment and any associated products. Failure to follow these instructions will result in death or serious injury. RISCHIO DI SHOCK ELETTRICO, ESPLOSIONE O ARCO ELETTRICO • Mettere fuori tensione tutte le apparecchiature, inclusi i dispositivi collegati, prima di rimuovere qualunque coperchio o sportello o prima di installare/disinstallare accessori, hardware, cavi o fili, tranne che nelle condizioni specificate nella Guida hardware per questa apparecchiatura. • Per verificare che il sistema sia fuori tensione, usare sempre un voltmetro correttamente tarato al valore nominale della tensione. • Prima di riattivare l’alimentazione dell’unità rimontare e fissare tutti i coperchi, accessori, componenti hardware, cavi e fili e verificare la presenza di un buon collegamento di terra. • Utilizzare quest’apparecchiatura e tutti i prodotti collegati solo alla tensione specificata. Il mancato rispetto di queste istruzioni provocherà morte o gravi infortuni Il mancato rispetto di queste istruzioni provocherà morte o gravi infortuni. PELIGRO DE DESCARGA ELÉCTRICA, EXPLOSIÓN O ARCO ELÉCTRICO • Desconecte la alimentación de todos los equipos, incluidos los dispositivos conectados, antes de retirar cualquier cubierta o compuerta, o bien antes de instalar o retirar cualquier accesorio, hardware, cable o conductor, salvo en las condiciones específicas indicadas en la guía de hardware de este equipo. • Utilice siempre un dispositivo de detección de tensión nominal adecuado para confirmar la ausencia de alimentación eléctrica cuando y donde se indique. • Vuelva a montar y fijar todas las cubiertas, accesorios, elementos de hardware y cables del sistema y compruebe que haya una conexión a tierra adecuada antes de aplicar aliment- ación eléctrica a la unidad. • Aplique solo la tensión especificada cuando utilice este equipo y los productos asociados. El incumplimiento de estas instrucciones podrá causar la muerte o lesiones serias. GEFAHR EINES ELEKTRISCHEN SCHLAGS, EINER EXPLOSION ODER EINES LICHTBOGENS • Trennen Sie alle Geräte, einschließlich der angeschlossenen Komponenten, vor der Entfernung von Abdeckungen oder Türen sowie vor der Installation oder Entfernung von Zubehörteilen, Hardware, Kabeln oder Drähten von der Spannungsversorgung, ausgenom- men unter den im jeweiligen Hardwarehandbuch für diese Geräte angegebenen Bedingungen. • Verwenden Sie stets ein genormtes Spannungsprüfgerät, um festzustellen, ob die Spannungsversorgung wirklich abgeschaltet ist. • Bringen Sie alle Abdeckungen, Zubehörteile, Hardware, Kabel und Drähte wieder an, sichern Sie sie und vergewissern Sie sich, dass eine ordnungsgemäße Erdung vorhanden ist, bevor Sie die Spannungszufuhr zum Gerät einschalten. • Betreiben Sie dieses Gerät und jegliche zugehörigen Produkte nur mit der angegebenen Spannung. Die Nichtbeachtung dieser Anweisungen führt zu Tod oder schweren Verletzungen. RISQUE D’ÉLECTROCUTION, D’EXPLOSION OU D’ARC ÉLECTRIQUE • Coupez toutes les alimentations de tous les équipements, y compris les équipements connectés, avant de retirer les caches ou les portes d’accès, ou avant d’installer ou de retirer des accessoires, matériels, câbles ou fils, sauf dans les cas de figure spécifiquement indiqués dans le guide de référence du matériel approprié à cet équipement. • Utiliser toujours un appareil de mesure de tension réglé correctement pour s'assurer que l'alimentation est coupée conformément aux indications. • Remettez en place et fixez tous les caches de protection, accessoires, matériels, câbles et fils et vérifiez que l’appareil est bien relié à la terre avant de le remettre sous tension. • Utilisez uniquement la tension indiquée pour faire fonctionner cet équipement et les produits associés. Le non-respect de ces instructions provoquera la mort ou des blessures graves. ОПАСНОСТЬ ПОРАЖЕНИЯ ЭЛЕКТРИЧЕСКИМ ТОКОМ, ВЗРЫВА ИЛИ ВСПЫШКИ ДУГИ • Полностью отключите электропитание от всего оборудования, в том числе подключенных устройств, до снятия любых крышек или дверей или до установки или демонтажа любых спомогательных устройств, аппаратуры, кабелей или проводов, за исключением особых ситуаций, указанных в руководстве по аппаратной части данного оборудования. • В указанных местах и условиях обязательно используйте обладающий соответствующими характеристиками датчик напряжения для проверки отключения электропитания. • Установите на место и закрепите все крышки, вспомогательные устройства, аппаратуру, кабели и провода и до подачи электропитания на блок удостоверьтесь в наличии надлежащего заземляющего соединения. • Для электропитания данного оборудования и любых связанных с ним изделий используйте источники электропитания подходящего напряжения. Несоблюдение этих инструкций приведет к смерти или серьезной травме. EW AIR Edge is compatible with all Eliwell AIR devices / EW AIR Edge è compatibile con tutti gli strumenti AIR Eliwell / EW AIR Edge es compatible con todos los dispositivos AIR Eliwell / EW AIR Edge ist mit allen AIR Eliwell Geräten kompatibel / EW AIR Edge est compatible avec tous les appareils AIR Eliwell / EW AIR Edge совместим со всеми устройствами AIR Eliwell. DANGER / PERICOLO / PELIGRO / GEFAHR / DANGER / ОПАСНОСТЬ HAZARD OF ELE…

