FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Duracell U.S. Operations, Inc./
  3. 2AMUD-M100

2AMUD-M100Portable Power Station

Duracell U.S. Operations, Inc.
Portable Power Station - FCC ID 2AMUD-M100 - Duracell U.S. Operations, Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 17, 2024
Application Purpose
Original Equipment
Date of Application
Jul 16, 2024
Equipment Note
Portable Power Station
Frequency Range
0.11010000 - 0.20500000
Company
Duracell U.S. Operations, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Duracell PortablePowerStation M100 2 UserManual IMPORTANTSAFETYINFORMATION 1.ReadalltheinstructionsbeforeusingtheDuracellM250(HereinafterreferredtoasUnit). 2.Toreducetheriskofinjury,closesupervisionisnecessarywhentheUnitisusednearchildren. 3.DonotexposetheUnittorainorsnoworusetheunitwhenlighteningisexpectedorpresent.Donot placetheUnitindirectsunlight.OnlyplacetheUnitinclean,dryplaces. 4.UseonlyrecommendedDuracellaccessoriesandchargers. 5.DonotexposetheUnittofireorexcessivetemperature.Anysuchexposuretofireortemperature above140°F(60°C)maycauseanexplosion.Donotusenearflammablegasesorfumes. 6.DonotusetheUnitwithdamagedwiresorplugs. 7.DonotusetheUnitifitisdamagedormodified.DamageormodificationoftheUnit,includingthe lithium-ionbatterypackwithintheUnit,mayexhibitunpredictablebehaviourresultinginfire, explosionorriskofinjury. 8.MakesuretousetheUnitinaventilatedenvironment.DonotrestricttheventilationoftheUnitinany wayduringusage. 9.Duringstorage,keeptheUnitinadryandventilatedplacetoavoidmoistureandelectricshock. 10.ThisUnithasnoserviceableparts. 11.Donotdisassemble,repair,ormodifytheUnit.Itmaycausefire,explosion,injury,andunpredictable risks. 12.Donotremovepowercablesbypullingonthecableitself,asitmayfrayandcauseashortcircuit. Cablesshouldbeproperlyremovedbyholdingtheirconnectorsandpulling. 13.Donotputcoins,metalcreditcards,oranyothermetalobjectsbetweenyourphoneandthetiltable lidduringwirelesscharging. 14.ACoutputisSimulated/Quasi/modifiedSinusoidalACWaveform,Seethebelowcautionstatement beforeconnectingtheappliancestotheunit. 15.Pleasevisitwww.duracell.comorcallDuracellConsumerRelationsat800-551-2355ifyouexperience anyproblemswiththeUnit. Ifinstructionsarenotfollowed,itcancausehospitalization,seriousinjury,ordeath.Seriousinjuriesinclude blindness,burns,electricshock,etc.,leadingtocomplications. 3 WARNINGANDHAZARDTYPES ELECTRICSHOCKHAZARD DonotsubjecttheUnittomechanicalshock.Keepawayfromchildren.TheUnitgeneratesthesame potentiallylethal120VACpowerasastandardhouseholdwalloutlet.Toreducetheriskoffireor electricshock,donotopentheenclosureorexposetheUnittorainormoisture.Donotinsertforeign objectsintotheACconnectionortheventilationholes.AllUSBandACplugsmustbeappropriately insertedandavoidusingdamagedcables.Donotoperateoutsideofitsoperatingtemperaturerangeof 4°Cto40°C. FIREHAZARD DonotburnorincineratetheUnit.ExposingtheUnittoheatorfiremaycauseanexplosionand personalinjuryordamage.Donotusenearflammablegasesorfumesorapparatusthatproduceslarge amountsofheat. APPLIANCECAUTIONS(forSimulated/Quasi/ModifiedSinusoidalACWaveform): TheUnit’sACoutputisa100W120V/60HzmodifiedSinusoidalwaveintendedforchargingofportable