Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
May 03, 2023
Application Purpose
Original Equipment
Date of Application
May 03, 2023
Equipment Note
AURGA Viewer
Frequency Range
5745.00000000 - 5825.00000000
Company
Changsha Qisi Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Appearance 1 2 3 4 Usage USB-C Fact ory Reset LED Indicator Help Aft er booting AURGA Viewer and LED indicator blinks, insert a paper clip into the small hole on the case. Press the inner reset button for 3 seconds and release it. AURGA Viewer will enter factory reset mode and the LED indicator blinks fast, finally it automatically reboots. After AURGA Viewer boots Blinking RED: Indicates that HDMI port is not plugged or there is no video output from the port. YELLOW: Indicates that HDMI port is receiving video signals. GREEN: Indicates that HDMI port is receiving video signals and app is streaming. Blinking YELLOW: Indicates that app connects to AURGA Viewer but the HDMI port is not plugged or there is no video output from the port. Please visit https://aurga.com to get more information. Computer/Gaming Console ... Plug HDMI port and USB-C port to target video output device. If the target device doesn’t provide USB-A port, you need to prepare a standard USB-A 5V power adapter. Visit the website (https://aurga.com) and download apps from the Download page. For iOS and Android platform, please search “AURGA Viewer” from App Store/Play Store. To use the apps, please find more information from Help page on website. 1.HDMI port 2.USB-C port 3.LED indicator 4.Inner RESET button AUR GA Viewer Quick Star t Guide FCC Caution Any Changes or modi fications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3 AURGA Viewer has been tested and comply with FCC Body SAR limits at 5mm distance.

Attestation Statements

Changsha Qisi Technology Co., Ltd. Address: #10039, BLD 2, B1E1, NO. 68 Qinglan Rd Kaifu District, Changsha, Hunan Province, PRC Tel.: +86073188757118 Fax: +86073188757118 E- mail: [email protected] Date: 2023-02-28 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attestation letter Dear Sir or Madam, We, Changsha Qisi Technology Co., Ltd., declare that our product name: AURGA Viewer(model number: AVW1, FCC ID: 2AMUA-AV1), which has a module (Model: AP6256), for marketing purpose supports BLE 1M/2M, 5G Wi-Fi (Band1 & Band4, 802.11ac20/ 802.11ac40/802.11ac80), other functions have been shielded by manufacturer though software and the end user can not have the capability to activate these functions. Sincerely, Signature: Name: Phoenix Chen Title: CEO

Cover Letter(s)

SOFTWARE SECURITY DESCRIPTION

External Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF External Photos Page 1 of 4 External Photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF External Photos Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF External Photos Page 3 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF External Photos Page 4 of 4

ID Label/Location Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-RF EXHIBITA-LABEL AND LOCATION Label Label Location Information

Internal Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Internal Photos Page 1 of 4 Internal Photo Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Internal Photos Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Internal Photos Page 3 of 4 ANT Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Internal Photos Page 4 of 4

RF Exposure Info

Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503396 Web: www.atc-lab.com Version 39: 2023-01-30 Page 1 of 50 FCC SAR TEST REPORT Applicant Name : Changsha Qisi Technology Co., Ltd. Address : #10039, BLD 2, B1E1, NO. 68 Qinglan Rd Kaifu District, Changsha, Hunan Province, PRC Report Number : RA230113-02333E-SA FCC ID: 2AMUA-AV1 Test Standard (s) FCC 47 CFR part 2.1093 Sample Description Product Type: AURGA Viewer Model No.: AVW1 Multiple Model(s) No.: N/A Trade Mark: AURGA Date Received: 2023/04/13 Date of Test: 2023/04/17 Report Date: 2023/04/21 Test Result: Pass* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Lance Li Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Version 39: 2023-01-30 Page 2 of 50 FCC SAR Attestation of Test Results EUT Information EUT Description AURGA Viewer Tested Model AVW1 Multiple Model(s) No.: N/A Trade Mark AURGA FCC ID: 2AMUA-AV1 Serial Number 24KH_1 Test Date 2023/04/17 MODE Max. SAR Level(s) Reported(W/kg) Limit (W/kg) 5.2G Wi-Fi 1g Body SAR 0.72 1.6 5.8G Wi-Fi 1g Body SAR 0.21 BLE 1g Body SAR 0.04 Simultaneous 1g Body SAR N/A Applicable Standards FCC 47 CFR part 2.1093 Radiofrequency radiation exposure evaluation: portable devices RF Exposure Procedures: TCB Workshop IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) KDB procedures KDB 447498 D04 Interim General RF Exposure Guidance v01 KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB 865664 D02 RF Exposure Reporting v01r02 KDB 447498 D02 SAR Procedures for Dongle Xmtr v02r01. Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Version 39: 2023-01-30 Page 3 of 50 FCC SAR TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 EUT DESCRIPTION ................................................................................................................................................... 5 TECHNICAL SPECIFICATION ............................................................................................................................................. 5 REFERENCE, STANDARDS, AND GUIDELINES ................................................................................................. 6 SAR LIMITS ..................................................................................................................................................................... 6 FACILITIES ................................................................................................................................................................. 7 DESCRIPTION OF TEST SYSTEM .......................................................................................................................... 8 EQUIPMENT LIST AND CALIBRATION ............................................................................................................. 14 EQUIPMENTS LIST & CALIBRATION INFORMATION ........................................................................................................ 14 SAR MEASUREMENT SYSTEM VERIFICATION ............................................................................................. 15 LIQUID VERIFICATION ................................................................................................................................................... 15 SYSTEM ACCURACY VERIFICATION ............................................................................................................................... 16 SAR SYSTEM VALIDATION DATA ......................................................................................................................... 17 EUT TEST STRATEGY AND METHODOLOGY ................................................................................................. 20 SIMPLE DONGLE PROCEDURES ............................................................................................................................ 20 TEST DISTANCE FOR SAR EVALUATION ........................................................................................................................ 20 SAR EVALUATION PROCEDURE ...…

