Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
正面 反面 5 2.Select “Set up device” from the menu 3.Click on “Have something already set up?” 4.Search for “smart life” and select it from the list 5.Login to your Smart Life account 6.Authorize your account to link with Google Home. You are now able to control your smart socket with Google Home App or Speaker. You could also follow the optional steps in Google Home App to group and organize your smart devices. But those are not required. After-sales Policy: Thank you very much for purchasing POWRUI products! Like what you just got?Help us by writing a feedback on Amazon and telling your friends and family. Work with Google Home 1.Open the Google Home App and click on “+” Add sign. After these initial setup steps, new devices you add to Smart Life App in later times will be linked to Google Home App automatically. You will not have to manually link them again. After the device is added, there will be five symbols on Google Home App, one for the device and 4 for individual switches. You could turn on/off each of them by voice using Google Home. After the device is added, there will be several symbols on Google Home App, one for the device and a few for individual switches. You could turn on/off each of them by voice using Google Home. After the device is added, there will be several symbols on Amazon Alexa App, one for the device and a few for individual switches. You could turn on/off each of them by voice using Alexa. 3.3) "Adding device"page and wait for the device to be searched.If the WiFi indicator is not flashing quickly, please follow the steps of "Reset the device" in the app to operate, then select "Next" to enter "Adding device" and wait for the device to be searched. At this time, confirm that the WiFi indicator is flashing rapidly, and directly select "Next" in the "Reset the device" step to enter 3.4) After the device is found, click "+" to add the desired device, and then select "Done" to return to the device control interface. Once connected, you can turn on/off and schedule and countdown from your phone. Work with Amazon Alexa 1.Open the Alexa App and click on “Skills & Games” in the menu. 3.click on “ENABLE TO USE” 2.Search for “smart life” 4.Login to your Smart Life account 5.Authorize your account to link with Amazon Alexa. Click on “DISCOVER DEVICES”. When it finishes discovering, you will be able to control your smart socket with Amazon Alexa App, Echo or Echo Dot. You could also follow the optional steps in Amazon Alexa App to group and organize your smart devices. But those are not required. After these initial setup steps, new devices you add to Smart Life App in later times will be linked to Amazon Alexa App automatically. You will not have to manually link them again. After the device is added, there will be five symbols on Amazon Alexa App, one for the device and 4 for individual switches. You could turn on/off each of them by voice using Alexa. 1)Sign Up 1. Click "create new account" to enter User Agreement and Privacy Policy page, click” agree”, to get to the registration page. 4. After that to set up your password and click "finish", Registration completed successfully. 3.Input your phone number or email addressto “get verification code" and input the verification code. 2. The system detects the current country / place automatically. You can also select the country / place manually. Part 1 Download the app : Part 2 Sign up/Log in/ Retrieve password : Search APP "Smart Life" from App store or Google Play, download and install the APP onto your smart devices. Forget the password to Retrieve password 1. click "forget passwor d", as shown in Figure For the number or email, click "get verification code", as shown in the figure below. 2. The system detects the current country / place automatically. Or you can select the country / place manually. If you forget the password of APP account login, you can access Reset account password after password recovery process 3. Input the verification code received by mobile phone or email, as shown in Figure below. 4.Enter the new password and click "finish" to log in, as shown in the figure below. 3.1) After logging in, plug the device into the electrical outlet, click "+" on the upper right corner on the app home page then select "add device" from the menu. 3.2) Select "Electrical", click "Socket (WI-FI)", then select the 2.4G network with strong signal in the working area, enter the password, and click "Next. Part 3 Add device : 2)Log in 1. the system automatically detects the current country / region, you can also manually select country / region. 2. Enter your registered mobile phone number or email and password, then log in to the system with the steps shown as below. If you have registered an app account already, click “Log in “, with the account to the Logging in page. 3) Parameters 125VAC,60Hz 15A,1875W Model: Power: Load Current: 2.4G 802.11 b/g/nWiFi Standard: AHR-087 Applicable Voltage Range:100-240VAC Smart Wi-Fi Power Strip Smart USB 4.8A TOTAL Phone holder Branch Outlet indication Light Individual Outlets WIFI switch Alternative Fixed Screw Wifi / Reset Model: AHR-087 尺寸:105x148.5mm,黑白印刷 3 AC outlets built-in 540 joules of surge protection
FCC Caution. § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated withminimum distan ce 20cm between the radiator & your body.