Text truncated - open the document above for the full version.

Test Setup Photos

Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 1 Test Setup Photographs for the Model No./PMN: AIR EDGE WiFi-Eth RS485 SD 1. Radiated Test Setup Photo 1 Radiated Test Setup Mount Antenna from 9 kHz to 30 MHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 2 Photo 2 Radiated Test Setup Mount Antenna from 9 kHz to 30 MHz Photo 3 Radiated Test Setup PCB Antenna from 9 kHz to 30 MHz Photo 4 Radiated Test Setup PCBs Antenna from 9 kHz to 30 MHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 3 Photo 5 Radiated Test Setup Mount Antenna from 30 MHz to 1 GHz Photo 6 Radiated Test Setup Mount Antenna from 30 MHz to 1 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 4 Photo 7 Radiated Test Setup PCB Antenna from 30 MHz to 1 GHz Photo 8 Radiated Test Setup PCB Antenna from 30 MHz to 1 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 5 Photo 9 Radiated Test Setup Mount Antenna from 1 GHz to 18 GHz Photo 10 Radiated Test Setup Mount Antenna from 1 GHz to 18 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 6 Photo 11 Radiated Test Setup PCB Antenna from 1 GHz to 18 GHz Photo 12 Radiated Test Setup PCB Antenna from 1 GHz to 18 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 7 Photo 13 Radiated Test Setup Mount Antenna from 18 GHz to 25 GHz Photo 14 Radiated Test Setup Mount Antenna from 18 GHz to 25 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 8 Photo 15 Radiated Test Setup PCB Antenna from 18 GHz to 25 GHz Photo 16 Radiated Test Setup PCB Antenna from 18 GHz to 25 GHz Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 9 2. Conducted Test Setup Photo 17 Conducted Test Setup Photo 18 Conducted Test Setup Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 10 Photo 19 DFS Test Setup Eliwell Controls srl FCC ID: 2AMLEEDGEWIFI UL-RPT-14684854 IC: 9727A-EDGEWIFI UL International Germany GmbH 11 3. AC Conducted Emissions Photo 20 AC Conducted Test Setup PCB Antenna Photo 21 AC Conducted Test Setup PCB Antenna