Text truncated - open the document above for the full version.

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 1 of 23 APPENDIX C PROBE CALIBRATION CERTIFICATES Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 2 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 3 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 4 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 5 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 6 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 7 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 8 of 23

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 9 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 10 of 23 APPENDIX D DIPOLE CALIBRATION CERTIFICATES Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 11 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 12 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 13 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 14 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 15 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 16 of 23

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 17 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 18 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 19 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 20 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 21 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 22 of 23 Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-SA Page 23 of 23

Test Report

版本修訂者修訂頁次修訂內容申請日期生效日期 黃啟傑正式發行 林豪建 、、、尺 寸圖面修正標示、新增 放置圖示 新增 SymbolSpec. Po4.00±0.1 P18.00±0.1 P22.00±0.05 Do1.55±0.05 D11.50(MIN) E1.75±0.1 F5.50±0.05 10Po40.00±0.2 W12.00±0.1 T0.25±0.05 ± ± ± °

Test Report

Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503396 Web: www.atc-lab.com Version 10: 2021-11-09 Page 1 of 55 FCC- 5G Wi-Fi TEST REPORT Applicant Name : Changsha Qisi Technology Co., Ltd. Address : #10039, BLD 2, B1E1, NO. 68 Qinglan Rd Kaifu District, Changsha, Hunan Province, PRC Report Number : RA230113-02333E-RF-00B FCC ID: 2AMUA-AV1 Test Standard (s) FCC PART 15.407 Sample Description Product: AURGA Viewer Tested Model: AVW1 Trade Name: AURGA Date Received: 2023-01-13 Date of Test 2023-02-03 to 2023-02-06 Report Date: 2023-02-16 Test Result: PASS* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Roger.Ling Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230113-02333E-RF-00B Version 10: 2021-11-09 Page 2 of 55 FCC- 5G Wi-Fi TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC §1.1307(b)&§2.1093 - RF EXPOSURE ............................................................................................................. 12 FCC §15.203 – ANTENNA REQUIREMENT .......................................................................................................... 13 APPLICABLE STANDARD ............................................................................................................................................ 13 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 13 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 14 APPLICABLE STANDARD ............................................................................................................................................ 14 EUT SETUP ................................................................................................................................................................ 14 EMI TEST RECEIVER SETUP ....................................................................................................................................... 14 TEST PROCEDURE ...................................................................................................................................................... 15 FACTOR & MARGIN CALCULATION ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Test Photos Page 1 of 3 Photo of Power Line Conducted Emission Measurement Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Test Photos Page 2 of 3 Radiated Spurious Emissions Test View (Below 1GHz) Shenzhen Accurate Technology Co., Ltd. Project No.: RA230113-02333E-RF Test Photos Page 3 of 3 Radiated Spurious Emissions Test View (Above 1GHz)

Contact Information

Applicant

Phoenix Chen
[email protected]+86073185522537Fax: +86073185522537

Test Firm

Shenzhen Accurate Technology Co., Ltd.Lisa Zhang
[email protected]+86-755-26503290

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz40.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. SAR compliance has been established for direct laptop and HDMI cable plug-in configurations with a separation distance of 5 mm between the dongle and flat phantom. This device was tested for SAR compliance for use in notebook computers with connector configurations as described in this filing, and can be used with notebook computers with the same operating configurations and exposure conditions, with only minor configuration and construction differences. Compliance of this device in all final host configurations is the responsibility of the Grantee. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product guidelines. The highest reported body SAR is 0.72 W/Kg.