Shenzhen Anhaoruihe Electronics Co Ltd 7/5/2022 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Current taps with class 2 power unit / AND FCC ID: 2AMXX-AHR-087 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : XINHE CHEN/ President Contact information / address: 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103
Shenzhen Anhaoruihe Electronics Co Ltd 7/5/2022 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTA Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : XINHE CHEN/ President Contact information / address: 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103
FCC ID: 2AMXX-AHR-087 AHR-087 External Photos of the EUT Photo 1 Photo 2 Photo 3 FCC ID: 2AMXX-AHR-087 Photo 4 Photo 5 Photo 6
2.1*4.3cm
FCC ID: 2AMXX-AHR-087 AHR-087 Internal Photos of the EUT Photo 1 Photo 2 Photo 3 FCC ID: 2AMXX-AHR-087 Photo 4 Photo 5 2.4G WIFI/BLE Antenna
RF Exposure evaluation FCC ID: 2AMXX-AHR-087 Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Antenna Information Briller can only use antennas certificated as follows provided by manufacturer; Antenna No. Model No. of antenna: Type of antenna: Gain of the antenna (Max.) Frequency range: BLE / PCBANT 0.00dBi for 2400-2500MHz; 2.4GWIFI / FPC ANT 0.00dBi for 2400-2500MHz for ANT 1&2 5. Manufacturing Tolerance [BLE] GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 0.0 0.0 1.0 Tolerance ±(dB) 1.0 1.0 1.0 [2.4GHz WLAN] ANT IEEE 802.11b (Average) Frequency (MHz) 2412 2437 2462 Target (dBm) 12.0 12.0 12.0 Tolerance ± (dB) 1.0 1.0 1.0 IEEE 802.11g (Average) Frequency (MHz) 2412 2437 2462 Target (dBm) 9.0 9.0 9.0 Tolerance ± (dB) 1.0 1.0 1.0 IEEE 802.11n HT20 (Average) Frequency (MHz) 2412 2437 2462 Target (dBm) 9.0 9.0 9.0 Tolerance ± (dB) 1.0 1.0 1.0 6. Standalone MPE Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna is 0.0dBi, the RF power density can be obtained. Modulation Type Output power Antenna Gain (dBi) Antenna Gain (linear) MPE (mW/cm 2 ) MPE Limits (mW/cm 2 ) dBm mW BLE 2.0 1.58 0.0 1.000 0.0003 1.0000 2.4GWIFI ANT 13.0 19.95 0.0 1.000 0.004 1.0000 Remark: 1. Output power (Peak) including turn-up tolerance; 2. MPE evaluate distance is 20cm from user manual provide by manufacturer. 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID............................................. : CTA22062800201 2AMXX-AHR-087 Compiled by ( position+printed name+signature) . : File administrators Kevin Liu Supervised by ( position+printed name+signature) . : Project Engineer Kevin Liu Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jun. 30, 2022 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Anhaoruihe Electronics Co Ltd Address ............................................ : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Test specification ........................... : Standard ........................................... : FCC Part 15.247 TRF Originator .................................. : Shenzhen CTA Testing Technology Co., Ltd. Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Current taps with class 2 power unit Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Anhaoruihe Electronics Co., Ltd Model/Type reference ...................... : AHR-087 Listed Models .................................. : AHR-085, AHR-077 Modulation Type ............................... : CCK/DSSS/ OFDM Operation Frequency ........................ : From 2412 - 2462MHz Rating ............................................... : AC 120V/60Hz Result ............................................... : PASS Report No.: CTA22062800201 Page 2 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Current taps with class 2 power unit Model /Type : AHR-087 Series Model No. AHR-085, AHR-077 Applicant : Shenzhen Anhaoruihe Electronics Co Ltd Address : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Manufacturer : Shenzhen Anhaoruihe Electronics Co Ltd Address : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA22062800201 Page 3 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 5 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Test Description 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 10 4.1 AC Power Conducted Emission 10 4.2 Radiated Emission 13 4.3 Maximum Peak Conducted Output Power 20 4.4 Power Spectral Density 21 4.5 6dB Bandwidth 24 4.6 Out-of-band Emissions 27 4.7 Antenna Requirement 34 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 35 6 P H O T O S O F T H E E U T ........................................................... 36 Report No.: CTA22062800201 Page 4 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 v05r02: Guidance for Compliance Measurements on Digital Transmission Systems (DTS) ,Frequency Hopping Spread Spectrum System(HFSS), and Hybrid System Devices Operating Under §15.247 of The FCC rules. Report No.: CTA22062800201 Page 5 of…
Text truncated - open the document above for the full version.