Test Report

SPE-16-8-077/A Page 1 of 29 Specification Part No. : WSA.2458.A.101151 Product Name : Phoenix WSA.2458 Dual Band Wi-Fi I-Bar 2.4/5.8GHz Antenna with 1M RG-174 RP-SMA(M) Feature : Wi-Fi/WLAN Adhesive Mount Antenna 1m RG-174 cable with RP-SMA(M) connector Low Profile for Ease of Installation Fully Customizable Cable and Connector 105*30*7.7mm RoHS compliant SPE-16-8-077/A Page 2 of 29 1. Introduction The Phoenix WSA.2458 I-Bar antenna is a robust and low profile, dipole antenna operating on both the 2.4/5.8GHz bands for Wi-Fi applications. The Phoenix has a slim-line design, which allows for covert and convenient installation in any application, while its omnidirectional radiation pattern and 2.1dBi gain ensure constant reception and transmission. It is manufactured and tested in a TS16949 first tier automotive approved facility and has undergone full PPAP design, reliability and quality audits. The Phoenix is especially suited for applications such as first-tier automotive applications, aftermarket and telematics. The Phoenix has exceptional industry performance characteristics considering its very low profile (just 7.7mm) and compact size (105*30mm). This UV resistant antenna is designed to be mounted on glass or plastic but should not be mounted on a metal base. It comes with strong 3M double-sided adhesive for a permanent and secure fix to your application. Cable lengths, types and connectors are fully customizable. SPE-16-8-077/A Page 3 of 29 2. Specification Wi-Fi Frequency 2400~2500MHz 4900~5850MHz Efficiency (%) In free space 0.3m 68.23 47.03 1m 54.10 33.08 2m 38.61 20.16 3m 27.62 12.13 5m 14.32 4.45 On glass 0.3m 70.19 40.72 1m 55.64 28.64 2m 39.72 17.47 3m 28.42 10.51 5m 14.73 3.86 On the 2mm ABS 0.3m 69.94 46.77 1m 55.43 32.90 2m 39.58 20.05 3m 28.31 12.06 5m 14.67 4.43 Average Gain(dBi) In free space 0.3m -1.66 -3.30 1m -2.67 -4.84 2m -4.13 -7.00 3m -5.59 -9.22 5m -8.44 -13.59 On glass 0.3m -1.54 -3.94 1m -2.55 -5.48 2m -4.01 -7.64 3m -5.46 -9.86 5m -8.32 -14.23 On the 2mm ABS 0.3m -1.55 -3.33 1m -2.56 -4.86 2m -4.03 -7.02 3m -5.48 -9.24 5m -8.33 -13.62 SPE-16-8-077/A Page 4 of 29 Peak Gain(dBi) In free space 0.3m 2.65 3.19 1m 1.55 1.73 2m 0.15 -0.31 3m -1.35 -2.41 5m -4.25 -6.61 On glass 0.3m 3.98 4.22 1m 2.89 2.72 2m 1.48 0.62 3m -0.02 -1.58 5m -2.89 -5.88 On the 2mm ABS 0.3m 2.95 4.31 1m 1.89 2.81 2m 0.45 0.81 3m -1.05 -1.29 5m -3.91 -5.49 Return loss < -10 dB VSWR ≤ 2:1 Impedance 50Ω Polarization Linear Radiation Pattern Omnidirectional Input Power 2W MECHANICAL Dimensions 105*30*7.7mm Casing PC/ABS Connector RP-SMA(M) Cable RG-174 Weight 50g ENVIRONMENTAL Temperature Range -40°C to 85°C SPE-16-8-077/A Page 5 of 29 3. Antenna Characteristics 3.1 Antenna Test Setup Free Space On Glass On 2mm ABS SPE-16-8-077/A Page 6 of 29 3.2 Return Loss 3.3 Efficiency SPE-16-8-077/A Page 7 of 29 3.4 Peak Gain 3.5 Average Gain SPE-16-8-077/A Page 8 of 29 4 Antenna Radiation Patterns 4.1 Antenna setup (Free space with 1 meter cable length) Free Space On Glass On 2mm ABS Antenna testing Setup in ETS Anechoic Chamber Y X Z Z Z X X Y Y SPE-16-8-077/A Page 9 of 29 4.2 2D Radiation Patterns 4.2.1 Free Space XY Plane SPE-16-8-077/A Page 10 of 29 XZ Plane SPE-16-8-077/A Page 11 of 29 YZ Plane SPE-16-8-077/A Page 12 of 29 4.2.2 On Glass XY Plane SPE-16-8-077/A Page 13 of 29 XZ Plane SPE-16-8-077/A Page 14 of 29 YZ Plane SPE-16-8-077/A Page 15 of 29 4.2.3 On 2mm ABS XY Plane SPE-16-8-077/A Page 16 of 29 XZ Plane SPE-16-8-077/A Page 17 of 29 YZ Plane SPE-16-8-077/A Page 18 of 29 4.3 Antenna 3D Radiation Pattern 4.3.1 Free Space 2450MHz 5550MHz SPE-16-8-077/A Page 19 of 29 4.3.2 On Glass 2450MHz 5550MHz SPE-16-8-077/A Page 20 of 29 4.3.3 On 2mm ABS 2450MHz 5550MHz SPE-16-8-077/A Page 21 of 29 5 Drawing (Unit: mm) SPE-16-8-077/A Page 22 of 29 6 Packaging SPE-16-8-077/A Page 23 of 29 7 Application Note The WSA.2458 antenna performance with different cable lengths is shown below. 7.1 In free Space Return Loss Efficiency SPE-16-8-077/A Page 24 of 29 Peak Gain Average Gain SPE-16-8-077/A Page 25 of 29 7.2 On Glass Return Loss Efficiency SPE-16-8-077/A Page 26 of 29 Peak Gain Average Gain SPE-16-8-077/A Page 27 of 29 7.3 On 2mm ABS Return Loss Efficiency SPE-16-8-077/A Page 28 of 29 Peak Gain Average Gain SPE-16-8-077/A Page 29 of 29 Taoglas makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Taoglas reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. © Taoglas Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Taoglas: WSA.2458.A.101151