electronicsdevicessuchasLaptops,Tablets,andMobilephones. TheACoutputcanalsobeusedforsmallfansandlightsandchargingofotherportableelectronic devices. SomefanswithsynchronousmotorsmaycreatenoisewhenpoweredbyamodifiedSinusoidal WaveformACvoltage. SomedevicesrequireapureSinusoidalwaveACoutputandcanbedamagedbyamodifiedSinusoidal wave,pleasecheckthemanufacturersrecommendation.Devicesratedmorethan100Wwillnot functionsuchas-Toaster,Coffeemaker,Refrigerator,HairDryeretc. DONOTplugsmallappliancesintotheUnit’sACreceptacletodirectlyrechargetheirnickel-metal hydridebatteries. DONOTuseamodifiedSinusoidalWaveformACvoltagewiththebelowtwotypesofequipmentor applianceswhicharesusceptibletodamage :  Small,battery-operatedappliancessuchasflashlights,cordlessrazorsandtoothbrushes thatcanbepluggeddirectlyintoanACreceptacletorecharge.  Certainbatterychargersforbatterypacksthatareusedinsomecordlesshand-tools. Chargersforthesetoolshaveawarninglabelstatingthatdangerousvoltagesarepresentat thebatteryterminals. 4 DISPOSALANDRECYCLING RecycletheUnitresponsiblyandaccordingtolocal,state,andnationalregulationsapplicabletolithium- ionrechargeablebatteries. FCCSTATEMENT ThisdevicecomplieswithPart15oftheFCCRulesandClassBDigitalDevicelimitswhichprovide protectionagainstinterferenceinaresidentialinstallation.Operationissubjecttothefollowingtwo conditions: (1)thisdevicemaynotcauseharmfulinterference (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation. Thisdevicegenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseinterferencetoradio/TVcommunicationsforwhichthe manufacturerisnotresponsible.Shouldinterferenceoccur,correctbyconnectingthedevicetoanother outletonadifferentcircuit. WARRANTYINFORMATION Duracelloversa24-monthlimitedwarrantyfromthedateofpurchase.Keepacopyofyourpurchase receiptasproofofpurchase.Ourproduct’swarrantyislimitedonlytotheUnititselfwhenused normallyinaccordancewiththeoperatinginstructionsandthesystemenvironment.Thecustomer acknowledgesandagreesthat: •Duracellisnotliablefordamageorlossresultingfromtheuseofthisproductorforanyclaimfroma thirdparty. •Duracellisnotliableforproblemswithanyelectronicdevicesorhomeappliancesoranyother hardwarearisingfromtheuseofthisproduct,thesuitabilityoftheproductforspecifichardware, software,orperipherals,operatingconflictswithotherinstalledsoftware,dataloss,orother accidentalorunavoidabledamages. •Duracellisnotliablefor_financialdamages,lostproducts,claimsfromthirdparties,etc.,arisingfrom theuseofthisproduct. FormoreinformationregardingourProductline,customerServiceandwarrantyinformationplease contactDuracellConsumerRelationsat800-551-2355orvisitourwebsite:www.duracell.com. 5 INFORMATIONSDESÉCURITÉIMPORTANTES 1.Liseztouteslesinstructionsavantd'utiliserleDuracellM150(ci-aprèsdénommél'unité). 2.Pourréduirelerisquedeblessure,unesurveillanceétroiteestnécessairelorsquel'appareilest utiliséàproximitéd'enfants. 3.N'exposezpasl'appareilàlapluieouàlaneigeetn'utilisezpasl'appareillorsquelafoudreest attendueouprésente.Neplacezpasl'appareilàlalumièredirectedusoleil.Placezl'appareil uniquementdansdesendroitspropresetsecs. 4.UtilisezuniquementlesaccessoiresetchargeursDuracellrecommandés. 5.N'exposezpasl'appareilaufeuouàunetempératureexcessive.Unetelleexpositionaufeuouà unetempératuresupérieureà140°F…