Report No.: CTA22062800201 Page 29 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 802.11b 802.11g Reference Reference CH011 CH01 30MHz-3GHz 30MHz-3GHz 3GHz -25GHz 3GHz -25GHz Report No.: CTA22062800201 Page 30 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 802.11g Reference Reference CH06 CH11 30MHz-3GHz 30MHz-3GHz 3GHz -25GHz 3GHz -25GHz Report No.: CTA22062800201 Page 31 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 802.11n20 Reference Reference CH01 CH06 30MHz-3GHz 30MHz-3GHz 3GHz -25GHz 3GHz -25GHz Report No.: CTA22062800201 Page 32 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 802.11n20 Reference CH11 30MHz-3GHz 3GHz -25GHz Report No.: CTA22062800201 Page 33 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Band-edge Measurements for RF Conducted Emissions: 802.11b Left bandedge Right bandedge 802.11g Left bandedge Right bandedge 802.11n(HT20) Left bandedge Right bandedge Report No.: CTA22062800201 Page 34 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 4.7 Antenna Requirement Standard Applicable For intentional device, according to FCC 47 CFR Section 15.203: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1) (I): (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi. Test Result: The maximum gain of antenna was 0.00 dBi. Remark:The antenna gain is provided by the customer , if the data provided by the customer is not accurate, Shenzhen CTA Testing Technology Co., Ltd. does not assume any responsibility. Report No.: CTA22062800201 Page 35 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 5 T e s t S e t u p P h o t o s o f t h e E U T Report No.: CTA22062800201 Page 36 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 6 P h o t o s o f t h e E U T Report No.: CTA22062800201 Page 37 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA22062800201 Page 38 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA22062800201 Page 39 of 39 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn ********************** End of Report **********************
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID. ............................................ : CTA22062800202 2AMXX-AHR-087 Compiled by ( position+printed name+signature) .. : File administrators Kevin Liu Supervised by ( position+printed name+signature) .. : Project Engineer Kevin Liu Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Jun. 30, 2022 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Anhaoruihe Electronics Co Ltd Address ............................................ : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Test specification ...........................: Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description...................: Current taps with class 2 power unit Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Anhaoruihe Electronics Co., Ltd Model/Type reference....................... : AHR-087 Listed Models .................................. : AHR-085, AHR-077 Modulation ....................................... : GFSK Frequency .......................................... From 2402MHz to 2480MHz Ratings ............................................. : AC 120V/60Hz Result................................................ : PASS Report No.: CTA22062800202 Page 2 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Current taps with class 2 power unit Model /Type : AHR-087 Listed Models : AHR-085, AHR-077 Applicant : Shenzhen Anhaoruihe Electronics Co Ltd Address : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Manufacturer : Shenzhen Anhaoruihe Electronics Co Ltd Address : 2 Building Anhaorui industrial Park Jianan Road Tangwei Fuyong Town Baoan Dist. Shenzhen, Guangdong, China, 518103 Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA22062800202 Page 3 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Related Submittal(s) / Grant (s) 6 2.8 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 10 4.1 AC Power Conducted Emission 10 4.2 Radiated Emissions and Band Edge 13 4.3 Maximum Peak Output Power 20 4.4 Power Spectral Density 21 4.5 6dB Bandwidth 23 4.6 Out-of-band Emissions 25 4.7 Antenna Requirement 29 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 30 6 P H O T O S O F T H E E U T ........................................................... 31 Report No.: CTA22062800202 Page 4 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 V05r02: Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating Under §15.247 Report No.: CTA22062800202 Page 5 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, C…
Text truncated - open the document above for the full version.
FCC ID: 2AMXX-AHR-087 AHR-087 Test Setup Photos of the EUT conduction radiation L Radiation H
Room 106, Building 1, Yibaolai Ind. Park · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 1.37 mW |
Relocatable Power Tap
Equipment Class
DTS - Digital Transmission System