Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MADE IN CHINA Rev_ 1.1 Video Baby Monitor USER GUIDE 2.8"/ 3.2" LCD EN/ DE/ FR/ ES/ IT/ DA/ CS/ PL/ NL/ SV/ EL/ HU/ RU CONTENTS SAFETY INSTRUCTIONS CAUTION PACKAGE CONTENTS PRODUCT DIAGRAM GETTING STARTED 1. Charging & Powering Monitor 2. Powering Camera 3. Placing the Camera FUNCTIONS & OPERATIONS Top Status Indications Notification Icons Bottom Menu Brief 1. Brightness & Volume Adjustment 2. Pan-n-Tilt 3. Night Vision 4. Talk back 5. VOX Mode 6. Add Camera 7. Camera Night Light Adjustment 8. Lullabies 9. Alarm Clock 10. Temperature 11. Alarm Volume 12. System Version TROUBLESHOOTING WARRANTY & CUSTOMER SERVICE FCC COMPLIANCE WEEE COMPLIANCE 01 01 02 03 09 09 09 09 10 10 10 11 11 12 12 13 13 14 16 17 17 18 19 19 20 21 21 22 ENGLISH SAFETY INSTRUCTIONS · Keep cord out of the reach of children (more than 3ft (0.9m) away) in case of STRANGULATION. · NEVER place the camera or cord in or near the crib or playpen. · NEVER mount the camera directly above the crib or playpen to avoid the risk of injury. · Only use the AC adapters provided. · Never use the unit near water, including near a bathtub, sink, laundry machine tube, wet basement, etc. · Do not install near any heat sources such as radiators, heat registers, stoves, or other devices that produce heat. · Only use attachments and accessories specified by the manufacturer. · Unplug this device when unused for long periods of time. CAUTION · NOT toys. Do not allow children to play with them. · This product is NOT intended to replace the proper supervision of children. You MUST check your child’s activity regularly. · This product is not intended for use as a medical camera and its use should not replace adult supervision. · Unplug the product during lightning storms. 1m · Please check the operating range and condition of the camera carefully at the initial installation, and on a regular basis after that. · Check the reception regularly. Test the camera before use and after changing the camera’s location. · For indoor use only. · Clean the camera with a dry cloth only. · Do not block any ventilation openings. · Microphone feedback might occur when the monitor is too close to the camera. Please keep them at least 1.5m /4.9ft apart. PACKAGE CONTENTS Camera*1 Monitor*1 Power Cable*2Adapter*2(Optional) User Guide*1 0102 ENEN PRODUCT DIAGRAM 2.8 LCD Baby Monitor 1 3 4 6 7 9 10 5 8 2 11 12 13 15 14 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Charging indicator light: blue when charging, green when fully charged. Status/Low battery indicator light: When the monitor is turned on, it stays on in green; When the battery level is too low, green flashes. Sound Level LED: Low/high level shows low/high sound detected by the camera. Microphone Up Button: Press to increase the volume or to change your selection upward. Left Button: Press to dim the brightness or to change your selection leftward. Two Way talk: Press and hold to talk with your baby. Right Button: Press to increase the brightness or to change your selection rightward. Confirm Button: Press to Zoom in/out or to confirm your selection. Down Button: Press to decrease the volume or to change your selection downward. Menu/Back Button: Press to enter menu page or press as a back key. Monitor & Screen On/Off: Long press to turn on/off the monitor; short press to turn on/off the screen. Power Input Antenna Stand Speaker Reset 0304 ENEN 3.2 LCD Baby Monitor 1 2 3 4 6 8 10 12 11 13 15 5 7 9 14 16 19 18 17 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 VOX shortcut: Turn on or off the sound detection function. Monitor & Screen On/Off: Long press to turn on/off the monitor; short press to turn on/off the screen. Menu/Back Button: Press to enter menu page or press as a back key. Camera switching: switch or cycle multiple cameras. Charging indicator light: blue when charging, green when fully charged. Up Button: Press to tilt the camera upward or to change your selection upward. Left Button: Press to pan the camera leftward or to change your selection leftward. Right Button: Press to pan the camera rightward or to change your selection rightward. Confirm/Zoom Button: Press to Zoom in/out or to confirm your selection. Down Button: Press to tilt the camera downward or to change your selection downward. Monitoring Status Indicator: Green. When the camera is Status/Low battery indicator light: When the monitor is turned on, it stays on in green; When the battery level is too low, green flashes. Two way talk:Press and hold to talk with your baby. Volume/Brightness shortcut: Press to adjust the brightness and volume. Sound Level LED: Low/high level shows low/high sound detected. When there is alarm, 4 LEDs all blink together every four seconds. Microphone Antenna Stand Power Input Speaker Reset 0506 ENEN Camera 1 Camera Lens 2 Night Vision Sensor 3 Microphone 4 Power Input 5 Antenna/Temperature Sensor 6 Pair Button 1 Infrared LEDS 2 Microphone 3 Colorful Night Light 4 Night Vision Sensor 5 Camera Lens 6 Speaker 7 Temperature Sensor & Power Input 8 Pair Button 01 02 03 04 05 01 02 03 04 05 06 07 08 06 01 02 03 04 05 06 0708 ENEN GETTING STARTED 1. Charging & Powering Monitor 1) Connect the monitor to a power source via the type-C cable and power adapter. 2) Unplug the unit when its power indicator turns off, indicating a full charge. Of course, if it stays plugged in, it will not affect the use, but it may affect the battery life. 3) Press the power button on the monitor to turn on the device. See green power indicator lighting. 2. Powering Camera 1) Connect the camera to a power source via the type-C cable and power adapter. • Only use the power adapters included in the package. • Do not place the camera and power cord within the reach of your baby. For safety reasons and better vision in night vision mode, place the camera on a 0.75m table top and ensure the distance from the baby is at least 1.5m. 3. Placing the Camera 0.75m 1.5m °C / °F No Signal Connection Signal Strength Cycle Camera Enabled (Swi…
Text truncated - open the document above for the full version.
ShenzhenDayunLinksCo.,Ltd Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,NantongAvenue, BaolongStreet,Longgang,Shenzhen,Guangdong,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 Date:May19,2026 U.S.AgentDesignation {ShenzhenDayunLinksCo.,Ltd}acknowledgestheirconsentforthefollowingcontactlocatedintheUnited Statestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID: 2ANBK-BM301A): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Shenzhen DayunLinksCo.,Ltd}. {ShenzhenDayunLinksCo.,Ltd}withtheFRN[0026747659]acceptsitsobligationtomaintainanagentfor serviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature ChenDong Manager ShenzhenDayunLinksCo.,Ltd Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2ANBK-BM301A BM301, BM302, BM303, BM530, BM5G10L, BM5G09L, BM5G08L We, Applicant Company Name: Shenzhen Dayun Links Co., Ltd Address: Room 501, No.B Building 1, Bestda Medical DeviceBuilding, No.28, Nantong Avenue, Baolong Street, Longgang, Shenzhen, Guangdong, China Phone: +86-755-89357215 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-05-18 Signature Date Name / Title: Chen Dong / Manager Company: Shenzhen Dayun Links Co., Ltd Address: Room 501, No.B Building 1, Bestda Medical DeviceBuilding, No.28, Nantong Avenue, Baolong Street, Longgang, Shenzhen, Guangdong, China Phone: +86-755-89357215 Fax: N/A E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2ANBK-BM301A BM301, BM302, BM303, BM530, BM5G10L, BM5G09L, BM5G08L Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-05-15
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2ANBK-BM301A BM301, BM302, BM303, BM530, BM5G10L, BM5G09L, BM5G08L For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-05-18 Signature Date Name / Title: Chen Dong / Manager Company: Shenzhen Dayun Links Co., Ltd Address: Room 501, No.B Building 1, Bestda Medical DeviceBuilding, No.28, Nantong Avenue, Baolong Street, Longgang, Shenzhen, Guangdong, China Phone: +86-755-89357215 Fax: N/A E-Mail: [email protected]
Page 1 of 1 Rev.2.0 Shenzhen Dayun Links Co., Ltd WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: 2ANBK-BM301A Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo- location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Chen Dong / Manager Signature: Phone: +86-755-89357215 Email: [email protected] Date: 2026-05-18
Externalphotos FCC ID: 2ANBK-BM301A
Internalphotos FCC ID: 2ANBK-BM301A Antenna
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260400811E-02 Applicant:ShenzhenDayunLinksCo.,Ltd AddressofApplicant:Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,Nantong Avenue,BaolongStreet,Longgang,Shenzhen,Guangdong, EquipmentUnderTest(EUT): EUTName:VideoBabymonitor ModelNo.: BM301,BM302,BM303,BM530,BM5G10L,BM5G09L,BM5G08L TestModelNo.:BM301 BrandName:N/A FCCID:2ANBK-BM301A Standards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2026-04-21 DateofTest: 2026-04-21to2026-04-29 DateofIssue:2026-5-15 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD. ReportNo.:CQASZ20260400811E-02 Page:2of7 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260400811E-02Rev.01 Initialreport 2026-5-15 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD. ReportNo.:CQASZ20260400811E-02 Page:3of7 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOF2.4GWIFICLASSIC...........................................................................................................4 4RFEXPOSUREEVALUATION.......................................................................................................................................5 4.1SAREVALUATIONFORPORTABLECONDITION...........................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.1.3SARExclusionEvaluationResult...................................................................................................................7 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD. ReportNo.:CQASZ20260400811E-02 Page:4of7 3GeneralInformation 3.1ClientInformation Applicant:ShenzhenDayunLinksCo.,Ltd AddressofApplicant:Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,Nantong Avenue,BaolongStreet,Longgang,Shenzhen,Guangdong, Manufacturer:ShenzhenDayunLinksCo.,Ltd AddressofManufacturer:Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,Nantong Avenue,BaolongStreet,Longgang,Shenzhen,Guangdong, Factory:ShenzhenDayunLinksCo.,Ltd AddressofFactory:Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,Nantong Avenue,BaolongStreet,Longgang,Shenzhen,Guangdong, 3.2GeneralDescriptionofEUT ProductName: VideoBabymonitor ModelNo.: BM301,BM302,BM303,BM530,BM5G10L,BM5G09L,BM5G08L TestModelNo.: BM301 TradeMark: N/A SoftwareVersion: V1.0 HardwareVersion: V1.0 PowerSupply: Li-ionbattery:DC3.7V1500mAh5.55Wh,ChargebyDC5Vforadapter SimultaneousTransmissionSimultaneousTXissupportedandevaluatedinthisreport. SimultaneousTXisnotsupported. 3.3GeneralDescriptionof2.4GWIFIClassic OperationFrequency: 2412MHz~2462MHz TypeofModulation: IEEEfor802.11b:DSSS(CCK,DQPSK,DBPSK) IEEEfor802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEEfor802.11n(HT20):OFDM(64QAM,16QAM,QPSK,BPSK) NumberofChannel: IEEE802.11b/g,IEEE802.11nHT20:11Channels ChannelSeparation: 5MHz TransferRate: IEEEfor802.11b: 1Mbps/2Mbps/5.5Mbps/11Mbps IEEEfor802.11g: 6Mbps/9Mbps/12Mbps/18Mbps/24Mbps/36Mbps/48Mbps/54Mbps IEEEfor802.11n(HT20): 6.5Mbps/13Mbps/19.5Mbps/26Mbps/39Mbps/52Mbps/58.5Mbps/65Mbps SampleType: MobilePortable AntennaType:FPCantenna AntennaGain:3dBi SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD. ReportNo.:CQASZ20260400811E-02 Page:5of7 4RFExposureEvaluation 4.1 SAREvaluationforPortablecondition 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataasrepresentative ofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttestpositions(e.g.body, head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.Thistestreductionprocess providesfortheuseoftestdataforonespecificchannel,whilereferencingtothosedatafordemonstrating complianceinotherrequiredchannelsforeachtestpositionofanexposurecondition,withintheoperating modeofafrequencyband.Thisislimitedspecificallytowhenthereported1-gor10-gSARforthemid- bandorhighestoutputpowerchannelmeetsanyofthefollowingconditions. 4.1.2Limits SAR-basedthresholdsarederivedbased…
Text truncated - open the document above for the full version.
地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 1 页共 9 页 承认书 SPECIFICATIONFORAPPROVAL 客户名称 CUSTOMERNAME: 客户料号 CUSTOMERP/N: 产品料号 PRODUCTP/N:Z1C75F3D60A 产品名称 PRODUCTNAME:2.4GHz 天线 规格描述: Description: Z1C75F3D60A/2.4GHz内置FPC天线/1.13灰色线 L=75mm+出线端剥线:1、1.5、1.8 版本 REV:A版 出厂签章 S I G N 核准 APPROVEDBY 审核 CHECKEDBY 制作 DRAMN 客户签章 S I G N 品质 QE 开发 R&D 工程 PE Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 2 页共 9 页 Contents ltemDescription 一、------------------------------------------------------------变更履历 二、-----------------------------------------------------------规格表 三、----------------------------------------------------------成品图 四、---------------------------------------------------------测试报告 五、-------------------------------------------------------产品实物图 Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 3 页共 9 页 一、版本履历表(RevisionHistory): 说明: 本规格书原则上有效期为1年; 若任一方需要修改时,需经双方协商一致,修改后方可执行; 在本规格书有效期满后,双方均未提出修改要求时,则本规格书有效期顺延1 年。 Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 4 页共 9 页 二、规格表(SpecificationTable): 产品主要技术参数 主要技术指标Maintechnicalspecifications 频率范围 (MHZ) 2400-2500 FrequencyRange (MHZ) 2400-2500 特性阻抗(Ω) 50Impedance(Ω)50 增益(dBi) 300 Gain(dBi) 3.00 输出电压 驻波比 ≤2.0VSWR≤2.0 极化方式 线极化PolarizationLinear 方向性 全向性 RadiationOmni-directional 物理性能PhysicalProperties 天线材料 FPCAntennacoverFPC 连接方式 IPEXConnectorTypeIPEX 线材总长 75mmTotallength75mm 外露线长 75mmExposedlength75mm 工作温度 -20 °C ~+70 °C OperatingTemp-20 °C ~+70 °C 保存温度 -20°C~+60°CStorageTemp-20°C~+60°C Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 5 页共 9 页 三、成品图(Productdrawing): Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 6 页共 9 页 四、测试报告(Testreport): 5.1:网络分析仪测试报告 Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 7 页共 9 页 5.2:暗室2D、3DRaditationPattern 2400MHz 2450MHz 2500MHz Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 8 页共 9 页 2400-2500MHZ-Phi0 2400-2500MHz-Phi90 2400-2500MHz-Theta90 Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China 地址:东莞市塘厦镇清湖头建隆科创园4栋6楼第 9 页共 9 页 5.3:天线增益与效率 五、产品实物图(Productdrawing) ANT 频率(MHZ)增益(dBi)效率(%) 24001.7861.06 24502.7262.72 25002.5260.08 Address: Building 4, 6th Floor, Jianlong Science and Technology Park, Qinghutou, Tangxia Town, Dongguan, China
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260400811E-01 Applicant:ShenzhenDayunLinksCo.,Ltd AddressofApplicant:Room501,No.BBuilding1,BestdaMedicalDeviceBuilding,No.28,Nantong Avenue,BaolongStreet,Longgang,Shenzhen,Guangdong, EquipmentUnderTest(EUT): Product:VideoBabymonitor ModelNo.: BM301,BM302,BM303,BM530,BM5G10L,BM5G09L,BM5G08L TestModelNo.:BM301 BrandName:N/A FCCID:2ANBK-BM301A Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-04-21 DateofTest: 2026-04-21to2026-04-29 DateofIssue:2026-5-15 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove . TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260400811E-01 Page:2of88 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260400811E-01Rev.01 Initialreport 2026-5-15 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260400811E-01 Page:3of88 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement47CFRPart15.203N/APASS ACPowerLine Conducted Emission 47CFRPart15.207 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS ConductedPeak& AverageOutputPower 47CFRPart15.247 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS 6dBOccupied Bandwidth 47CFRPart15.247 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS PowerSpectralDensity47CFRPart15.247 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15.247 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS RFConductedSpurious Emissions 47CFRPart15.247 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS RadiatedSpurious Emissions 47CFRPart15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a- 2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260400811E-01 Page:4of88 Remark: Thetestedsample(s)andthesampleinformationareprovidedbytheclient. Tx:InthiswholereportTx(ortx)meansTransmitter. Rx:InthiswholereportRx(orrx)meansReceiver. RF:InthiswholereportRFmeansRadiatedFrequency. CH:InthiswholereportCHmeanschannel. Volt:InthiswholereportVoltmeansVoltage. Temp:InthiswholereportTempmeansTemperature. Humid:InthiswholereportHumidmeanshumidity. Press:InthiswholereportPressmeansPressure. N/A:Inthiswholereportnotapplication SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260400811E-01 Page:5of88 3Contents Page 1VERSION......................................................................................................................................................................2 2TESTSUMMARY........................................................................................................................................................3 3CONTENTS..................................................................................................................................................................5 4GENERALINFORMATION.......................................................................................................................................6 4.1CLIENTINFORMATION.............................................................................................................................................6 4.2GENERALDESCRIPTIONOFEUT..........................................................................................................................6 4.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD................................................................................6 4.4TESTENVIRONMENTANDMODE...........................................................................................................................9 4.5DESCRIPTIONOFSUPPORTUNITS......................................................................................................................13 4.6TESTLOCATION....................................................................................................................................................13 4.7TESTFACILITY......................................................................................................................................................13 4.8TESTCONFIGURATION..........................................................................................................................................13 4.9STATEMENTOFTHEMEASUREMENTUNCERTAINTY...........................................................................................14 4.10DEVIATIONFROMSTANDARDS..........................................................................................................................14 4.11ABNORMALITIESFROMSTANDARDCONDITIONS..............................................................................................14 4.12OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..................................................................................14 4.13EQUIPMENTLIST................................................................................................................................................15 5TESTRESULTSANDMEASUREMENTDATA..................................................................................................16 5.1ANTENNAREQUIREMENT.............................................…
Text truncated - open the document above for the full version.
Setupphotos 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2ANBK-BM301A Above1GHz: 1.2ConductedEmission 1.3RFConductedmeasurement
3330 W 38TH PL, CHICAGO, · Illinois, 60632 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 2.20 mW |

WiFi Baby monitor
Equipment Class
DTS - Digital Transmission System
WiFi Baby monitor
Equipment Class
DTS - Digital Transmission System
Video baby monitor
Equipment Class
DTS - Digital Transmission System
Video baby monitor
Equipment Class
DTS - Digital Transmission System
Video baby monitor
Equipment Class
DTS - Digital Transmission System