Text truncated - open the document above for the full version.

Attestation Statements

Duracell U.S. Operations, Inc. Berkshire Corporate Park 14 Research Drive Bethel Connecticut 06801 United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-4 To whom it may concern: We, Duracell U.S. Operations, Inc., hereby certify that the equipment for which authorization is sought (FCC ID: 2AMUD-M100) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Laura Zadrick NA Regulatory Manager Duracell U.S. Operations, Inc. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03

Attestation Statements

DuracellU.S.Operations,Inc. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 7/2/24 U.S.AgentDesignation DuracellU.S.Operations,Inc.acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStates toactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2AMUD- M100): NameandcompanyofU.S.agent:DuracellU.S.Operations,Inc. PhysicalU.S.addressofagent:BerkshireCorporatePark14ResearchDriveBethelConnecticut 06801UnitedStates FRNofU.S.agent:0025298753 EmailaddressofU.S.agent:[email protected] DuracellU.S.Operations,Inc.acknowledgestheirobligationtoacceptserviceofprocessonbehalfofDuracell U.S.Operations,Inc.. DuracellU.S.Operations,Inc.withtheFRN0025298753acceptsitsobligationtomaintainanagentforservice ofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature LauraZadrick NARegulatoryManager DuracellU.S.Operations,Inc. Signature LauraZadrick NARegulatoryManager DuracellU.S.Operations,Inc. 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-7-4> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AMUD-M100 MCA92W-055Wh For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Laura Zadrick/NA Regulatory Manager Company: Duracell U.S. Operations, Inc. Address: Berkshire Corporate Park 14 Research Drive Bethel Connecticut 06801 United States Phone: 2037316427 Fax: E-Mail: [email protected]

Cover Letter(s)

Duracell U.S. Operations, Inc. Berkshire Corporate Park 14 Research Drive Bethel Connecticut 06801 United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-7-4 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AMUD-M100 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Laura Zadrick/NA Regulatory Manager Company: Duracell U.S. Operations, Inc. Address: Berkshire Corporate Park 14 Research Drive Bethel Connecticut 06801 United States Phone: 2037316427 Fax: E-Mail: [email protected]

External Photos

Page1of4FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Page2of4FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.2 Fig.3 Page3of4FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.4 Fig.5 Page4of4FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.6

ID Label/Location Info

Page1of2FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION Thelabelisprintedontheproductbymeansofradiumengraving Page2of2FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LabelLocation

Internal Photos

Page1of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 PhoneCoil Page5of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13 Fig.14 Page8of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.15 Fig.16 EarphoneCoil Page9of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.17 Fig.18 Page10of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.19 Fig.20 Page11of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.21 Fig.22 Page12of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.23 Fig.24 Page13of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.25 Fig.26 Page14of14FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BuildingAand301BuildingC,JujiIndustrialPark,YabianxueziweiShajingStreet,BaoanDistrict, Shenzhen,518000,P.R.C. Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.27 ----------------- THEENDOFTESTREPORT -----------------

RF Exposure Info

Page1of15FCCID:2AMUD-M100ReportNo.:LCSA04154028EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2AMUD-M100 ProductNamePortablePowerStation ModelNumberMCA92W-055Wh PowerSupply DockInput:24V2.5A,60WMax.Totaloutput:92WMax. USB-CInput:5V3A,9V3A,12V3A,15V2.4A,20V1.8A (Input:36WMax.) USB-COutput:5V3A(8400mAh),9V3A(4800mAh), 12V3A(3800mAh),15V3A(2900mAh),20V3A(1500mAh). USB-AOutput:5V2.4A(8000mAh) Wirelesscharger,output1:15WMax.,output2:5WMax. ModulationTypeASK FrequencyRange110.1~205.0KHz AntennaTypeCoilAntenna HardwareversionV1.6 SoftwareversionV1.3 Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)WirelesspowertransferdevicesmustcomplywithRFexposurerequirementsforalldesign configurationsinwhichtheycanoperate.Ataminimum,RFexposuremustbeevaluatedforthe worst-casescenario,typicallywhenthetransmitter,whiledeliveringenergytoaclientdevice,is operatingatmaximumoutputpower.RFexposurecomplianceforequipmentauthorization mustbedeterminedfollowingtheguidanceofKDB447498,whichincludesconsiderationofthe differenttestrequirementsforMobileDeviceandPortableDeviceexposurecategories,as definedin§§2.1091and2.1093oftheRules. 2)TheRFexposurelimits,assetforthin§1.1310,donotcoverthefrequencyrangebelow100 kHzforSpecificAbsorptionRate(SAR)andbelow300kHzforMaximumPermittedExposure (MPE).Inaddition,presentlimitationsofRFexposureevaluationsystemspreventanaccurate evaluationofSARbelow4MHz.Forthesereasons,aspecificMPE-basedRFExposure complianceprocedurefordevicesoperatingintheaforementionedlow-frequencyrangeshas beensetinplace.ThisprocedureisapplicabletoEquipmentAuthorizationofallRFdevices, thusincluding,butnotlimitedto,Part18andWPTdevices.Accordingly,for§2.1091-Mobile devices,theMPElimitsbetween100kHzto300kHzaretobeconsideredthesameasthoseat 300kHzinTable1of§1.1310,thatis,614V/mand1.63A/m,fortheelectricfieldandmagnetic field,respectively.For§2.1093-Portabledevicesbelow4MHzanddownto100kHz,theMPE limitsin§1.1310(withthe300kHzlimitapplicableallthewaydownto100kHz)canbeusedfor thepurposeofequipmentauthorizationinlieuofSARevaluations. Page2of15FCCID:2AMUD-M100ReportNo.:LCSA04154028EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Furthermore,consistentwithFCC’sequipmentauthorizationRFexposureguidance,anydevice (bothportableandmobile)operatingatfrequenciesbelow100kHzisconsideredcompliantforthe purposeofequipmentauthorizationwhentheexternal(unperturbed)temporalpeakfieldstrengths donotexceedthefollowingreferencelevels: 83V/mfortheelectricfieldstrength(E) and90A/mforthemagneticfieldstrength(H) Thesedatamaybeprovidedthroughmeasurementsand/ornumericalsimulations,andforallthe positionsinspacerelevantforanypossiblebodyexposure. 3)“Largesize”probesmaypreventthemeasurementofE-and/orH-fieldsnearthesurfaceofthe radiatingstructure(e.g.,aWPTsourcecoil),asintheexampleshowninFigure1. Ifthecenteroftheprobesensingelementislocatedmorethan5mmfromtheprobeoutersurface, thefieldstrengthsneedtobeestimatedthroughmodelingforthosepositionsthatarenotreachable. Theestimatesmaybedoneeithervianumericalcalculation,orviaanalyticmodel:e.g., approximatedformulasforcircularcoils,dipoles,etc.,maybeacceptableifitisshownthatthe modelisapplicableforthedesignparametersconsidered.Atypicalexampleistheuseofa quasi-staticapproximationformulaforalow-frequencymagneticfieldsource.Theseestimatesshall includepointsspacednomorethan2cmfromeachother.Thus,intheexampleof Figure1,atleasttheestimatesat0cm2and2cmarerequired,whileonlyonepointwouldnotbe sufficient.Inaddition,themodelneedstobevalidatedthroughtheprobemeasurementsforthetwo closestpointstothedevicesurface,andwith2-cmincrements,asindicatedinFigure1.Inthat example,thesamemodelmustalsobeappliedtothe4cmand6cmpositions,andthencompared withthemeasureddata,forvalidationpurposes.Thevalidationisconsideredsufficientifa30% agreementbetweenthemodelandthe(E-and/orH-field)probemeasurementsisdemonstrated.If suchalevelofagreementcannotbeshown,amoreaccuratemodel(and/orasmallerprobe)shall beused. 4)Part18WirelessPowerTransferuptoOne-MeterDistance.ThissectionappliesonlytoWPT transmittersthat,bydesign,canprovidepowertoaloadlocatedatadistancenogreaterthan onemeter.Thisdistanceshallbemeasuredbetweentheclosestpointsbetweenthetransmitter andthereceiverenclosuresurfaces.Forinstance,twocoilspositionedasinFigure2-amaybe operatedandconsideredundertheprovisionsofthissection,becausebothreceiversarewithin one-meterdistancefromthetransmitter.However,thecaseinFigure2-bcannotbeconsidered Page3of15FCCID:2AMUD-M100ReportNo.:LCSA04154028EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity inthesameway,anditistreatedaccordingtotheprescriptionofSection5.3. ForWPTdesignswithmorethanoneradiatingstructurethedistancetotheloadshallbe consideredasinFigure3,thusmeasuredbetweenthereceiverandtheclosesttransmitting structure. TheremightbesituationswheretheWPTRFemissionsarelimitedenoughthatevenoperationsin a“crowded”environment,wheremanysimilarWPTdevicesarepresent,donotposesignificant EMCandRFexposureconcerns.Inthisscenario,andfordevicesoperatingwithinaone-meter Page4of15FCCID:2AMUD-M100ReportNo.:LCSA04154028EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82…