Test Report

F-Lab Site Volta : 37, Quai Paul Louis Merlin F-38050 GRENOBLE Cedex 9 Site Amplitude : 31, rue pierre Mendès France 38320 Eybens Tél. +33 (0)4 76 60 51 72 FLAB-GEN-SUP-28 v9 Test report Results N° : SPEC26AA1346_V3 RF Test Report Cancels and replaces test report number SPEC26AA1346_V2 Delivered to : Eliwell Controls srl Via Dell'Industria, 15 Zona Industriale Paludi 32016 Alpago (BL), Italy Device under test : AIR EDGE WiFi Ethernet RS485 SD 100-240V Reference : AEBWE0T0001100 Trade mark : Eliwell by SCHNEIDER ELECTRIC Manufacturer : Eliwell Controls srl Type/Nature of test : Antenna gain & pattern measurement WIFI 5GHz Standard : Non standard test method Date(s) of the tests : From 14/01/2026 to 15/01/2026 Place of tests : F-Lab Site Volta Gain value : U EUT (V) Channel Frequency (MHz) 2D peak Gain (dBi) 3D peak Gain (dBi) 230 Vac Low 36 5180 7.73 8.41 230 Vac Medium 100 5500 7.99 8.61 230 Vac High 165 5825 8.02 8.71 The results obtained during the tests consigned in this test report justify the above assigned characteristics stated by the manufacturer. To declare, or not, the compliance according the standard, it was not taken into account of uncertainty measurements in the test results. This document results from tests carried out on a sample. It does not prejudge the compliance of the whole manufactured products with the tested specimen. In the case of an amendment to this test report, we draw your attention to the risks of keeping obsolete version. Each new version cancels and replaces the previous one. Any expired copies must be destroyed. Any modification to this report is identified by a line in the margin. The reproduction of this test report is authorized only in the form of integral photographic facsimile. (): Information provided by the customer; the laboratory is not responsible for information provided by the customer. This report contains 50 pages Dispatch date of report: 26/03/2026 Writer Approver MICHALLET-FERRIER Lylian BOURET Loïc Technical leader Test report N° SPEC26AA1346_V3 Page 2/50 Internal SUMMARY 1 CONFIGURATION OF TEST INFORMATIONS  ................................................................................3 2 MEASUREMENT SETUP AND TEST DETAILS ..................................................................................5 3 RESULTS ............................................................................................................................................ 11 4 CURVES EIRP LOW CHANNEL (5180 MHZ) ................................................................................... 12 5 CURVES EIRP MIDLE CHANNEL (5500 MHZ) ................................................................................. 25 6 CURVES EIRP HIGHT CHANNEL (5825 MHZ) ................................................................................. 38 7 ANNEX 2 – VALIDITY OF TEST MEANS ......................................................................................... 