Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1. To access the battery compartment, twist open the back half of the light counterclockwise. 2. Remove the battery compartment cover by squeezing the two tabs on the cover inward. 5. Reassemble the Motion-Activated Anywhere Light by twisting the back half of the light clockwise tightly to ensure a weather proof seal. 4. 3. Totally portable and weatherproof. Perfect outdoors for doors, steps, decks, sheds, garages, pathways, porches, and anywhere additional light is needed. Also perfect indoors for hallways, stairways,closets, and bathrooms. Built-in motion sensor automatically turns on the light when movement is detected in the area. The light remains on while motion continues to be detected in the area. Built-in photosensor enables the light to only turn on at night. The 4 super bright LEDs have an estimated life of 30,000 hours, so they never need changing. D 40251,40252 ANYWHERE LIGHT motion-activated ABOUT YOUR MOTION-ACTIVATED ANYWHERE LIGHT Anywhere Requires 4 D cell batteries (not included). The batteries typically last up to 1 year under normal use. TM TM TM TM Press Tabs 1. In order to mount the light securely to a wall or other stable surfaces, the mounting base needs to be installed. Slide the the mounting place to separate it from the main body. 2. If you are installing the mounting place on a very hard surface, you may need to drill holes for the screws first. The included screw anchors can be used for drywall, cement, brick, or similar surfaces. 3. Use the two screws supplied to install the mounting plate. 1. Align the base to the mounting plate. Slide the main body onto the mounting plate until it snaps into place. At night, the LED lights will remain on for approximately 30 seconds after the last detected movement. If a movement is detected while the lights are on, the light duration will be reset and remain on for another 30 seconds. Depending on your preferences, you can rotate the base on the mounting plate or make the motion sensor and the light swivel to aim at different directions. because 25 feet fresh Anywhere Anywhere Anywhere Anywhere Anywhere Anywhere TM TM TM TM TM TM Page 2 0.33 approx. 30 seconds [email protected] Page 3 Lumens00 FCC Warning and Notes Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Aurolite Electrical Panyu Guangzhou Limited [2020-07-08] Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement Aurolite Electrical Panyu Guangzhou Limited FCC ID: 2ANJCALRB058B To Whom It May Concern: We, Aurolite Electrical Panyu Guangzhou Limited, hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number (2ANJCALRB058B) under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is (2020-07-08). The Limited Agency Agreement expires on (2020-12-08), unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Luo Wangxian Manager
30mm 40mm This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Job No.: 191231035GZU Page: 1 of 1 FCC ID: 2ANJCALRB058B RF Exposure Compliance Requirement Calculation formula: E (V/m) = (30*P*G) 0.5 /d E = Electric Field (V/m) P = Peak RF output Power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between EUT and antenna (m) P=(E*d) 2 /30G In the formula above, d=3m, field strength= 65.3dBuV/m(max.provided by client), antenna gain= 0.8dBi so P=0.00085mW In KDB 447498 D01 v06: 4.3.1 Standalone SAR test exclusion considerations: The SAR Test Exclusion Threshold is calculated from: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR. The worst case test separation distance is 5mm. The product belongs to standalone portable device base the FCC rule part 2.1091&2.1093. The transmission frequencies of the device are between 100 MHz and 6 GHz. The SAR Test Exclusion Threshold (mW) is listed below: Transmit frequency (MHz) Output power (mW) SAR Test Exclusion Threshold (mW) 433.88 0.00085 22.77 According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure Guidance v06, the SAR report is not required.
1. Radiated Emissions in Restricted Bands: Below 1GHz: Above 1GHz:
Room102/104 · Guangzhou · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.88 MHz - 433.88 MHz | - |