Text truncated - open the document above for the full version.

Test Report

Coil Antenna:0dBi(max)

Test Report

Coil Antenna:0dBi(max)

Test Report

Page 1 of 28 FCCID:2AMUD-M100ReportNo.:LCSA04154028EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For DuracellU.S.Operations,Inc. PortablePowerStation TestModel:MCA92W-055Wh Preparedfor:DuracellU.S.Operations,Inc. Address: BerkshireCorporatePark14ResearchDrive.Bethel.CT06801 Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:April15,2024 Numberoftestedsamples:2 SampleNo.:A240415039-1,A240415039-2 Serialnumber:Prototype DateofTest:April15,2024~April27,2024 DateofReport: April28,2024 Page 2 of 28 FCCID:2AMUD-M100ReportNo.:LCSA04154028EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA04154028EA DateOfIssue......................................:April28,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:DuracellU.S.Operations,Inc. Address................................................:BerkshireCorporatePark14ResearchDrive.Bethel.CT06801 TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:PortablePowerStation TradeMark..........................................: TestModel...........................................: MCA92W-055Wh PowerSupply......................................: DockInput:24V2.5A,60WMax.Totaloutput:92WMax. USB-CInput:5V3A,9V3A,12V3A,15V2.4A, 20V1.8A(Input:36WMax.) USB-COutput:5V3A(8400mAh),9V3A(4800mAh), 12V3A(3800mAh),15V3A(2900mAh), 20V3A(1500mAh). USB-AOutput:5V2.4A(8000mAh) Wirelesscharger,output1:15WMax.,output2:5WMax. Result..................................................:Positive Compiledby:Supervisedby:Approvedby: LingZhu/Administrator CaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 28 FCCID:2AMUD-M100ReportNo.:LCSA04154028EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA04154028EA April28,2024 Dateofissue TestModel..........................:MCA92W-055Wh EUT....................................:PortablePowerStation Applicant...........................:DuracellU.S.Operations,Inc. Address..............................: BerkshireCorporatePark14ResearchDrive.Bethel.CT 06801 Telephone..........................:/ Fax.....................................:/ Manufacturer.....................:NanChangInnotechInternationalCo.,Ltd. Address..............................: Building6GuoweiIndustrialPark,No.669HuangtangE Rd,LinkongEconomicZone,Nanchang,Jiangxi Telephone..........................:/ Fax.....................................:/ Factory..............................:NanChangInnotechInternationalCo.,Ltd. Address..............................: Building6GuoweiIndustrialPark,No.669HuangtangE Rd,LinkongEconomicZone,Nanchang,Jiangxi Telephone..........................:/ Fax.....................................:/ Page 4 of 28 FCCID:2AMUD-M100ReportNo.:LCSA04154028EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000April28,2024InitialIssue--- Page 5 of 28 FCCID:2AMUD-M100ReportNo.:LCSA04154028EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.......................................................................................6 1.1DescriptionofDevice(EUT)..............................................................................................6 1.2SupportequipmentList......................................................................................................6 1.3ExternalI/OCable...................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2AMUD-M100 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:webmaster@lcs-cert.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Laura Zadrick
[email protected]2037316427Fax: none

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1101 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498.