50 History table Version Dated Author Description V1 12/02/2026 MICHALLET-FERRIER Lylian Initial version V2 09/03/2026 Loïc Bouret Addition a comment for explain screenshot P.8, P.9 & P.10 Adding the formula via software to the results table P.11 V3 26/03/2026 loïc Bouret Addition conducted power measurement P.11 TEST ENGINEERS Person Title / Function Company MICHALLET-FERRIER Lylian Test engineer Schneider Electric Test report N° SPEC26AA1346_V3 Page 3/50 Internal 1 CONFIGURATION OF TEST INFORMATIONS  (): All information contained in this clause and its sub-clauses is provided by the customer; the laboratory declines all responsibility for this information. 1.1 Equipment under test (EUT) The equipment under test, Configuration 1 Reference software Power supply Wireless Com. I/O Earth access EUT SMPL25AI8176 AEBWE0T0001100 0.1.21t 230 Vac 50 Hz WIFI No wired No wired 1.2 Equipment Power Supply 230 Vac 50Hz Antenna selection jumper SMA connector PCB Antenna Test report N° SPEC26AA1346_V3 Page 4/50 Internal 1.3 Equipment informations Frequency band 5180-5825 MHz Number of channels 24 Spacing channel 20 MHz Channel bandwidth 2.25 MHz PCB antenna type Microstrip antenna 1.4 Channel informations Wifi 5 GHz Channel Frequency (MHz) Low 36 5180 40 5200 44 5220 48 5240 52 5260 56 5280 60 5300 64 5320 Medium 100 5500 104 5520 108 5540 112 5560 116 5580 120 5600 124 5620 128 5640 132 5660 136 5680 140 5700 149 5745 153 5765 157 5785 161 5805 High 165 5825 Test report N° SPEC26AA1346_V3 Page 5/50 Internal 2 MEASUREMENT SETUP AND TEST DETAILS 2.1 Test arrangement and setup Measurements, in vertical and horizontal polarization, of the 3D radiation pattern of the EUT's internal PCB antenna along the X, Y, and Z axes, for 3 channels (low channel, middle channel, and high channel) in room FAR . Measurements were taken every 15° of rotation from 0° to 360° and for each position from 0° to 180° in 15° increments. 0° to 360° (step 15°) 0° to 180° (step 15°) 0° 90° 180° Test report N° SPEC26AA1346_V3 Page 6/50 Internal 0° 90° 180 ° Test report N° SPEC26AA1346_V3 Page 7/50 Internal 2.2 Photo FAR room 7 2.3 Test means Identification Description Manufacturer Reference Characteristic CEC771RF FAR room 7 SIEPEL 30MHz-26GHz RF657 Software RF ACCSYS AcEMC 7.4.8.4 CEC648 Power Sensor DARE RPR3006W 10MHz-6GHz CEC412 Horn antenna ETS LINDGREN 3115 750MHz-18GHz RF757 Cable 1.5 m ext FAR room 7 SMA 1.5 m RF759 Cable 5 m int FAR room 7 SMA 5 m 48378 Multimeter FLUKE FLUKE 45 Test report N° SPEC26AA1346_V3 Page 8/50 Internal 2.4 EUT Setup EUT SMPL25AI8176 : Power 230 Vac 50Hz / internal PCB antenna selected / Mode emission continuous EUT configuration and command for channel 036 measurements CMD Channel 036: echo "rf_test_mode=1" > /proc/mwlan/adapter0/config echo "tx_continuous=0" > /proc/mwlan/adapter0/config echo "band=1" > /proc/mwlan/adapter0/config echo "bw=0" > /proc/mwlan/adapter0/config echo "channel=36" > /proc/mwlan/adapter0/config echo "tx_power=20 2 0" > /proc/mwlan/adapter0/config echo "tx_continuous=1 1 0xAAA…

Text truncated - open the document above for the full version.

