Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 21, 2021
Application Purpose
Original Equipment
Date of Application
Jun 21, 2021
Equipment Note
Camera Flash
Frequency Range
2412.76000000 - 2464.12000000
Company
Shenzhen Neewer Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Shenzhen Neewer Technology Co., Ltd Add: ROOM 1901-1903, Block A, LU SHAN BUILDING NO.3023 CHUNFENG RD LUO HU DISTRICT SHENZHEN China Date: 2021-6-22 FCC ID: 2ANIV-NW420 Dear Sir/Madam, We, Shenzhen Neewer Technology Co., Ltd Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Camera Flash Model no.: NW420-N, NW410, NW420-C, NW420-S, NW430-N, NW430-C, NW430-S, NW450-N, NW450-C, NW450-S, NW420 II-C, NW420 II-N, NW420 II-S Sincerely, Name/Title: Ting Peng/Director Company: Shenzhen Neewer Technology Co., Ltd Address: ROOM 1901-1903, Block A, LU SHAN BUILDING NO.3023 CHUNFENG RD LUO HU DISTRICT SHENZHEN China Phone: +8675525984843 Fax: +8675525984843 E-Mail: [email protected]

Cover Letter(s)

Shenzhen Neewer Technology Co., Ltd ROOM 1901-1903, Block A, LU SHAN BUILDING NO.3023 CHUNFENG RD LUO HU DISTRICT SHENZHEN China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-6-22 To whom it may concern: We, Shenzhen Neewer Technology Co., Ltd the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2ANIV-NW420 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Ting Peng/Director Company: Shenzhen Neewer Technology Co., Ltd Address: ROOM 1901-1903, Block A, LU SHAN BUILDING NO.3023 CHUNFENG RD LUO HU DISTRICT SHENZHEN China Phone: +8675525984843 Fax: +8675525984843 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 9 Fig. 10

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size: L3.15cm*W1.95cm Label Location Camera Flash Model No.: NW420-N FCC ID: 2ANIV-NW420

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 1. INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Fig. 9 2.4G Antenna

RF Exposure Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 s FCC RF Exposure Evaluation 1. Product Information FCC ID: 2ANIV-NW420 Product name Camera Flash Model number NW420-N Additional Model NW410, NW420-C, NW420-S, NW430-N, NW430-C, NW430-S, NW450-N, NW450-C, NW450-S, NW420 II-C, NW420 II-N, NW420 II-S Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power supply DC 3V by 2*AA batteries Modulation Type MSK Channel Number 32 channels Antenna Type Spring Antenna Antenna Gain 3.0 dBi (maximum) Hardware version / Software version / Operation frequency 2412.76MHz-2464.12MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable 2. Evaluation Method According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b) The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results 2.4GHz Transmit Mode Channel Frequency(MHz) Peak Conducted Output Power (dBm) MSK 0 2412.76 -4.034 16 2439.32 -4.116 31 2464.12 -4.315 5. Manufacturing Tolerance 2.4GHz Transmit MSK (Peak) Channel Channel 0 Channel 16 Channel 31 Target (dBm) -4.0 -4.0 -4.0 Tolerance ±(dB) 1.0 1.0 1.0 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclusion Threshold SAR Test Exclusion dBm mW MSK 2.41276 5 -3.0 0.5012 0.16 < 3.0 Yes Remark: (1). RF output power including tune up tolerance; (2). When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 1 of 14 Appendix A RF Test Data for 2.4G (Conducted Measurement) Product Name: Camera Flash Trade Mark: NEEWER Test Model: NW420-N Environmental Conditions Temperature: 24.6  C Relative Humidity: 54.1% ATM Pressure: 100.0 kPa Test Engineer: Kay Hu Supervised by: Li Huan A.1 Duty Cycle Test Mode Test Channel Ant Duty Cycle[%] Verdict MSK 2439.32 Ant1 100 PASS # SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 2 of 14 A.2 Maximum Conducted Peak Output Power Mode Channel Conduct Peak Power[dBm] Limit [dBm] Verdict MSK LCH -4.034 30 PASS MSK MCH -4.116 30 PASS MSK HCH -4.315 30 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 3 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 4 of 14 A.3 Maximum Power Spectral Density Mode Channel PSD [dBm/3KHz] Limit [dBm/3KHz] Verdict MSK LCH -13.021 8 PASS MSK MCH -12.929 8 PASS MSK HCH -12.873 8 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 5 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 6 of 14 A.4 6dB Bandwidth Mode Channel 6dB Bandwidth [MHz] Limit [MHz] Verdict MSK LCH 501.2 ≥0.5 PASS MSK MCH 504.4 ≥0.5 PASS MSK HCH 500.8 ≥0.5 PASS Test Graphs LCH MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 7 of 14 HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 8 of 14 A.5 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdict MSK LCH -4.516 -36.943 -24.516 PASS MSK MCH -4.473 -30.183 -24.473 PASS MSK HCH -4.746 -35.893 -24.746 PASS MSK_LCH_Graphs Pref/MSK/LCH Puw/MSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 9 of 14 MSK_MCH_Graphs Pref/MSK/MCH Puw/MSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 10 of 14 MSK_HCH_Graphs Pref/MSK/HCH Puw/MSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 11 of 14 A.6 Band-edge for RF Conducted Emissions Mode Channel Carrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm] Verdict MSK LCH -4.684 -49.514 -24.68 PASS MSK HCH -4.617 -49.206 -24.62 PASS Test Graphs LCH HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 12 of 14 A.7 Restrict-band band-edge measurements Test Mode Test Chann el Ant Freq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBuV/ m] Verdi ct MSK 2412.7 5 Ant1 2310.0 -42.80 3.0 0 55.46 PEAK 74 PASS Ant1 2310.0 -53.31 3.0 0 44.95 AV 54 PASS Ant1 2390.0 -41.78 3.0 0 56.48 PEAK 74 PASS Ant1 2390.0 -52.99 3.0 0 45.27 AV 54 PASS 2464.2 5 Ant1 2483.5 -43.03 3.0 0 55.23 PEAK 74 PASS Ant1 2483.5 -52.58 3.0 0 45.68 AV 54 PASS Ant1 2500.0 -42.77 3.0 0 55.49 PEAK 74 PASS Ant1 2500.0 -52.36 3.0 0 45.90 AV 54 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 13 of 14 Restrict-band band-edge measurements_MSK_2412.75_Ant1_PEAK Restrict-band band-edge measurements_MSK_2412.75_Ant1_AV SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 Report No.: LCS210426122AEA Page 14 of 14 Restrict-band band-edge measurements_MSK_2464.25_Ant1_PEAK Restrict-band band-edge measurements_MSK_2464.25_Ant1_AV

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ANIV-NW420 _______________________________________________________________________________________________ 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

Ting Peng(Director)
[email protected]+8675525984843Fax: +8675525984843

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Shenzhen Neewer Technology Co., Ltd

SELFIE MONITOR SCREEN - FCC ID 2ANIV-F4 - Shenzhen Neewer Technology Co., Ltd
2ANIV-F4

SELFIE MONITOR SCREEN

May 21, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
TTL Li-ion Camera Flash - FCC ID 2ANIV-Z880 - Shenzhen Neewer Technology Co., Ltd
2ANIV-Z880

TTL Li-ion Camera Flash

Jul 17, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Side Handle With Wireless Control - FCC ID 2ANIV-RT005E - Shenzhen Neewer Technology Co., Ltd
2ANIV-RT005E

Side Handle With Wireless Control

Jul 09, 2024

Equipment Class

DTS - Digital Transmission System
2ANIV-PA060

NEEWER Cell Phone Cooler

Apr 14, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
GAME PANEL LIGHT - FCC ID 2ANIV-GL1 - Shenzhen Neewer Technology Co., Ltd
2ANIV-GL1

GAME PANEL LIGHT

Aug 30, 2023

Equipment Class

DTS - Digital Transmission System