FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Neewer Technology Co., Ltd/
  3. 2ANIV-WRP18

2ANIV-WRP18WIFI RING LIGHT

Shenzhen Neewer Technology Co., Ltd
WIFI RING  LIGHT - FCC ID 2ANIV-WRP18 - Shenzhen Neewer Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 18, 2021
Application Purpose
Original Equipment
Date of Application
Apr 16, 2021
Equipment Note
WIFI RING LIGHT
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Neewer Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Neewer Technology Co., Ltd Statement We Shenzhen Neewer Technology Co., Ltd Hereby Declare that The product WIFI RING LIGHT, models no. WRP18, WRP14, WRP16, WRP20 are all identical in the Power Board, WIFI Board and Control Board, Only the LED Board is different for different ring size. Your assistance on this matter is highly appreciated. Dated this: April 19, 2021 Agency agreement expiration date: 12 Months By: Ting Peng Signature Printed Title: Direct On behalf of: Shenzhen Neewer Technology Co., Ltd Tel No: +8675525984843

Cover Letter(s)

April 19, 2021 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ANIV- WRP18 Product Name: WIFI RING LIGHT Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this: April 19, 2021 Agency agreement expiration date: 12 Months By: Ting Peng Signature Printed Title: Direct On behalf of: Shenzhen Neewer Technology Co., Ltd Tel No: +8675525984843

Cover Letter(s)

April 19, 2021 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Shenzhen Neewer Technology Co., Ltd / ROOM 1901-1903, Block A, LU SHAN BUILDING NO.3023, CHUNFENG RD LUO HU DISTRICT,SHENZEN, China Dated this: April 19, 2021 Agency agreement expiration date: 12 Months By: Ting Peng Signature Printed Title: Direct On behalf of: Shenzhen Neewer Technology Co., Ltd Tel No: +8675525984843

External Photos

Photographs – EUT Outside View Outside View Outside View

ID Label/Location Info

Mark Location: FCC ID: 2ANIV-WRP18 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must a ccept any interference received, including interference that may cause undesired operation.

Internal Photos

Inside view Inside view

Internal Photos

Inside view Inside view Inside view

RF Exposure Info

Maximum Permissible Exposure FCC ID: 2ANIV-WRP18 Applicable Standard Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2m normally can be maintained between the user and the device. (a) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times ︱E︱ 2 , ︱H︱ 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100000 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times ︱E︱ 2 , ︱H︱ 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100000 1.0 30 Note: f=frequency in MHz; *Plane-wave equivalent power density MPE Calculation Method E (V/m) = (30*P*G) 0.5 /d Power Density: Pd (W/m 2 ) = E 2 /377 E = Electric Field (V/m) P = Peak RF output Power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = (30*P*G) / (377*d 2 ) From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. Calculated Result and Limit Antenna Gain:2.5dBi (2.4G Band) Antenna Gain (Numeric) Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 1.778 17.72 59.16 0.02 1 Compiles Note: the worse case was recorded.

Test Report

Report No.: TW2103123E File Reference No.: 2021-04-02 Applicant: Shenzhen Neewer Technology Co., Ltd Product: WIFI RING LIGHT Model No.: WRP18, WRP14, WRP16, WRP20 Trademark: NEEWER Test Standards: FCC Part 15.247 Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10, FCC Part 15.247 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: April 02, 2021 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2103123E Page 2 of 80 Date: 2021-04-02 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with “Quality Law of People’s Republic of China” Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2103123E Page 3 of 80 Date: 2021-04-02 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details............................................................................................... 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 5 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty............................................................................................... 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 8 3.1 Summary of Test Results..................................................................................... 8 3.2 Test Standards.................................................................................................. 8 4.0 EUT Modification............................................................................................. 8 5.0 Power Line Conducted Emission Test...................................................................... 9 5.1 Schematics of the Test........................................................................................ 9 5.2 Test Method and Test Procedure............................................................................ 9 5.3 Configuration of the EUT.................................................................................... 9 5.4 EUT Operating Condition.…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Ting Peng(Director)
[email protected]+8675525984843Fax: +8675525984843

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz59.16 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Neewer Technology Co., Ltd

SELFIE MONITOR SCREEN - FCC ID 2ANIV-F4 - Shenzhen Neewer Technology Co., Ltd
2ANIV-F4

SELFIE MONITOR SCREEN

May 21, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
TTL Li-ion Camera Flash - FCC ID 2ANIV-Z880 - Shenzhen Neewer Technology Co., Ltd
2ANIV-Z880

TTL Li-ion Camera Flash

Jul 17, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Side Handle With Wireless Control - FCC ID 2ANIV-RT005E - Shenzhen Neewer Technology Co., Ltd
2ANIV-RT005E

Side Handle With Wireless Control

Jul 09, 2024

Equipment Class

DTS - Digital Transmission System
2ANIV-PA060

NEEWER Cell Phone Cooler

Apr 14, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
GAME PANEL LIGHT - FCC ID 2ANIV-GL1 - Shenzhen Neewer Technology Co., Ltd
2ANIV-GL1

GAME PANEL LIGHT

Aug 30, 2023

Equipment Class

DTS - Digital Transmission System