Test Report

F-Lab Site Volta : 37, Quai Paul Louis Merlin F-38050 GRENOBLE Cedex 9 Site Amplitude : 31, rue pierre Mendès France 38320 Eybens Tél. +33 (0)4 76 60 51 72 FLAB-GEN-SUP-28 v9 Test report Results N° : SPEC26AA1345_V3 RF Test Report Cancels and replaces test report number SPEC26AA1345_V2 Delivered to : Eliwell Controls srl Via Dell'Industria, 15 Zona Industriale Paludi 32016 Alpago (BL), Italy Device under test : AIR EDGE WiFi Ethernet RS485 SD 100-240V Reference : AEBWE0T0001100 Trade mark : Eliwell by SCHNEIDER ELECTRIC Manufacturer : Eliwell Controls srl Type/Nature of test : Antenna gain & pattern measurement Bluetooth Low Energy 2.4 GHz Standard : Non standard test method Date(s) of the tests : From 19/01/2026 to 20/01/2026 Place of tests : F-Lab Site Volta Gain value : U EUT (V) Channel Frequency (MHz) 2D peak Gain (dBi) 3D peak Gain (dBi) 230 Vac Low 37 2402 4.32 4.53 230 Vac Medium 17 2440 4.66 4.89 230 Vac High 39 2480 3.64 4.47 The results obtained during the tests consigned in this test report justify the above assigned characteristics stated by the manufacturer. To declare, or not, the compliance according the standard, it was not taken into account of uncertainty measurements in the test results. This document results from tests carried out on a sample. It does not prejudge the compliance of the whole manufactured products with the tested specimen. In the case of an amendment to this test report, we draw your attention to the risks of keeping obsolete version. Each new version cancels and replaces the previous one. Any expired copies must be destroyed. Any modification to this report is identified by a line in the margin. The reproduction of this test report is authorized only in the form of integral photographic facsimile. (): Information provided by the customer; the laboratory is not responsible for information provided by the customer. This report contains 50 pages Dispatch date of report: 26/03/2026 Writer Approver MICHALLET-FERRIER Lylian BOURET Loïc Technical leader Test report N° SPEC26AA1345_V3 Page 2/50 Internal SUMMARY 1 CONFIGURATION OF TEST INFORMATIONS  ................................................................................3 2 MEASUREMENT SETUP AND TEST DETAILS ..................................................................................5 3 RESULTS ............................................................................................................................................ 11 4 CURVES EIRP LOW CHANEL (2402 MHZ) ...................................................................................... 12 5 CURVES EIRP MIDLE CHANEL (2440 MHZ) ................................................................................... 24 6 CURVES EIRP HIGHT CHANEL (2480 MHZ) ................................................................................... 37 7 ANNEX 2 – VALIDITY OF TEST MEANS ......................................................................................... 50 History table Version Dated Author Description V1 12/02/2026 MICHALLET-FERRIER Lylian Initial version V2 09/03/2026 Loïc Bouret Addition a comment for explain screenshot P.8, P.9 & P.10 Adding the formula via software to the results table P.11 V3 26/03/2026 Loïc Bouret Addition conducted power measurement P.11 TEST ENGINEERS Person Title / Function Company MICHALLET-FERRIER Lylian Test engineer Schneider Electric Test report N° SPEC26AA1345_V3 Page 3/50 Internal 1 CONFIGURATION OF TEST INFORMATIONS  (): All information contained in this clause and its sub-clauses is provided by the customer; the laboratory declines all responsibility for this information. 1.1 Equipment under test (EUT) The equipment under test, Configuration 1 Reference software Power supply Wireless Com. I/O Earth access EUT SMPL25AI8176 AEBWE0T0001100 0.1.21t 230 Vac 50 Hz WIFI BLE No wired No wired 1.2 Equipment Power Supply 230 Vac 50Hz Test report N° SPEC26AA1345_V3 Page 4/50 Internal 1.3 Equipment informations Bluetooth Low Energy 2.4 GHz Frequency band 2402-2480 MHz Number of channels 40 Spacing channel 2 MHz Channel bandwidth 2.25 MHz PCB antenna type Microstrip antenna 1.4 Channel informations Bluetooth Low Energy 2.4 GHz Test report N° SPEC26AA1345_V3 Page 5/50 Internal 2 MEASUREMENT SETUP AND TEST DETAILS 2.1 Test arrangement and setup Measurements, in vertical and horizontal polarization, of the 3D radiation pattern of the EUT's internal PCB antenna along the X, Y, and Z axes, for 3 channels (low channel, middle channel, and high channel) in room FAR . Measurements were taken every 15° of rotation from 0° to 360° and for each position from 0° to 18…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nicola Filosa
[email protected]Fax: +3904371660045

Technical Contact

ELIWELL CONTROLS SRLNicola Filosa
[email protected]

Via dell Industria 15 · Alpago, 32010 · Italy

Test Firm

UL International Germany GmbHRachid Acharkaoui
[email protected]Fax: -

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz12.00 mW
215E5.26 GHz - 5.32 GHz13.00 mW
315E5.50 GHz - 5.70 GHz18.00 mW
415E5.75 GHz - 5.83 GHz20.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device supports WLAN 5GHz 20MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter